Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹46.7 LAccepted-AOC 65 6 518 B 1 HIMACHAL NAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | 1 | Accepted-AOC After deducting SOC and Reduction for FH items | |
| 2 | 2₹49.5 L+₹2.7 L (5.71%)Rejected-Finance D NO 71 31 252 DURGANAGAR MALKAPURAM VISAKHAPATNAM 530011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
29 Mar 2021, 6:00 pmClosed
GE NAVAL BASE VISAKHAPATNAM
Garrison Engineer (Naval Base) Nausenabaugh Gandhigram PO Visakhapatnam 530 005
PROVN OF PARKING SHED OF A B AND C CLASS VEHICLES FOR MES OFFICE AT K SECTOR DOLPHIN HILLS CONSTRUCTION OF SECURED ROOM FOR INSTALLATION OF AUTOMATIC TELLER MACHINE ATM AT FLEET SPORTS GROUND PROVN OF GEYSER FOR K SECTOR DOLPHIN HILLS PROVN OF
2021_MES_409411_3
C/8823/E8 / Token 58 of 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE NAVAL BASE VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NAVAL BASE VISAKHAPATNAM
₹90,000
Yes
31 Mar 2021
9 Mar 2021
31 Mar 2021
9 Mar 2021
29 Mar 2021
16 Mar 2021
Amount
Excavating in post holes (or similar holes) each n. exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25cm, watering and removing surplus soil to a distance n. exc 50m and making good surface in hard/dense soil complete all as specified and directed.
M & L for Plain cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal of debris and rubbish to a distance upto outside MD land complete all as directed by the Engr-in-Charge
M & L for Chequered cement concrete tiles of size 20cm x 20cm x 25mm thick, as in floors etc, including 15 mm thick screed bed in cement mortar 1:6 and set & jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and directed.
S & F MS steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as speicfied and directed.
S & F Rolled mild steel in Plates (plain or chequered) channels fo grade Fe 410-W (Gde-E- 250) quality-A, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as speicfied and directed.
M & L for Mild Steel Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 ® complete all as specified and directed.
S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed.
S & F 1.00mm thick, Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed.
Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
M & L for Brick work with fly ash, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
M & L for Machine pressed precast conctete kerb stone of thickness 100mm to 110mm and width not less than 250mm of approved shape and size conforming to relevant IS, M-20 Grade as in edging with width equal to the thick of the stone including necessary excavation and earth work and fixing in cement mortar 1:4 and applying two coats of synthetic enamel paint of approved shade and pattern over a coat of primer complete all as specified and directed.
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed.
Removing excavated soils exc 250 m but n. exc 500 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish to a distance n.exc 100m as directed by the Engr-in-Charge.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Excavation over areas, n.exc 1.5 m in depth and getting out in soft/loose soil complete as specified and directed.
Excavation over areas, exc 1.5 m and n.exc 3.0m in depth and getting out in hard/dense soil complete as specified and directed.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed.
M & L for Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in foundations including rafts, footings, beams and mass concrete, etc complete all as specified and directed. (Note" Reinforcement will be measured and paid seperately)
M & L for Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in columns, pillars, posts and struts complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
M & L Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
M & L Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in chajjas etc complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
M & L for Reinforced Cement Concrete M-30 Design Mix (Using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, and in shelves and the like etc complete all as specified and directed. (Note: Reinforcement will be measured and paid seperately)
M & L for use & waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter complete all as specified and directed.
M & L for use & waste Formwork to sides of pillars, posts, struts, piers, columns and stanchions for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etcetc complete all as specified and directed.
M & L for use & waste Form work to chajjas, troughs and similar items including edges flat for rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed.
S & F high strength corrosion resistant TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
S & F high strength corrosion resistantTMT steel bars 6mm to 8mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
S & F high strength corrosion resistantMild steel TMT bars 5mm dia and over upto and including 10mm dia in strirrups, spacers and binders spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed.
M & L for brick work with fly ash bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls using old size brick complete all as specified and directed.
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
M & L for rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
M & L for moorum/red bajri filling under floors or in foundations including spreading, levelling, watering and consolidation complete all as specified and directed.
M & L for hardcore of gauge n.exc 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for 100 mm thick, plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub-base of flooring, etc complete all as specified and directed.
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed.
M & L for Vitrified, designed, coloured, tiles, 10 mm thick, (square/rectangular) polished, area of each tiles not exc 0.36 sqm, in floors, etc including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for Vitrified, designed, coloured, tiles, 10 mm thick, (square/rectangular) polished, area of each tiles not exc 0.36 sqm as in vertical surfaces such as skirting,dado, etc including 10 mm thick bedding in cement mortar 1:4 and necessary cutting of tiles complete all as specified and directed.
M & L for Antitermite treatment by treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
M & L for Antitermite treatment by treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M & L for Antitermite treatment by treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M & L for Antitermite treatment by treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
S & F Powder coated (minimum 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. (Note : (i) Thickness of aluminium section shall not be less than 1.5 mm).
S & F powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc.complete all as specified and directed.
S & F Powder coated (minimum 50 micron) Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. and anodised aluminium fittings such as peg stay 150mm long (01 No), hinge type B-21, 100mm long (02 Nos) and suitable size of handle complete all as specified and directed.
S & F 4.8 mm thick, sheet glass, ordinary quality and glazing with rubber gasket etc in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S & F 3 mm thick, figured glass, pin headed type, in square n.exc 0.5 Sqm in each pane complete all as specified and as directed.
M & L for 12 mm thick, Prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination fixed with screws to timber frame work complete all as specified and directed.
S & F 100 mm, 4 lever, Brass, Mortice Lock, vertical type complete all as specified and directed.
S & F Aluminium (Die cast) body door Closer hydraulically regulated, designation No 3, universal type, suitable for door shutter of 851 to 1000 mm in width and of weight between 61 to 80 Kg complete all as specified and directed.
S & F Floor door stopper of aluminium alloy body and tongue, anodised, 150 mm overall length of cover plate with hard drawn steel spring, fixed in floor complete all as specified and directed.
M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed.
M & L for preparation new external surfaces of wall, chajja, facia etc and applying two coats of water based acrylic weather proof exterior emulsion (exterior wall finish) paint over a coat of primer as per manufacturer's instruction complete all as specified and directed.
M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L for 10 mm thick screed bed in CM 1:4 mixed with WPC as per manufacturer's instructions over 25 mm thick PCC 1:2:4 type B-0 (12.5mm graded aggregate), as in levellig course, Supply and lay polymeric water proofing membrane of weight 3kg/sq.m incorporating a centre core of 90 micron thick HMHDPE film including coating the surface with a coat of water based bituminous primer @ 100gms/sq.m., followed by a coat of blown bitumen of grade 85/25 or 90/15 @ 1.2kg/sq.m. each at top and bottom of the membrane including sealing all joints by thermo fusion with minium 10cm overlap incl grovving & inserting in parapt wall all as per manufacturers instructions and applying two coats of aluinium paint over a coat of primer over the top surfaces complete all as specified and as directed. (Note: WPC shall be measured and paid seperately)
Removing excavated soils exc 500 m but n. exc 1.5 Km and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
S & F 15mm thick mineral fibre accoustic designer false ceiling with pin hole tiles of size 600x600mm board as per manufacturer's instructions with 25mm long self drilled and tapping screws having Phillips head with under head cutter at 200mm centre to centre including finishing the joints/cutting for hole of face board as per other requirements (such as lights/smoke detector etc) including S & F aluminium Anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium tee section of size 38mm x 25mm x 1.5mm thick for main runner, 25x25x1.5mm thick for cross runner and angle of size 25x25x1.5mm thick along the wall suspended with and including 4mm dia GI wire (upto 1200mm length) as in suspenders of ceiling members fixed in proper position adjustable levelby means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed.
S & F Steel rolling shutters, 1.25mm thickness of lath with out ball bearing, as specified including top cover, an-choring rod, hasp and staple and one shop coat of primer; erected in position as indi-cated, complete: push pull or manual type complete all as specified and directed.
M & L for granite stone slab (of any type) work (table rubbed or polished) as in floor, 18 to 20 mm thick, machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 15 mm thick screed bed in cement mortor 1:6 & cutting, polishing complete all as specified and directed.
M & L for stainless steel work as in hand rail, ladder, grill, post and similar work conforming to grade SS-304 including welding, buffing and necessary fixing arrangements like, stainless steel bolts etc complete all as specified and directed.
M & L for stainless steel square hollow section of grade SS 304 with combination of frame of size 40x40mm and 25x2.5mm for shutter (thickness not less than 2mm) as in door frame and shutter and necessary fixing arrangementscomplete all as specified and directed.
M & L Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in spiral stair case complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
M & L for use & waste Formwork to faces of Formwork to spiral staircases with sloping or stepped soffits including risers and stringers (excluding landing) for flat rough finished surfaces of concrete complete all as specified and directed.
Removing excavated soils exc 1.5 Km but n. exc 5 Km and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit not les than 20 mm dia medium grade (ISI marked) concealed / semi concealed/surface fitted type including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed, for one light/exhaust fan/fan point/call bell controlled by one way switch. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) The quoted rate is deemed to include cutting chases (if any) for concealed wiring including making good the same as per the existing one)
All as per item No. 74 above but for One 3/5 pin socket outlet 6 amps on independent board complete all as specified and as directed.
All as per item No. 74 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete all as specified and as directed.
S & F switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed.
S & F Switch socket combination 2 in 1, 5 pin, 6 Amps, flush type, 240 volts complete all as specified and directed.
S & F Switch socket combination 2 in1, 3 pin, 6 and 16Amp, flush type, universal complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor including complete all as specified and as directed. (Note :- Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length)
S & F Distribution Board, SPN 8 Way ,Double door with IP 54 protection complete all as specified and as directed. (Make : Indo Asian cat part No. 811826 [Optipro] or equivelant of make as perList of manufacturer's)
S & F MCB SP 6 to 32 Amps, 240 Volts, C Curve, complete all as specified and as directed (Make : Indo Asian Cat part No. 811122 to 811129 or equivelant of make as perList of manufacturer's)
S & F MCB SPN 40 Amps, 240 Volts, C Curve complete all as specified and as directed. (Make : Indo Asian Cat part No. 811152 or equivelant of make as perList of manufacturer's)
S & F UPS, 7.5 KVA capacity for minimum 30 minutes back up, single phase, AC input 160-260 Volts and output 230 +1% Volts complete all as specified and directed.
Supply and Install, 12 Volts, 150 AH battery with minimum 36 months warranty including PVC battery trolly rack of suitable size with castor wheels complete all as specified and directed.
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and as directed by the Engineer-in-Charge.
M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit not les than 20 mm dia medium grade (ISI marked) concealed / semi concealed fitted type to MS sunken/terminal/flush metal box suitable module for fixing modular switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed, for one light/exhaust fan/fan point/call bell controlled by one way switch. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one (iii) Metal flush box and white cover plate shall be measured and paid seperately)
All as per item No. 88 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
All as per item No. 88 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
All as per item No. 88 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 4 sqmm multistranded FRLS (ISI marked) and 4 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed.
S & F Modular socket outlet 6A, 2/3 pin combined, 2 module,AC 230V, 50HZ,conforming to IS 1293 :2005 (incl all revisons and amendments). complete all as specified and as directed.
S & F Modular socket outlet 6A/16A, 2/3 pin combined, 2 module,AC 230V, 50HZ,conforming to IS 1293 :2005 (incl all revisons and amendments) complete all as specified and as directed.
S & F Modular white cover plate with frame, but 2 module complete all as specified and as directed.
S & F Modular white cover plate with frame, but 3 module complete all as specified and as directed.
S & F Modular white cover plate with frame, but 4 module complete all as specified and as directed.
S & F Modular metal flush box, but 1/2/3 module complete all as specified and as directed.
S & F Modular metal flush box, but 4 module complete all as specified and as directed.
S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
S & F Distribution Board, TPN, 4 way, Double door with IP 54 protection complete all as specified and as diretced complete all as specified and directed. (Make: Indo Asian Indo Asian cat part No. 811857 or equivalent make as per List of Manufacturer's)
S & F MCB SP 6 to 32 Amps, 240 Volts, B Curve, complete all as specified and as directed (Make : Indo Asian Cat part No. 811008 to 811015[ Optipro] or equivelant of make as perList of manufacturer's)
S & F MCB SPN 6-32A Amps 240 Volts MCB B Curve , complete all as specified and as directed (Make : Indo Asian Cat part No. 811027 to 811034[ Optipro] or equivelant of make as perList of manufacturer's)
S & F MCB, TPN 63 Amps 415 Volts , C Curve , complete all as specified and as directed (Make : Indo Asian Cat part No. 811220[ Optipro] or equivelant of make as perList of manufacturer's)
S & F High Performance integrated IP20 LED Batten to create a sustainable lighting environment with surface/suspended mounting having an efficacy of 110 Lm/w, LED tube light fittings, retro bar professional WH 5700K to 6000K nad 2000 lumens of cool white with lamp and all accessories and connecting with up with suitable flexible cable complete all as specified and as directed. (Make: CG Cat No. CIS-305-40-57-SL-DP-NWH or equivelant of make as per list of manufacturer)
Supply, install, testing & Commissioning, Hi wall split type air conditioner with indoor and outdoor units complete with cordless remote control unit and with in-built ioniser and plasma filter for better indoor quality with minimum 3 Star Rating and EER 3.2 of capacity 2 TR complete with all connecting pipes and fixing accessories such as bracket etc complete all as specified and directed.
S & F voltage stabilizer for automatic operation,, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output of 230V with accuracy of +/- 2.5% variation of capacity 5.0 KVA complete all as specified and directed.
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core complete all as specified and directed. (Note: Excvation and earth work shall be measured and paid seperately)
S & F MCCB 415 Volt, 36 KA, 4 Pole, 200 Amps Capacity complete all as specified and as directed. (Make: /Indo Asian. Cat Part No. 830116 or equivelant of make as per List of Manufacturer's)
M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment)
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 2 with peak, size 300mm x 180mm x 40mm conforming to IS-5820-1970 complete all as specified and directed.
M & L for 40 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors complete all as specified and directed.
M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length)
S & F Concealed sheet metal enclosure with socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V, B-curve complete all as specified and as directed.
S & F copper tubing of 3/8" dia, 24 SWG thick with and including tubular insulation suitable for Split ACs complete all as per the existing make specification and as directed.
S & F copper tubing of 5/8" dia, 24 SWG thick with and including tubular insulation suitable for Split ACs complete all as per the existing make specification and as directed.
Supply, laying, connection and testing, 15mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
S & F 15 mm bore, gun metal Gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S & F 15 mm bore, bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
Supply, install, testing & Commissioning, Geysers, water heater, 25 ltrs capacity, Storage type electrically operated on single phase 230 Volts AC, BEE 5 Star Rating with Double Safety Thermostat, Multi-function Safety Valve, High Density Insulation, Cathodic Protection, Superior Quality Glass-lined Inner Tank, and Single/Dual Glass-coated Incoloy Heating Elements, 8 bars highest pressure rating with minimum five years warranty on inner tank, magnesium anode energy saving ISI marked complete including grouting of nuts and bolts on wall for propper hanging of geyser with all accessories and connection of inlet & outlet pipe line including connecting up with 3 single core PVC insulated, multistranded copper conductor cables complete all as specified and directed. (Make : Jaquar Model No. Elena Prime or equivelent model as approved by the Engr-in-Charge/GE)
S & F chromium plated brass connection tube, 450cm long with two brass union and check nuts for connections to 15mm bore pipe suitable for cold water complete all as specified and directed.
S & F chromium plated brass connection tube, 450cm long with two brass union and check nuts for connections to 15mm bore pipe suitable for hot water complete all as specified and directed.
S & F 2x2 recessed mounting panel light fittings, 36 Watt with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. VENUSNEOHE2X2R36WLED840PIRSENSOR or equivelant of make as per list of manufacturer)
Supply, install, testing & Commissioning, Addressable Inteligent Touch screen type fire alarm repeater panel with graphic display touch screen (480/272 TFT 4.3"), 14 LED front, 2 RS 485 for connection, 1 RS 232/micro USB for programming, Operating temperature 5 Deg C/ + 40 Deg C Power supply, 24 Volts DC including dismantling of existing fire alarm panel and deposited to MES Store yard complete all as specified and directed: (Make : Honeywell/Appollo/Seimens/Ceasfire/Cooper/Spancer Fire/Qutak/TATA)
Supply, install, testing & Commissioning, Multisensor Detector (comprises optical smoke and thermistor temperature sensor) including dismantling of existing multisensor detector and deposited to MES Store yard complete all as specified and directed and and comprising with following:- (i) Operating Voltage: 17-28 V DC (ii) Communication protocol: As per manufacturer's instruction 9V Peak-to-Peak (iii) Quiescent current: 500 µA average 750 µA peak (iv) Power-up-surge current: 1mA (v) Maximum power-up time: 10s (vi) Alarm LED current: 3.5mA (vii) Remote LED current: 4mA at 5V (measured across remote load) (viii) Clear air analogue value: 23 +4/-0 (ix) Alarm indicator: 2 colourless light Emitting Diodes (LLEDs); illuminated red in alarm optional remote LED (x) Dimensions: 100mm dia, 50mm height, 58mm height in base (xi) Weight: Detector: 105Kg, Detector in base: 160 Kg (xii) Materials: Housing: White polycarbonate V-0 rated to UL94, Terminals: Nickel plated stainless steel (xiii) Smoke element only: Chamber configeration: Horizontal optical bench housing infra-red emitter and sensor, arranged radially to detect forward scattered light (xiv) Sensor: Silicon PIN photo-diode (Make : Honeywell/Appollo/Seimens/Ceasfire/Cooper/Spancer Fire/Qutak/TATA)
S & F Addressable type manual call point resettable type including dismantling of existing call point and deposited to MES Store yard complete all as specified and directed: (Make : Honeywell/Appollo/Seimens/Ceasfire/Cooper/Spancer Fire/Qutak/TATA)
S & F Addressable type loop Open-Area Sounder Visual Indicator to make full use of the protocol and designed for use in indoor and open area including dismantling of existing system and deposited to MES Store yard complete all as specified and directed: (Make : Honeywell/Appollo/Seimens/Ceasfire/Cooper/Spancer Fire/Qutak/TATA)
S & F GSM/PSTN auto dialer alongwith activated Sim complete all as specified and directed: (Make : Compatible of make Honeywell/Appollo/Seimens/Ceasfire/Cooper/Spancer Fire/Qutak/TATA)
S & F repairs of 2 core twisted pair, 1.5 Sqmm size cable (nominal area) PVC insulated screen both inner and outer PVC sheathed FRLS, multistranded high conductivity annealed bare electrolytic copper conductor cable, 1100 Volts [ISI marked ] with propper pair indentification 1.2 Standard coforming to relevant IS complete all as specified and as directed.
M & L Earthing complete with copper earth plate electrode 600 mm x 600mm x 3.15 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with copper earth strip of size 20x3mm by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and as directed by the Engineer-in-Charge.
S & F earth continuity conductor or main earthing lead with copper strip of size 20x3mm mm, fixed to wall on batten or recesses or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all specification and directed.
S & F Vertical TPN DB double door for provision for four pole MCCB upto 125 A incommer 4 way 12 outgoing with IP 54 protectioncomplete all as specified and as directed. (Make : Indo Asian cat part No. 812040 or equivelant of make as per List of manufacturer's)
S & F MCCB 415 Volt 16 KA, 3 Pole, 100 Amps Capacity complete all as specified and as directed . (Make: /Indo Asian. Cat Part No. 830008 or equivelant of make as per List of Manufacturer's)
M & L for Sub main wiring with 4 runs of Single core 10 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 10 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 10 sqmm and one runs of 10 sqmm cable as earth wire and one run of conduit shall be measured as one length)
S & F 20 mm dia Rigid non-metalic PVC conduit exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm but n.exc 20 cm girth complete all as specified and directed.
SRI VENKATA SAI MANIKANTA CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .