Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | ₹9.5 L Quoted ₹9.8 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹10.2 L+₹40,217.12 (4.10%)Rejected-Finance | ₹10.2 L+₹40,217.12 (4.10%) | L2 | Rejected-Finance Other than L1, hence rejected |
| 3 | L3₹10.3 L+₹48,757.12 (4.97%)Rejected-Finance | ₹10.3 L+₹48,757.12 (4.97%) | L3 | Rejected-Finance Other than L1, hence rejected |
| 4 | Rejected-Technical | - | - | Rejected-Technical Docus not submitted |
Tender Value
Refer Docs
EMD Value
₹19,200
Closing Date
4 Nov 2020, 6:00 pmClosed
AGE (I) Naya Raipur
AGE (I) Naya Raipur Military Engineer Services C/O HQ COSA Near International Cricket Stadium Atal Nagar, Distt-Raipur (CG) Pin - 492101
REPAIRS TO ROOF CEILING, ROOF, SANITARY, FITTINGS, PLUMBING INCL INTERNAL WIRING AND FITTINGS AND FIXTURES AT KOTA RAIPUR
2020_MES_384199_1
8400/272/E8
Open Tender
Civil Works
Item Rate
120 days
AGE (I) Naya Raipur
Please refer tender documents
7 documents required · 7 mandatory
₹500
AGE (I) Naya Raipur
₹19,200
16 Dec 2020
7 Oct 2020
7 Nov 2020
7 Oct 2020
4 Nov 2020
21 Oct 2020
Amount
SCHEDULE 'A' PART-I (B & R PORTION)
Dismantling of Plain or corrugated steel sheeting, any gague, thickness, of roof coverings.
Dismantling of iron or mild steel work of any descripitiong like rafter, purlin etc complete
S&F for Pre painted galvalume aluminium zinc coating GI based semi corrugated steel sheet 0.50mm thick profil as approved by GE of an colour having tensile strength of 550mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified and directed by Engr-in-Charge.
S&F for Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering eaves board, gutter, valley and in cladding to wall fixed with self tapping screws all as specified and directed by Engr-in-Charge.
S&F 2mm thick fiber glass reinforced translucent corugated sheeting with two corrugations side laps fixed l type or J type or cranked hook bolts all as per directed etc.
All as per srl item No 1.05 above but plain sheet
S&F for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc of Fe 410-W(Gde-E-250) quality A
Dismantling of ceiling board (fiber pulp, insulation etc) or insulation board/slabs /blankets any thickness including cover fillets.
Dismantling of timber scatting 40 Sq cm or over in section in any position unframed.
M&L for 4 mm thick Asbestos cement, plain boards, fixed to walls and fixed with screws along with iron frame work all as per specified and directed by Eng-in-Charge.
M&L Fiber insulated PVC 6 mm thick, plainboard fixed to ceilings or flat in faceya fixed with screws along with iron frame work all as per specified and directed by Eng-in-Charge.
M&L for 2nd Class H/W plain fillets square rectangular or triangular in section clean swan, screwed with nails bords,sectional area exc. 3 Sqcm but n.exc 6 Sqcm.
M&L for three coats of white wasing on newly prepared ceiling surfaces.
M&L for two coat of synthetic enamel paint over one coat of pink primer on new wooden surfaces n.xec 10 cm width or girth including preparation surfaces.
Demolition of cement concrete (un reinforced) in ground floor & paving not exceeding 15 cm thick below or above ground level
M&L for 40mm thick PCC (1:2:4) type B1 using 20mm graded stone agg as in flooring finished even and smooth using extra cement.
Glass dividing strips 3mm thick and 38mm width
M&L for 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection laid to slope of 1 in 12 and finishing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges complete all as specified and directed.
M&L for average thick 40mm PCC 1:2:4, type B0, using 12.5mm stone agg as in roof etc.
Taking down GI tubing 20mm bore of pipe and connection including cleaning for refixing or removal to store.
Taking down GI tubing 15 mm bore of pipe and connection including cleaning for refixing or removal to store.
M/L for fixing steel water tubing of 20 mm bore medium grade fixed to wall ceiling or laid in floor.
M/L for fixing steel water tubing of 15 mm bore medium grade fixed to wall ceiling or laid in floor.
S/Fin repairs 10 Ltr capacity PVC valueless syphonic action type flushing cistern low level white with inlet valve floot and handle, incl bracket.
S/F in repairs vitreous china squatting pan “ Orissa pattern” size 580 x440 with ‘P’ or ‘S’ trap , incl connecting to trap and flusing pipe.
S & F viterous china Urinal bowl white, flat back size 465x35x265, with grating and union for discharge pipe (excluding flushing cistern,flash pipe, and wate pipe) as fixed in repair
S&F fixed in repair CP bib cock cast copper alloy (with crutch or butterfly handle, screwed down, for iron pipe or for brass ferrule and fixed 15 mm bore complete all as directed at site.
S/F in repairs stop valves CP screwed down high pressure with crutch or butter fly handle and fixed, 15 mm bore.
S&F Angle cock brass CP fixed in repairs
S&F in repairs brass CP Towel Rail 20mm dia, D type, 60cm long between flanges etc.,
S&F in repairs of Sheet glass shelf assembly conisting of 5.5mm thick sheet glass shelf 12cm wide with Chromium plated bracket guard and railing 60cm long.
S & F Vitreous china wash basin, white, flat back, size 550mm x 400mm including cutting for and pinning in ends of brackets and waste pipe.
M &L PVC connections 15mm size with PTMT nuts of length 600mm
S & F pillar tap cast copper alloy 15mm bore with capstan head, chromium plated, screwed down high pressure, with or with out lettered "Hot" or "Cold" with long screw shank and fly nuts, screwed for iron pipes.
S&F Sink with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs washers incl bedding in cement mortar to dwarf wall or incl fixing cantilever brackets and connecting union to pipe over all size 915 mm x 460mm bowl size 410mm x 330mm x 160mm
S/F grating doom 100mm dia of PTMT (min wt 25 gm) fixed in repair all as specified and as directed.
Demolition and breaking up drain pipes of Internal dia 100mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar
S&F for 110mm PVC(SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls.
–do- but 75 mm.
S&F for PVC (SWR) access door bends any radius 110mm dia.
–do- but 75mm.
S&F for PVC (SWR) branch pices of 110mm bore dia (single Y) equal or unequal with access door.
S&F for PVC (SWR) branch pices of 75mm bore dia (single Y) equal or unequal with access door.
S&F for 75mm PVC (SWR) floor/Nahani trap, plain with grating including jointing with solvent cement.
Dismantling boarding, any description, fixed in any position with nails complete.
M/L for Pre laminated partical boards 18/19mm thick, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame work.
M&L for 20mm thick 2nd class H/ w clean sawn boards width n.exc 20cm as in eaves board.
M & L Ply wood 4mm thick BWP fixed in ceiling fixed with nails all as specified and as directed.
S/F in repair floor door spring (Double spring) hydraulic regulated made upto minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover governing pivot made of brass, other part made of mild steel heavy duty all as specified and as directed.
Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed - Aluminium ((Die cast) body - S & F
Taking down of existing water tank of exc. 500 ltrs to n.exc 1000 ltrs, and removing to stores.
Taking down of existing water tank of exc. 250 ltrs to n.exc 500 ltrs, and removing to stores.
S&F 1000 ltr capacity Rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I,including 20 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &highdensity plastic ball screwed for iron pipe and fixed
S&F 500 ltr capacity Rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I,including 25 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &highdensity plastic ball screwed for iron pipe and fixed
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc - Capacity Exc 250 N exc 500 litres
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc - Capacity Exc 500 N exc 1000 litres
SCHEDULE 'A' PART-II (E & M PORTION)
Taking down carefully copper/Aluminum point wiring (light, fan, socket or power) complete, including fittings such as switches, ceiling roses, pendants, regulators sockets etc. and making good the disturbed surfaces of walls, floors etc and match with the existing colour of wall complete all as specified and as directed.
Taking down carefully sub main wiring of any Nos of wire & size with earth wire on wooden batten/surface PVC and metallic conduit/casing & capping with accessories complete all as specified and as directed.
M&L Point wiring complete with 1.5 sqmm PVC insulated stranded copper conductor multistand hrfr wire core cable drawn through and including rigid non metalic PVC conduit 20 mm dia ( meadium grade ) , ISI marked with concealed conduit wiring including cutting chases and making good in CM 1:3 & white/colour wash to match existing surface, pressed steel terminal boxes not less than 1.6 mm thick concealed in wall duly painted with two coat of black bituminous paint over a coat of red oxide primer, plastic laminated top sheet cover 2.8 mm thick of required size and colour for housing switches and sockets, 1.5 sqmm PVC insulated (green insulation) copper conductor as earth continuity cable drawn with wiring and connected to common earth dolly all as specified for -
(a) One light/Fan/Bell point controlled by one switch
(b) One light point controlled by two 2 way switch
(c) One socket out let 5 pin 5 Amp on independent board
(d) One socket out let 5 pin 5 Amp on same board
Description all as per item No 2.03 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated hrfr cable and unsheathed cable for 3/6 pin 5 & 15 Amp socket outlet controlled by one switch on independent board with and including 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed.
Taking down and S&F Switch modular, Single pole, one way, 6 amps, 230 Volts,all specifed and directed
Taking down and S&F Switch modular, Single pole, one way,16 amps, 230 Volts, all as specifed and directed
Taking down and Supply and fixing madular type socket 6/16 amps- 2/3 pin combined module box type (as per site required ).
Taking down and S&F switch modular, Single pole, two way, 6 amps, 230 Volts, all as spcified and directed
Taking down and Bell push /modular, Single pole, one way, 6 amps, 230 Volts, all as specifed and directed
Taking down and S&F socket modular, Single pole, one way, 6 amps, 230 Volts, all as specifed and directed
Taking down and S& F electronic fan regulator 5 step Two module of all as specifed and directed
Taking down and Supply & fixing moadular white cover plate with frame 6 way module type switch (as per site required).
Taking down and Supply & fixing moadular white cover plate with frame 8 way module type switch (as per site required).
Taking down and S & F SP, 40 Amps, 240 Volts , 10 KA , 'c' curve MCBs complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Taking down and S & F SPN, 32 to 63 Amps, 240 Volts , 10 KA , 'c' curve MCBs complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating). all as specifed and directed by engr-in-charge
Taking down and S & F TPN32Amps, 415 Volts , 10 KA , 'c' curve MCBs complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating). all as specifed and directed
Taking down and S&F batten/angular lamp holder made up of bakalite complete all as specified and directed
Taking down and S&F ding dong bell 230 volt single phase complete all as specified and directed complete .all as specified and directed
M & L for sub main wiring with PVC insulated sheathed two single core 4 Sqmm hrfr and One No. 2.5 Sqmm single core cable stranded copper conductor 1100 Volt grade hrfr to be use as continuous earth connected to earth drawn into PVC conduit/Casing N capping size not less than 25 mm (medium grade) with all accessories complete all as specified and as directed. Note : Two runs of cable for Sub Main and One run of earth wire shall be measured as One length with PVC conduit / casing-N-caping. all as specifed and directed
M & L for sub main wiring with PVC insulated sheathed two single core 6 Sqmm hr fr and One No.4 Sqmm single core cable stranded copper conductor 1100 Volt grade hrfr to be use as continuous earth connected to earth drawn into PVC conduit/Casing N capping size not less than 25 mm (medium grade) with all accessories complete all as specified and as directed. Note : Two runs of cable for Sub Main and One run of earth wire shall be measured as One length with PVC conduit / casing-N-caping. all as specifed and directed
S & F in repaires of batten for LED tube light fitting with suitable for 1 x 20 watts 230 volts 4 feet long Energy efficiency etc complete set with all accessories internally pre wired and incl connection from ceiling rose to tubelight fitting 3 core flexiable copper cable 0.75 sqmm approx 1.5 mtr long compete and connection. all as specifed and directed by engr-in-charge
Taking down defective fluorescent tube light fittings of any type, 1x36 watt. 1x 20 watt, 4x20 watt, CFL 2 x 36 watt, after disconnecting electrical connection and repairing the same including replacement of defective parts such as chokes, starter, bipin holder, base plate , PVC flexible copper three core wire, 23/0.0076 upto 1.5 meter length , all as required at site complete all as specified and as directed. all as specified and directed
Supply Only ( in repairs) Polycarbonate socket out let 2 in 1 socket 5 pin , (6 Amps ) flush type controlled by one switch, complete all as specified and directed by engr-in-charge
Supply Only ( in repairs) Polycarbonate Switch socket commination out let 2 in 1 socket 5 pin , (16 Amps ) flush type controlled by one switch, complete all as specified and directed by engr-in-charge
Supply Only ( in repairs) polycarbonate Switch piano flush type,SP, 6 Amps, one way ( ISI) marked of Anchor or equivalent of other specified make complete .all as specified and directed by engr-in-charge
Supply and fixing in repair /replacment of sheet metal enclosure DB 240 volt double door 240 volt with 200 amps bus bar 8 way all as specified and directed by engr-in-charge
Supply and fixing in repair /replacment of sheet metal enclosure DB 415 volt double door 240 volt with 200 amps bus bar 4 way all as specified and directed by engr-in-charge
Supply and fixng of single pole and neutral enclosure with a two pin and earth plug and earth socket complete with one single pole MCB 20 amps 240 volt
Earthing with Galvanised Iron Earth Plate Electrode 600X600X6mm size buried directly in Ground vertically at a depth not less than 2.25 METRE below Ground Level with the Top Edge of Earth Plate at a depth not less than 1.50 METRE below Ground Level connected to GI Strip 20X3.0mm as Earth Lead by means of Bolts, Nuts, Check Nuts and Washers of Galvanised Steel, Earth Plate Electrode surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers not exc. 150mm thick, Aluminium Strip protected with and including Galvanised Iron Pipe 40mm Bore (dia) Light Grade, upto 1.0 METRE above the Floor Level of the Building where Main Switch/DB situated including PCC Pit in Cement Concrete 1:3:6 (20mm Graded Stone Agg-regate) and RCC Cover of size 540X540X50mm in RCC 1:2:4 (20mm Graded Stone Aggregate) rein-forced with and including 8.0mm dia TMT Bars @ 100mm centre to centre both ways, Galvanised Iron Wire Mesh, Funnel, Galvanised Iron Watering Pipe 20mm Bore (dia) Medium Grade, necessary Excavation in Soft/ Loose Soil, returning, filling in and removal of surplus Spoil upto a distance of 50.00 METRE and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion including Taking down Unserviceable Earthing, complete all as specified and as directed.
Taking down of LED lamp of any type and capacity
Supply anf fixng in repair of LED lamp rotary type/holder type of 9 watt all as specified and directed by engr-in-charge
Takinf down cable from trench /wall any size and capacity
M&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 95 sqmm , 3.5 core.
M&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 50 sqmm , 3.5 core.
Excavation in trenches in any type of soil, n. exc. 1.5m wide and n. exc. 1.5m deep and getting out for laying of cables/pipes etc including forming bottom surfaces to the required level/slope complete, all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick in any type of soil complete, all as specified and directed..
Removal of surplus excavated soil to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above starting point complete, all as specified and directed..
Supply and spreading clean and dry fine sand free from sharp material (unwashed) laying in trenches around the cable for cushioning complete, all as specified and directed.all as specified and directed by engr-in-charge
M & L brick protection cover over cable of “Sub class 'B' laid dry over cable (length of brick shall be laid across the length of cable) complete, all as specified and directed.all as specified and directed by engr-in-charge
Total contracts sum shall be calculated after deduction of schedule of credit amount of Rs. 28,165.00
m/s ramanuj singh and sons
FIRST SOLAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .