Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC | L1 | Accepted-AOC Acceptance of contract | |
| 2 | L2₹38.9 L+₹8.2 L (26.6%)Rejected-AOC 27 CHITRAKOOT ENCLAVE NEAR ANURAG NURSARY DEHRADUN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC R | |
| 3 | L3₹42.7 L+₹12.0 L (39.0%)Rejected-AOC WING NO 7 2 10 PREMNAGAR DEHRADUN UK | L3 | Rejected-AOC R | |
| 4 | L4₹42.8 L+₹12.2 L (39.6%)Rejected-AOC 63 MANDIR LANE BALLUPUR CHOWK DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-AOC R | |
| 5 | L5₹56.3 L+₹25.6 L (83.4%)Rejected-AOC | L5 | Rejected-AOC R |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
15 Jan 2022, 6:00 pmClosed
GE IMA Dehradun
GE IMA Dehradun
PROVN OF ADDN ALTN TO KITCHEN AT VB MESS EXTENSION OF SHED AND
2021_MES_493588_2
GE/IMA/102/2021-22 9165/E8
Open Tender
Support/Maintenance Service
Item Rate
120 days
GE IMA Dehradun
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE IMA Dehradun
₹97,000
Yes
25 Jan 2022
24 Dec 2021
17 Jan 2022
25 Dec 2021
15 Jan 2022
31 Dec 2021
Amount
Supply & fix stainless steel sheet gde 304, 1.00mm thick fixed with stainless screws with washer in wall cladding complete all as specified and directed.
Supply & fix stainless steel sheet grade 304, 1.0mm thick inside open channel including made to shape as per drain shape and fixed with SS screws at top complete all as specified and directed.
Supply & fix stainless steel gde 304 angle fixed with stainless screws at corner of wall & top of drain as a protection complete all as specified and directed.
Supply & fix stainless steel gde 304 grills, grating for drain in kitchen etc complete all as specified and directed.
Taking down existing Stainless steel sheet fixed in wall cladding & drain, cleaning all stains & finally buffing & polishing the sheet to make it stain/scratch free, shiny and refixing the same with stainless steel screws & washers.
M&L for brick work with sub class B bricks, straight or curved on plan exceeding 6m mean radious built in cement mortar (1:6) complete all as specified and directed.
Taking down cement plaster on brick or stone walling built in CM including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick plaster on brick work or concrete surface in CM 1:6 finished fair & even complete all as specified & directed.
M&L for machine cut kota stone slab flooring 18-20mm thick laid over 20mm thick cement sand screed CM 1:6 as base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab and rubbing and polishing complete all as specified and directed.
Dismantling of existing stone slab & tiles and cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 300 mm x 200 mm x 7mm thick, as in vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match with and including 10 mm thick rendering in cement mortar 1:4 finished rough surface to receive tiles including dismantling of existing wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete in ground floor and paving not exceeding 15cm thick (below or above ground level) complete all as specified and directed.
Dismantling of drain pipes salt glazed, AC or RCC drain pipes, jointed cement mortar including concrete fedding etc complete all as specified and directed.
S&F 200mm dia UPVC pipe class 3 (PN) 6 Kgf/Cm2 as in drain out of kitchen waste complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested suitable for 200mm bore of pipe complete all as specified and directed.
M&L for PCC 1: 3 : 6 type C1 using 20 mm graded aggregates in surface channels and drains including necessary use & waste of formwork and demolition of existing old cement concrete of any description complete all as specified and directed.
M&L for extra for forming fair finished drain or channel not exceeding 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation filling, mass concrete and sub base of floor etc complete all as specified and directed.
M&L for Mild steel framed work such as grills, grating etc with end of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing framed work of water tanks and similar work including pintel hinges, stops hand made sliding bolts etc complete all as specified and directed.
M&L for cutting and grinding of existing terrazzo/Kota stone floor/wall surfaces (2 cut) and finally finishing the surfaces uniformly by applying floor polish complete all as specified and directed.
M&L for cutting opening, through brick walls built in cement mortar for doors, window and other opening or enlarging existing opening converting window into door opening, etc or cutting out defective brick work for under pinning, including providing, fixing and removing shoring, cleaning and stacking bricks removing surplus serviceable bricks, hard-core etc to store and rubbish not exceeding 50 metre complete all as directed.
Forming jambs etc. to openings cement mortar 1:4 (to foregoing items) including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as directed.
Making good under cills or over arches in cement mortar 1:4, lintels and bressummers including all pinning when necessary complete all as directed.
Use and waste of formwork to sides and soffits of floors or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports etc. and similar work of fair finished flat surface of concrete complete all as specified and directed.
M&L for RCC 1:2:4, type B1, using 20mm graded stone aggregate, as in shelves, beams, lintel etc complete all as specified and directed.
M&L Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L Mild steel TMT bars 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S&F Ist class hard wood (teak wood) Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
S/F 35 mm thick Ist class hardwood (teak wood) Plain framed, panelled shutter (two panel) with lock rail and panel of 12 mm teak plywood with teak wood grains on both sides faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F MS work as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles complete all as specified and directed.
S & F 100mm size brass double acting hinges with phosphor bronzewirespring, bright polished, complete all as specified and directed.
S&F 150 mm size Brass handles cast type polished bright complete all as specified and directed.
S&F 200 mm size Brass tower bolt with cast sheet barrel of extruded section fixed with brass screws bright polish complete all as specified and directed.
250mm long brass sliding door bolt with sand or die cast brass hasp staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and directed.
S&F, Floor door stoper of brass body and tounge with hard drawn steel spring, overall length of cover plate140 mm, complete all as specified and directed.
Powder coated aluminium Anodized frame for doors , windows, ventilators, partition wall with one or more rebates including joining cleat for fixing etc complete all as specified. (Minimum thickness of powder coating not less than 50 micron) complete all as directed.
5.5mm thick glass fixed in aluminium door/window/partition fixed with rubber gasket and aluminium beading complete all as directed.
S&F for 5.0mm thick Figured glass, pin head type and glazing with rubber gasket and aluminium glazing clips, area in square not exceeding 0.5 sq. m in each pane complete all as specified and directed.
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing or removed from site with all fittings for 25 mm bore GI tubing.
S&F 15mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors including taking down existing old steel tubing etc complete complete all as directed.
S&F 20mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors including taking down existing old steel tubing etc complete complete all as directed complete complete all as directed.
S&F 25mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) complete and jointed, tested and fixed to wall and ceiling or laid in floors, complete all as specified and directed.
S&F 15mm bore long body bib tap chromium plated fancy type fixed in repair complete all as specified and directed. Make: ESSCO (Jaquar) cat No. SQT-512KN or equivalent of Make Marc
M&L PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, coping, benching, kneelers, apex stone, bed plates, kerbs, etc. including weathering, slightly rounded or chamfered angles and throating, including necessary from work etc complete all as directed.
M&L for 18-20mm thick granite (of any type) machine cut, laid over and incl 20mm thick cement mortar (1:6) and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations all as specified & directed.
M&L for Udaipur green marble work 18 to 20mm thick (table rubbed and polished) in floor, steps, jambs, pillars, window, cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade over 20mm thick screed bed in Cement mortar (1:4) complete all as specified and directed.
M&L for Preparation of new or previously untreated wooden surfaces of any description, not other wise described over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for Preparation of new steel/iron surfaces of any description, over 10 cm in width or girth and applying two coat of synthetic enamel paint with approved shade over a coat of red oxide primer complete all as specified and directed.
M& L for a coat of 2.00mm thick wall care putty on new plastered walls, ceiling etc any surfaces to receive primer coat as specified in respective items, all as directed.
M&L for Preparation of new plastered surfaces of wall and applying two coats of oil bound emulsion over a coat of cement primer complete all as directed.
M&L for complete removal of existing treatment from wall and washing, rubbing down and stopping of distempered and painted surfaces, preparing the surface with 2mm thick wall care putty and applying two coats of oil bound distemper over a priming coat complete all as specified and directed.
M&L for Preparation of old plastered/un-plastered surfaces of ceiling by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots including cornices etc and applying one coat of white wash on ceiling complete all as specified and directed.
M&L for Preparation of old painted wooden surfaces of any description, over 10 cm in width or girth and applying one coat of synthetic enamel paint with approved shade complete all as specified and directed.
M&L for Preparation of old painted steel surfaces of any description, over 10 cm in width or girth and applying one coat of synthetic enamel paint with approved shade complete all as specified and directed
Excavation in trenches not exceeding 1.5m wide and n.exc 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 Sqm on plan and not exceeding. 1.5 m in depth and getting out in any type soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in soil complete all as specified and directed.
Spreading and levelling of soil obtained from excavation in layers not exceeding 25cm and well ramming including watering as required complete all as specified and directed.
M&L for rendering 15mm thick plaster on brick work or concrete surface in CM 1:4 finished fair & even complete all as specified & directed.
S&F Pre- painted galvalume aluminium Zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete complete all as specified and directed
S&F Pre- painted galvalume aluminium Zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding ridges to wall, fixed with self tapping screws etc complete complete all as specified and directed
M&L for hard core of broken stone gauge not exceeding 63mm, deposited, spread and levelled in layer not exceeding 15 cm thick watered & rammed to a true surface complete all as specified and directed.
S&F Rolled structural mild steel work as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
M&L Preparation of new plastered surfaces of ceiling and applying three coats of white wash etc complete all as directed.
M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed.
M&L 75 mm thick PCC 1;3:6 type C-2 using 40mm graded stone aggregate as in plinth protection or similar places and finishing the surface even & smooth with out using extra cement including making joints 12mm wide to the full depth of PCC at every 3 meter and every change of direction and filling the same with mixture of bitumen & sand in ratio (1:1) by weight including necessary form work etc and complete all as specified and directed.
M&L Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete, all as specified and directed.
Dismantling of existing roof tursses & housing and re-fixing after repair complete all as specified and directed.
Dismantling plain or corrugated steel sheeting any gaugethickness in roof covering and rubbish off the premises complete all as specified and directed.
Taking down carefully existing aluminum/copper surface/concealed point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces in CM 1:3 of walls, floors, ceiling etc including distempering to match with existing surfaces complete all as specified and directed.
M&L for point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLS having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area drawn in and including PVC conduit concealed and 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable FRLS as continuous earth conductor, connected to earth dolly by providing suitable lugs with inner and outer frame plate matching with surrounding with sunken steel boxes zinc oxide plated of suitable size for mounting modular switches, sockets etc complete for the following:- Note:- (i) Point wiring & earth wire shall be connected to each & every sunken box. (ii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.(iii) Modular cover plate with frame and sunken steel boxes zinc oxide plated as per site requirements shall be included in quoted rates.
One light point controlled by one, one way Modular switch 6 Amps
One fan/exuast fan point controlled by one, one way Modular switch 6 Amps
One 5 pin 5 Amps switch socket outlet point controlled by one Modular switch on independent boad.
One 5 pin 5 Amps switch socket outlet point controlled by one modular switch on the same board.
Description all as per item No 61 here in before but point wiring with 2.5 sqmm multistrand copper conductor cable for one five pin modular socket outlet 15 Amps controlled by one way modular switch on independent board and 2.5 sqmm PVC insulated multi strand copper conductor cable as continous earth wire.
S&F Modular switch single pole one way 6 Amp complete all specified and as directed
S&F Modular switch single pole one way 16 Amp complete all specified and as directed
S&F Modular socket outlet 2/3 pin combined 6 Amp 240 volts complete all specified and as directed
S&F Modular socket outlet 2/3 pin combined 16 Amp 240 volts complete all specified and as directed
S&F Fan regulator modular step type 120W 240 volts 2 module type complete all as specified and directed.
S&F Ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate /isolated body complete all specified and as directed.
S&F in repairs round plastic laminated sheet for mounting ceiling rose and batten holder complete all specified and as directed.
M&L Sub main wiring with two run single core PVC insulated unsheathed FRLS cable 1100 Volt grade, 10 Sqmm size with multi stranded copper conductor drawing into and including 20mm dia rigid PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed 10 Sqmm FRLS cable with multi stranded copper conductor as a earth continuity and connected upto DB including taking down old unserviceable submain wiring etc complete all specified and as directed.NOTE: (i) Two run of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit.(ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface/concealed with using PVC rawl plugs etc complete all specified and as directed.
M&L Sub main wiring with two run single core PVC insulated unsheathed FRLS cable 1100 Volt grade, 6 Sqmm size with multi stranded copper conductor drawing into and including 20mm dia rigid PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed 6 Sqmm FRLS cable with multi stranded copper conductor as a earth continuity and connected upto DB including taking down old unserviceable submain wiring etc complete all specified and as directed.NOTE: (i) Two run of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit.(ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface/concealed with using PVC rawl plugs etc complete all specified and as directed.
M&L Sub main wiring with two run single core PVC insulated unsheathed FRLS cable 1100 Volt grade, 4 Sqmm size with multi stranded copper conductor drawing into and including 20mm dia rigid PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed 4 Sqmm FRLS cable with multi stranded copper conductor as a earth continuity and connected upto DB including taking down old unserviceable submain wiring etc complete all specified and as directed.NOTE: (i) Two run of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit.(ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface/concealed with using PVC rawl plugs etc complete all specified and as directed.
M&L Sub main wiring with two run single core PVC insulated unsheathed FRLS cable 1100 Volt grade, 2.5 sqmm size with multi stranded copper conductor drawing into and including 20mm dia rigid PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed 2.5 Sqmm FRLS cable with multi stranded copper conductor as a earth continuity and connected upto DB etc complete all specified and as directed.NOTE: (i) Two run of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit.(ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface/concealed with using PVC rawl plugs etc complete all specified and as directed.
M&L Sub main wiring with four run single core PVC insulated unsheathed FRLS cable 1100 Volt grade, 10 Sqmm size with multi stranded copper conductor drawing into existing conduit as required including two run of two core PVC insulated unsheathed 10 Sqmm FRLS cable with multi stranded copper conductor as a earth continuity and connected upto DB including taking down old unserviceable submain wiring etc complete all specified and as directed. NOTE: (i) Four run of single core PVC cable with two run of earth conductor shall be measured as one unit complete all specified and as directed.
M&L Sub main wiring with four run single core PVC insulated unsheathed FRLS cable 1100 Volt grade, 6 Sqmm size with multi stranded copper conductor drawing into existing conduit as required including two run of two core PVC insulated unsheathed 6 Sqmm FRLS cable with multi stranded copper conductor as a earth continuity and connected upto DB including taking down old unserviceable submain wiring etc complete all specified and as directed.NOTE: (i) Four run of single core PVC cable with two run of earth conductor shall be measured as one unit complete all specified and as directed.
Supply and fix in replacement of metal body exhaust fan 600 mm sweep, 900 rpm 230 volts 50 Hz, heavy duty energy saving model single phase copper wound motor, grey in colour complete with blade, box type louvers etc incl fixing over the wall including opening and finishing the wall complete all as specified and directed.
M&L for Distribution boards epoxy powder coated TP & N 12 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 250 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one FP MCCB 100/125/160 Amps as incomer and 36 SP MCBs or 4/8/ 12 TP MCBs (or any combination of SP/TP MCBs ) outgoings complete including disconnecting and taking down existing DB complete all as specified and directed. (Note: Suitable MCCB and outgoing MCBs will be measured separately under relavant items of this schedule)
M&L for MCCB, 125 Amps, 4 pole, 415 volts with rupturing capacity 16 KA with thermal magnetic release and adjustable overload setting having including taking out existing unserviceable MCCB complete all as specified and directed.
MCB DB, sheet metal enclosures double door SPN 4 way with 200 Amps rated bus bar 415 volts 2 in 1 shutter (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed.
MCB DB, sheet metal enclosures double door TPN 4 way with 200 Amps rated bus bar 415 volts 2 in 1 shutter (METAL DOOR) type with blanking plates where required and IP 43 degree protection fixed in repair complete all as specified and directed.
M&L for MCB DB, sheet metal enclosures double door SPN 12 way with 200 Amps rated bus bar 240 volts 2 in 1 shutter (METAL DOOR) type with blanking plates where required and IP 43 degree protection fixed in repair complete all as specified and directed.
Sheet metal enclosure, single pole and neutral with three pin and earth plug and socket with and including one single pole MCB 20 Amps, 240 volts,10 KA complete fixed in repair all as directed.
Sheet metal enclosure, triple pole and neutral with three pin and earth plug and socket with and including one four pole MCB 63 Amps, 415 volts,10 KA complete fixed in repair all as directed.
M&L for MCB/Isolator SP 6 to 40 Amps, 240 volts 'C' Curve 10 KA, including connection with suitable size copper lugs fixed in repair complete all as specified and directed.
M&L for MCB/Isolator SP 6 to 40 Amps, 240 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete all as specified and directed.
MCB SPN 40 to 63 Amps, 240 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete fixed in repair all as directed.
MCB TPN 63 Amps, 415 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete fixed in repair all as directed.
MCB TPN 100 Amps, 415 volts CB' Curve 10 KA, including connection with suitable size copper lugs complete fixed in repair all as directed.
Supply and fix in replacement of ceiling fan 1400 mm sweep, 230 volts 50 Hz, single phase, copper wound motor, pearl white in colour complete with blade, down rod , canopy and connected with ceiling rose etc complete all as specified and directed.
Supply and fix energy saving, environment friendly and robust highway/mediumbay, long life LED light fitting 150 W IP65 luminaire with high efficacy complete with all accessories including taking down existing fitting complete all as specified and directed. Make: Havells cat part No. SAUCERPLUSHBP150WLED85790DTOLTG or equivalent in Philips/Wipro.
Material and labour for surface and wall mounted LED batten fitting 40 watt smart bright waterproof IP65,dust and waterproof LED luminaire with polycarbonate housing suitable for wall and ceiling mount applications complete and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to walls including taking down existing fitting complete all as specified and directed. Make: Havells cat part No. STOUTPLUS1200BS40WLED857SPCHW or equivalent in Philips/Wipro.
Supply, laying,connecting & testing PVC insulated,armoured,heavy duty electroc cable with aluminium conductor , 1100 volts grade,cross-sectional area 35 sqmm,4 core including taking down old US cable complete all as specified and directed.
Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.3 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to centre both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , for pit cover including testing on completion complete all as specified and directed. Note:-After completion of work if desired test result is not obtained the earthing is to be redone without any extra cost to deptt.
M/S PUNDIR BUILDERS
M/S S P BUILDERS
Meher enterprises
Kum Kum construction co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .