| 1 | L1₹21.8 LAccepted-AOC COLLEGE CHOWMUHANI JIRANIA WEST TRIPURA | ₹21.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹23.2 LRejected-Finance JATAN BARI KARBOOK | GOMATI | TRIPURA | 799104 | ₹23.2 L | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | Asish Debnath L1 | RATAN PAUL L2 |
|---|---|---|---|---|---|
| 1.00Supply of the following : | |||||
| 1.01 | 9 mtr long PCC Pole | 32 | No | 6,785 ₹2.2 L | 6,500 ₹2.1 L |
| 1.02 | 8 mtr long PCC Pole | 6 | No | 4,838 ₹29,028 | 6,000 ₹36,000 |
| 1.03 | MS Stay set complete | 44 | Set | 849.6 ₹37,382.40 | 650 ₹28,600 |
| 1.04 | Stranded stay wire (7/2.5 mm) | 220 | Kg | 70.8 ₹15,576 | 65 ₹14,300 |
| 1.05 | Stay Insulator (HT) | 38 | No | 59 ₹2,242 | 100 ₹3,800 |
| 1.06 | Stay Insulator (LT) | 6 | No | 47.2 ₹283.20 | 70 ₹420 |
| 1.07 | ACSR (6/1/2.59 mm dia) weasel conductor | 6.12 | Km | 26,904 ₹1.6 L | 27,800 ₹1.7 L |
| 1.08 | 8 SWG GI Wire | 0.35 | MT | 70,800 ₹24,780 | - |
| 1.09 | 11 KV Polimeric Pin Insulator i/c. GI Pin | 96 | No | 194.7 ₹18,691.20 | 200 ₹19,200 |
Tender Value
₹31.2 L
EMD Value
₹52,845
Closing Date
26 Sept 2025, 2:00 pmClosed
Deputy General Manager ED Manu LTV Dhalai Tripura.
Manu Electrical Division LTV Dhalai Tripura
Extension of HT/LT line i/c. installation of 63/100 KVA DT for segregation and providing 3-phase service connection to the Different DTW Schemes within the jurisdiction of ESD - Manu and ESD - Chawmanu under ED - Manu, LTV., Dhalai District.
2025_POWER_65742_1
DNIT NO DGM ED MNU 2025 26 08
Open Tender
Electrical Works
30 days
Extension of HT/LT line i/c. installation of 63/10
AS per BID Documents.
2 documents required · 2 mandatory
₹2,000
Yes
₹52,845
Yes
Manu Electrical Division LTV Dhalai Tripura.
3 Feb 2026
20 Sept 2025
7 Oct 2025
20 Sept 2025
26 Sept 2025
20 Sept 2025
20 Sept 2025 - 20 Sept 2025
23 Sept 2025
Amount
Supply of the following :
9 mtr long PCC Pole
8 mtr long PCC Pole
MS Stay set complete
Stranded stay wire (7/2.5 mm)
Stay Insulator (HT)
Stay Insulator (LT)
ACSR (6/1/2.59 mm dia) weasel conductor
8 SWG GI Wire
11 KV Polimeric Pin Insulator i/c. GI Pin
11 KV Polimeric Disc Insulator
11 KV Disc Fittings
11 KV, 200 Amps GOS 3-phase.
11 KV DOF Set, 3-phase.
9 KV, 5 KA single pole metal oxide gapless type Lightening Arrestor.
100X50X50X6 mm MS Channel (Galvanised).
75X40X40X6 mm MS Channel (Galvanised).
65X65x6 mm MS Angle (Galvanised)
LT Shackle Insulator 3"X3.5" size
Polythin pipe, 1/2" dia
95 sqmm. Bi-metallic Lugs
70 sqmm. Bi-metallic Lugs
LT Straps with Nuts & Bolts
Nuts & Bolts (Assorted Size)
70 sq.mm PVC Cable
35 sqmm PVC Cable
10 sqmm PVC Cable
200 Amp Cut-Out
100 Amp Cut-Out
Supply of fabricated bracket clamps of assorted size of 50X6 mm MS Flat i/c. holes as per requirement by Drill Machine.
Supply of fabricated stay clamp i/c Nuts & Bolts etc as required
11 KV Danger plate
Barbed wire
Earth Spike
Wooden plank (AS)
Numbering of Poles & DT
2.5 mm G.I pipe earthing for line & S/S
supply of 60 Kg Salt, & 55 Kg Charcoal (for 1 Pit) for Sub station Earthing.
Dismentle of the following :
9.00 Mtr. Long PCC Pole
9.00 Mtr. Long steel Pole
8 mtr. long PCC Pole (highly Inclined)
SP Top X-arm of 0.3 Mtr. Long MS Channel of Size 75x40x40x6mm
SP bottom X-arm of 1.2 Mtr. Long MS Channel of Size 75x40x40x6mm
SP Gaurd X-arm of 1.6 Mtr. Long MS Angle of Size 65x65x6 mm.
DP Top X-arm of 2.2 Mtr. Long MS Channel of Size 75x40x40x6mm.
DP Top Guard X-arm of 2.5 Mtr. Long MS Channel of Size 65x65x6 mm.
11KV Polymer Disc insulator with fittings
11KV Polymetric Pin Insulator
Stay Set Complete
A.C.S.R. (6/1/2.59 mm)
GI Wire (8SWG)
Cradle Guard
4-wire LT bracket(01.10mtr.long of M.S.Angle-50X50X6mm)
2-wire LT bracket(0.6 mtr.long of M.S.Angle-50X50X6mm)
LT Shackle Insulator(3X3.5)" size with straps, Nuts & Bolt
Stratening of 9 Mtr Long PCC Pole
Re-stringing of conductor A.C.S.R-(6/1/2.59 mm) including binding, hoisting, jumpering etc as required.
Re-adjustment of stayset complete without dismentalling turn buckle.
Erection of the following :
9.0 mtr. long PCC Pole.
8.0 mtr. long PCC Pole.
Erection of painted Stay Set complete direct in earth with 16 mm. dia. 1.8 mtr. long painted stay rod, anchor plate of size 300 X 300 X 8 mm. thick, turn buckle of length 356 mm. with 300 mm. long threaded adjustable 16 mm. dia. MS rod , thimble, guy insulator as per IS specification, hot dip (heavy duty) galvanized stay stranded wire of size 7/2.5 mm. fastened with stay clamps as required. ( including supply of MS clamp & Nuts & Bolts as reqd) and Grouting of stay set with CC of ratio 1 :2:4 (1 cement: 2 river sand: 4 jhama brick aggregate of 20 mm. nominal size) ilc supply of cement, sand and brick aggregate complete with excavation, refilling of earth, ramming along with centering and shuttering as required ( @ 0.119 Cum per stay set as per TSECL Specification)
Laying, hoisting & stringing of ACSR (6/1/2.59 mm) Weasel Conductor including binding, jumpering, etc. as reqduired & as per direction of the Engineer-in-Charge.
Laying, hoisting & stringing of 8 SWG G.I. wire as per ISS : 280/1978 amended latest with heavy coating as per ISS : 4826 I 1968 of tensile strength 55 to 95 Kgf/mm i/c fastening with cross arm & metallic parts for earth continuity wire and metal parts to earth electrode as per direction of the Engineer-in-Charge.
Erection of 11 KV Polimeric Pin Insulator including G.I Pin for 11 KV system with mechanical strength of 10 KN conforming to ISS:731/1971 with hot dip galvanized M.S forged 11 KV G.I pin alongwith galvanized hexagonal nuts, G.I flat washer and G.I spring washer conforming to ISS: 2486(P-II)/1974 etc. as required in complete as per direction of the Engineer-in-Charge.
Erection of Polimeric Disc Insulator Ball and Socket type i/c fittings for 11 KV system (EMS-45 KN) conforming to ISS:731/1971 in angle and dead end locations including tension fittings of EMS-45 KN to accommodate the relevant ACSR conductor size along with nuts and bolts, washer etc. as required in complete as per direction of the Engineer-in-Charge.
Erection of 11 KV, 200 Amps. 3-phase GO Switch complete i/c fixing horizontally & vertically operating pipe & operating handle with nuts & bolts etc. as required.
Erection of 11 KV 3-phase DO Fuse complete with nuts & bolts etc. as required.
Erection of 9 KV, 5 KA single pole metal oxide gapless type Lightening Arrestor i/c. necessary connection complete as per direction of the Engineer-in Charge.
Erection of 2.8 mtr. long made of 75 X 40 X 40 X 6 mm. MS Channel for Sub-Station GOS, DOF bracket as per direction of the Engineer-in-Charge.
Erection of 0.3 mtr. long made of 75 x 40 x 40x 6 mm. MS Channel for single pole top bracket as per direction of the Engineer-in-Charge.
Erection of 1.2 mtr. long made of 75 x 40 x 40x 6 mm. MS Channel for single pole bottom bracket as per direction of the Engineer-in-Charge.
Erection of 1.7 mtr. long made of 75 x 40 x 40x 6 mm. MS Channel for Doubble pole top bracket as per direction of the Engineer-in-Charge.
Erection of 2.2 mtr. long made of 75 x 40 x 40x 6 mm. MS Channel for Doubble pole bottom bracket as per direction of the Engineer-in-Charge.
Erection of 2.8 mtr long made of 100x50x50x6 mm. MS Channel for transformer base as per direction of the Engineer-in-Charge.
Erection of 0.8 mtr long made of 100x50x50x6 mm. MS Channel for transformer base as per direction of the Engineer-in-Charge.
Erection of 2.5 mtr long made of 65x65x6 mm. MS Angle for two pole guard bracket. as per direction of the Engineer-In-Charge.
Erection of 2.8 mtr. long made of 65x65x6 mm MS Angle for GOS handle, DOF bracket as per direction of the Engineer-in-charge.
Erection of 1.5 mtr long made of 65x65x6 mm. MS Angle for single pole guard bracket. as per direction of the Engineer-in-Charge.
Erection of 1.2 mtr long made of 65x65x6 mm. MS Angle for LT Line bracket. as per direction of the Engineer-in-Charge.
Erection of Porcelain Shackle Insulator (90X75mm) for LT system with mechanical strength of 5 KN conforming to ISS:731/1971 with hot dip galvanized M.S G.I Straps with bolts in complete (suitable for Rabbit/DOG conductor) as per direction of the Engineer-in-Charge
Earthing with GI pipe 2.5mtr long and 40 mm dia, including excavation, refilling with alternate layer of salt and charcoal as per drawing (excluding supply of GI pipe, salt and charcoal, GI wire, Nuts & bolts etc. As required).
Supply and erection of earthing set as per ISS : 3043 of 1966 and with latest amendment if any, 2.5 mtr long G.I. pipe (ISI marked) of 40 mm diameter with suitable holes on pipe circumference including a pair of clamps (made of 50 X 6 mm M.S. flat), galvanized nuts & bolts along with alternate layers including supply of salt & charcoal, 4.0 mtr long, 12mm dia PVC pipe for each earthing set etc. as required and as per direction of the Engineer-in-Charge.
Erection & commissioning of 100 KVA, 50 HZ, outdoor type 11/0.433 KV AC Distribution Transformer on Sub-Station Channel base at a height of 2440 mm (approx) above Ground Level with required connection by ACSR from 11 KV line to Transformer via GOS & DOF fastened straining screw, clamp, nuts & bolts as required as per Technical Specification.
Erection & commissioning of 63 KVA, 50 HZ, outdoor type 11/0.433 KV AC Distribution Transformer on Sub-Station Channel base at a height of 2440 mm (approx) above Ground Level with required connection by ACSR from 11 KV line to Transformer via GOS & DOF fastened straining screw, clamp, nuts & bolts as required as per Technical Specification.
Erection of 70 sq. mm PVC Cable i/c fitting fixing 100 ampere cut out on wooden plank making connection from Transformer LT side to overhead LT Line via fuse unit of unarmored PVC cable 1100-V grade conforming to ISS: 1554 (P-I) /1988 of the following sizes and the cables shall be properly crimped by bi-metallic lugs at contact areas as per direction of the Engineer-in-Charge. (Karai Wooden Plank 500X300X25 mm will be supplied by the Contractor)
Drawing of 3-phase service line by PVC insulated Aluminium conductor with GI Wire and Reel insulator i/c. fixing and commissioning of 3-phase Energy Meter & meter cut outs etc. as required.
Fabrication of cross arm by MS Channel/Angle as per Specification by Drill Machine.
Erection of 11 KV Danger plate
Erection of Barbed wire
Erection of Cradle guard
Providing Sub-Station protective fencing made by chain link mesh of 8 SWG GI Wire of size 2X3 mtr. And height 1.5 mtr. as per engineer requirement by 65X65X6 mm MS Angle post of height 2 mtr. Horizontal bar 2X3 mtr and 2X2 mtr. And top angle posts by 50X50X6 mm MS angle and two part MS Grill door of size 1.2X1.4 mtr with locking arrangement i/c necessary grouting and painted AL paint over red oxide priming of approved quality as required as per Technical Specification.
Sub-Station Name plate in/c supply as directed by Engg- in -charge.
Jungle Cutting and Trimming for new Line.
Carrying of the following :
Carrying of the line materials and transformer etc. from Electrical Store Sub-Division, AD Nagar, Agartala to work site by mechanical transport i/c loading unloading & stacking etc. as per direction of the Engineer-in-Charge.
63 KVA Transformers
100 KVA Transformers
Survey, route alignment & pole spotting, preparation of survey report and uploading in the web portal after approval of Project Manager
RATAN PAUL (BID ID -189611)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid