| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹39.9 L+₹2.9 L (7.87%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹40.5 L+₹3.5 L (9.43%)Rejected-Finance 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹41.4 L+₹4.3 L (11.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹42.0 L+₹4.9 L (13.4%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
21 Sept 2022, 6:00 pmClosed
GE UTILITY AMBALA
GE UTILITY AMBALA CANTT 133001
REPAIR MAINT OF SPLIT ACs WINDOW ACs WATER COOLER REFRIGERATORS AND DESERT COOLERS INCLUDING ALLIED WORKS IN SECTOR C UNDER GE UTILITY AMBALA CANTT
2022_MES_541475_2
CA NO GE U AMB T 23 OF 2022-23
Open Tender
Civil Works
Item Rate
240 days
GE UTILITY AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹95,000
4 Oct 2022
30 Aug 2022
23 Sept 2022
30 Aug 2022
21 Sept 2022
7 Sept 2022
30 Aug 2022 - 3 Sept 2022
Amount
Providing services for attending all types of day to day complaints of maintenance, repair, replacement of unserviceable worn out spare parts, overhauling including soldering, spraying, chemical cleaning with detergents, leak repairing, charging fresh refrigerant, dismantling, reassembling and periodical services in respect of all make, work & type of Air Conditioners (window type, split type, cassette type and ductable type) installed at various locations in Ambala Cantt area by providing skilled qualified refrigerator mechanic cum electrician with helper per day alongwith required tools/equipments/machine/test kits/gas filling gauge, gas charging adopter, gas charging valve, drill machine with drill bit, allen key set, ladders, ropes ,clamp meter, brazing rod, butane gas cylinder, tape roll, vaccum pump, suction discharge valve, washing pump, spanner set, copper tube cutter, flaring tool, & other instruments which are required for maintenance, repair and to make the equipment functional and for keeping all equipments in perfectly clean, tidy and functional condition in all times and fixing the new compressor in original position and testing the same including supply and charging Refrigerant gas and fixing copper tube ,Capilary, over load relay, starting relay, filter making connection and put in working condition etc. complete all as specified and as directed by Engr-in-Charge. The complaints record to be maintained on the complaint register & complaint slips all as directed.
Providing services for attending all types of day to day complaints of maintenance, repair, replacement of unserviceable worn out spare parts, overhauling including soldering, spraying, chemical cleaning with detergents, leak repairing, charging fresh refrigerant, dismantling, reassembling and periodical services in respect of all make, work & type of Water coolers/Refrigerators/Deep freezers installed at various locations in Ambala Cantt area by providing skilled qualified refrigerator mechanic cum electrician with helper per day alongwith required tools/equipments/machine/test kits/gas filling gauge, gas charging adopter, gas charging valve, drill machine with drill bit, allen key set, ladders, ropes ,clamp meter, brazing rod, butane gas cylinder, tape roll, vaccum pump, suction discharge valve, washing pump, spanner set, copper tube cutter, flaring tool, & other instruments which are required for maintenance, repair and to make the equipment functional and for keeping all equipments in perfectly clean, tidy and functional condition in all times and fixing the new compressor in original position and testing the same including supply and charging Refrigerant gas and fixing copper tube ,Capilary, over load relay, starting relay, filter making connection and put in working condition etc. complete all as specified and as directed by Engr-in-Charge. The complaints record to be maintained on the complaint register & complaint slips all as directed.
Providing services for attending all types of day to day complaints of maintenance, repair, replacement of unserviceable worn out spare parts, leak repairing, dismantling including old wood wool pad, reassembling and periodical services in respect of all make, work & type of Desert Coolers installed at various locations in Ambala Cantt area by providing skilled qualified mechanic cum electrician with helper per day alongwith required tools/equipments & other instruments which are required for maintenance, repair and to make the equipment functional and for keeping all equipments in perfectly clean, tidy and functional condition in all times complete all as specified and directed by Engr-in-Charge. The complaints record to be maintained on the complaint register & complaint slips all as directed.
Note for Ser Item No 1.00 to 3.00 (i) Cost of spares including refrigerent for charging and rewinding /replacement of condensor fan motors,compressor,blower fan etc if required shall be measured and paid seperately under respective item of sch'A' as supply only being labour item is inclusive in the rate quoted for item. (ii) The Unit Rate quoted by the contractor shall deemed to be included for transportation charge, replacement of filter, cleaning of condenser Nuts & bolts, making necessary connection and testing complete. (iii) In case of multiple complaints to be attended on daily basis, the contractor will be liable to deploy adequate resources and manpower to attend the complaints in specified time frame failing which a recovery of Rs 200/- per complaint per day will be affected from the due payments of the contractor. Quoted rate shall be deemed to included. (iv) Complaint register shall be maintained in a Pucca Bound register and will be produced at the time of payment.
Supply only desert cooler body made of 20 SWG PGI sheet suitable for evaporative type desert cooler including side panel - 03 Nos of 20 gause PGI sheet and water tank height 20 cm & grill with fins including electrical wiring and connection with ON/OFF switch piano type with distribution PVC cup and elbow, PVC flexible pipe connection, PVC cable 3 core - 3 Mtr with top plug 5 Amps - 01 No including painting the complete body internally and externally, all side panels inner and outer side with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer complete all as specified and directed. Make: Khaitan/Crompton/J.K
Supply only cooler pump vertical/submersible type heavy duty single phase 50 Hz, 230 volt 1340 RPM, 18/20 watt suitable for evaporative type desert cooler complete all as specified and directed.
Supply only cooler motor of copper winding 480 mm sweep single phase three speed, 230 volt, 180 watt, 1400 RPM including fan blades, fixing clamps and capacitor complete all as specified and directed. Make: Crompton/Khaitan/Usha/Bajaj
Supply only 900 mm long PVC connections 15 mm dia bore with PTMT nuts complete all as specified and directed.
Supply only PVC Pipe 1/2 " with Elbow plastic as per exisiting length (set of three)
Supply only side panel for desert cooler made out of 20 SWG PGI sheet with MS handle duly painted as per existing (set of 3) all as specified and directed.
Supply only Wood wool pads of size- 700x700 mm (set of 3) of best quality with including wire netting (chicken wire mesh) as approved by Engineer-in-charge.
Supply only MS Front Show grill for desert cooler as per exisitng size at site.
Supply only Plastic front Show grill for desert cooler as per existing size at site.
Supply only distributor box PVC for desert cooler.
Supply only PVC blades for fan motor of desert cooler.
Supply only Capacitor 4/5 MFD suitable for desert cooler/water cooler. Make: Usha/Spicex/Tibcon/Epcos
Supply only plug top 3 pin 5A 230 volt complete all as specified and directed by Engr-in-Charge. Make: Cona/Anchor/Havells/Indo Asia
Supply only switch piano flush type 5/6A 230 volt complete all as specified and directed by Engr-in-Charge. Make: Cona/Anchor/Havells/Indo Asia
Supply only 3 pin 5/6 Amp plug top with main lead 2 yard length for Desert cooler. Make: Cona/Anchor/Havells/Indo Asia
Supply only Capacitor 6.0 MFD suitable for Air conditioner/water cooler. Make: Usha/Spicex/Tibcon/Epcos
Supply only starting Capacitor 80/100 Mfd. Make: Usha/Spicex/Tibcon/Epcos
Supply only Running capacitor 25/36 MFD for Window/Split type AC unit of Cap 1.5 TR/2 TR. Make: Usha/Spicex/Tibcon/Epcos
Supply only Running capacitor 45/50 MFD for Window/Split type AC unit of Cap 1.5 TR/2 TR. Make: Usha/Spicex/Tibcon/Epcos
Supply only Starting capacitor 100-120 MFD for Window/Split type AC unit of Cap 1.5 TR/2 TR. Make: Usha/Spicex/Tibcon/Epcos
Supply only Starting capacitor 120-150 MFD for Window/Split type AC unit of Cap 1.5 TR/2 TR. Make: Usha/Spicex/Tibcon/Epcos
Supply only Thermostate for air conditioner capacity up to 2.0 TR.
Supply only Starting Relay for AC capacity up to 2.0 TR.
Supply only Operating Knob for AC capacity up to 2.0 TR. Make: Carrier/Usha/Videocon/LG
Supply only company made new sealed unit compressor for window AC of Cap 2 TR with two years guarantee, Charging of Gas F-22/R-134A. Make: Kirloskar/Tachumsha
All as per item No. 31 here in before but Window Air Conditioner of Cap 1.5 TR. Make: Kirloskar/Tachumsha
All as per item No. 31 here in before but spilt type Air Conditioner of Cap. 2.0 TR. Make: Kirloskar/Tachumsha
All as per item No. 31 here in before but spilt type Air Conditioner of Cap. 1.5 TR. Make: Kirloskar/Tachumsha
Supply only air filter PVC type suitable for window type air conditioners of capacity 1 TR to 2 TR complete all as specified and directed.
Supply only air filter PVC type filter suitable for split type air conditioner of capacity 1.5 TR to 2 TR complete all as specified and directed.
Supply only remote control hand set for Window/ split AC of capacity 1.5/ 2.0 TR as per existing complete all as specified and directed
Supply only condenser fan blade for window AC of capacity 1.5/ 2.0 TR as per existing complete all as specified and directed Make- LG, Voltas, Carrier
Supply only condenser fan blade for split AC of capacity 1.5/ 2.0 TR as per existing complete all as specified and directed Make- LG, Voltas, Carrier
Supply of refrigerant gas R-22/R-32 in 10 kg cylinder complete all as specified and directed.
Supply of refrigerant gas R-134/R-410A in 10 kg cylinder complete all as specified and directed.
Supply only refrigerant copper tubing 1/4" & 1/2" with 22 SWG seperately alongwith insulation sleeves complete all as specified and directed.
Supply only refrigerant copper tubing 3/8" & 5/8" with 22 SWG seperately alongwith insulation sleeves complete all as specified and directed.
Supply only insulation for refrigerant copper tubing 5'8", complete all as specified and directed.
Supply only insulation for refrigerant copper tubing 3'8", complete all as specified and directed.
Supply only insulation for refrigerant copper tubing 1'2", complete all as specified and directed.
Supply only insulation for refrigerant copper tubing 1'4", complete all as specified and directed.
Supply only PCB of cooling unit of split AC 1.5/ 2.0 TR with electric accessories and sensors complete all as specified and directed.
Supply only PCB of cooling unit of window AC 1.5/ 2.0 TR with electric accessories and sensors complete all as specified and directed.
Supply only metal clad socket with two Pin and earth & plug top with one MCB SP 240 volt 32 Amp complete all as specified and directed. Make-Havells/Legrand/Standard.
Supply only MCB SP 240 volt 32 Amps complete all as specified and directed.
Supply only Lit lawn sheet 6mm thick and 1000 mm wide for Window/Split type AC unit of Cap 1.5 TR/2 TR
Supply only Copper filter double capillary pencil type for Window/Split type AC unit of Cap 1.5 TR/2 TR
Supply only Thermocool sheet 40x20 inch and thickness 20mm for Window/Split type AC unit of Cap 1.5 TR/2 TR
Supply only Wiring kit for A.C Window/Split Type 1.5/2 TR.
Supply only Platic louvers (Front panel) for Window AC 1.5/2 TR as per existing at site.
Supply only Suction and discharge valve set for Split type AC 1.5/2 TR capacity of any make as per exisiting
Supply only Reversible valve suitable for refrigerant R-22 for 1.5/ 2.0/ 3.0 TR AC including copper pipe.
Supply only new condenser coil of window Type AC Cap. 1.5 TR/2 TR of existing make and type from any location as directed by Engr-in- Charge.
All as per item No 60.00 here in before but for split type AC 1.5/2 TR.
Supply only Evaporator /Cooling coil for window type AC Cap. 1.5 TR /2 TR Cap of existing make and size all as directed by Engr-in- Charge.
All as per item No 62.00 here in before but for split type AC 1.5/2 TR.
Supply only Indoor unit Blower motor with bush 230 V, 50 Hz suitable for Split AC Cap 1.5/2.0 TR complete all as specified and directed. Make: LG/Carrier/Voltas/Blue Star
Supply only double shaft Blower motor 230 V, 50 Hz 1500 RPM suitable for Window AC Cap 1.5/2.0 TR complete all as specified and as directed. Make: Crompton / Kirloskar suitable for AC of make Fedder Lloyd/ Blue star/ LG/ Carrier/ Samsung
Supply only outdoor unit Cap 2.0 TR suitable for/compatible with Split AC indoor units of capacity 2.0 TR including PCB for automatic control, with copper condensor coil, condenser fan motor, fan blades,compressor,capacitor ,relay,connector etc with all other parts of outdoor unit (complete set) all as specified and directed.
Supply only condensing fan motor/ outdoor unit motor as per existing suitable for 1.5/2.0 TR split type AC complete all as specified and directed.
Supply only condensing fan motor as per existing suitable for 1.5/2.0 TR window type AC complete all as specified and directed.
Supply only Indoor unit as per existing suitable for/compatible with split AC outdoor unit of capacity 2.0 TR with evaporator coil/cooling coil, LCD display, PCB card, multi fan speeds, blower motor,auto air swing motor, filter,on-off timer ,inlet & outlet copper pipe, etc. with all other parts of indoor unit including remote control hand set complete all as specified and directed.
Supply only PVC insulated copper conductor cable of size 3 core, 1.0 sqmm, 1100 volt grade all as specified.
Supply only PVC insulated copper conductor cable of size 3 core, 1.5 sqmm, 1100 volt grade all as specified.
Supply only PVC insulated copper conductor cable of size 3 core, 2.50 sqmm, 1100 volt grade complete all as specified and directed.
Supply only compressor sealed unit of deep freezer of any make and type 230 V single phase capacity 500 ltr suitable for 500 ltr deep freezer of existing make complete all as specified and directed. Make: Kirloskar/Tachumsha
Description all as per item No 73.00 here in before but for 320 ltr capacity deep freezer and ditto.
Description all as per item No 73.00 here in before but for 205 ltr capacity deep freezer and ditto.
Supply only Thermostat switch with Knob for Refrigerator/Deep freezer of 165 to 500 ltrs capacity Make :- Indfoss/Renutrol
Supply only Starting relay 1/6 H.P. Open type with O.L.P. for Refrigerator/Deep freezer of 165 to 500 ltrs capacity Make : KOI / Whirlpool
Supply only Starting relay 1/8 H.P. open type with O.L.P. for Refrigerator/Deep freezer of 165 to 500 ltrs capacity Make : KOI / Whirlpool
Supply only copper filter single capillary pencil type for Refrigerator/Deep freezer of 165 to 500 ltrs capacity
Supply only Vegitable tray PVC suitable for Refrigerator of 165 to 500 ltrs capacity. Make Whrilpool, LG
Supply only Defrost tray suitable for Refrigerator of 165 to 500 ltrs capacity. Make Whirlpool/LG
Supply only PVC ice tray flexible of existing type, make and size for Refrigerator of 165 to 500 ltrs capacity.
Supply only Refrigerator bottle shelf suitable for Refrigerator of 165 to 500 ltrs capacity. Make Whirlpool/LG
Supply only Waste water tray for Refrigerator of 165 to 500 ltrs capacity.
Supply only Freezer door for Refrigerator of 165 to 500 ltrs capacity.
Supply only Door Lock for Refrigerator of 165 to 500 ltrs capacity
Supply only chiller tray for Refrigerator of 165 to 500 ltrs capacity.
Supply only ice tray for Refrigerator of 165 to 500 ltrs capacity.
Supply only Door switch for Refrigerator of 165 to 500 ltrs capacity.
Supply only Door handle suitable for Refrigerator of 165 to 500 ltrs capacity.
Supply only Refrigerator compartment Glass for Refrigerator of 165 to 500 ltrs capacity.
Supply only new compressor sealed unit suitable for 165 to 180 ltr Refrigerator & testing the same with two years gurantee. Make : Kirloskar/Whirlpool/Godrej.
Description all as per item No. 92.00 here in before but capacity of the refrigerator 280/ 300/310 Ltrs and ditto.
Supply only evaprotator/freezer of refrigerator, made out of aluminium suitable for 280/300/310 ltr capacity with freezer frame and door including connection of existing make.
Description all as per item No. 94.00 here in before but capacity of the refrigerator 165 to 180 Ltrs and ditto.
Supply only new compressor for water cooler of capacity 40-80 ltr. Make- Tecumseh/Copeland/Hitachi
Supply only new compressor for water cooler of capacity 120-150 ltr. Make- Tecumseh/Copeland/Hitachi
Supply only float valves 15 mm dia for desert cooler/water cooler with ball complete all as specified and as directed.
Supply only plug top 3 pin 15A 230 volt complete all as specified and directed by Engr-in-Charge. Make- Cona/Indoasian/Havells.
Supply only 15 Amp 3 pin plug top with 3 core copper main lead about 2 metre length
Supply only condenser fan motor 1/10, 1/16 HP of water cooler cap.150 Ltr single phase AC 220 V including reconnecting the electric connections and testing complete all as directed by Engr-in- Charge. Make : AE, Cromption Greaves / Cool Master.
Description all as per item No. 101.00 here in before but fan motor 1/32 HP and Water cooler of Capacity 40 Ltrs and ditto.
Supply only Drain hose pipe of length 05 metre for Air Conditioners/Water Coolers complete all as specified and as directed.
Supply only self closing taps of cast iron galvanised, chromium plated screwed for iron pipe suitable for water coolers complete all as specified and as directed. Make- JAGUAR/GEM/MARC
Supply only Over load protector device for 150 Ltr Cap. Water Cooler. Make: Sri Ram, Renutrol/Micro Tech
Supply only Over load protector device for 40 Lts Cap. Water cooler. Make: Sri Ram, Renutrol/Micro Tech
Supply only Starting relay open type/Box type suitable for 150 Ltr. Make: Sri Ram, Renutrol/Micro Tech
Supply only Starting relay open type/Box type suitable for 40 Ltr water cooler. Make: - Sri Ram, Renutrol/Micro Tech
Supply only Condenser fan blade plastic for fan Motor 1/10 and 1/16 HP for water cooler 40/150 ltr capacity.
Supply only Condenser fan blade plastic for Motor 1/32 and 1/35 for water cooler 40/150 ltr capacity.
Supply only Copper filter pencil type single / Double Capillary for water cooler 40/150 ltr capacity.
Supply only condenser coil fins type as per existing size & patterns for Water Coolers 150 ltrs capacity complete all as specified and directed by Engr-in-Charge.
Description all as per item No. 112 here in before but for water cooler 40 ltrs capacity and ditto.
Supply only complete Top door made out of stainless steel 20 SWG sheet with handle and locking arrangement with double keys including door gasket, insulation material, PVC inner sheet of suitable thickness for 150/40 Ltr capacity water cooler as per eixsiting size and shape, welding work, nuts, bolts & washers all directed.
Supply only GI Tubing 15 mm dia medium grade all as specified and directed by Engr-in-Charge. Make: JINDAL/TATA/PRAKASH/SURYA
Supply only stop vlave cast copper alloy screw down high pressure with crutch or butterfly handle screwed both ends for iron pipe 15 mm dia bore including complete all as specified and directed by Engr-in-Charge. Make: prayag/Shakti/Zoloto/Leader
supply only PVC self adhesive electrical insulation tape roll of Nominal- 0.125mm thicknessx 1.80 cm width x 25 m length
Supply only M-Seal Fast Curing Epoxy Compound Putty Sealant Adhesive For Leakage, Bonding, Gap Filling and Repairing (pack of 100 gm).
Supply only water tank made of 20 SWG PGI sheet suitable for evaporative type desert cooler of height 20 cm as per existing shape and size all as specified and directed.
Supply only Frost free thermostat for refrigerator of cap 310 litre and above
Supply only timer for refrigerator of cap 310 liter and above
Supply only kit for window type AC, comprising cooling/evaporator coil, condensing coil, blower motor (1.5 TR), thermostat, expansion valve, PCB plate and electrical accessories, testing complete all as specified and directed. Make: Opel/ LG/ Voltas/ Viva.
Supply only swing motor for 1.5 TR /2 TR split AC indoor unit for any type and make complete all as specified and as directed. Make: LG / Carrier / Voltas
Supply only suction valve size 3/8" for 1.5/ 2 TR split AC complete all as specified and as directed. Make:- BAP / TAK Cassel
Supply only discharge valve size 1/2" for 1.5/ 2 TR split AC complete all as specified and as directed. Make:- BAP / TAK Cassel
Supply only door gasket suitable for 300/625 ltr deep freezer doors complete all as specified and directed.
Supply only condensing coil for water cooler capacity 40/80L of any make all as specified and directed.
All as per item No 127 here-in-before but 60/120 ltr capacity.
Supply only condensing coil for refrigerator 160L all as specified and directed.
Supply only condensing coil for refrigerator 286/300 L all as specified and directed.
Supply only gas filter flair type ¾” x ½” flare for refrigerator of any capacity complete all as specified and directed.
Supply only of AC contactor three phase of capacity 25 Amp suitable for pillar type AC-3 TR complete all as specified and directed. Make : L&T/BCH/ABB
All as per serial item No 132 here in before but capacity 32 Amp suitable for 5.5 TR capacity ductable type AC complete. Make : L&T/BCH/ABB
All as per serial item No 132 here in before but capacity 40 Amp suitable for LG 8.5 TR capacity ductable type AC complete. Make : L&T/BCH/ABB
Supply only liquid line drier filter suitable for 8.5 TR ductale AC all as specified and directed. Make of drier filter: LG / Danfoss / Hitech
All as per item No 135 here-in-before but for 5.5 TR ductable type AC. Make: Amtrex/ Danfoss/ Indofos
All as per item No 135 here-in-before but for 3 TR pillar /cassette type AC. Make: Amtrex/ Danfoss/ Indofos
Supply only of air filter set suitable for 8.5 TR ductable split type AC complete all as specified and directed. Make : LG / Danfoss / Hitech
All as per item No 138 here-in-before but for 5.5 TR ductable type AC. Make: Amtrex/ Danfoss/ Indofos
All as per item No 138 here-in-before but for 3 TR pillar / cassette type AC.
Supply only of low / high pressure switch for 8.5 TR ductable split type AC complete all as specified and directed. Make : LG / Danfoss / Hitech
All as per item No 141 here-in-before but for 5.5 TR/3 TR ductable type AC. Make: Amtrex/ Danfoss/ Indofos
Supply only new three phase scroll compressor of capacity 3 TR all as specified and directed. Make : LG/ Danfoss/ Sanyo/ Tecumseh/Kirloskar/ Comipro/Copeland
All as per item No 143 here-in-before but new three phase scroll compressor suitable for 8.5 TR suitalbe for 8.5 TR ductable AC. Make : LG / Kirloskar / Tecumseh/Danfoss/Comipro/Copeland
All as per item No 143 here-in-before but new three phase scroll compressor of capacity 5.5 TR suitalbe for 5.5 TR ductable AC. Make : LG / Kirloskar / Tecumseh/Danfoss/Comipro/Copeland
M & L one coat of spray painting with synthetic enamel paint to refrigerator 165/310 lts cap including anticorrosive black paint on compressor, condenser coil Scratching out the existing paint with sand paper and filling up the scratches with putty complete all directed by Engineer-in- Charge.
Cutting the rusted unserviceable base of 150/40 Ltr Capacity. water cooler body, material and labour for fabrication of New Base made of MS sheet & angle iron as per existing size and thickness incl welding of small patches directed by Engr-in-Charge.
Taking out the Water Cooler Tank from water cooler 150/40 ltrs capacity & repair the tank with brazing welding etc to stop the leakage of tank incl replacement of glass wool tarpaulin sheet etc. Repair to cooling coil, refixing in original position, testing and commissioning complete all as specified and directed by Engr-in-Charge.
Scraping & removing the existing paint from old steel surfaces of water coolers capacity 150 /40 Ltrs by rubbing, preparing the surface smooth & applying two coats of synthetic enamel paint by spray gun machine of colour as approved by Engr-in-Charge.
M & L in replacement of 22 SWG MS sheet of water cooler, capacity 150/40 ltrs, including nut, bolts, screws, welding if required, painting with two coats of synthetic enamel grey paint over a coat of red oxide primer complete all directed by Engr-in-Charge.
Taking down voltage stailizer upto 5 KVA capacity of any make 250 volt for carrying out checking, overhauling including supply and replacement of the under mentioned defective parts of identical size and capacity complete with testing on load complete all as specified and as directed. :- Volt meter 0 to 300 volt
Relay transformer 12 volt
IC 240 volt 25 Amps
Rewinding of main transformer with existing size gauge of super enamelled copper winding wire and insulating materials complete all as specified and directed by Engr-in-Charge.
Operating switch push/knob type of voltage stabilizer
Indicating lamp of voltage stabilizer.
Taking out worn out existing 6mm/3mm thick ply wood and S&F 6.0 mm thick plywood for making air tight of desert coolers/air conditioners complete all as specified and directed by Engr-in-Charge.
M& L for painting of desert cooler body both internally and externally by spray painting with one coat of synthetic enamel paint of approved tint and colour over a coat of red oxide primer where required after cleaning the desert cooler body throughly with the help of emery paper and dry jute cloth removing the old peep out colour layer and rust making the surface even and smooth complete all as specified and directed by Engr-in-Charge.
M & L in replacement of angle iron stand for desert cooler/window AC made out of angle iron 40x40x5mm of required size with four legs and set of four angle for desert cooler for motor support with angle rubber, duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Marerial and labour for shifting of AC's any type/capacity from any height & location and refix the same on another location after making necessary cutting on wall/roof/window/glass/grills as per requirement of users, complete all as specified and directed by Engr-in-Charge. (Note:- Necessary insulation for copper tubing, gas filling, ply work shall be measured and paid seperately under respective item)
Material & Labour one coat painting with synthetic enamel paint on the body of window type AC/Split type AC outer body unit capacity 1.5/2 TR of any make and capacity with colour as per existing at site complete all as specified and directed by Engr-in-Charge.
M&L for repair of PCB of Indoor/Outdoor units of split AC's of capacity 1.5/2.0 TR including taking down, repair work, replacement of worn out spare parts, testing, refixing at site as per exsiting and re-testing upto complete satisfaction of Engineer-in-charge complete all as specified and as directed.
M&L for sub main wiring with two runs of single core, PVC insulated, unsheathed ,multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade and one run of 2.5 Sqmm PVC insulated earth continuity copper conductor cable drawn through and inculding suitable size of PVC concealed conduit with all necesary accessories such as bends, tees, junctions boxes, elbows etc complete with all in coming and out going cable connections complete all as specified and as directed. (Note : Two runs of 4 Sqmm cable, one run of 2.5 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one unit length).
Disconnecting electric connection from defective blower motor and taking out from window type/ split AC outdoor unit capacity 1.5/2 TR of existing make and transporting to store yard of Refg AC Section, then to be transported to contractors workshop after getting the gate pass from Engineer-in-Charge. Dismantling the burnt winding & rewinding of 1/6 to 1/8 HP double shaft blower motor with the existing size of super enemelled copper winding wire including insulation, varnishing, greasing, testing complete and transporting back to the location from where it was disconnected and refixing the same and testing complete all as specified and as directed.
Taking out of defective wiring of indoor/ outdoor unit, PCB, visual eye damp plates, unserviceable cordless electronic remote control and fixing the new wiring, cordless electronic remote control, PCB, visual eye damp plate in place of damaged items of split AC of capacity 1.5 TR/ 2TR including matching the existing system all as specified and as directed. Make of AC & remote: Carrier/ LG/ Hi series/ Samsung.
Note:- Amount of credit of Rs. 399780.00 for retrieved materials is mentioned in Schedule of Credit attached in tender documents in pdf form which will be deducted offline while acceptance of tender.
M/S HANDAENTERPRISES
M/s badrinath Traders
BANSAL ENGINEERING
kapil enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .