Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹34.7 L
EMD Value
₹69,438
Closing Date
30 Jan 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Maintenance of Electrical works in DMFT Office Administrative Complex Pulwama Ground floor Phase I
2026_PWDJK_300038_1
NIT No.254/2025-26 Dt/07/01/2026
Open Tender
Electrical Works
Percentage
15 days
DMFT office Pulwama
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,100
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹69,438
7 Jan 2026
7 Jan 2026
31 Jan 2026
7 Jan 2026
30 Jan 2026
7 Jan 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS PVC insulated copper conductor ( Havell/Polycab/ paraflex/ Anchor/equivalent as directed by engineer incharge.) single core cable in surface / recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit/ duct( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.), with modular switch ( Legrand Mylinc/Legrand Alzy /ABB Tivishi/schneider Zencelo /Crabtree athena/ Eq. make.), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/ paraflex/ Anchor/equivalent as directed by engineer incharge.) single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor ( Havell/Polycab/ paraflex/ Anchor/equivalent as directed by engineer incharge.)single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required.
Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havell/Polycab/ paraflex/Anchor/ eq. make to be approved by EIC ) single core cable in surface/recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit ( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Modular Switch & Socket:- ( Legrand Mylinc/Allzy /ABB Tivisha/schneider Zencelo /Crabtree athena / eq. make to be approved by EIC.)
Wiring for 6- 10 amp power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/ paraflex/Anchor / eq. make to be approved by EIC) single core cable in surface/recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit ( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Legrand Mylinc/Legrand allzy /ABB Tivisha/schneider Zencelo /Crabtree athena / eq. make to be approved by EIC.)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. For AC's
Supplying and fixing following modular switch/ socket ( Legrand Mylinc /ABB Tivisha/schneider Zencelo /Crabtree athena / eq. make to be approved by EIC.) with modular plate and cover including switch box and connections etc. as required.
5/10 amps switch
15/16 amp switch
3 pin 5/10 amp socket outlet
6 pin 15/20 amp socket outlet
Telephone socket outlet
Bell push/ indicator
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell/Polycab/ paraflex/Anchor make/ equivalent as directed by engineer incharge.), single core cable in surface/ recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit as required.
(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
(d)2 X 6 sq. mm + 1 X 6 sq. mm earth wire
( e ) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
(f) 2 X 16 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, complete
Providing and fixing of 6-16mm Cu thimbles duly cramped at cable ends.
Supply installation testing and commissioning of 18 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium body and Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Havell/ Helonix /Wipro/ eq. make / sample to be approved before installation..
S/F testing and comm. Of 20 W + 4 ft. wall mounted LED batten with powdered coated aluminum housing & integrated electronic driver with minimum system lumen efficacy of 100 lm/W with THD<10%.( commercial series) CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Havell/Helonix /Wipro/ eq. make / sample to be approved before installation..
S/F testing and comm. Of 36 W + 4 ft. wall mounted LED batten with powdered coated aluminum housing & integrated electronic driver with minimum system lumen efficacy of 100 lm/W with THD<10%.( commercial series) CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Trulux /Wipro/ eq. make / sample to be approved before installation..
Supply installation testing and commissioning of 36 W + ( 2 ftx2 ft) LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/Havell/Helonix /Wipro/ eq. make / sample to be approved before installation..
Supply installation testing and comm. of flood light 100 W ( warm, white ), Epoxy powder coated die-cast aluminium housing (LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin-loopout class 1, IP66, IK 07, , with high power LED's as light source with Built-In Potted IP67 electronic LED driver with APFC,lower THD, toughned glass and secondary lens,Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1. Preferred make: Philips/ Havell /Wipro/Crompton / eq. make to be approved by EIC. the job also includes the angle iron stand of suitable size to be grouted in cement concrete with hold fasteners complete job.
Supply installation testing and comm. Of 200mm - 250mm sweep exhaust fan Shutter type of havell /USHA/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete . USHA /Havells /Crompton /orient/equivalent make as directed by engineer incharge.
Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor roma plus/Legrand Mylinc /ABB Tivisha/schneider Zencelo /Havell Coral / eq. make to be approved by EIC.
SITC of wall fan 400 mm sweep as approved by EIC ,240v,50 Hz complete , etc. as required. Make(Usha /Orient/Crompton/ Havells/ eq. make to be approved by EIC
Supply fixing testing and comm. Of backlite holder /batten holder/angle holder/ceiling rose SSK/Anchor / eq. make to be approved by EIC incl. PVC Block.
Supply, Installation, Testing & Commissioning of 6 KVA single-Phase IN single-Phase out ON Line UPS System to provide backup time of 60 minutes at full load, With In-Built Isolation Transformer of reputed make dully ISI Marked (APC Schineider/ETON/VERTIV/ equivalent standard make ) (Compitable to Genrator Supply having varing frequency) With on line double conversion topology, high frequency techonology, with front LCD,automatic bypass for fault tolerance & complete with required Number, 12 Volts 65 AH SMF VRLA Batteries ( Exide/ Amaron/Quanta / eq. make to be approved by EIC) with connecting links with angle iron battery stand complete job, complete with battery rack with two year warranty against any manufacturing defect. The job further includes AMC for UPS and batteries for a period of three years with replacement warrenty reckoned from date of sucessfull commissioning.
Sub Head-3 - Distribution system
Supplying and fixing following way, triple pole and neutral, sheet steel, MCB distribution board,( legrand/ Scheinider/ABB/Hager / eq. make to be approved by EIC) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
4 way, Double door ( 12+4)
8 way, Double door ( 24+4)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board,( legrand/ Scheinider/Hager make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
16 way, Double door
Supplying and fixing of following rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. legrand / Schinider/ABB ./equivalent make as directed by engineer incharge.
a) 6-32 Amp SP MCB
b) 40-63amp DP MCB
c) 40-63amp TPN MCB
Engaging of skilled labour for Dismentling of old damaged materials like wires in scraps, fixtures switches-sockets complete as directed by the engineer at site and stacking and handing over to concerned department including carrying out some repairing works etc.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
GF LT PANEL-1 .Supplying,Installation,Testing and Commissioning of Cubical Type Indoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42) General Floor Distribution Panel.The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.(Wall Mounted) Size of wiring for CTS:- 2.5 sqmm, Size of wiring for voltage sensing Metering :-4.0 Sq.mm, Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm,Types of wires:-PVC insulated 1100V grade ,Multistrand copper conductor Flexible FR-LSH, Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire, The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc, Gland Plates to be 3.0 mm Thick. ( As per approved design,size may vary as per site requirement)
Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.
Normal INCOMING:
a)630 Amp TPN MCCB 50 K including spreader links , icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/ABB/Semiens / eq. make to be approved by EIC.
b) 1000 amp 4 strip bus 1 No.
D) 315 amp onload changeover switch ABB/ Havell/ Socomac make
b) 600 amp 4 strip bus 1 No.
OUTGOING:
a)250 Amp TPN MCCB 50 K including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/ABB/Semiens / eq. make to be approved by EIC..
a)200 Amp TPN MCCB 50 K including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB / eq. make to be approved by EIC..
a)160 Amp TPN MCCB 36 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB / eq. make to be approved by EIC..
a)100 Amp TPN MCCB 36 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens / eq. make to be approved by EIC..
c) space for 18 way MCB's
Supplying,Installation,Testing and Commissioning of Cubical Type Indoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42) General Floor Distribution Panel.The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.(Wall Mounted) Size of wiring for CTS:- 2.5 sqmm, Size of wiring for voltage sensing Metering :-4.0 Sq.mm, Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm,Types of wires:-PVC insulated 1100V grade ,Multistrand copper conductor Flexible FR-LSH, Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire, The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc, Gland Plates to be 3.0 mm Thick.
a)160 Amp TPN MCCB 36 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens / eq. make to be approved by EIC...
a)100 Amp TPN MCCB 36 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens / eq. make to be approved by EIC...
OUTGOING:
M.C.B 63 A F.P 10 Ka"C Curve
M.C.B D.P 16-32 A 10 Ka"C Curve
M.C.B D.P 40-63 A 10 Ka"C Curve
Supplying,Installation,Testing and Commissioning of Cubical Type Indoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42) General Floor Distribution Panel.The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.(Wall Mounted) Size of wiring for CTS:- 2.5 sqmm, Size of wiring for voltage sensing Metering :-4.0 Sq.mm, Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm,Types of wires:-PVC insulated 1100V grade ,Multistrand copper conductor Flexible FR-LSH, Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire, The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc, Gland Plates to be 3.0 mm Thick.
a)160 Amp TPN MCCB 36 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens / eq. make to be approved by EIC.
a)100 Amp TPN MCCB 36 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens / eq. make to be approved by EIC.
OUTGOING:
M.C.B 63 A F.P 10 Ka"C Curve
M.C.B D.P 16-32 A 10 Ka"C Curve
M.C.B D.P 40-63 A 10 Ka"C Curve
Providing of Chemical earthing as per IS standards by way of digging 10' deep pit then embedding 3 meter G.I Earthing electrode , 80mm dia. connecting the plate with main control board by G.I Strip. Full thread brass nut and bolt and washers. Refilling of pit with chemical compound.
Supply, laying , testing and commissioning of PVC alluminium un-armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size.
a) 25 sq.mm 3.5 core
b) 35 sq.mm 3.5 core
c) 120 sq.mm 3.5 core
d) 70 sq.mm 3.5 core
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) including bends, Tees, cross members and allied accessories with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
200 mm width X 50 mm depth X 1.6 mm thickness
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.05 MB
BOQ_973472.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .