Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.2 LAccepted-AOC | ₹30.2 L Quoted ₹30.9 L | L1 | Accepted-AOC ACCEPTED BEING LOWEST QUOTED |
| 2 | L2₹33.3 L+₹2.4 L (7.89%)Rejected-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | ₹33.3 L+₹2.4 L (7.89%) | L2 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
| 3 | L3₹34.5 L+₹3.6 L (11.7%)Rejected-AOC | ₹34.5 L+₹3.6 L (11.7%) | L3 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
| 4 | L4₹34.5 L+₹3.7 L (11.9%)Rejected-AOC | ₹34.5 L+₹3.7 L (11.9%) | L4 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
| 5 | L5₹34.7 L+₹3.8 L (12.3%)Rejected-AOC | ₹34.7 L+₹3.8 L (12.3%) | L5 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
Tender Value
Refer Docs
EMD Value
₹62,000
Closing Date
15 Jul 2024, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE ARMY GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
COMPREHENSIVE MAINTENANCE AND REPAIR TO CERTAIN B/R WORKS INCLUDING PERIODICAL SERVICES AND INTERNAL E/M WORKS FOR ZONE 1 AT MIL STN GANDHINAGAR
2024_MES_660424_1
GE(A)/GNR/TOKEN/15 of 2024-25
Open Tender
Civil Works
Item Rate
180 days
MIL STN GANDHINAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY GANDHINAGAR
₹62,000
Yes
3 Sept 2024
18 Jun 2024
17 Jul 2024
18 Jun 2024
15 Jul 2024
2 Jul 2024
18 Jun 2024 - 29 Jun 2024
Amount
Taking down shutter of any description exceeding 1 Square Metre and not exceeding 2 Square Metre each complete all as specified and as directed.
Taking down chowkhat or frame (without taking off shutter from the frame) not exceeding 1.5 Square Metre each , removing from the site including cutting holes required for taking out existing hold fast etc. complete all as specified and as directed.
Taking down chowkhat or frame (without taking off shutter from the frame) exceeding 1.5 Square Metre and not exceeding 04 Square Metre each , removing from the site including cutting holes required for taking out existing hold fast etc. complete all as specified and as directed.
M&L Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.
S&F Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F 35mm thick IInd class hard wood panelled door shutter with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. the size of rail and stiles as per IS: 1003 (part-I), kiln seasoned and chemically pressure treated and fixed to chowkats complete.
S&F 35 mm thick IInd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats
M&L 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides compete all as specified and directed by Engr-in-Charge.
M&L for preparing of new untreated wooden surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint (of approved shade) over a coat of pink primer all as specified.
M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete & making good the floors/walls in PCC 1:2:4 type B-0 to match the existing floors/walls.
M&L painting to new or previously untreated steel surfaces of any description over 10cm in width or girth with two coats of synthetic enamel paint over a coat of zinc chromic primer including preparation of surfaces.
Supply and fixing stainless steel hinges 100mm long medium weight to pressed steel/angle iron frames by welding/screws all as specified.
S&F aluminium anodised barrel tower bolt 150mm size extruded section, ISI marked & fixed
S&F aluminium anodised barrel tower bolt 200mm size extruded section, ISI marked & fixed
S&F extruded aluminium alloy handles 150mm size fabricated type anodised. ISI marked.
S&F 300mm Aluminium alloy, anodised, sliding door bolt with hasp ,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified.
S&F anodized aluminium frame and other sections for doors, windows, ventilators, partitions, three track window including slinding roller, with one or more rebates including joining cleat for fixing etc. complete all as specified & as directed.
S&F anodized aluminium door shutters, aluminium section weighing 0.55 kg/m, including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodized aluminum snap beading screws etc. complete all as specified & as directed.
S&F door closer hydraulically regulated, designation No. 2, aluminium (Die cast) body, universal type (ISI marked) suitable for door shutters of 701 to 850mm in width aand weight between 36 to 60 Kg and fixed complete all as specified & as directed.
S&F anodized aluminium window and ventilator shutters, aluminium sections weighing 0.55 kg/m, including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as three track window/as per required bases complete all as specified & as directed.
Supply only 4.8mm thick Sheet glass, ordinary quality, in squares n exc 0.5 sq. m each pane all as specified and directed by Engr-in-Charge
Supply only 4.8mm thick Sheet glass, ordinary quality, in squares exc 0.5 sq. m each pane all as specified and directed by Engr-in-Charge
Supply only 5mm thick Froasted glass in squares n exc 0.5 sq. m each pane all as specified and directed by Engr-in-Charge
Supply only 5mm thick Tinted Coloured glass fixed to metal frame complete all as specified and directed.
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples & scrwed complete all as specified and directed
S&F in repair anodized aluminium grill of approved pattern and fixed to the existing window/ventilator frame with CP brass/stainless steel scrwed @ 200mm center to center, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per requirement & directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified.
M&L for 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces complete all as specified.
S&F in repair Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples & scrwed complete all as specified and directed
S&F in repairs powder coated stainless steel drapery rod of 25 mm inner dia (in lengths as directed) of approved colour with & including decorative bowel at both ends and pair of powder coated mild steel brackets fixed at both ends with PVC rawl plug & steel screws on walls/beam, including PVC curtain rings of matching colour @ 10cm C/C all as specified & as directed.
S&F in repairs door closer hydraulically regulated, designation No. 2, aluminium (Die cast) body, universal type (ISI marked) suitable for door shutters of 701 to 850mm in width aand weight between 36 to 60 Kg and fixed complete all as specified & as directed.
S&F in repair for double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty, fixed in repairs, with & including replacement of floor tiles if any broken during repair work and making good disturbed surfaces matching to the existing surfaces complete all as directed
Supply and fixing in repairs brass mortice lock, vertical type, size 100mm, 4 Levers with escutcheon plates & two keys fixed in aluminium frame complete all as specified.
Taking down carefully anodized aluminium/NCL/Bombay Slinding doors/windows/ventilators frame including glazed shutters & builder’s hardware complete of any size and any description and refixing in the same opening after carrying out necessary repair & replacement of unserviceable components / hardware to make it fully functional complete all as specified & as directed. Notes :- (i) Quoted rate shall deemed to include supply & fixing of new joining cleats, aluminium beadings, glazing clips, rubbers packing,slinding rollers, stays including cutting of old styles etc & adjusting the same appropriately as directed. (ii) New aluminium sections for frame/shutters, builder’s hardware such as handles, hinges, door closure, floor door spring shall be measured & paid for separately. (iii) New Glazing shall be measured and paid separately but payment supply only items (iv) Loose corner joints of frame & shutters shall be tightened by providing suitable cleats made out of aluminium angle of appropriate size fixed with nut & bolts to make the joints at 90º.
Repairs to Steel window/ventilator any type & any size by taking down Shutter, replacing defective hinge,handle & locking arrangement including necessary welding (if any) and resecuring fixed to frame complete all as specified and directed
Resecuring or easing & adjusting, without taking down shutter of any description exc 1 sqm and not exc 2 sqm each all as directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings.
M&L Pre- painted galvatume aluminum zinc coating GI based Semi-corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engr-in-Charge.
Demolition Mud in roofs, any thicknes, including plastering , existing tretement and cleaning (whether full thickness removed or only or part there of) etc in all respect and preparing it for further treatment and taking out and disposal of debris & rubbish to a distance exc 1 Km but not exc 1.5 Km complete all as specified & directed by Engr-in-Charge.
M&L screed laid 15mm thick in CM 1:4 as in roof over green concrete surface finished even and smooth using Lequid WPC complete all as specified. Note :-Lequid WPC will be measured and paid seperately)
M&L for providing cement concrete in type B0 1:2:4 (using 12.5 mm graded crushed stone aggregate) as in roof padding, laid to (consolidated thickness 65mm or less) as leveling course, laid and compacted in min slope 1:30 over roof complete all as specified& directed by Engr-in-Charge.
M&L for roof treatment using APP based polymeric membrane minimum weighing not less than 3kg/sqm black finish reinforced with non woven polyster matt with thermo finish (wt. not less than 150 gms/sqm) laid over compatible bitumen primer @0 .30 liters per sqm and bitumen 85/25 @ 1.20 Kg per Sqm with help of torching with a proplyne or a butane gas using torch with minimum overlap of 75mm at side and 100mm at ends and sealing including applying a coat of bitumen primer & bitumen 85/25 applied hot all as per manufacturer instructuions. For parapet in a groove (No separate payment will be made and measurement will be done for horizontal surfaces) including applying a coat of heat repallant bitumen aluminium paint @ 0 .1 liter per Sqm on topof treated surface of roof complete all as specified and directed.
Demolition of brick/stone masonry built in cement/lime mortar of any mix including all quoins pillar ashlars masonry and removal complete all as specified& directed.
M & L brick work sub class 'B' bricks (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L brick work sub class 'B' bricks , (OLD SIZE BRICKS) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and directed.
M&L for PCC 1:3:6 type C1 (using 20 mm gradded stone agg )as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, drain channels, copings,parapets copings, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed.
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed.
M&L rendering 10mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified.
M&L for rendering 15mm thick in CM 1:4 on stone wall surfaces or other than fair faces of brick work & surfaces finished even and smooth without using extra cement with water proof compound ( water proof compound paid seperatly) all as specified.
M&L rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified.
Supply only integral liquid water proofing compound (ISI marked). Make : Pidilite (Dr. Fixit Pidiproof LW) or equivalent of Fosroc / Sika / STP
M & L for internal/external plaster/unplastered newly/old surfaces on walls/ceilings and preparation of surfaces of walls/ceilings and plaster of paris putty of 1mm thick complete all as specified and directed by Engr-in -Charge.
M&L for preparation of new plastered surfaces of walls and applying two coats of Oil bound distemper complete all as specified & directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified.
Material and labour for preparation of newly plastered surface of walls & applying two coats of cement base paint over a coat of primer complete all as specified.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed
Material and labour for preparation of newly plastered/unplastered surfaces of ceilings & applying three coats of white wash complete all as specified.
M&L for preparation of newly plastered/unplastered surfaces of ceilings & applying two coats of oil bound distemper (OBD) complete all as specified..
M&L for preparation of old surfaces of walls and applying one coat of oil emulsion distemper (OBD) of approved shade/tint all as specified & as directed.
M&L for preparation of old decorated surfaces of walls and applying two coat of oil emulsion distemper (OBD) of approved shade/tint all as specified & as directed.
M&L for preparation of old decorated plastered/unplastered surfaces of ceilings & applying one coats of oil bound distemper (OBD) complete all as specified..
M&L for preparation of old decorated surfaces of walls, plastered including cornices, pilasters etc and applying one coats of white wash complete all as specified.
M&L for preparation of old decorated surfaces of walls, plastered including cornices, pilasters etc and applying two coats of white wash complete all as specified.
M&L for preparation of old decorated plastered/unplastered surfaces of ceilings & applying one coats of white wash complete all as specified..
M&L for preparation of old decorated plastered surfaces of walls and applying one coat of cement base paint of approved shade/tint complete all as specified & as directed.
M & L for complete removal of existing treatment on walls/ceilings and preparation of surfaces of walls/ceilings and applying plaster of paris putty of 1mm thick complete all as specified and directed by Engr-in -Charge.
M&L preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified.
M&L preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified.
M&L for preparation of old decorated surfaces of walls, plastered including cornices, pilasters etc and applying one coats of weather proof exterior emulsion paint complete all as specified.
Dismentling floor , hearth or wall tiling incl cement mortar bedding (but ot backing) , removing serviceable tiles to store and rubbish off the premises
M&L for 16-18mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, windowcills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick screed bed CM 1:6 complete all as specified& directed by Engr-in-Charge.
M&L for vitrified ceramic tiles 8-9mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile not exceeding 0.36 sqm, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
M&L Glazed ceramic coloured tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles and over 10 mm thick rendring in cm 1:4 complete all as specified& directed by Engr-in-Charge.
M&L kota stone slab 10-15 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over rendering back of tile 10 mm CM 1:4 complete all as specified& directed by Engr-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level.) & removing unserviceable materials in low laying area, complete, all as directed by Engr-in-Charge.
M&L for 25 thick cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in levelling coarse for tiles.
M&L for 75 mm thick PCC 1:4:8 type D -2 using 40 mm graded stone aggregate as in sub base complete all as specified& directed by Engr-in-Charge.
M&L for Providing and laying prepolished cement concrete Chequered tiles 30cmx30cmx25mm thick, with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape heavy duty , set,jointed and pointed in neat cement slurry in floors over screed bed 15mm thick 1:6 cement mortar complete all as specified& directed by Engr-in-Charge.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand compelete all as specified and directed
M&L for vitrified ceramic tiles 8-9mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and directed.
Material and labour coloured non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for 10mm thick heavy duty, exterior grade parking tiles ( durastone of somany/Endura of jhonson or equivalent as approved by GE) of area of each tile exceeding 0.08 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L machine cut kota stone slab flooring 20-25mm thick and area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over screed bed 15mm thick 1:6 cement mortar complete all as specified& directed by Engr-in-Charge.
Dismantling of cement concrete (un-reinforced) kerb stone and the like of any description of and in any position not otherwise specially provided for complete all as specified and directed.
M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed.
Dismantling Wall and ceiling boards icluding framework (PVC penelling incl fillet, fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specifiedand directed
M&L for non asbestos fibre reinforced designer cement board false ceiling made out of E-board classic of size 600 x 600 x 4 mm thick, GI frame consisting of main Tee of size 38.50 x 24.00 mm and cross Tee of size 28.50 x 24.00 mm thick made out of PGI sheet 0.30 mm thick doubled at web and single at flange, flange covered with powder coated sheet 0.25 mm thick and angle 24.00 x 24.00 x0.4 mm thick powder coated suspended with GI wire 3 mm dia and up to 2 Mtrs long complete including plugging fixing of angle to brick walls with steel rawl plugs @ 450 mm c/c all as per manufactures instructions etc complete all as specified and as directed
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) of any thickness complete all as specified and directed.
M&L for M&L for non asbestos fibre reinforced designer cement board false ceiling made out of E-board classic of size 600 x 600 x 4 mm thick, (as approved by GE) fixed with existing frame work fixing the board to frame complete all as per manufacurers instructions all as directed and specified.
S&F in repairs stainless steel Kitchen plate rack of overall minimum size 750mm x 750mm and 230mm deep, with partitions for small/large plates etc made out of stainless steel 24 Gauge, fixed with rawl plug and CP steel screws all as directed. Note : Weight of rack shall not be less than 4.00 Kg.
S&F in repairs stainless steel Kitchen plate rack of overall minimum size 900mm x 900mm and 230mm deep, with partitions for small/large plates etc made out of stainless steel 24 Gauge, fixed with rawl plug and CP steel screws all as directed. Note : Weight of rack shall not be less than 6.00 Kg.
Taking up or down 15mm steel tubing and connections, including cleaning for re-fixing or removal to store
Taking up or down 20mm steel tubing and connections, including cleaning for re-fixing or removal to store
S&F steel tubing medium grade 15mm bore with all fittings fixed complete to wall and or laid in floor all as specified.
S&F 20mm GI tubing Medium grade fix to wall/floor fixed complete all as specified.
S&F in repairs 15/20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed , minimum weight - 210 gms of including taking down existing ball valves any type all as directed by Engr-in-Charge.
S&F in repair Vitreous china wash down water closet pan “Pedestal Pattern” white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminium anodized hinging device including flush pipe and joints etc and connection to drain, flushing, pipe, anti-syphonage pipe and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type (B-0) as in repairs, complete all as specified and directed.
S&F in repair Vitreous China squatting pan “Orissa ” pattern size 580 X 440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe ) fixed in repairs, including connecting to trap and to flushing pipe, etc including making good to dismantled portion of floors with PCC 1:2:4 type B-0 complete all as specified and directed.
S& F in repairs Vitreous China Wash Hand Basin, white, flat back, size 550x 400 mm including PVC waste pipe 32 mm bore and CP waste coupling, chain and plug and porcelain stopper including mild steel brackets, made out of 25 x 25 x 3 mm thick angle iron of required lenght, fixed to wall with PCC type B-0), fixed in repairs, including cutting for a pinning in a brackets complete all as specified and directed.
S&F 32mm dia waste fitting (waste coupling) brass chromium plated for glazed ware sink, basin etc with long screwed shanks and fly nuts flange complete for the following sizes all as directed by Engr-in-charge
S&F in repair 32mm dia waste fitting (waste coupling) brass chromium plated for glazed ware sink, basin etc with long screwed shanks and fly nuts flange complete for the following sizes all as directed by Engr-in-charge :-
S&F in repairs Jet spray chromium plated brass for EWC with & including PVC connection1mtr long suitable for 15 mm bore GI pipe with PTMT nut & nipple complete.
Supplying and fixing in repair valve less symphonic action type , PVC low level flushing cistern 10 litres capacity, white, with inlet, ball valve, flot and handle including PVC flush pipe 32 mm bore (Make – DIPLAST) and mild steel brackets made out of 25 by 25 by 3 mm thick angle iron of required length fixed to wall with PCC type B-0 (1:2:4), complete all as specified including taking down HL/LL PVC or Viterous China flushing cistern and making good the disturbed surfaces in cement mortar 1:3 complete all as specified and directed.
S&F in repairs PVC connection of 15mm bore with 2 Nos. PTMT nuts, 45cm long fixed with one end to pillar tap & the other end to stop cock or iron pipe all as directed by Engineer-in-charge.
Supply and fixing including fixed in repairs Tubular towel rail, 20 mm dia, D type, 60 cm long between flanges, brass chromium plated, fixed in repairs, complete all as specified and directed.
S&F in repair Brass chromium plated towel rack 24 " long, fixed in position with steel screws complete all as specified.
S&F in repair Plastic water closet seat cover White, closed pattern with flat bottom, and mild steel chromium plated or aluminium anodized hinging device, complete all as specified and directed.
S&F in repairs Pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks & fly nuts, screwed for iron pipes of 15mm bore all as specified
S&F Pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks & fly nuts, screwed for iron pipes of 15mm bore all as specified
S&F in repairs Pillar tap, of PTMT any colour, high pressure, screwed for iron pipes of 15mm bore (Min wt 110 gms) all as specified.
S&F in repairs fancy type center hole basin mixer without popup waste system but including plain waste 32 mm size with aerator complete cast copper alloy, chromium plated, scrwed downhigh pressure, with long scrwed shanks & fly nuts scrwed for iron pipes of 15 mm bore complete all as specified & as directed.
S&F in repairs brass chromium plated WHB mixer for mixing hot & cold water screwed down for iron pipe of 15mm bore all as specified and as directed.
S&F in repairs brass chromium plated shower rose 125mmx125mm size with swivel joint type including fixing to steel pipe of 15mm bore or union complete all as specified.
S&F in repair shower rose, PVC 100mm x 100mm size with suitable for 15mm bore pipe with swiveling joints complete all as specified
S&F in repair bib tap cast copper alloy with crutch or butter fly handle 15mm bore chromium plated fixed
S&F in repair bib tap standard of PTMT any colour 15mm bore high pressurescrewed for iron pipe fixed in repair(Min. wt 90 gms) complete.
S&F in repair Stop valves, 15mm bore cast copper alloy,screwed down,high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
S&F in repair Angle Stop valves, cast copper alloy chromium plated screwed down, high pressure, with crutch or butter fly handle screwed both ends for iron pipe or for unions suitable for 15 mm bore tubes, complete all as specified
S&F in repair 20mm bore Stop valves, cast copper alloy screwed down high presure, screwed both ends for iron pipe or for unions fixed
S&F in repair vitreous bowl urinal flat back,size of 465x355x265mm white (minimum), including waste coupling and waste pipe with grating, Spreader with connection and union for discharge pipe all as specified .
S&F Stop valve of 15 mm dia PTMT any colour high pressure screwed for iron pipe and fixed in repair.
S&F in repair chromium plated Brass health faucet for EWC with including PVC Connection 1m long suitable for 15mm bore with all connected fittings.as approved by the GE.
S&F in repairs wall mixer chromium plated (3 in -1) with arrangement for both telephonic shower and overhead shower with 220 mm max long bend pipe with hand shower of size 100 x 55 mm with 130 mm long arm & 1.2 m house pipe complete all as specified & directed.
S&F in repairs wall mixer chromium plated (2 in -1) with arrangement for overhead shower with 220 mm max long bend pipe including over head shower etc. complete all as specified & directed byEngr-in-Charge.
S&F in repairs vitreous china counter top/down basin size 450 x 525 x 195 mm shape oval of Jaquar or equivalent of PARRYWARE / MARC / KINGSTON / SOMANY / ESS ESS / SIECO / KOHLER / HINDWARE / PRAYAG / PARKO including 32 mm CP waste coupling & PVC flexible waste pipe of 90 cm long complete all as specified & directed.
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern EWC), coloured, floor/wall mounted coupled closet, including connection to drain (or outgoing pipe), anti-sypohonage pipe etc, with & including WC seat cover coloured closed pattern with flat bottom and cover, CP jet nozzle, vitreous china symphonic action type twin flush flushing cistern of 10 litre capacity with lid, necessary fittings complete all as specified & as directed. Make : “Cardiff Range” of Parryware equivalent of M/S Johnson, H & R India Ltd / M/S Hindustan sanitary ware and Industries Ltd / CERA, Madhusudan Ceramic as approved by GE.
Supply and fixing in repair 500 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I
Supply and fixing in repair 1000 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I
Disconnecting & dewatering of PVC/RCC overhead taks, scrubbing the inner surfaces, cleaning & removing all scales, dirt etc from mouth of circulating pipes, washing the tanks with fresh water and disinfecting the same by flushing with liquid chlorine or any other equivalent chemical, reconnecting & refixing in position after cleaning for tank capacity not exc 500 ltrs each including marking the date of cleaning with white paint and stencil all as required & directed. Note: Cleaning shall be done through wash out pipe by marking suitable arrangement to the outlet pipe such as cutting of the pipe providing short piece of pipe fitting and union coupling etc where the wash out pipe are not existing. The dirt etc shall not be allowed to enter the water supply system.
All as per serial item No 131 here-in-above but exc 500 ltr and not exc 1000 ltrs capacity.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/laid in trenches including removing the old pipes and making good the disturbed surface as per existing complete all as specified & directed.
Ditto as above items s.no. 133 but floors
S&F in repair 80 mm bore PVC (SWR) single junction (single 'T' ) equal or unequal provided with access door complete all as specified.
Supply and fixing in repair 80mm bore PVC (SWR) bends any radius complete all as specified.
Supply and fixing PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls/spout pipes including removing the old pipes and making good the disturbed surface as per existing complete all as specified & directed.
Ditto as above items s.no.137 but floors
Supply and fixing in repair 110 mm bore PVC (SWR) bends any radius complete all as specified.
Supply and fixing in repair 110 mm bore PVC (SWR) vent cowl complete all as specified.
S&F in repair 110 mm bore PVC (SWR) single junction (single 'T' ) equal or unequal provided with access door complete all as specified.
S&F in repair 18mm hick, PVC sheet/board one side prelaminated of approved texture as in kitchen cabinet/cupboard ( with shelves and partions) including necessary fittings & fixture like auto closing concealed hinges, 75mm long fancy SS handle, magnet catch etc as per manufacturers instructions. Make ; Rajshree/Sintex
S&F in repair 15x20x4 Inch stainless steel kitchen basket with stainless steel wire perforated plate fabricated and stainless steel telescopic drawer channel with wall bearing soundless complete
S&F in repair 16mm thick mineral fibre accoustic tile RH-99 Classic tile with suspension system complete
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc.
Taking down carefully copper/aluminum point wiring (light, fan,socket or power) complete,including fixture and fitting such as as switches, ceiling roses, pendants, regulators, sockets,etc excluing light fittings etc,removing materials to store for keeping in safe custudy or for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surface of walls, ceiling, floor etc to match with the existing surface.
Taking down carefully fittings such as switches, ceiling roses, pendants, regulators sockets removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc.:-
(a) 5 Amp Switches
(b) 15 Amp Switches
(c) 5/15 A SSC
(d) 5 A SSC
(e) Fan Regulator
(f) Tube Light any Type and Size
(g) Fan Any Type and Size
(h) Batten/Angular Holder
(j) Bulk Head Fittings/ Bldg Security Light Fittings
(k) 15 A Socket
(l) 5 A Socket
(m) Geyser Any Capacity size and shape.
(n) Exhaust fan any sweep
(o) 2 X 2 Ceiling light
Refixing of wiring Retrived from ser Item no.146
Refixing of fitting and fixtures after proper cleaning with cleaning solution CFC Free Retrived from serial item no. 148 :-
(a) 5 Amp Switches
(b) 15 Amp Switches
(c) 5/15 Amp SSC
(d) 5 Amp SSC
(e) Fan Regulator
(f) Tube Light any Type and Size
(g) Fan Any Type and Size
(h) Batten/Angular Holder
(j) Bulk Head Fittings/ bldg Security Light/ceiling light Fittings
(k) 15 A Socket
(l) 5 A Socket
(m) Geyser Any Capacity size and shape.
(n) Exhaust fan any sweep
(o) 2 X 2 Ceiling light
Maintenance /servicing and Testing of Ceiling Fan of any sweep by engaging labour and using Spl T&P, these factors should be deemed to be included in unit quoted rate & replacement of unserviceable parts are as under :-
(a)Capacitior 2.5 MFD
(b) Bearing any size and type to suit existing Bearing of Make NBC/Tata/SKF
(c) Rewinding of Ceiling Fan Complete with super enamelled copper winding wire
(d) Proper Greasing oiling and complete servicing of Ceiling Fan
(e) BLDC Ceilling Fan controler driver
(f) BLDC Ceilling Fan PCB.
(g) BLDC Ceiling fan magnet ring rotor
(h) Stator & Rotor Assembly complete
Maintenance /servicing and Testing of Exhaust fan any Sweep of any sweep by engaging labour and using Spl T&P, these factors should be deemed to be included in unit quoted rate & replacement of unserviceable parts are as under :-
(a) Capacitor 3 MFD
(b) Capacitor 3.- 5 MFD
(c) Bearing any size and type to suit existing Bearing of Make NBC/Tata/SKF
(d) Bearing any size and type to suit existing Bearing
(e) Rewinding of Exhaust Fan Complete with super enamelled copper winding wire
Maintenance /servicing and Testing of Desert Cooler of any sweep by engaging labour and using Spl T&P, these factors should be deemed to be included in unit quoted rate & replacement of unserviceable parts are as under :-
(a) Capacitor 3 MFD
(b) Capacitor 3.-5 MFD
(c) Bearing any size and type to suit existing Bearing of Make NBC/Tata/SKF
(d) Rewinding of Cooler Fan Complete with super enamelled copper winding wire
(f) Motor of capacity 65 - 120 Watt suitable for desert cooler all as specified and directed
(e) Proper Greasing oiling and complete servicing of Desert Cooler
Maintenance /servicing of Refrigerator 165- 200 ltr Capacity by engaging labour and using Spl T&P, these factors should be deemed to be included in unit quoted rate & replacement of unserviceable parts are as under :-
(a) Capacitor Starting / Running as per Existing Capacity.
(b) Refrigerant Gas Charging 134a
(c) Replacement of Compressor
(d) Rewinding of Cooling Fan Complete with super nemelled copper winding wire
(e) Proper Greasing oiling and complete servicing of Swithes Lights and Replacement of Minor Parts
(f) Replacement of PCB Set Power and Control Card complete all as specified
Maintenance /servicing of Refrigerator 200- 350 ltr Capacity by engaging labour and using Spl T&P, these factors should be deemed to be included in unit quoted rate & replacement of unserviceable parts are as under :-
(a) Capacitor Starting / Running as per Existing Capacity.
(b) Refrigerant Gas Charging 134a
(c) Replacement of Compressor
(d) Rewinding of Cooling Fan Complete with super enamelled copper winding wire
(e) Proper Greasing oiling and complete servicing of Swithes Lights and Replacement of Minor Parts
(f) Replacement of PCB Set Power and Control Card complete all as specified
Maintenance /servicing of Deep freezer 200- 350 ltr Capacity by engaging labour and using Spl T&P, these factors should be deemed to be included in unit quoted rate & replacement of unserviceable parts are as under :-
(a) Capacitor Starting / Running as per Existing Capacity.
(b) Refrigerant Gas Charging 134a
(c) Replacement of Compressor
(d) Rewinding of Cooling Fan Complete with super enamelled copper winding wire
(e) Proper Greasing oiling and complete servicing of Switches Lights and Replacement of Minor Parts
(f) Replacement of PCB Set Power and Control Card complete all as specified
Maintenance /servicing and Testing of AC 1.5/2 ton capacity of any make for minimum every month and record shall be maintained n register with sign of user Name , Rank and A/ No with unit pertains during the contract period by replacemet of Unsv parts are as under :-
(a) sealed unit compressor
(b) M&L for refrigent charging with R-22/R-32 making necessary copper tubing connection for refrigent line,soldering ,brassing of leakage point complete
(c) electronic PCB split/window AC as per sample
(d) starting relay with overload protection
(e) thermostate as per existing sample
(f) Running capacitior,230 volt sp,36/45/50 mfd complete
(g) starting capacitior,230 volts,80-100 mfd suitable for AC
(h) air filter as per sample
(i) S&F blower motor outdoor
(j) S&F blower motor indoor
(k) Refrigent charging R-410a
Maintenance /servicing of water cooler of capacity 40/80 ltr by engaging labour and using Spl T&P, these factors should be deemed to be included in unit quoted rate & replacement of unserviceable parts are as under :-
(a) sealed unit compressor
(b) M&L for refrigent charging with R-134(a)
(c) starting relay of water cooler of any type
(d) overload protection for water cooler
(e) S&F runing capacitor 10/15/20 mfd
(f) S&F starting capacitior 40/60/100 mfd
(g) thermostate as per existing sample
(h) S&F waste water pvc pipe with clamp
M&L for wiring with and including multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including, rigid non metallic, PVC concealed conduit of 25 mm OD and including cutting chases for conduits and sinkings for boxes, its accessories & including with multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating with provision sunken concealed terminal boxes complete all as specified and directed for One light/fan point controlled by one switch.
(a) One light/fan point controlled by one switch
(b) One 5 Amps socket on Independent board.
(c) One 5 Amps socket on the same board.
M&L for wiring with and including multi stranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including, rigid non metallic, PVC concealed conduit of 25 mm OD and including cutting chases for conduits and sinkings for boxes, its accessories & including with multi stranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating with provision of sunken concealed terminal boxes complete all as specified and directed for the following :-
S&F in repair socket outlet multipurpose, 3 pin, 15 Amps flush type complete all as specified and directed.
S&F in repair switch piano flush button single pole, one way 15 Amps complete all as specified and directed.
S&F in repair switch piano, flush button single pole, one way 5 Amps complete all as specified and directed.
S&F in repair Ceiling rose, PVC/poly carbonate,isolated body three terminals,complete all as specified and directed.
S &F fix in repair Distribution Board SPN 8 way, 240 volts, factory made powder coated, double door with neutral and earth link, suitable for fixing MCB,s complete including connecting all as specified and directed.
S & F in repair MCB’s single pole, 6 to 32 Amps 240 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
S & F in repair MCB’s SPN 32 Amps 240 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fixing in repair LED batten lights fitting 1x 20W, ultra slim square/round profile Led lighting fixture with polycarbonate,environmental friendly,energy efficient suitable size from ceiling rose complete.
S&F in repair lamp holder, insulated body with back plate for batten fittings complete all as specified and directed .
S&F in repair socket outlet multipurpose, 3 pin, 5 & 15 Amps flush type complete all as specified and directed.
M&L maintenance /servicing and Testing of Geyser any Capacity By Replacement of Unsv parts are as under:-
(a) Heating Element 1500 watt .
(b) Heating Element 2000 watt
(c) Indicator red and Green
(d) Inner Tank SS
(e) Syphon Assembly SS
(f) Thermostate
(g) Glass Wool
(h) Complete Servicing of Geyser
Maintenance /servicing and Testing of 2 x 2 ceiling light by replacement of Unsv parts for 36 Watt driver complete all as specified and directed
M & L in replacement sub-main wiring with 2 single core 6 Sqmm PVC insulated, unsheathed, 1100Volts grade, copper multi stranded conductor drawn in PVC conduit ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 6.0 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire drawn through and connected to main switch/ DB and testing on completion. Note: (i). 2 run of main conductor and one run of earth conductor shall be measured as one length.
Maintenance /servicing and Testing of Wall Fan 400/600 mm Sweep by engaging labour and using Spl T&P, these factors should be deemed to be included in unit quoted rate & replacement of unserviceable parts are as under :-
(a) Complete motor
(b) Rewinding of Wall Fan Complete with super enamelled copper winding wire
(c) Proper Greasing oiling and complete servicing and Replacement of Minor Parts
ALBA AC AND REF SERVICES
SNEH TRADERS
Shree Builders
Ramdev and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .