Tender Value
₹9.5 L
EMD Value
₹10,000
Closing Date
25 May 2026, 6:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
Municipal Commissionar, AMC
Rate contract for Servicing, Repairing, Breakdown, Routine and Preventive Maintenance of 11 KV H.T. Switch gears, Transformer and L.T. electrical panel and equipment of at 02 years at NHL College and Other College/Hostel Buildings of AMC (Limit up to Rs.10 lacs).
303502
2026-27
Open
Miscellaneous Works
Ahmedabad
3 documents required · 2 mandatory · 1 optional
₹900
Municipal Commissioner, Ahmedabad
₹10,000
8 May 2026
8 May 2026
8 May 2026
25 May 2026
8 May 2026
(Technical Bid only) of Record Office, Mezzanine Floor, “B”-
Tender in Physical form Block, Sardar Patel Bhavan, Danapith,
Ahmedabad-380001.
4 Tender Vol-I (Technical Bid on 26/05/2026, 04:05 pm onwards
only) Opening Date, Time Online Opening:- At the Office of
and Place Additional Chief Engineer(Electrical),
Light Department, 5th Floor, “C”-Block,
Sardar Patel Bhavan, Danapith,
Ahmedabad-380001.
Physical Opening:- At the Office of
Tender Officer, Central Record Office,
Mezzanine Floor, “B”-Block, Sardar
Patel Bhavan, Danapith, Ahmedabad -
380001 or at the above said office.
MUNICIPAL COMMISSIONER
Ahmedabad Municipal Corporation
Sardar Patel Bhavan, Danapith
Rate contract for Servicing, Repairing, Breakdown, Routine and
Preventive Maintenance of 11 KV H.T. Switch gears, Transformer and
L.T. electrical panel and equipments for 02 years at NHL College and
Other College/ Hospital/ Hostel Buildings of AMC (Limit up to Rs.10
Work Description No./set GST in Rs.
Erection, testing and commissioning of 11 K.V
Erection, testing and commissioning of 11 KV of
Dismentaling, Loading, Unloading and Shifting of 1 job
11 KV Switch Gear within 25 K.M. Limit.
(a) Testing and commissioning of transformer up to
5 (b) As above for 500 KVA up to 1000 KVA 1 job
6 (c) As above for 1000 KVA up to 1500 KVA 1 job
Testing and calibration of relay series coils for
KV breaker. Relay testing through secondary
injection method (O/C & E/F Relay) of 11 KV
Overhauling of complete transformer with IR Test,
BDV Test of oil, Ratio Test, Magnetizing Current
Test including changing of complete oil, cock
8 sheet, Bushing oil sheel, gaskets, packings, 1 job
dehydrating of windings & cores & tighting of nut,
bolts, insulator & insulator rods / studs (X'mer oil
Supplied by AMC) upto 1500 KVA
Replacing cock sheet packing for H.T./ L.T. cable
9 box of Transformer. (including ISI 1 job
mark,TR7/TR9 Grade material )
Comprehensive, Repairing, Servicing and Fixing of
10 5 Amp. relay series coil with assembly in 11 KV 1 job
Comprehensive repairing, servicing and fixing of
11 CT Wiring for 11 KV breaker. 1 job
Measurement of earthing resistance by loop test
Providing and Eracting end termination for 11 KV
XLPE cable including all cable jointing material
with alum. crimping type lugs(M-Seal/3M make
Heat Shrinkable kit)
(a)3C X 50/70 sq.mm. 11 KV XLPE cable
14 (b) 3C X 95/ 120 sq.mm. 11 KV XLPE cable Indoor 1 job
(c) As above for 3C X 150 sq.mm. 11 KV XLPE
(d) As above for 3C X 185 sq.mm. 11 KV XLPE
(e) As above for 3C X 240 sq.mm. 11 KV XLPE
cable end termination by crimping method of
following sizes of 1.1 KV grade PVC insulated, 1 job
armored cable with alum. lugs.
(a) As above for2.5 to 16 sq.mm. cable 1 job
19 (b) As above for 25 to 50 sq.mm. cable 1 job
20 (c) As above for 70 to 120 sq.mm. cable 1 job
21 (d) As above for 150 to 185 sq.mm. cable 1 job
22 (e) As above for 240 to 300 sq.mm. cable 1 job
Making straight through joint for 1.1 KV LT
23 Alluminium PVC/XLPE cable with M-Seal make 1 job
Cast tex Kit. (a) Upto 25 sq.mm.cable
24 (b) As above for 35 to 95 sq.mm. cable 1 job
25 (c) As above for 120 to 300 sq.mm. cable 1 job
Making straight through joint for 11 KV grade
XLPE cables of following sizes along with supply of
M-seal make Cast Tex jointing kit.
(a) 3C X 50/70/95 sq.mm. 11 KV XLPE cable
27 (b) 3C X 120 sq.mm.XLPE cable 1 job
28 (c) As above for 35 to 95 Sq.mm 1 job
29 (d) As above for 3C X 185 sq.mm. XLPE cable 1 job
30 (e) As above for 3C X 240 sq.mm. XLPE cable 1 job
Providing and erecting HOT deep Galvanised iron KG
strip wire 8 to 16 SWG.
Routine and Preventive Maintenance and
Overhauling work of HT switches/OCB/VCB
including cleaning of contacts, bus bars & circuit
chamber, overhauling of operating mechanism,
replacing of oil, etc. (new tested oil to be supplied
by AMC at site)
33 Filtration of Transformer oil at site Per Ltr. (a) Upto per litre
500 KVA Transformer
34 (b) As above for 500 KVA Transformer per litre
35 (c) As above for Filtration of oil in barrel at work per litre
Routine and preventive maintenance of
transformers including cleaning, replacing of silica,
checking IR value of HV winding and testing of oil
(new tested oil to be supplied by AMC at site).
Labour charges for fixing of palm connector and
37 bush bar with drilling holes. 1 job
Supply,Installation & testing of Closing /Tripping
38 Coil (with neccessary wiring if required) 1 job
Supply, Installation & testing of 70 Watt Heaters
39 for HT VCB panel (with neccessary wiring if 1 job
Labour charges for replacing spares of OCB / VCB
40 / Isolator / SFU (excluding supply of material) (a) 1 job
Monoblock per set of
41 (b) As above for Main contact set of 3 1 job
42 (c) As above for Tank bushing per 1 job
(d) As above for CT’s per No. including checking
43 ratio by primary injection & HV test 1 job
(e) As above for Heater commissioning with wiring
44 per No (excluding supply of material) 1 job
45 (f) As above for Vaccum Interptor 1 job
(g) As above for Reinsulating of bush bar per
47 Supply of tested transformer oil. Ltr
Supply of brass wiping gland for 11 KV PILC cable
48 for 3C x 70 sq. mm cable. 1 job
Attending oil leakage from gasket or HT/LT
bushings of transformer.(Per Each Bushing with
new gasket)(a) Transformer with horizontal bushing
(b) As above for Transformer with vertical bushing
(c) As above for Repairing work of conservator tank
Pressure testing of 11 KV cable / mono block of HT
Dismentaling,Loading ,unloading and shifting and
Refitting of transformers up to 1250 KVA/
Complete LT Panel/H.T. Panel/CSS from any AMC
Disconnection of H.T./ LT cables from transformer
Routine Maintenance and overhauling work of
PMCC/LT Panel work includes cleaning of panel
55 from inside and outside, Servicing of LT breaker, 1 job
Contactor, tightening of all the connections,cable
connections. (only labour work)
Maintenance and overhauling work of capacitor
Attending Fault of 11 KV switchgear (in Busbar /
Spout Assy /CT) including carbon cleaning and
re-insulation of Busbar chamber and DG set for
temporary power supply.
58 Painting of TR up to 1250 KVA Outside Painting. 1 job
59 MS Fabrication Work as per requirement per KG Per KG
Dismantling & disconnection of 11 K.V breaker/ 1 job
Labour Charges for attending Borewell Starter panel 1 job
61 Electric Fault. (Required material will be isuued by
HT - LT cable fault finding with High voltage thumper 1 job
62 machine (Minimum Charges
up to 0-50 MTR)
63 As Above (for more than 50 MTR) Rate / Mtr. 1 mtr
Carry out routine maintenance and servicing and
testing up to 6300 Amp L.T. ACB with below defined
scope: (1) Cleaning of dust,spider web ,foreign
particles. Etc . (2) Removal of old grease with new
grease for various parts.(3) Cleaning of various parts
64 with CRC.(4) Check the tightness of all hardware (5) 1 job
Checking of Spring Charging, Closing & Tripping
mechanism (11) Measurement of IRV (12) Measuring
of closing/tripping time by time testing kit (13)
Measuring contact resistance by CRM kit.(14)
Release testing by OEM recommended testing kit.
Carryout routine maintenance and servicing of L.T.
cubical panel board having approximately 15 to
Nos. of switches cleaning and servicing the contacts
65 with CRC, tighting the connections of incoming and 1 job
outgoing cables. and checking the operating
mechanism for smooth functioning of switches. and
putting them in smooth working order.
Replacing old and unserviceable Gasket of Top cover
plate of Transformer having following capacity.
(A) 250 KVA 1 job
67 (B) 315 KVA 1 job
68 (C) 500 KVA 1 job
69 (D) 750 KVA 1 job
Replacing the Valve of the Transformer of rating
71 KVA of following size
Replacing the oil level glass of the 1 No
Replacing the breather of the Transformer of
76 following capacity.
(A) 250 KVA / 315 KVA 1 No
Repairing of off load Tap changer of 250 / 315 / 1 No
78 500 / 750 / 1000 /1250 KVA Transformer.
Replacement of off load Tap changer of 250 KVA / 1 No
79 315 / 500 / 750/1000/1250 KVA Transformer
Carrying out various routine test as per instruction
80 of in charge for following capacity transformer.
(A) 250 KVA / 315 KVA 1 job
81 (B) 500 KVA / 750 KVA/ 1000 KVA/1250 KVA 1 job
Supplying & fixing Steel Chequered Plate having
7 mm thickness,with handle duly painted with Sq.Mtr.
two coats of black Japan colour. (Average Wt
Supplying Rubber matting of following thickness
as per IS:15652/ IEC 61111
Providing and fixing printed Instruction chart both 1 No
in English and Gujarati and duly framed with front
glasses, for treatment of person suffering from
Electric shock with minimum 50" diagonally size.
Supplying stand first AID box with antiseptic 1 No
cream, medicine for use on wounds due burn,
crepe bandage, gauge bandage, medicated ready to
87 use bandage (Band-aid) adhesive tape for
medicinal user, Scissors, anti-septic solution
(Savlon or similar) etc. (All above contents shall be
of standard makes)
Providing and erecting Mains with ISI marked, 1.5KV
grade electrolyte multi stranded, annealed copper
conductor with heat resistant PVC insulated
conforms to IS 694, IEC - 227 erected in existing pipe
of following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring) with
required size of copper lugs, nuts and bolts if required.
(j) One wire 50.00 sq. mm Mtr.
89 (k) One wire 70.00 sq. mm Mtr.
90 (l) One wire 95.00 sq. mm Mtr.
91 (m) One wire 120.00 sq. mm Mtr.
92 (n) One wire 150.00 sq. mm Mtr.
Carrying out the testing of earth fault and 1 Job
overload relay by authorized person ,on L.T. side.
93 by removing the fault of relay by checking the trip
devices, control wiring and putting the same in
working order with test report
Providing and erecting ISI Marked 3core 50 Sq.mm Mtr
XLPE insulated 11 KV armoured cable Aluminium
94 conductor IS-7098 to be laid on wall with clamps
or in provided cable trench / pipe in approved
manner as directed.
Providing and erecting ISI Marked 3 core 70 Sq.mm Mtr
XLPE insulated 11 KV armoured cable
95 Aluminium conductor IS-7098 to be laid on wall
with clamps or in provided cable trench / pipe
approved manner as directed.
Providing and erecting ISI Marked 3 core 95 Sq.mm Mtr
XLPE insulated 11 KV armoured cable
96 Aluminium conductor IS-7098 to be laid on wall
with clamps or in provided cable trench / pipe
approved manner as directed.
Providing and erecting ISI Marked 3 core 120 Mtr
Sq.mm XLPE insulated 11 KV armoured cable
97 Aluminium conductor IS-7098 to be laid on wall
with clamps or in provided cable trench / pipe
approved manner as directed.
Providing and erecting ISI Marked 3 core 150 Mtr
Sq.mm XLPE insulated 11 KV armoured cable
98 Aluminium conductor IS-7098 to be laid on wall
with clamps or in provided cable trench / pipe
approved manner as directed.
Providing and erecting ISI Marked 3 core 185 Mtr
Sq.mm XLPE insulated 11 KV armoured cable
99 Aluminium conductor IS-7098 to be laid on wall
with clamps or in provided cable trench / pipe
approved manner as directed.
Making trench in soft soil of suitable width of 90 cm
deep for laying cable or locating the fault all over the
run and back filling the same and making the
surface as normal ground.
Making trench in Hard Murrum / Tar Road of
suitable width of 90 cm or required depth for laying
any size of cable or locating the fault all over the run and Mtr.
101 back filling the same and making the surface as normal
(B) If additional machinery like hammer driller or JCB
Covering of cable with second class bricks or cement
102 tiles laid cover the cable crosswise & also on both sides with Mtr.
covering of 7. 5 Cm. layer of sand above & below cable (16
bricks per meter)
Drilling the road without breaking the road surface
(Asphalt) for laying of cable for feeding power supply by
103 making up to following size of holes at both ends complete.
(A) Up to 100 mm bore dia Mtr.
104 (B) Up to 150 mm bore dia Mtr.
providing and erecting Approved make Four pole
moulded case circuit breaker having breaking capacity ICU
of 25 KA. at 415 V,having normal current rating up to
105 25 A to 100A. with Fixed thermal & magnetic release
suitable to work on A.C. supply 50 c/s. with all internal
connections & complete erected in existing 16 G.M.S.
ICS=100% of ICU only Cat III 1 No.
providing and erecting Approved make Four pole
moulded case circuit breaker having breaking capacity ICU
106 of 35 KA. at 415 V. having normal current rating 125A.
with Fixed thermal & magnetic release suitable to work on
A.C.supply 50 c/s. with all internal connections & complete
erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III 1 No.
providing and erecting Approved make Four pole
moulded case circuit breaker having breaking
capacity ICU of 35 KA. at 415 V. having Normal
107 current rating 200A.with variable Thermal &
magnetic release suitable to work on A.C.supply
50 c/s. with all internal connections & complete
erected in existing 16 G.M.S.housing
ICS=100% of ICU only Cat III 1 No.
providing and erecting Approved make Four pole
moulded case circuit breaker having breaking
capacity ICU of 35 KA. and above at 415 V .
108 having normal current rating 250A. with variable
thermal & magnetic release suitable to work on
A.C.supply 50 c/s. with all internal connections &
complete erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III 1 No.
providing and erecting Approved make Four pole
moulded case circuit breaker having breaking
capacity ICU of 50 KA and above at 415 V having
109 Normal current rating 400A. with variable
Thermal & magnetic release suitable to work on
A.C.supply 50 c/s. With all internal connections &
complete erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III 1 No.
providing and erecting Approved make Four pole
moulded case circuit breaker having breaking
capacity ICU of 50 K.A. and above at 415 V
having normal current rating up to 630A. with
variable thermal & magnetic release suitable to
work on A.C.supply 50 c/s. with all internal
connections & complete erected in existing
ICS=100% of ICU only Cat III 1 No.
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor
for 1.1 KV. to be laid on wall with necessary clamps
or in existing trench / pipe of following size of cables
112 (A) 3 1/2 core 25 Sq. mm ( 16 Sq. mm 1/2 core) Mtr.
113 (B) 3 1/2 core 35 Sq. mm ( 16 Sq. mm 1/2 core) Mtr.
114 (C)3 1/2 core 50 Sq. mm ( 16 Sq. mm 1/2 core) Mtr.
115 (D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core) Mtr.
116 (E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core) Mtr.
117 (F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core) Mtr.
Supplying & erecting XLPE(IS:7098)(I)-88 ISI
unarmoured copper cable 1.1 KV grade to be erected
118 as directed of following size.
(K) 4 core 4 Sq. mm Mtr.
119 (L) 4 core 6 Sq. mm Mtr.
120 (M) 4 core 10 Sq. mm Mtr.
Providing and erecting XLPE (IS:7098)(I)-88 ISI
armoured cable multistrand / Solid Aluminium
conductor for 1.1 KV. to be laid on wall with
121 necessary clamps or in existing trench / pipe of
following size of cables
(A) 4 core 4 Sq. mm Mtr.
122 (B) 4 core 6 Sq. mm Mtr.
123 (C) 4 core 10 Sq. mm Mtr.
S.I.T.C. of Approve make Capacitor Bank (L&T, ABB, Per
124 Concap) KVAR
HT, LT STATUTORY APPROVALS (NOC WORK
Charges for approval for Making drawings, preparing
125 sketches, procedure for NOC FOR HT,LT POWER 1 job
CONNECTION building the premises obtaining the necessary
clearances from the Electrical inspector / competent
Authorities for the total Electrical installation, co-ordinating
with various agencies.
HIGH RISE AND STATUTORY APPROVALS
(LIOSNING WORK FOR HIGH RISE)
Charges for approval for Making drawings,
preparing sketches, procedure for NOC FOR
126 HT,LT POWER CONNECTION building the 1 job
premises obtaining the necessary clearances from
the Electrical inspector / competent Authorities for
the total Electrical installation, co-ordinating with
various agencies.
Providing and fixing 1.20 Metre high fencing with
2.0 Metre long M.S. Angle posts 40mm x 40 mm x6
mm and oil painting 3 coats fixed at 2.5 Mt,C/c.
with fiveHorizontan lines and two diagonals of
127 galvanised steel barbed wire weighting 9.38 Kg. per
100 Metre, strained and fixed to posts with
G.I,staples including fixing thepostsin ground with
0.5 M x 0.5.M x 0.5 M. block in C.C1:5:10 etc
128 Energy Audit of HT service per KW.
(Note:-Energy audit by Government approved per KW
Energy Auditor)
129 Replacement following faulty parts of 11 KV HT
panel i/c testing, commissioning etc complete as
(A) 11 KV VCB CT set 1
130 (B) 11 KV VCB PT set 1
131 (C) 11 KV VCB Vacuum Chamber/Bottle 1
132 (D) Power Pack Battery Back Up with required
133 (E) VCB Spring Charging Motor 1
134 (F) Microprocessor Relay 1
135 (G) Transformer Protection Relay 1
136 (H) Master Trip Relay 1
137 (I) Digital Amp Meter 1
138 (J) Digital Volt Meter 1
139 (K) TNC Switch 1
140 (L) VCB ON/OFF Mechanism Switch 1
141 (M) PT Fuse 1
Basic Amount in Rs.
Total Amount in Rs. (Including GST)
Total Amount in Rs. (Including GST)
I/We am/are willing to carry out work at_____% Above or ____%Below the
estimated cost mentioned above. The amount of my/our tender works out as under
Estimated cost put up to tender:- Rs. 953561.18 Add____% Above,
Rs. OR Deduct % Below:-Rs.
NOTE:- (1) The Quoted Rate shall be inclusive of all taxes.