RequiredExperience with Government
RequiredAnnual Turnover Bid to RA enabled No Spectrum Analyzers Vector Network Analyzers ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) FEATURES Description of the itemuu Two port vector network analyzers (without spectrum analyser) Spectrum analyzers
RequiredTwo port vector network analyzers(with spectrum analyser)
RequiredTwo port vector network analyzers (without spectrum analyser) GENERAL FEATURES COMMON TO SPECTRUM AND Markers Normal
Requireddelta * 1/5 VECTOR ANALYSER Trigger Free run
Requiredvideo
RequiredExternal * Display TFT Colour display with provision for three traces * Interface USB
RequiredLAN * Software for transfer of screen shot/measurement data to PC Yes * SPECTRUM ANALYZER FEATURES Frequency Range NA 9 kHz to 3 GHz
Required9 kHz to 7 GHz
Required9 kHz to 13 GHz
Required100 kHz to 18 GHz
Required9 kHz to 26.5 GHz
Required9 kHz to 40 GHz
Required9 kHz to 6 GHz
RequiredNA Aging rate of spectrum analyzer frequency: Better than 1x10-6 Year NA * Frequency counter Resolution(minimum) (Hz) NA * Frequency Span NA * Spectral purity:SSB Phase Noise @10KHz offset shall be less than -90dBc/Hz at 1GHz NA * Spectral purity:Harmonics @ -40dBm level <=60 dBc NA * Sweep time @span >or= 1 KHz NA * Sweep time @span = 0 Hz NA * Resolution Bandwidth (-3dB) NA * Video Bandwidth NA * Amplitude : Max input level for protection (dBm) NA * Amplitude : Max input level for measurement (dBm) NA * Amplitude :level measurement uncertainity (dB) NA * Average noise level dis NA * 2/5 played(@300HzRBW
Required10 Hz VBW) Average noise level dis played(@100HzRBW
Required1 Hz VBW) NA * Average noise level dis played(@300HzRBW
Required1 Hz VBW) NA * Measurement features NA * VECTOR NETWORK ANALYZER FEATURES Frequency Range for 2port vector network analyzer 2 MHz to 6 GHz * Frequency Resolution (CW ON) (Hz) 10 * Return Loss (dB) 0.00 to 60 * VSWR (dB) 1.01 to 10.00 * Cable Loss (dB) 0.00 to 30.00 * Calibration with Precision calibration components-open
Requiredshort
Requiredload should be included to achieve directivity >35 dB Yes * Abilty to locate Distance-to-fault in Co- axial cables yes * Phase Range (degree) -180 to +180 * Phase Resolution (deg) 0.01 * RF output port Type N
Requiredfemale
Required50Ohm * Dynamic Range 60 * Nominal port power output: Hi Power/Lo- Power selectable yes * Power levels corresponding to Hi and Lo levels - * Measurement of S11 and S21 and Smith Chart Yes * Vector Voltmeter for comparision and verification of the phase of the phase- matched cables Yes * Group Delay measurement - * 3/5 OPERATING CONDITIONS Operating Temperature '5 to 40 degree C & 80% RH @ 40 degree C '5 to 40 degree C & 80% RH @ 40 degree C Operating Humidity 80% RH @ 40 degree C 80% RH @ 40 degree C POWER REQUIREMENT Power requirement 230 +- 10 VAC
Required50Hz 230 +- 10 VAC
Required50Hz
RequiredRechargeable battery chemistry of the battery NA * Voltage of rechargeable Battery 0 * capacity of rechargeable battery (millAh) 0 * Suitable charger adaptor provided NA * WARRANTY Warranty 3 1
Required2
Required3
Required4
Required5 Or higher ACCESSORIES Details of Standard accessories covered in the scope of supply - * GENERIC Other features - * CERTIFICATION/TEST REPORT DETAILS The equipment supplied with calibration certificate yes * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest yes * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest yes * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH yes * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification No * Test Report Number and date for the specification test - * 4/5 Name and address of the Lab for the specification test - * * Bold specifications are the golden parameters.