Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 11 492 IRIMPANAM TRIPUNITHURA ERNAKULAM KERALA 682309 | ERNAKULAM | KERALA | 682309 | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical Have more than three works under execution |
| 3 | Rejected-Technical | Rejected-Technical Have three works under execution |
Tender Value
₹11.5 L
EMD Value
₹24,000
Closing Date
8 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Director
NIT Calicut, NIT Calicut Campus PO, Kerala, 673601
Replacing the existing damaged incomer, main switch boards, distribution boards and old energy meters at Apt A
2024_NITC_791086_1
Engg/EMU/AE/171/Apt A Cable Change
Open Tender
Electrical Works
Item Rate
60 days
NIT Calicut, NIT Calicut Campus PO, 673601
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹24,000
Yes
26 Feb 2024
18 Jan 2024
12 Feb 2024
18 Jan 2024
8 Feb 2024
18 Jan 2024
Amount
Supplying of one number 3.5C x 95 Sq.mm size Aluminium conductor XLPE insulated PVC sheathed power cable of 1.1 kV grade etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5C x 95 sq.mm in the existing DWC HDPE pipe as required.
Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
Supply and laying of 3 inch 80 NB GI pipe (medium class B) on ground with all accessories like socket, bend, couplers with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., and making good the damages of road with concrete mixture of 1 : 2 : 4 including watering & ramming etc. as required.
SITC of a cubical type floor mounting switch board made from 75x40x6 size 'C' channel base frame and 2 mm thick MS sheet, powder coated in suitable colour over a coat of primer, copper bus bars of size 25x5 mm sleeved with heat shrink sleeves, bakelite fuse units with 2 A HRC fuses, coloured phase indication lamps(LED) and switches, separate cable entry/ wire way boxes for the switches with detachable front cover, providing rubber beedings, earthing all metal parts and switches with 25x3 mm copper strips, giving rigid connections from 100A MCCB to busbar with 25x5 mm tinned copper busbar and busbar to sub switches with 4 SWG tinned copper, sleeved with heat shrink sleeves and marking the identification of switches with white paint, fixing danger notice board etc as required. The details of the switches & meters are mentioned below. Switches Incomers :-100 amps 25 kA 4 pole MCCB with varying depth rotary handle. Outgoing :-63 amps 16 kA 4 pole MCCB with varying depth rotary handle - 1 No & 40 amps 16 kA 4 pole MCCB with varying depth rotary handle - 5 Nos. The unit as a whole should be dust and vermin proof. The minimum clearance from the bottom switch handle to the ground level should be 60 cm.( The drawing of the panel board is attached with the estimate)
Supplying and fixing 4 way ( 8+12 ), horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator)
Supplying and fixing 6 way ( 8+18 ), horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolator)
Supplying and fixing 8 way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 6-32 A rating, 240/415 V, 'C' curve miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 25A rating, 415 V, 'C' curve miniature circuit breaker suitable for inductive load of Double pole in the existing metal enclosure, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 25A, double pole, (Single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 32 A rating, 240/415 V, 'C' curve miniature circuit breaker suitable for inductive load of Triple pole and neutal in the existing MCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40 A rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 A rating, 240/415 V, 'C' curve miniature circuit breaker suitable for inductive load of Triple pole and neutal in the existing MCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 A rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and drawing 3 numbers 6 sq mm FRLS PVC insulated copper conductor single core cable (Red, Black & Green) in existing surface / recessed PVC conduit as required.
Supply Installation Testing and Commissioning of 1 phase 240V (L-N) 10 - 60A electronic type energy meter with LCD display, class 1.0s base mounting type including connections etc. as required.
Supply and making end termination with brass compression gland and aluminium legs for 3.5C x 25 sq.mm (28 mm) size of XLPE insulated PVC sheathed armoured aluminium cable as required.spacing not exeed 50 cm etc. as required.
Supply and making end termination with brass compression gland and aluminium legs for 3.5C x 95 sq.mm (45 mm) size of XLPE insulated PVC sheathed armoured aluminium cable as required.spacing not exeed 50 cm etc. as required.
Charges for removing the old wall mounted panel board with frame, making good the damages of the wall/ floor including painting, dismantle the SFU's and other accessories without any damage and conveyance of the material to the godown etc, as required.
Charges for removing the old wall mounted DB's, making good the damages of the wall/ floor including painting, dismantle the SFU's and other accessories without any damage and conveyance of the material to the godown etc, as required.
Supply and providing DCP type fire extinguisher (5kg) with BC powder and CO2 cartridge and hose, clamps etc.with ISI mark.
Supply and providing one number of 2 m x 1m 12mm size, electrically graded, rubber mat (IS:5424 / 1969) in front of the main switch board.
Supply and providing ISI plate earthing as per IS 3043, with G.I earth plate 600 mm x 600 mm x 6 mm thick including all accessories, providing masonry enclosure with CI cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/coke and salt) as required.
Supplying and laying 25 mm x 5 mm GI strip, from the bottom of the earth plate to the test joint, including connection / terminating with nut, bolt, spring washer etc, as required.(Jointing shall be done with 3 sets of GI nut, bolt & spring washer)
Supplying and laying 25 mm x 3 mm copper strip at 0.50 meter below ground as strip earth electrode , including connection / terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm)
Supplying and providing "Excel" Earthing compound including mixing with excavated fine soil and water to make it as slurry and filling around the earth plate etc. as required.
SITC of a cubical type floor mounting energy meter box made from 2 mm thick MS sheet, powder coated in suitable colour over a coat of primer, separate cabin for each meter & hinged door with glass for meter reading from outside, cable entry/ wire way boxes for fixing 10 nos of 5-30A, Single phase L&T (150x130x30) energy meter. providing rubber beedings and marking the identification of meter for each apartment with white paint, fixing danger notice board etc as required. (The drawing of the cubicle box is attached with the Schedule.)
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .