| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.1 LAccepted-AOC HOUSE NO 3809 SAMRIDHI HOMES PEERMAUSHALA POST DHAKOLI MC ZIRAKPUR DISTT SAS NAGAR PIN 160104 | S A S NAGAR | PUNJAB | 160104 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹19.5 L+₹1.4 L (8.00%)Rejected-Finance 363 39KA HASSANGANJ BAWLI KUMAR COMPANY 363 39 KA HASAN GANJ BAWLI SAADAT GANJ LUCKNOW SAADATGANJ | L2 | Rejected-Finance Other Than Lowest Bidder | |
| 3 | L3₹21.7 L+₹3.6 L (20.2%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L3 | Rejected-Finance Other Than Lowest Bidder | |
| 4 | L4₹21.8 L+₹3.8 L (21.0%)Rejected-Finance HOUSE NO 3363 SECTOR 27 D CHANDIGARH | NA | NA | 160001 | L4 | Rejected-Finance Other Than Lowest Bidder | |
| 5 | L5₹22.4 L+₹4.3 L (23.8%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L5 | Rejected-Finance Other Than Lowest Bidder |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
10 Nov 2022, 6:00 pmClosed
GE Chandigarh
GE Chandigarh N area PIN-160003
PROVSN OF GEYSERS IN TYPE C AND C (RE) QUARTERS AND PROVSN OF FIRE FIGHTING SYSTEM IN 2x TYPE IV SPECIAL QUARTERS AT DAD COLONY AT SECTOR 35B UNDER GE CHANDIGARH
2022_MES_557539_1
GE/CHD-57/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chandigarh
Class E category b(i) for contractor enlisted in MES
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹48,000
Yes
26 Dec 2022
13 Oct 2022
12 Nov 2022
13 Oct 2022
10 Nov 2022
29 Oct 2022
14 Oct 2022 - 23 Oct 2022
Amount
Supply and fix Electric water Heater, storage type heating element upto 2 KW capacity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, including fastner, pinning in making good where required in cement mortar 1:3 to the distrubed surfaces etc complete all as specified and directed by Engineer-in-Charge.
S&F GI pipes 15mm bore ISI marked medium grade with all fittings concealed in wall including cutting and chasses in brick work and fixing with clamp complete all as specified and directed by Engineer-in-Charge.
M&L for cutting & screwing existing steel tubing 20/15mm dia bore size for alternations or additions required for connection with inlet pipe of Geyser complete all as directed at site.
S&F PVC connection 450mm long for cold / hot water heavy duty made out of double layer at Nylon & wire fabric at pressure 06Kg / Sqcm both side, CP brass 15mm bore coupling or nuts.
S&F angle stop valve 15mm bore heavy duty fancy type chromium plated with long shank and cup concealed in wall etc complete all as specified and directed by Engineer-in-Charge.
S&F 15mm dia fancy type, Bib taps, cast copper alloy with crutch or butterfly handle screwed down for iron pipe or for brass ferrule and fixed of etc complete all as specified and directed by Engineer-in-Charge.
M&L point wiring using approved colour coding as per IS with copper conductor 2.5 Sqmm (Nominal Area) PVC insulated unsheathed, multi stranded copper cable single core in & including rigid non-metallic PVC concealed conduits 25/20mm dia ISI marked with two nos sunken pressed steel terminal boxes for mounting of switch & socket separately and socket controlled by independent switch 15 Amp including 3mm thick hylum sheet phonetic laminated with 2.5 Sqmm PVC insulated unsheathed multi stranded copper conductor single core cable of green colour as continuous earth wire connected to common earth and earth dolly for socket earthing complete all as directed.
S&F switch piano type single pole 15 Amps etc complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet 3 pin 15 Amps shuttered type etc complete all as specified and directed by Engineer-in-Charge.
M&L for coloured ceramic glazed ceramic tiles in vertical surface 450X 300X 7-8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade/colour of tiles,over and including 10 mm thick rendering in CM (1:3) , after dismantling the existing tiles complete all as specified and directed .
S&F MS pipe 100mm dia, medium grade class B (thickness 4.5mm weight 12.10 Kg/mtr (±10%) , laid in trenches or floor or wall, jointed (Welded) tested and commisioned complete with ISI marked with all fittings like flanges, tees, elbows , bends junctions, reducers etc, clamps structural steel supports as required/ directed at site including cutting etc. includes two coat of synthetic red enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge.
S&F Tubes 20 mm bore, ‘medium grade’, ISI MARKED, galvanized with all fittings and fixed complete laid in trnches or walls and ceilings or laid in floors, complete all as specified.
Cutting existing water mains line of UT Chandigarh for inlet supply of Fire fighting tanks including all fittings like Tees, elbows, bends etc complete all as specified and directed.
Supply and fix in repair Gun-metal, globe or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 20 mm dia, in repairs, complete all as specified.MAKE: SANT,BIR, ZOLOTO, KIRLOSKAR
Black mild steel medium grade (thickness 3.25mm weight 2.44 Kg/mtr (±10%), 25 mm dia including fittings like flanges, tees, elbow, bends junction, reducer etc, clamps structural steel support as required/ directed at site including cutting welding etc and accessories required for fixing to wall or suspended to ceiling complete.
S&F Cast iron butterfly valve 100mm dia complete with epoxy coated disc, carbon steel shaft and lever actuator including falnges. ISI marked complete all as specified and directedby Engineer-in-Charge.
S&F Non return butterfly valve of size 100 mm dia bore complete all as specifed and directed by Engineer-in-Charge.
Air vessel of size 250mm diax 1 mtr height with pressure gauge air release valve and gate valve of 25mm dia (02 Nos) complete in all respect complete all as specified and directed by Engineer-in-Charge.
Supply and fix cast iron Air realese valve with two air outlets,50 mm dia bore and and fixing up in MS down comer
Pressure gauge with isolation cock suitable for working pressure of 0-14 kg/sqcm (liquid based high internsity) completeall as specified and directed by Engineer-in-Charge.
High pressure ball valve with fly nut complete suitable for 25 mm dia pipe complete all as specified and directed by Engineer-in-Charge.
Supply install and fixing fire brigade inlet connection 2 Way 100mm dia size complete all as specified and directed by Engineer-in-Charge.
Hose box of size 800mmx600mmx250mm made of MS sheet made of 18 gauge, double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red outside and brilliant white inside complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 63mm dia 30 mtr long RRL hose pipe confiming to IS 636 complete all as specified and directed
Hydrant landing valve Stainless Steel 63mm for fixing RRL hose pipe
Hose box made of MS sheet 2 mm thicknesssuitable for housing hose reel of 20 mm size for 30 mtr length complete with coupling branch pipe and nozzle , complete all as specified and directed by Engineer-in-Charge.
First aid hose reel (swinging type)including 30/36 meter long 20 mm intenal dia ruber lined hose reel tubing , 25 mm dia gun metal stop valve, shut off gun metal nozzle including fixing arrangement and ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply,Installation,testing and commissioning terrace pump of 450 LPM capacity at 30 mtrs head pressure not less than 3.5 kg/sq cm at top most hydrant suitable for fire fighting and conforming to IS-12469-1988 complete with totally enclosed drip proof squirrel cage indication motor with bronz impellers, pressure gause ,pressure gause,pressure switch complete to operate on 3 phase,415 volts,50 Hz complete including PCC fondation block and making connection with tail/tapper pieces to connect supply and delivery pipes,including pipes and also including fabricated MS common base plate of suitable size coupling guard air vent for casting pressure guages on delivery side and pipe etc. complete all as specified and directed by Engineer-in-Charge.
S&F pressure switch adjustable range 0 to 10 Kg/Sqcm universal type complete all as specified and directed by Engineer-in-Charge.
S&F flow switch 100 mm dia 0 to 10 Kg/cm2 complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with galvanized steel earth plate eleteode 600mmX600mmX6mm thick buried directly in ground Verticaly to a depath not less than 2.25mtr deep below normal ground level with top edge of earth plate at a depth of not less than 1.5mtr below normal ground level connected to galvanized iron strip 32mmX6mm by means of bolts, nuts, check nuts and washers made out of galvanized iron and GI earth strip protected by 40MM bore light grade GI Pipe as well as 20mm dia medium grade pipe 1.5mtr fixed with funnel and wire mesh as Specified and connected allas shown in electrical plate No 03 of SSR Part I including necessary earth work and excavation in any type of soil and PCC 1:2:4 type B-1 in chamber and 40mm thick 1:2:4 type B-1 cover slab with 6mm dia mield steel bars at 100mm center to center both way with 6mm dia MS hoks Complate all as Specified and as directed by Engineer in charge. NOTE :- The GI strip 32mmx6mm & 40mm bore light grade GI Pipe up to 7.5mtr deep to be included in the rate quoted by the Contractor
M&L for earthing with GI earth plate electrode 60cm x 60cm x 6.0 mm thick burried directly in ground vertically to depth of not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to GI earth wire of 4.0 mm dia by means of bolts, nuts, washers of GI and provision of earth lead, GI protection pipe with 15mm light grade galvanized including necessary earth work in any type of soil, PCC 1:3:6 type CI (using 20mm graded stone aggregate) earth chamber and 1:2:4 type B1 RCC cover fitted with50mm thick with 6mm dia MS bars complete all as shown in SSR Pt - 1 electrical plate No 3. Note : Quoted rate deemed to include the cost or excavation and earth work PCC Chamber, funnel cover etc.Complate all as Specified and as directed by Engineer in charge.
Supply and fix electronic meters 3 phase, temper proof LCD display with polycarbonate cover 415 V, 10-60 Amp, accuracy class-I 50 Hz, conforming to IS 13779, IP-54, with parameters to show date, time, current reading, load, PF, voltage and KWH
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm, 4 core all as specified and as directed
M&L for Sub main wiring/power wiring complete with four runs of 6.0 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surface wall/floors/concealed etc., with one run of PVC insulated, 6.0Sqmm FRLS copper conductor for earth continuity all as specified and as directed. NOTE :- Four runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts out door type, factory made free standing, floor mounting, dust and vermin proof cubical type, LT Panel fabricated from 3.15 mm thick CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), fully compartmentalized design with 4 Nos of copper bus bar of 100 Amps capacity each and supply and fixing the following :- Incoming (a) MCCB 25 Amps , 4 pole, ultimate breaking capacity 16 KA with fixed magnetic release for short circuit and adjustable thermal release for overload (Range 70% to 100% of nominal current) and under voltage release conforming to IEC-60947-2 and IS-13947-3 complete all as specified – 01 Nos Outgoing (a) MCCB 16 Amps , 4 pole, ultimate breaking capacity 16 KA with fixed magnetic release for short circuit and adjustable thermal release for overload (Range 70% to 100% of nominal current) and under voltage release conforming to IEC-60947-2 and IS-13947-3 complete all as specified – 02 Nos (b) Suitable size of star delta starter for booster/terrace pumps of cap 450 LPM at 30 mtr head - 02 Nos
Supply and installing ABC (Powder type) fire extinguisher HP mild steel cylinder , ISI marked , TAC approved fitted with pressure gauge internal tube , sequeeze lever type valve fully chrged with ABC powder (Mono ammonium phosphate) pressued of capacity 10 Kgs complete all as specified.
Supply and installing the fire point with 3mm thick CGI sheet stand includiing PCC work , marking the fire point in bold letters complete all as specified and directed
Supply and installing the fire bucket of capacity 10 ltrs as per IS duly ISI marked made out of mild steel sheet 2mm thick including painting with two coats of synthetic enamel paint (Red colour ) over a coat of red oxide primer complete all as specified
Supply and installing the fire beater as per IS duly ISI marked made out of mild steel wire mess including painting with two coats of synthetic enamel paint (red colour) over a coat of red oxide primer complete all as specified and directed
Supply and installing the fire hook as per IS duly ISI marked made out of mild steel wire mess including painting with two coats of synthetic enamel paint (red colour) over a coat of red oxide primer complete all as specified and directed
Supply and installing the crow bar as per IS duly ISI marked made out of mild steel wire mess including painting with two coats of synthetic enamel paint (red colour) over a coat of red oxide primer complete all as specified and directed
Supply and installing the shovel GS MK IIIas per IS duly ISI marked made out of mild steel wire mess including painting with two coats of synthetic enamel paint (red colour) over a coat of red oxide primer complete all as specified and directed
Supply and installing the shovel Axes pick 3 Kgs as per IS duly ISI marked made out of mild steel wire mess including painting with two coats of synthetic enamel paint (red colour) over a coat of red oxide primer complete all as specified and directed
Supply and install bottle type Fire extinguisher 2kg Capacity ABC type dry powder type complete alll as specified and directed .
Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, etc. and getting out complete, all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete, all as specified.
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
Sand cushioning with clean dry sand to cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cable complete all as specified. Note : For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I
Supply and laying of class B brick for under ground cable protection as directed by Engineer - in - Charge.
KUMAR AND COMPANY
R D Bansal
His Construction Company
UNITED ENGINEERING CORPORATION
shree balaji builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .