Loading…
Loading…
Tender Value
₹9.4 L
EMD Value
₹18,760
Closing Date
23 Sept 2026, 4:00 pm
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX RAJ BAGH
Installation of two pot Garden Lights and CCTV Cameras at Sherwani Colony Khwajabagh Park Baramulla
2026_PWDJK_324047_1
NIT No.150//2026-27 Dt 09/09/2026
Open Tender
Electrical Works
Percentage
15 days
Sherwani Colony Khwajabagh Park Baramulla
Please refer Tender documents.
5 documents required · 5 mandatory
₹600
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹18,760
9 Sept 2026
9 Sept 2026
24 Sept 2026
9 Sept 2026
23 Sept 2026
9 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SITC of 2.5mtr decorative combo pole with 30W LED Post-Top Fitting made out of cast iron base of 625mm long and top 76mm MS Tube, having arrangement of 2 No's Flower Pot as per drawing. The pole having integral service connection box duly cover the same. The pole shall be primer & painted with polyurethane paint make ,Hi-Lite,/signify pvt India ltd/Homdec, Pole to be approved and inspected at OEM before its delivery. The expenses of boarding, lodging of two nominated inspection officers shall be borne by the successful bidder. The total height of pole shall be 2.5 m excluding the height of 0.58m of top luminarie. | 12 | no | 23,500 | ₹2,82,000 |
| 2 | SITC of 30 watt LED IP-65 fully weather proof LED Post-Top fitting made out of die cast Almunium, housing single piece bottom upto mounting of 60 mmOD Pole/pipe , size of fitting 580mm*340mm( Nominal) with opal acrylic protector duly silicon filled,UV Resistant P.U/Powder coated paint, lacquer coated as approved by not less than SDO. Further colour with highly effacing electronic external driver,high voltageprotection, power LED white/warm white mounted on MCPCB with better heat dissipation arrangement duly wired upto connector complete etc as required. Make of LED Phillips/Hi-lite/Wipro | 12 | No | 7,500 | ₹90,000 |
| 3 | Providing and laying of M15(1:2:4) Cement Concrete pole block of size ( 1.5ʹ x 1.5ʹ x 3ʹ) as *(1ʹ above ground & 2ʹ under ground in Height) including cost ofform work,Curing,Finishing & Base Mesh Reniforcement having 12mm dia main as well as temperature (spacing 6 inch C/C) with 04 No. of foundation bolts supplied with the pole and embedded in the concrete,6" dia. hollow space shall have to be provided in the concrete block for cable loop in and loop out.The job includes all charges (Complete Job).The Job Shall be Monitored by concerned sub-division baramulla site incharge (Civil Engineer) | 12 | No. | 7,500 | ₹90,000 |
| 4 | Providing service connection to be carried from pole junction box to luminaries using 3x1.5 Sq.mm FR-LSH multistrend copper wire confirming IS 694 ammended upto date of Polycab/Havells/AnchorMake. | 36 | Mtr | 267 | ₹9,612 |
| 5 | Providing of Pole Earthing Using 20mm GI Rod 10 ft to be driven Underground and connected with pole at earthing point through 8 SWG Wire including required Sizes/numbers of nuts bolts and thimbles Complete Job. | 12 | No. | 6,600 | ₹79,200 |
| 6 | Supply/Laying/Testing and Commissioning of following Al armored PVC cable withstand voltage of 650/1100V confirming to IS:1554(Part-I) Havells Make .The laying of cable shall be carried through existing HDPE Pipe carefully, to avoid any insulation damages/Kengs | - | - | - | - |
| 7 | 2-Core 16 sq mm Steel Armoured | 120 | RM | 250 | ₹30,000 |
| 8 | 2-Core 25 Sq.mm Steel Armoured | 50 | RM | 300 | ₹15,000 |
| 9 | Supply and laying of 2 inch dia HDPE pipe of Standard make having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 01Feet including excavation and Refilling the Trench. The Job includes repairing of the Roads and lanes which shall get effected due to this by way of laying cement concrete etc. | 120 | RM | 265 | ₹31,800 |
| 10 | Design,Supply, Installation, Testing and Commissioning of CPRI Approved (IS/IEC:61439) Main LT Control Double Door feeder panel outdoor type fabricated out of 16 gauge sheet steel. The feeder panel should have standing rain/ dust & vermin proof with gasket lockable door of 16 gauge sheet steel. The Panel should be painted with Electro static powder coated colour, Siemens grey structural with proper chemical pre-treatment with film thickness 35-40 Microns,duly fitted with Voltmeter, R/Y/B Phase-indicators etc & angle iron 50x50x6mm stand painted in black colour of 2.5 feet height above ground level and underground 1.5 ft to be grouted in cement concrete block of suitable size with the cc ratio of 1:2:4 mix. (However the angle iron stand overall height 4 ft shall be increased or decreased upto 1.5 foot depending upon site conditions)The feeder shall be suitable size in length breadth and height to be fitted inbuilt the following items:-
Incoming: 100 Amp-2 pole,35kA MCB with extended terminals Adjustable Thermal & Fixed Magnetic L&T/ABB/Legrand/Simens Make.
Outgoing: 150 Amp TPN Al. Bus bar & 02 No. 32 Amp 2 pole DP MCB L&T/Legrand/Schneider/Microtek Make.Further the Feeder Panel shall have provision to accomodate 08 NO single pole MCB’S of required capacity and also having sufficient space for cable entries at the bottom side. In addition the feeder shall be provided with a set of indicator,volt/ampere meter, selectro switches,CTs & Auto Electronic ON-OFF Digital Timer switch and required capacity of contactor. for operation of day light control to Auto operation of illumination lightings.The Job Shall also include Single Phase inbuilt Digital voltage stabilizer of 3.5 KVA rating of reputed make as desired by SDO. | 1 | No. | 58,000 | ₹58,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.82 MB
BOQ_1092351.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .