Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-AOC | L1 | Accepted-AOC Work awarded as his bid was substantially responsive to the bidding document and is the lowest advantageous bidder | |
| 2 | L2₹42.6 L+₹6.7 L (18.8%)Rejected-AOC | L2 | Rejected-AOC Not the lowest bidder. KSEBL decided to award the work to the lowest qualified bidder. | |
| 3 | L3₹47.0 L+₹11.1 L (31.0%)Rejected-AOC | L3 | Rejected-AOC Not the lowest bidder. KSEBL decided to award the work to the lowest qualified bidder. | |
| 4 | Rejected-Technical | - | Rejected-Technical Not substantially responsive to the bidding document and has not met the qualification criteria as per clause 3(e) of section A ITB | |
| 5 | Rejected-Technical | - | Rejected-Technical Not substantially responsive to the bidding document and has not met the qualification criteria as per clause 3(a) and 3(e) of section A ITB |
Tender Value
₹45.1 L
EMD Value
₹50,000
Closing Date
22 Dec 2022, 12:00 pmClosed
The Chief Engineer, Dam Safety and DRIP
Dam Safety Organisation, Pallom, Kottayam, Kerala
Pressure Washing and Painting of the Dam body and Overhead Platform of Lower Periyar Dam
2022_KSEB_529283_1
CE(C-DS)/03/2022-23
Open Tender
Civil Works - Others
Item Rate
300 days
Pambla
Please refer tender documents
6 documents required · 6 mandatory
₹5,900
₹50,000
Yes
13 Apr 2023
24 Nov 2022
22 Dec 2022
24 Nov 2022
22 Dec 2022
24 Nov 2022
24 Nov 2022 - 8 Dec 2022
Amount
Pressure washing and Painting of the Dam body and Over head platform
Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing the surface by removing rust by applying approved rust remover as directed and plastering the surface of the wall complete after applying plaster bonding agent of approved make, including cost for putting all scaffoldings, hire charges etc., disposal of rubbish to the dumping ground within 50 meters lead using cement mortar 1:3 etc. complete as per the technical specifications and as directed by the Engineer in Charge.
Scrapping and cleaning the downstream face of dam and its appurtenance for removing dirt, dust, bird excretion, grease, oil, algae, fungus, monkey beats, vegetable growth etc. by pressure washing using winch and cradle platform including cost of materials and labour charges etc. complete as per the technical specifications and as directed by the Engineer in Charge.
Applying one coat of Water thinnable cement primer of approved brand and manufacture ( Brand as per Table 1.2 of Annexure 3) on wall surface etc. complete as per the technical specifications and as directed by the Engineer in Charge.
Wall painting with two coats of acrylic exterior emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture( Brand as per Table 1.2 of Annexure 3) including applying additional coats wherever required, to achieve even shade and colour as per the technical specifications and as directed by the Engineer in Charge.
Painting with aluminium paint two coat of approved brand and manufacture( Brand as per Table 1.2 of Annexure 3)on old work to give an even shade etc. complete as per the technical specifications and as directed by the Engineer in Charge.
Finishing with two coats of Epoxy paint ( Brand as per Table 1.2 of Annexure 3) at all locations prepared and applied as per manufacturer’s specifications including scrapping, cleaning, one coat Zinc Phosphate primer, preparation of surface where ever required on old steel work etc. completeas per the technical specifications and as directed by the Engineer in Charge.
Painting the upstream face of the Radial gate and lower vent of the Dam after the surface preparation through copper slag blasting process as per IS 1477 Part I-1971(the average surface roughness after copper blast should not exceed 40 microns) the copper blast surface should be cleaned from loose dust and debris through air blast with the help of blower, to the class B specification ie at least 95% of surface of steel should be cleared to base metal except some tightly bonded residue in the form of mill scale/rust only. Then apply two coats of zinc rich primer (containing not less than 85% of zinc on dry film) (Brand as per Table 1.2 of Annexure 3) to give a total dry film thickness of 70+5 microns within a time gap of 6 hrs. after surface preparation. Then apply two coats of solvent less coal tar epoxy paint (Brand as per Table 1.2 of Annexure 3) at an interval of 24 hrs (150 microns each) including the cost of epoxy paint, primer, copper slag, compressed air, labour etc. complete as per the guide lines of IS 14177-1994 (reaffirmed 2019)etc. complete as per the technical specifications and as directed by the Engineer in Charge.
Welding by electric plant on upper and lower vent gate hoisting structure of Lower Periyar Dam where ever necessary after cleaning the surface by sand paper/grinder etc. complete as per the technical specifications and as directed by the Engineer in Charge.
Aryacon Contractors and Engineers
M V Balakrishnan
K J JOSE
BRIJEESH K N
Bidder Name
Aryacon Contractors and Engineers
K J JOSE
M V Balakrishnan
Lenin
BRIJEESH K N
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_772388.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .