Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹18.0 L+₹62,848 (3.63%)Rejected-AOC 264 2 GALI NO 7 RAM NAGAR ROORKEE DIST HARIDWAR UK | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹18.2 L+₹84,162 (4.85%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹20.3 L+₹3.0 L (17.2%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹23.1 L+₹5.8 L (33.3%)Rejected-AOC 0 AJAY KUMAR 85 HASTAM HASTAM BANDA UTTAR PRADESH 210001 HASTAM BANDA UTTAR PRADESH 210001 UDYAM UP 13 0007628 | BANDA | UTTAR PRADESH | 210001 | L5 | Rejected-AOC REJECTED |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
20 Jan 2020, 6:00 pmClosed
G E ROORKEE
G E ROORKEE
REPAIRS MAINT AND REPLACEMENT OF LT PANNEL FEEDER PILLAR BOXES LT SWITCH GEARS AND OVER HEAD LINES UNDERGROUND CABLE AND OTHER CONNECTED WORKS IN POCKET 7 TO 8 AND PURKAZI UNDER GE ROORKEE
2019_MES_308650_1
8391/891/E8
Open Tender
Civil Works
Item Rate
180 days
ROORKEE CANTT
AS PER NIT
6 documents required · 6 mandatory
₹500
G E ROORKEE
₹50,000
Yes
25 Jun 2020
23 Dec 2019
21 Jan 2020
23 Dec 2019
20 Jan 2020
6 Jan 2020
Amount
M&L for removing all connections, bindings etc of ACSR/AAC conductor on existing LT poles & stretching of ACSR/AAC conductor upto required sag of any size and cross section of conductor and stretching of GI wire on existing pole including making necessary connection & binding with binding wire including cutting of tree branches from both sides upto the stress on each side complete all as specified and as directed by Engr-in-charge.
Supply & Fixing in replacement of existing PCC/Steel pole with new steel tubular poles complete with cast iron base plate, final taper, plug, bolts, nuts & washers as specified type 410 SP-31 (9.0 mtr long) including re-fixing of removed accessoreis such as ACSR/AAC conductor, cables, street light fittings, clamps, nuts & bolts etc complete all as specified and directed by Engr-in-charge.Note :- Excavation, MS work and PCC work will be measured and paid separately.
Taking down unsv pin type insulator and providing new pin type, porcelain vitreous white brown or green insulator including one galvanized mild steel spindles, two galvanized iron washers and one galvanized iron nut 100mm height, 65 mm dia for 1100 Volt grade complete all as specified. Make BHEL/Pactil/Rastriya/Jaipuria.
M&L for replacement of shackle type porcelain, vitreous white brown or insulator working under 1100 volts grade , pressure of height 75 mm & 90mm dia insulators, dia of bolt 12mm , section of straps 31 x 3mm, washers, nuts complete all as specified & directed. Make Pactil/BHEL/Rastriya//Jaipuria.
Taking down U/S stay assy and M&L for stay assy comprising of MS stay plate of size 23cmx23cmx6mm thick, stay rod with nuts 215cm ling 20mm dia , MS/GI stay bow 40cm lingh with 2 Nos GI thimbles, galvanized stay wire standard size 7/4mm of suitable length, loop insulation size 65x90mm clearance of hole 16mm & other accessories including excavation earth work & PCC work complete all as per SSR Pt-1 plate No-1 complete all as specified and directed by Engr-in-charge. Note : MS clamps will be measured & paid separately in respected items.
M&L for cleaning away all grass, vegetation, saplings, shrubs, undergrowth, roots and trees up to 50 cm girth from the area surrounding of E/M installations, under HT< over head lines, 4/2 pole structures, transforemer, installations, yards, surrounding valve chamers and removing the rubbish upto a distance 50 mtr outside the periphery of the area under clearance and dressing the area etc complete all as specified and directed by Engr-in-charge.
Taking down rusted/unsv mild steel work and M&L for mild steel work as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot , drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
M&L in replacement of cradles, hexagonal/ rectangular fabricated with galvanised steel wire of size 4mm dia complete all as specified and directed by Engr-in- charge.
M&L in repalcement of existing any type or any size aluminium conductor, steel reinforced including binding wire and jumper connect with PG clamp made out of aluminium alloy accodring to IS-617 complete all as specified and directed by Engr-in-charge.
Excavation in trenches/post holes in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for laying of pipes and for poles/stay and struts not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and directed.
Removing surplus spoil to a distance not exceeding 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified and directed.
Supply and laying sand river for cushioning with layers of sand 8 cm before lying of cable and 15 cm after lying of cable (total 23 cm) in trenches complete all as specified & directed. ( Note: Thickness after punning shall be measured for payment )
Supply and laying brick protection cable cover using sub class ‘B’ bricks laid flat adjacent to each other across the length of cable laid dry complete all as specified & directed by Engr-in-charge.
M&L for PCC work type D-2 (1:4:8) with 40mm graded aggregate for foundation to poles / stays/strutus or basements etc complete all as specified and directed.
M & L for cement concrete 1 :3 :6 type C-2 using 40 mm graded aggregate incl necessary form work all as specified.
M & L for PCC work type B-1(1:2:4) with 20 mm graded aggregate for coping to poles / stays/strutus or basements etc complete all as specified and directed.
Taking down old rusted galvanized iron pipe and providing galvanized pipe 80 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. Make: Jindal/ Tata steel / Prakash Surya.
Taking down old rusted galvanized iron pipe and providing galvanized pipe 40 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. Make: Jindal/ Tata steel / Prakash Surya.
Taking down old rusted galvanized iron pipe and providing galvanized pipe 32mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. Make: Jindal/ Tata steel / Prakash Surya.
Supply, laying & testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100V grade, cross sectional area as given below:- Make :Havells/Polycab/Finolex
(a) 3.5 core 120sq.mm.
(b) 3.5 core 95 sq.mm.
(c) 3.5 core 70 sq.mm.
(d) 3.5 core 50 sq.mm.
(e) 4 core 25 sq.mm
(f) 4 core 16 sq.mm.
(g) 4 core 10 sq.mm.
(h) 2 core 10 sq.mm.
Supply and fixing in replacement of existing panel mccb assessoriesd including making in coming /out going connections complete all as specified and directed :-
(a) MCCB rating 250 amp FP, Breaking capacity 36 kA.Make : Legrand/Havells/Simens/Indo Asian
(b) MCCB rating FP 200 Amp, 36 kA,Make : Legrand/Havells/Simens/Indo Asian
(c) MCCB rating FP 160 Amp, 36 kA ,Make : Legrand/Havells/Simens/Indo Asian
(d) MCCB rating TP 125 Amp, 25 kA, Make : Legrand/Havells/Simens/Indo Asian
(e) MCCB rating TP 100 Amp , 25kA,Make : Legrand/Havells/Simens/Indo Asian
(f) MCCB rating TPN 63 Amp , 16 kA, Make : Legrand/Havells/Simens/Indo Asian
(g) MCCB rating FP 100 Amp , 16kA. Make : Legrand or equivalent in Simens/ABB/Indo Asian
Supply and fixing for in replacement of LT 1100 volt Line rigid PVC spacers type 3 lines complete all as specified and directed by Engr-in-charge. Make : Rashtriya/Jaipuria Bros.
Supply and fixing for in replacement of LT 1100 volt Line rigid PVC spacers type 2 lines complete all as specified and directed by Engr-in-charge. Make : Rashtriya/Jaipuria Bros.
Supply and fixing for in replacement of LT 1100 volt Line rigid PVC spacers type 4 lines complete all as specified and directed by Engr-in-charge. Make : Rashtriya/Jaipuria Bros.
M&L in replacement of unserviceable switch air break gang operated triple pole mechanically operated mounted on HT 11KV outdoor for horizontal or vertical mounting insulators and mild steel galvanized frame with operating rod of 20mm bore medium grade galvanized iron pipe worked from ground level for current rating 200 Amps including nuts, bolts and washers etc of required size,having 9 insulators of capacity to suit the load at site including locking arrangement with locks and synthetic enamel paint over a coat of red oxide primer over mild steel work and electric connection complete all as specified and directed. Make : Pactil/ Jaipuria Bros/ Rashtriya.
M & L in repair sub main wiring with 2 single core, 6 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FRLS cable 1100 Volts grade incl 4 Sqmm PVC insulated unsheathed multi stranded copper conductor FR as continuous earth wire drawn through in existing surface/recessed steel/PVC conduit or PVC flexible sleevs connecting to common earth terminals complete all as specified and directed. Note :-(i) Two run of copper cable and one run of earth wire including conduit /PVC Casing/caping shall be measured as one length.
Taking down old rusted galvanized iron pipe and providing galvanized pipe 100 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. Make: Jindal/ Tata steel / Prakash Surya.
M&L earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.3 mm thick, burried directly in ground vertically in pit of size 900 x 900cm depth not less than 4.0 metre below normal ground level with top edge of the earth plate at a depth not less than 3.4 metre below normal ground level and covered surrounded from all sides with mixture of charcoal and common salt in alternate layers (each layer of 0.23 cu. m) upto 15cm above top of plate and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified. NOTE: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
M&L for replacement of unserviceable sheet metal enclosure power distribution board for independent mounting DRX 100 MCCB enclosure Make : Legrand cat part No . 607906,including 63 Amp four pole, 415 volt,10kA and including necessary connection complete all as specified and directed by Engr-in-Charge. Make: : Legrand cat part No.027029 or equivalent in Simens/C&S/Indo Asian
M&L for replacement of unserviceable sheet metal enclosure power TPN , 4 way, DPX3 160 MCCB enclosure distribution board, complete all as specified and directed by Engr-in-Charge. Make : Legrand cat part No . 607913 or equivalent in Simens/C&S/Indo Asian
S & F in replacement of u/s MCB TP 32 Amp, 415 Volt, 'c' curve including necessary connection complete all as specified and directed by Engr-in-charge. Make : Legrand cat part No.4086058 or equivalent in Simens/ABB/Indo Asian
S & F in replacement of u/s MCB SP 40 Amp, 415 Volt,'c' curve including necessary connection complete all as specified and directed by Engr-in-charge. Make : Legrand / Simens/Schenider/Indo Asian
Material and labour for preparation of old painted surcaces using polish paper painted exposed surfaces silver aluminium paint two coats to steel tubular pole of 11mtr including crossarms.Bracket etc complete with writing Nos of pole with white paint on black 3"dia circle all as directed specified complete.
Material and labour for preparation of old painted surcaces using polish paper painted exposed surfaces silver aluminium paint two coats to steel tubular LT pole upto 9 mtr including crossarms.Bracket etc complete with writing Nos of pole with white paint on black 3"dia circle all as directed specified complete.
Supply & fix Junction box of size 317mm X 265mm X 160 mm) wiith 32Amps MCB TPN(Make Legrand cat part No.408680 ) with the help of MS nuts bolts and MS clamps-1 Nos of size 40mm X 5mm thick with one No MCB SP 6 Amp (Make Legrand cat part No.4085 87) capacity and PVC cable 2.5 sqmm Aluminium wire upto 7.5 mtr length for connection of security light from junction box to light fitting and includes making suitable hole on existing pole to take out connections to fitting if required at site.Make : Sintex/Naptune/C&S./Legrand/Indo Asian
M&L for High Tension cable fault checking by high tension cable fault testing machine by disconnecting the HT cable end termination including insulation testing complete of faulty cable.complete all as specified and directed by Engr-in-Charge.
M & L for repairing/servicing calibrating Testing and recommissioning ACB, 1.1 KV, out door/indoor type, including replacement of Gasket set adjusting reconditioning stationery and moving contact adujsting link mechanism within limit nut bolt a, washer and required size of thimbles all as directed
Dismentaling of old steel tubular pole LT/HT after excavation of PCC and disconecting of cross arm and insulators,and shifting it to new location as required on site including all ACSR conductor any size/ cross arm/insulators connections including PCC work with ratio 1:3:6 and coping and testing of overhead line complete all as specified and directeded.
M & L and testing for end termination jointing kit suitable for 1100V, 16- 50 sqmm x 3.5 core XLPE cable heat shrinkable joint complete with jointing material & assessories suitable 1.1KV grade cable for end complete all as specified and directed
M & L and testing for end termination jointing kit suitable for 1100V, 70-120 sqmm x 3.5 core XLPE cable heat shrinkable joint complete with jointing material & assessories suitable 1.1KV grade cable for end complete all as specified and directed
M & L for XLPE grade cable for straight through joint kit suitable for 11KV, 70-120 sqmm, 3.5 core XLPE cable heat shrinable joint, complete all as specified and as directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for finding of the cable fault in underground cable and returning filling (including old bricks and sand) the same after rectification of the cable fault in any type of soil complete all as specified and directed.
Repairing/ Maint of LT over head lines and routine maintenance of electric supply/ current leakage / Under ground LT cables , servey for vegitation grought over and around of LT OH lines, Repair / Maintenance of LT feeder piller boxes , incl MCCBs / Timer switch , protection devices . electrical accessories in day to day maintenance and making it serviceable in all respect with all replacement of any major part but including small length of wires (not more than 50cm) adhesive cable and other connected major accessories. Work shall also include to check & removal of Vegitetion etc . Note:- (a) Contractors representative incl 01 x Electrician and 01x Mazdoor will report to Engr-in-charge/ JE E/M ( Ext Elect) daily at for noon and afternoon to collect routine/urgent works related to Ext Elecctric supply till completion of contract. The work shall be attended by the contractor immediately. The contractor will ensure availability of manpower equipped with all sort of petty items such as insulation tape, Jumpers , insulators , nuts, bolts, washers etc required to accomplish the job. The contractor will also ensure as availability of every type of requiste T&P and Mobile phone to his trades man. All routine/urgent jobs recived on job slip will be repaired & got signature of user's and will be deposited to JE E/M with in 24hrs. In case of any delay in attending the complaint more than 12hrs after handing over of routine/urgent works, the contractor shall be liable to pay the penalty as described in penalty caluse given here as under.
KISHORE CHAND DINESH CHAND
KOHLI CONSTRUCTION COMPANY
Balraj and Co
AJAY KUMAR CONTRACTOR
GLIBS CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .