Loading…
Loading…
Tender ID
Tender Value
₹5.4 L
EMD Value
₹13,480
Closing Date
16 Mar 2026, 10:00 amClosed
Assistant Engineer
Alakode Grama Panchayath
Re- E-TENDER - Alakkode Grama Panchayat-Generator for Thimiri Crematorium-and Electrical connection.-General Electrical Work
2026_LSGD_844268_8
9-E-TEN/ALKD/2025-2026
Open Tender
Electrical Works
Item Rate
120 days
Alakode
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,190
Yes
₹13,480
Yes
6 Mar 2026
6 Mar 2026
18 Mar 2026
6 Mar 2026
16 Mar 2026
6 Mar 2026
wiring
OD393083/2025-2026:Supply, Loading, Conveyance, unloading, and erection of 15 KVA DG Set with Acoustic enclosure as per CPCB 4+norms and as detailed below. 1. Engine- a. Make of engine - Kirloskar, Mahindra, Ashok lyleand, Cumins b. Type of Engine - Diesel Engine. c. No of Cylinders - As per manufactures standard. d. Method of cooling - Water cooled with radiator. e. Aspiration - Naturally Aspirated. f. Design - Suitable for generating set operation. g. Output - Suitable for generating set operation. 2. Standard accessories with Diesel Engine a. Fly wheel. b. Close Coupled. c. Air cleaner. d. Radiator with fan provided with fan guard. e. Fuel Pump. f. Mechanical /Electronic governor. g. Fuel filter. h. Lubricating oil filter. i. Residential type exhaust silencer. j. Battery Charger / Generator. 3. Engine Instrument Panel with the following items. a. Starting switch with key or button and Remote control b. Lubricating oil pressure gauge. c. Water temperature gauge. d. RPM Indicator with hour meter. e. Battery charging ammeter. 4. Safety Controls for Engine a. Battery control (trip) for low lubricating oil pressure. a. Battery control (trip) for high water temperature. 5. Brush less alternator a. Make - Kirloskar/ KEL/Stamford/Crompton/Integrated electric Ltd b. Type - Self exited and self regulated c. Capacity - 15 KVA / 12 KW @ 0.8PF d. System of Voltage - 3Phase, 415V, 4 Wire system. f. Speed - 1500 rpm. g. Frequency - 50Hz. h. Insulation - Class F/H The alternator should confirm to IS 4722/IS13365. Operation and service manual shall be provided 6. Fuel Tank Suitable size fitted (built in type) inside the acoustic enclosure 7. Battery Suitable size fully charged battery with leads and terminals of appropriate AH capacity as per Manufactures required including battery charger. 8. Standard control panel a.32 A 4 Pole MCCB Set at 25 A b. 1No multi function meter suitable for display of current in 3Phases, voltage in 3 Phases, frequency, power factor, KVA, KVAh, KVAr, KVArh, KW etc. c. 1 No separate KWH meter d. Necessary measuring CTs of appropriate ratio and burden for the required meter. d. Instrument fuse/MCB - 2set f. Metallic DNB - 1No g. Solid state phase indication lamp for supply ON/OF with Fuse / MCB protection.
OD393082/2025-2026:Supply conveyance installation testing and commissioning 32 A, 4 pole On-Load Change Over Switches In SS Enclosure and giving connection as required
2.24.1:Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 4 way, Double door TPN MCBDB
OD393080/2025-2026:Supply and Providing LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
1.17.5:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
OD393077/2025-2026:Supply of High speed Speed Diesel for test run
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD393075/2025-2026:Supply and providing test joint for the earthing system using 2 x 25 x 3 mm GI strip including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required
OD393079/2025-2026:Supply and providing earth lead from the test joint to the earth electrode using 25 x 3 mm GI strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
OD393086/2025-2026:Supply and providing the 25 x 3mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
OD393076/2025-2026:Supply and installation of ABC type fire extinguisher of 6 kg. Capacity complete with initial charges and installation brackets, with ISI mark IS:15222.
OD393078/2025-2026:Supply and providing 2 mm thick & 1 m wide electrical grade chequered type insulation mat to withstand 3.3 KV dielectric strength conforming to IS 15652/06
90.3.17.3:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.50 mm dia GI pipe
OD393081/2025-2026:Charges for preparation and submission of documents such as plan,scheme etc for approval of Generator installation from KSELB& KSEB (Excluding CD Charge)
OD393084/2025-2026:Statutory Fee and other deposit amount to KSELB & KSEB for approval from the concerned department for generator installation. (LS provision as per the receipt)
90.2.1.15:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Long Point
90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.3.18.1:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps
OD393103/2025-2026:supply,Conveyance, installation, testing and commissioning of ornamental wall light fittings robust &reliable LED Bulk head with IP 65 protection and IK 08 impact resistance(Philips make Model WT140W LED 7S CWPSU S1C-9405)or any other equivalent make directly on wall including giving Connections with required length of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
BOQ_1426085.xls
BOQ • 0.32 MB
NIT.pdf
Tender Documents • 0.03 MB
SBD.pdf
Tender Documents • 1.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .