| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC 07 PRIYALOK COLONY PHASE 01 GMS ROAD DEHRADUN UTTARAKHAND | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.6 L+₹65,932.26 (3.00%)Rejected-Finance | L2 | Rejected-Finance HIGHEST BID | |
| 3 | L3₹22.9 L+₹99,021.26 (4.51%)Rejected-Finance Q 158 SHIVALIK NAGAR HARIDWAR PIN 249 403 | HARIDWAR | UTTARAKHAND | 249403 | L3 | Rejected-Finance HIGHEST BID | |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance Others-OFFLINE DOCUMENT NOT SUBMITTED |
| Sl No | Description | Qty | Unit | M/s A S Electrical & Power Controls L2 | KBM INFRABUILD PVT LTD L1 | Purohit Hydro Power Management L3 |
|---|---|---|---|---|---|---|
| 1.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B(ANCHOR,HAVELLS, ABB) | 203 | No | 1,097 ₹2,22,691 | 1,065 ₹2,16,195 Lowest | 1,113 ₹2,25,939 |
| 2.00 | 5/6 A switch | 16 | No | 96 ₹1,536 | 92.81 ₹1,484.96 Lowest | 97 ₹1,552 |
| 3.00 | 3 pin 5/6 A socket outlet. | 16 | No | 113 ₹1,808 | 109.93 ₹1,758.88 Lowest | 115 ₹1,840 |
| 4.00 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | 49 | No | 544 ₹26,656 | 528 ₹25,872 Lowest | 552 ₹27,048 |
| 5.00 | CREB S/F ceilling rose: eachSupplying and fixing 3 pin, 5 amp. ceilling rose on the existing junction box/wooden block including connection etc. as required | 71 | No | 81 ₹5,751 | 78.4 ₹5,566.4 Lowest | 82 ₹5,822 |
| 6.00 | BRHOLD S/F brass holder: Supplying and flxing brass batten/angle holder including connection etc. as required. | 45 | N0 | 122 ₹5,490 | 118 ₹5,310 Lowest | 123 ₹5,535 |
| 7.00 | Supply & fixing C series SP MCB S/F 5 amo 32 amp rating,240/415 Volt C curve,miniature circuit brecker suiteble for inductive load of existing DB complete with connections. | 100 | No | 238 ₹23,800 | 230.68 ₹23,068 Lowest | 241 ₹24,100 |
| 8.00 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. | 4 | No | 1,703 ₹6,812 | 1,653.53 ₹6,614.12 Lowest | 1,728 ₹6,912 |
| 9.00 | upplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings | 11 | NO | 627 ₹6,897 | 609 ₹6,699 Lowest | 636 ₹6,996 |
| 10.00 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. | 2 | NO | 481 ₹962 | 466.77 ₹933.54 Lowest | 488 ₹976 |
Tender Value
Refer Docs
EMD Value
₹75,000
Closing Date
18 Aug 2025, 10:00 amClosed
As Per Tender Notice
As Per Tender Notice
Electrification work of the pre-constructed building for the construction of Ganga Sanskriti Kendra Srinagar at Srinagar place in Khirsu development block of Pauri Garhwal district.
2025_RES_85695_1
RWD_EM_18_2025
Open Tender
Electrical Works
Item Rate
545 days
Srinagar garhwal
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
EE E/M RWD DEHRADUN
₹75,000
15 Sept 2025
30 Jul 2025
18 Aug 2025
30 Jul 2025
18 Aug 2025
30 Jul 2025
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B(ANCHOR,HAVELLS, ABB)
5/6 A switch
3 pin 5/6 A socket outlet.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
CREB S/F ceilling rose: eachSupplying and fixing 3 pin, 5 amp. ceilling rose on the existing junction box/wooden block including connection etc. as required
BRHOLD S/F brass holder: Supplying and flxing brass batten/angle holder including connection etc. as required.
Supply & fixing C series SP MCB S/F 5 amo 32 amp rating,240/415 Volt C curve,miniature circuit brecker suiteble for inductive load of existing DB complete with connections.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
upplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)
WGPVCSB Circuit/sub-man wiring in PVC conduit:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofPVC insulated copper conductor, single core cable in surface/ recessed PVC conduitas required. (2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
WGPVCSB Circuit/sub-man wiring in PVC conduit:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofPVC insulated copper conductor, single core cable in surface/ recessed PVC conduitas required. (2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
WGPVCSB Circuit/sub-man wiring in PVC conduit:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofPVC insulated copper conductor, single core cable in surface/ recessed PVC conduitas required. (2 x 4 sq. mm + 1 x 4 sq. mm earth wire
WGPVCSB Circuit/sub-man wiring in PVC conduit:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofPVC insulated copper conductor, single core cable in surface/ recessed PVC conduitas required. (4 x 16 sq. mm + 2 x 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (1 x 1.5 sq. mm
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.(ANCHOR,HAVELLS, ABB)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door(HAVELLS, L&T,LEGRAND,ABB,SEIMENS)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door(HAVELLS, L&T,LEGRAND,ABB,SEIMENS)
Supplying and fixing following rating, double pole, 240 V,isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A(HAVELLS, L&T,LEGRAND,ABB,SEIMENS)
Supply & fixing TP MCB isolator : S/F 63 amp rating ,415 V isolator on existing DB complete with connection.(HAVELLS, L&T,LEGRAND,ABB,SEIMENS)
Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT- AAA(HAVELLS,PHILIPS,OSRAM).
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 175 to 200 Watt. Confirming to IP 66 Protection complete in all respects CAT- AAA(HAVELLS,PHILIPS,OSRAM)
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.16 sq. mm 4 core.(HAVELLS,POLYCAB,FINOLEX,KEI)
S&F of 63 Amp. 415 V metal clad T.P.N. rewireable type switch fuse unit on angle iron bracket complete in all respect.
S & F sheet steel enclosure for S.P/ D.P. MCB with neutral link and earth terminal.CAT A
Supply and burring of Safe Earthing Electrode T-39 (Hot-Dip Galvanized), Length up to 3000mm, outer pipe 76mm inner Dia 38mm terminal Dia 12 mm ,outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board, cost of 25 X 3 GI. Strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.
Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect.
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.120 sq. mm 3-1/2 core
Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect.
M/s A S Electrical & Power Controls (BID ID -392799)
Purohit Hydro Power Management (BID ID -392764)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_101763.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .