Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-AOC CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | ₹9.3 L Quoted ₹9.4 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹10.5 L+₹1.2 L (12.6%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | ₹10.5 L+₹1.2 L (12.6%) | L2 | Rejected-Finance Rejected due to bidder is not L1 |
| 3 | L3₹12.6 L+₹3.2 L (34.7%)Rejected-Finance | ₹12.6 L+₹3.2 L (34.7%) | L3 | Rejected-Finance Rejected due to bidder is not L1 |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
6 Oct 2020, 6:00 pmClosed
Sh K A Vardhan, IDSE
Office of the GE (Army) Camp Hanuman, Ahmedabad - 380 004
REPAIR REPLACEMENT OF INTERNAL ELECTRIFICATION WORKS IN MD OTM ACCN UNDER ZONE A AREA AT AHMEDABAD CANTT
2020_MES_375726_1
8118/E8
Open Tender
Civil Works
Item Rate
270 days
GE (Army) Ahmedabad
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (Army) Ahmedabad
₹20,000
Yes
2 Feb 2021
8 Sept 2020
8 Oct 2020
8 Sept 2020
6 Oct 2020
22 Sept 2020
8 Sept 2020 - 22 Sept 2020
Amount
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete.
M&L for point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed modular steel terminal boxes of thickness not less than 1.2 mm covered with suitable and required size of modular box, plate with cover for mounting switches, sockets, fan regulators complete including making good the wall surfaces with matching colour on wall for the following:- Note : Cutting chases,pinning in ,making good for facings where required will be measured and paid separately.
One light point controlled by one switch.
One fan point controlled by one switch.
One light point controlled by two, two way switches.
One socket outlet 6 amp controlled by one switch on the same board with other switches.
One socket outlet 6 amp controlled by one switch on indepdendent board.
One bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 4 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with suitable and required size of modular box, plate with cover complete for one 16 amp socket outlet controlled by one switch on independent board including making good the wall surfaces with matching colour on wall.
S&F modular switch one way 6 amp 1 module.
S&F modular switch one way 16 amp 1 module.
S&F modular switch two way 6 amp 1 module.
S&F modular bell push, 6 amp, 1 module.
S&F door bell, AC, 240 volts, single pole complete.
S&F modular socket 6/16 - 2/3 pin combined 2 module.
S&F modular socket 6 amp 2/3 pin combined 2 module.
S&F modular hum free electronic step fan regulator, 100 watt 2 module.
M&L for point re-wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including PVC casing-caping not less than 32x12 mm ISI marked ivory colour with all fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators complete for the following:-
One light point controlled by one switch.
One fan point controlled by one switch.
One socket outlet 6 amp controlled by one switch on the same board with other switches.
One socket outlet 6 amp controlled by one switch on indepdendent board.
One bell point controlled by one bell push.
One light point controlled by two, two way switches.
M&L for point re-wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 2.5 sqmm (Green) drawn into and including PVC casing-caping not less than 25x12 mm ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover complete for one 16 amp socket outlet controlled by one switch on independent board.
S&F angle holder, insulated polycabonate body with back plate complete.
S&F switch piano flush button single pole one way 6 amp complete.
S&F switch piano flush button single pole one way 16 amp complete.
S&F switch flush type, 6 amp, single pole, two way complete.
S&F bell push, flush type, 6 amp 240 volts complete. Make -
S&F socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete.
S&F ceiling rose 3 plates polycarbonate body complete.
S&F hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FR-LSH multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories of following nominal sizes:-
2x4 sqmm + 1x4 sqmm earth wire in 20 mm dia conduit.
2x6 sqmm + 1x6 sqmm earth wire in 25 mm dia conduit.
2x10 sqmm + 1x10 sqmm earth wire in 25 mm dia conduit.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FR-SH multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into into including PVC casing-caping not less than 25x12 mm ISI marked of following nominal sizes :-
2x4 sqmm + 1x4 sqmm earth wire.
2x6 sqmm + 1x6 sqmm earth wire.
2x10 sqmm + 1x10 sqmm earth wire.
S&F LED Smart bright batten (4 Ft ) made of Aluminium housing integrated LED driver with a PC glossy difusser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not less than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete. Make : Havells (Lumiline) /C&S/Wipro/ GE Lighting as approved.
Supply and Fix in replacement existing unsv sleek LED mirror light fitting 2 feet long 1x10 W including LED tube 2 feet long of same make having ballast, bipin holder, connector block etc complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed.
S&F LED wall washer aluminium soft rounded corners in rectangle shape and white colour of light in both the up and down directions IP 44 ratings for uses in interiors as well as exteriors complete with 7 Watt LED luminaries incl connecting all as directed. Make : Philips, Model No : 34153 or equivalent in Havells / GE Lighting/C&S as approved.
S&F energy efficient recessed mounted LED luminaire 36 Watt suitable for 2'x2' grid ceiling with flat diffuser and lumen output of 3300 lumens having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable in renewal of any type luminaire as required.
S&F in renewal 20 amp, single pole and neutral, socket outlet, with 2 pole and earth, metal enclosed plug top in power coated CRCA steel sheet enclosure recess mounted with chained cover for the socket outlet with and including one number single pole 'C' series MCB 16/20 amp as required. Make - Legrand cat ref no 607841 & 408592 / 408593 or equivalent in Indoasian Cat Ref No 811956 & 811149 or Hager as approved.
Supply & Fixing for sheet metal enclosure MCB distribution board, double door with IP43 -IK09protection single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification.
Supply & Fixing for sheet metal enclosure MCB distribution board, double door with IP43 -IK09protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification.
Supply & Fixing for sheet metal enclosure MCB distribution board, double door with IP43 -IK09protection single phase 240 volts 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification.
S&F MCB distribution board ETPN, 415 volts, 4 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required. Make : Ligrand/Havells/Standard
S&F MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:-
Single pole 6 to 32 amp.
Double pole 10 to 32 amp.
Double pole, 40 to 63 amp.
Four pole 40 to 63 amp.
Note for MCBs & MCB DBs:- MCBs & MCB DBs shall be of the same make.
Taking down MCB distribution boards with incoming and outgoing controls any make, any capacity after disconnecting complete.
Taking down carefully aluminium or copper submain wiring with PVC casing caping / PVC surface conduit and making good disturbed surfaces complete.
Supply and fix in replacement of Surge protection device Single phase of rating 10KV/KA for Distrubution board complete all as specified and directed. Make : As per approved by GE.
ALBA AC AND REF SERVICES
Vardaini Industries
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .