Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹1.5 Cr+₹4.5 L (3.14%)Rejected-Finance | ₹1.5 Cr+₹4.5 L (3.14%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹1.5 Cr+₹4.6 L (3.24%)Rejected-Finance PO KETEKIBARI DISTT SONITPUR TEZPUR ASSAM 784001 | SONITPUR | ASSAM | 784001 | ₹1.5 Cr+₹4.6 L (3.24%) | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | L4₹1.5 Cr+₹4.7 L (3.29%)Rejected-Finance OLD HASIMARA DISTT JALPAIGURI WEST BENGAL PIN 735215 | HASIMARA | JALPAIGURI | WEST BENGAL | 735215 | ₹1.5 Cr+₹4.7 L (3.29%) | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 5 | L5₹1.5 Cr+₹5.2 L (3.64%)Rejected-Finance SITANI BUILDING DINBAZAR JALPAIGURI 735101 | JALPAIGURI | JALPAIGURI | WEST BENGAL | 735101 | ₹1.5 Cr+₹5.2 L (3.64%) | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
28 Jul 2021, 6:00 pmClosed
CWE BINNAGURI
HQ CWE Binnaguri
SPL REPAIR RENOVATION OF CLASS ROOMS AND TOILET AND INTERNAL EXTERNAL ELECTRIFICATION OF VIDYALAYA BUILDING UNDER GE (S) BINNAGURI
2021_MES_449225_1
8010/BIN(S)/04 OF 2021-22
Open Tender
Civil Works
Item Rate
120 days
Binnaguri Military Station
As per Tender Documents
8 documents required · 8 mandatory
₹1,000
GE SOUTH BINNAGURI
₹2.1 L
Yes
23 Aug 2021
7 Jun 2021
29 Jul 2021
7 Jun 2021
28 Jul 2021
23 Jul 2021
Amount
Schedule 'A'
Taking down cement plaster on wall of any description incl racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 10mm thick in CM 1:4 on fascia, roof projection, chajja etc finished even & smooth w/o using extra cement complete all as specified and as directed. Note:- Water proofing treatment shall be paid and measured separately.
M&L for Rendering 15mm thick in CM (1:6) on concrete/brick wall surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for 5mm thick plaster rendering on fair faces of concrete surfaces as in ceiling in CM(1:3) finished even and smooth (without using extra cement) complete all as specified and as directed.
M&L for 20mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm and 10 mm thick) mixed with water proofing compound in top layer @3% by the weight of cement or as per manufacturer's instructions finishing the surface even and smooth without using extra cement complete all as specified and as directed. Note : Integral water proofing compound shall be measured and paid separately.
Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed
M&L for 3 coat of white wash on ceiling of newly plastered surfaces incl preparation of surfaces etc complete all as specified and as directed.
M&L for two coats of oil emulsion distemper on walls over a coat of alkali resistant primer over two coats of cement based wall care putty each of 1mm thick on newly plastered surfaces of wall incl preparation of surfaces etc complete all as specified and as directed.
M&L for on new plastered surfaces of wall and applying a coat of exterior damp proof wall care putty and two coats of anti fungal exterior emulsion paint over a coat of damp proof primer complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles, and rubbish off the premises complete all as specified and as directed.
M&L for 15mm thick screed bed or bedding layer in CM (1:6) as in floor complete all as specified and as directed.
M&L Rendering 10mm thick in cement mortor in 1:4 on fair face of brick work in dado and skirting finish fare & even to receive tiles etc complete all as specified and as directed.
M&L for non skid ceramic tiles digital glossy of size 400x400x7mm thick in floor etc set & jointed in neat cement slurry & pointed in colored cement to match with the tiles complete all as specified and as directed.
S&F for glazed digital ceramic colored/printed tiles size 450x300 not less than 7 mm thick as in vertical surfaces such as skirting dados & repairs to step etc. complete all as specified and as directed.
M&L 20mm thk Jet black Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, WHB top cooking platforms and like in 12 mm thk cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including chamfering full rounding to the exposed surface complete all as specified and as directed.
Taking down steel window/ventilator of any description and any position including guard bar complete all as specified and as directed.
S&F in repair powder coated aluminium window sliding type three track (one gauge and two glazed shutter) aluminium sections weighing not less than 0.55 Kg per mtr for shutter including necessary jointing cleats, glazing cleats, rubber packing, screws, handle, locking arrangement etc complete and 5.5 mm thick tinted glass with 75% non visibility and stainless steel mosquito proof gauge of 0.36 mm dia of wire and 1.40 mm aperture size complete all as specified and as directed.
S&F in repair decorative/fancy type curtain rod 25 mm dia MS powder coated with fixing brackets, stops, rollers etc all approved by Engr- in Charge complete as specified and as directed.
S&F in repair powder coated aluminum anodized louvered ventilators of size 600 x 600 mm with glass louvers , without sash bars, of aluminium sections weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings and 5.5mm thick tinted glass fixed in panels with suitable locking arrangements incl taking down old complete all as specified and directed.
S&F Mild steel framed work such as grills, gratings, guard bar etc with ends of bars shouldered or riveted or for forged into spikes framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290. Gde -E- 165 complete all as specified and as directed.
M&L for preparation of new or previously untreated steel surfaces any description over 10 Cm in width or girth not otherwise described and applying two coats of synthetic enamel paint complete all as specified and as directed.
Taking down PVC/AC soil pipe including fittings as in wall of any dia complete all as specified and as directed.
S&F 110mm dia PVC SWR pipes pressure rating 6 kgf/cm2single socketed in any length with rubber ring joints, fixed to wall complete all as specified and as directed.
Ditto all as per item above but for 50 mm complete all as specified and as directed.
S&F 110mm dia PVC bends of any radius with access door fixed in cement concrete (1:2:4), type B1 complete all as specified and as directed.
S&F in repair 100mm dia PVC floor trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4), type B1 complete all as specified and as directed.
S & F 50mm PVC (SWR) bends of any radius complete all as specified and as directed.
M&L for PCC 1:3:6 type C-2 (40mm graded aggregate) as in surface channels or drains complete all as specified and as directed.
M&L Extra for forming fair finishing to drains or channel of 30 cm inner girth in cement concrete with using extra cement including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed.
M&L for 75mm thick PCC (1:3:6) type C-1 with using 20mm graded stone aggregates as in plinth protection/footpaths, finishing the concrete surfaces even and smooth without using extra cement, all complete as specified and as directed.
Taking up or down GI or CPVC 15mm bore pipe and connection including cleaning for refixing or removal from site complete all as specified and as directed.
Taking up or down GI or CPVC 20mm steel tubing and connections incl cleaning for refixing or removal to store complete all as specified and as directed.
S&F of 15 mm CPVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc, any type of pipe complete all as specified and as directed.
S&F of 20 mm CPVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and as directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. complete all as specified and as directed.
S & F in repair 15mm size PVC Connection with PTMT nut of length 450mm complete all as specified and as directed.
Supply & fixed in repair, Vitreous china wash basin, white flat back, size 550 x 400 mm excl taps, waste chain and plug and porcelain stopper incl brackets, waste pipe & CP waste coupling complete all as specified and as directed.
S&F in repair, vitreous china wash basin, white oval type or cascade type and of size 550 x 445 x 200mm depth / height excl taps, incl brackets, waste pipe & CP waste coupling complete all as specified and as directed.
S & F shelf of PTMT fixed with and incl chromium plated brass screws and wooden/plastic cleats (Min weight 300gms) complete all as specified and as directed.
Supply & fixed in repair, Pillar taps, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without letter Hot or Cold with long screwed shanks and fly nuts screwed for 15 mm dia bore of pipe complete all as specified and as directed.
S&F in repairs Bib taps fancy type chromium plated for 15mm bore pipe, screwed down for iron pipes or for brass ferrule all complete as specified and as directed.
S&F in repairs 2 in 1 bib taps fancy type chromium plated for 15mm bore pipe, screwed down for iron pipes or for brass ferrule complete all as specified and as directed.
Supply & fixed in repairs angular CP Stop valve (ISI Marked), cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15 mm bore and fixed in repair complete all as specified and as directed.
S&F in repair 15mm bore chromium plated shower roses with arm (size of arm 195mm long with bend to 45 degree) complete all as specified and as directed.
S&F in repairs fancy type Chromium plated with long shank and cup (concealed type) stop valve cost copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe 15mm bore complete all as specified and as directed.
Supply & fixed in repair, Vitreous china wash down water closet pan (Pedestal pattern) white (excl fixing bolts, flushing cistern and flush pipe) but including plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel CP or aluminised hinging device complete all as specified and as directed.
S&F for mild steel chromium plated health faucet (ABS body) suitable for 15mm dia pipe with 1.25 M long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed.
S&F in repair CP Jet spray with 1.0 mtr tube complete all as specified and as directed.
S&F in repair vitreous china squatting pan Orissa pattern size 580x440 mm white with integral foot rest complete incl provision of lime concrete bedding complete all as specified and as directed.
Supply & fixed in repair, Vitreous china bowl urinal, size of 465 x 355 x 265 mm white (minimum) with grating and union for discharge pipe (excl flushing cistern, flush pipe and waste pipe) complete all as specified and as directed.
S&F in repair 10 ltr capacity PVC flushing cistern low level white colour incl PVC connection PVC flush pipe of reqd length CI brackets in lieu of old unserviceable push button flushing Cistern complete all as specified and as directed.
S&F in repair brass chromium plated tubular towel rail, 20mm dia, D type, 60 cm long between flanges chromium plated complete all as specified and as directed.
Supply & fixed in repairs Soap dish/tray, Stainless steel, fixed to plugs with CP brass screws complete all as specified and as directed.
Supply & fixed in repairs PVC waste pipe with union, flexible suitable for wash hand basin or urinal, 32 mm dia complete all as specified and as directed.
M& L for opening of blockage in pipe line from out let of water tank/manholes to all internal pipes fittings to smooth flow of water from toilet/cook house/Drinking point/Stop valves complete by Air pressure/ water gravity pressure etc. Complete all as specified & directed.
Taking down chowkat or frame n.exc 1.5 sqm each with shutters (without taking off shutters from the frames). complete all as specified and as directed.
M&L PCC 1:3:6 type C1 using 20m graded agg as in bed block or for embeding of holdfast as specified and directed. complete all as specified and as directed.
S&F for solid PVC door frame of size 50 X 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube, supplied and fixed in repair in opening as per specifications and drawing complete as directed.
S&F for factory made solid panel PVC door shutters 30mm thick (style) consisting of frame made out of MS tube for top and bottom rail, MS frame shall be covered with heat moulded plain coloured PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail & bottom rail; Panelling of plain colur PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement. Door to be fixed with frame with 3 nos stainless steel butt hinges of size 100mm x 25mm x 2 mm and 50mm long steel screws drilled suitable to pass through both the walls of the MS tube etc complete as per specification and drawings and direction by engr in Charge. complete all as specified and as directed.
M&L for Aluminium alloy anodised handle fabricated 150mm long . complete all as specified and as directed.
M&L for Aluminium alloy anodised barrel tower bolts 150 mm long. complete all as specified and as directed.
Demolition of RCC any thickness and any size as in columns, roof slab, chajja, facia and beam etc complete all as specified and as directed.
M&L for RCC type B1 (1:2:4) in beams, cantilevers, bressumers, lintels, chajjas,covers etc complete all as specified.
M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, binding spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) n. less than 0.9mm dia. complete all as specified and as directed.
M&L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams for flat rough finished surface etc. complete all as specified and as directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc., separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 M and disposal of unserviceable materials, debris and rubbish to outside MD land all specified and as directed by the Engineer in Charge. complete all as specified and as directed.
M&L brickwork with sub class B bricks straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 by using old size bricks. complete all as specified and as directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick wall built in CM 1:6 as directed. complete all as specified and as directed.
M&L for Excavation in trenches n.exc. 1.5 M wide and n.exc. 1.5 m in depth for foundation etc in soft/loose soil. complete all as specified and as directed.
M&L for Returning, filling in including spreading, leveling, watering & well ramming in layers not exc. 25 cm. complete all as specified and as directed.
M&L for Removing excavated material exc. 250 m but n.exc. 500 mt & depositing where directed. complete all as specified and as directed.
Cutting and demolition of SWG sewer pipe in damaged portion alongwith concrete bedding including removing from site as directed and S&F new salt glazed stone ware drain pipes, grade ‘A’ placed in position in old sewer line and jointed in cement mortar (1:1) including packing under and haunching against the sides of the new pipes with PCC (1:3:6) type C-2 with using 40 mm graded stone aggregates for the following dia (Internal) of sewer pipe lines:- complete all as specified and as directed. (a) 100 mm dia pipes.
(b) 150 mm dia pipes
M&L in repair Factory made RCPC drain/MH cover of size 900 mm x 450 mm x 50 mm thk of capacity 2MT complete all as specified and as directed.
Chipping of existing plaster manually from masonry or concrete surface using chisel and hammer and disposal of debris outside MOD land complete all as specified and directed. (Upto 4 storey bldg). complete all as specified and as directed.
Chipping of unsound /week concrete materials from slabs , beams, columns ,lintel,chajja, fin , fascia etc. by any means as directed by engr-in-charge including tapering all edges, making square shoulders of cavities air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting incl foreign materials , loose concrete/aggregate etc and disposal of all debris outside MOD land complete in all respect all as specified and directed.(Upto 4 storey bldg) (a) 30mm average thickness for slabs
(b) 50mm average thickness for beams
(c) 60mm average for columns
(d) Deduct/add for every less/extra 10mm
Removing of concrete all around reinforcement including from behind the reinforcing bars to give an average 25mm (but not less than clear air gap)by manual methods (hammering the bar using wire brushing ,chiselling etc) and applying alkaline rust removing chemical followed by removing rust including from behind the reinforcing bars by emery paper and cleaning the area thoroughly by water and allow it to drywall as complete all as specified and as directed. (a) Upto 12mm dia of bar
(b) Above 12mm dia of bar
M & L for providing single coat of epoxy bond adhesive of prepared non metallic surface (existing surface) and applying by brush all as per manufactures instruction/specification and complete all as specified and as directed. (Upto 4th Storey Bldg)
S & A of Epoxy Zinc rich primer on the prepared steel surfaces by brush the primer shall have a minimium specific gravity 1.75 minimum weight film thickness/coat 40 microns and minimum adhesive bond strength with steel is 1.5N/mm2 complete all as specified and directed. (Upto 4th Storey Bldg)
M & L for introducing new reinforcement bars for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameter in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling ,fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy anchoring Hilti RE 500 cartridge or Equivalent etc complete all as specified and as directed.upto 4 storey height. (a) Upto 12mm dia of bar
(b) Above 12mm dia of bar
M & L for providing and inserting mild steel shear key bars/levelling gauges of required length and diameter in reinforced/plain concrete as per drawing and direction of engr-in-charge including power drilling holes of appropriate diameters to a minimum depth equal to 12 times the diameters of shear key bar/levelling gauge, cleaning the drilled holes of loose dust by blowing , insertion of epoxy from cartridge, placing the share key bar in position and allowing it to stay undisturbed for 24 hours. Rate shall bed include cost of labour, all materials, T&P for power drilling in concrete , epoxy cartridge, plastic nozzle etc, complete incl cleaning the drilled holes of loose dust by blowing air complete all as specified and directed.(Upto 4th Story Bldg). (a) 12mm dia, 300mm long @ MS shear key of Bar NOTE :- The projection length of shear key shall be more than 10 times its diameter plus half of the thickness of cover concrete plus bend length.
M & L for providing and placing in position free flow non shrink cementations micro concrete of Grade of M-50 to the effected beam, column etc . The micro concrete shall have a minimum 1 day compressive strength of 10 Mpa and 28 days strength of 50 Mpa, minium tensile strength 5N/mm2 @ 28 days, minimium flextural strength 5N/mm2 @ 28days and complete all as specified and directed. (a) 60mm average thickness of column
(b) 50mm average thickness of beam
(c) Add or deduct for every 10 mm thick
Supply, mixing and application two component structural grade polymer modified reinstatement mortar, where local spalling has taken place or shuttering is not possible . The morter can be applying in layers not exceeding 6mm thick in each layer in and upto any thickness in smaller vertical pockets and upto any thickness in horizontal applications. The mortar should have a minimium compressive strength 12N/mm2 in 1 day and 45N/mm2 in 28 days. Minimum flexural strength should be 8 N/mm2 in 28 days. A modified styrene butadience emulsion for use as a bonding aid and gauging liquid for cementious system to be mixed with cement slurry before the application of mortar to be used @ 6 ltr/bag of cement. The bonding agent should have minimium compressive strength 24N/mm2. Minimum tensile strength 3.5N/mm2, minimium flexural strength 6.5N/mm2 complete all as specified and directed. (Upto 4th story Bldg). NOTE:- Cement and sand morter in proportion of 1:2 graded coarse sand ) with polymer admixed in proportions approved by Engr-in-charge). complete all as specified and as directed. (a) Upto 25mm average thickness
M & L for applying curing compound of approved brand over concrete surfaces as per manufactures instruction complete all as specified and directed. (Upto 4th story bldg)
Demolition of un-reinforced Cement Concrete of any description and in any position not otherwise specifically provided for and disposal of unserviceable materials, debris and rubbish outside MD Land complete all as specified and as directed.
M&L for Pressure grouting at construction joints and honeycomb areas with cement grout Plasticised expanding grout admixture all as per manufacturers instructions and complete all as specified and as directed. Cebex 100 at 225 gram/bag of cement. (Approx three hole per Sqm) Note : The above treatment will be done in presence of company authorised person and also company skilled workers.
M& L for Providing and fixing 6-8mm dia nozzle along the joints / construction Joint after proper surface preparation and injection of Epoxy resin free-flow grout through the nozzle till the refusal of the grouting materials and confirming to the requirements of BS EN 1504-3 Class R4 and BS EN 1504-6 . complete all as specified and as directed. Note : The above treatment will be done in presence of company authorised person and also company skilled workers.
M&L for 50 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate ) as in sunken floor /in floorings including levelling the surface with proper slope towards spout pipe finishing the surface even and smooth using extra cement including WPC 3 % all as specified and directed.
M&L for 10 mm thick plaster of cement mortar (1:3) rendering on fair faces of brick work/ concrete surfaces mixed with water proofing compound in top layer @3% by the weight of cement or as per manufacturer's instructions finishing the surface even and smooth without using extra cement complete all as specified and as directed. Note : Integral water proofing compund shall be measured and paid separtely.
M& L for water proofing treatment to sunken floors with the following treatment /Specification (a) First layer of slurry of cement at the rate of 0.488 Kg/Sq.M mixed with acrylic based polymer, modified cemetitious composite compound at the rates of 0.253 Kg/Sq.M . This layer will be allowed to cure for 4 hrs . (b). Second layer of slurry of cement at the rate of 0.242 Kg/ Sq.M cementitious composite compound at the arte of 0.126 Kg/Sq.M . This layer will be allowed to air cure for 4 hrs followed with water curing 48 hrs .(c) The rate includes preparation of surface , treatment and sealing of all joints, corners, junctions, of pipe and masonry with polymer mixed slurry. (d) . This treatment shall be provided after provision of cement plaster mixed with WPC as above. (e). 200 microns thick polythelene film passed with the help of adhesive shall be provided over above treatment. complete all as specified and as directed.
Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete and in sunken floors all as specified and directed.
25 mm thick PCC 1:2:4 type B0 (Using 12.5 mm graded stone aggregate) as in floors finished to receive tiles complete all as specified and as directed. .
Supply & fix Vitreous china urinal partition white colour of size 310 x 700 mm complete all as specified and as directed.
S&F in repair Couple Closet,Bowl with cistern for coupled WC white, of size 375x650x800mm with S trap 250mm with PP Soft close seat cover, hinges,fixing accessories,cistern fittings and accessories set of complete all as specified and as directed
Cutting holes into or through brick walls n.ex 150 Sq.cm built in cement mortar or lime mortaror stone walls built in lime mortar or walls of lime concrete and making good in cement mortar 1:3 or cement concrte 1:2:4 type B1 as required etc complete all as specified and as directed.
Cutting opening in cement concrete walls/ beams/slabs of any desription upto a depth of 25 cm of any girth into concrete and trimming the surface as required, as required etc complete all as specified and as directed. .
M&L RCC type B1 (1:2:4) using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and the like . complete all as specified and as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; exc. 200m thick (Horizontal or sloping) Rough finished surfaces of concrete flat. complete all as specified and as directed.
Mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips. complete all as specified and as directed.
M&L for two coats of oil emulsion distemper on walls over a coat of alkali resistant primer over two coats of cement based wall care putty on old plastered surfaces of wall incl complete removal of existing treatmant etc complete all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles, and rubbish off the premises complete all as specified and as directed.
M&L for Glazed Vitrified tiles Matte finished/ Antiskid scratch free tiles 8 to 9 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors, of any approved shades or in two colours etc set and jointed in neat cement slurry and pointed in white or coloured cement to match. complete all as specified and as directed.
S&F for glazed ceramic coloured/printed tiles size 300 x 450 x 7 mm thick as in vertical surfaces such as skirting dados & repairs to step etc. complete all as specified and as directed.
M & L Machine cut Mirror Polished kota stone slab in flooring 18 to 20 mm thick of size 595 x 595 mm over 20mm thick cement screed base in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete all as specified and as directed.
M&L for Machine cut Mirror Polished kota stone slab 18-20mm thick in riser or steps, skirting, dado and pillar laid over 10 mm thick screed bed cement screed (1:4) and jointed with grey cement slurry mixed with pigment to match the shade fo the slab including rubbing and polishing complete all as specified and as directed.
M & L for Jet Black Granite 18 to 20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of stone in floorings, steps etc including cutting and polishing of tiles complete. complete all as specified and as directed.
M & L for Jet Black Granite 18 to 20 mm thick machine cut in skirting/ dado etc laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of stone including cutting and polishing of tiles complete. complete all as specified and as directed.
M&L for Double Nosing and stepping stone 15 mm thick of colour as approved (Johnson or Equivalent) as in treads of staircase set and Jointed in neat cement slurry over and including 15 mm thick screed bed in CM (1:4) complete all as specified and as directed. .
M&L applying rust removing chemical to hinges of steel window shutter n.exc 1sqm each, removing all rusts/scaling, dirt etc from the hinges by wire brushing incl necessary welding, replacement of hinges if required for making the shutter operational and finally greasing hinge joints for smooth functioning of steel window shutter complete all as specified and as directed by EIC
M&L for provision of horizontal/vertical style by welding to the existing steel window/shutter/frame for making the shutter operational and finally greasing hinge joints for smooth functioning of steel window shutter complete all as specified and as directed by EIC
S&F in repair steel window with side hung shutters including projecting type hinges with steel handle and steel peg stay,complete with glazing bars,dovetailed or welded confirming to IS 1038 complete as specified and as directed.
S&F in repair steel window with side hung shutters including projecting type hinges with steel handle and steel peg stay,complete without glazing bars, dovetailed or welded confirming to IS 1038 complete as specified and as directed.
S&F in repairs peg stay steel windows and steel ventilators , 300mm long, made of 3mm thick mild steel with copper oxidized finish with suitable size GI nuts, bolts and washers for fixing peg stay all complete as specified and as directed.
S&F in repairs bow handle for steel windows and steel ventilators 100mm long made of 3mm thick mild steel with copper oxidised finish with locking plate, cleat etc as required including suitable size GI nuts , bolts and washers for fixing handle all complete as specified and as directed.
Repairs to steel window projecting type/box type hinges with supply & fixing required new components such as rebates steel pin required sizes including washers welded with steel frames for left or right side shutter complete all as specified and as directed.
S&F stainless steel wire cloth 0.36 nominal dia wire & average width of aperature 1.40 mm complete all as specified and as directed.
S & F in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete complete all as specified and directed
M&L for 3 coat of white wash on old plastered surfaces incl preparation of surfaces etc complete all as specified and as directed.
M&L for Glazed Vitrified tiles Matt finished/ Antiskid scratch free tiles 8 to 9 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in dado/ skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match.
M&L 18 to 20mm th Jet black Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, WHB top cooking platforms and like in 12 mm thk cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including chamfering full rounding to the exposed surface complete all as specified.
M & L for 18 to 20 mm thick Udaypur Green marble slab as in flooring laid over 20mm thick cement screed base in CM (1:6) and jointed with white cement slurry mixed with suitable pigment to match the shade of the slab incl rubbing and polishing complete all as specified and as directed.
Taking down copper / aluminium point wiring (light, fan socket or power) complete, including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed
M&L for point wiring complete with 1.5 sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marded) with proper colour coding drawn through and including non-metallic rigid PVC medium tgrade conduit not less than 20mm dia dn conduit accessories (ISI marked) concealed in wall / fixed to roof, ceiling etc including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sundin terminal box made out of GI sheet steel not less than 1.22mm thick for boxesupto a size of 200x300mm and above this size not less than 1.63mm thick duly painted with aluminium inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite / plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall / floor and matching with existing specification connections of cable with MCBs or bus bar shall be sone through proper size copper / brass thimbles where concealing of conduit is not feasible ie on surface of roof etc conduit shall be fixed on surface with necessary saddles at no extra cost complete all as specified and as directed for the following :- (a) One light point controlled by one w2ay switch 5/6 amps
(b) One ceiling fan / exhaust fan point controlled by one way switch 5/6 amps
(c) One socket out let 5/6 amps point on the same board
(d) One socket out let 5/6 point on the independent board
(e) One bell / buzzer point controlled by one bell push button
(f) One light point controlled by two way switch 5/6 amps
M&L for point wiring complete for one socket outlet 15 amps point on independent board with 2.5 sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medkum grade conduit not less than 20mm dia dnd conduit accessories (ISI marked) concealed in wall / fixed to roof, ceiling etc including provision of 2.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sunken terminal box made out of GI sheet steel not less than 1.22mm thick for boxes upto a size of 200x300mm and above this size not less than 1.63mm thick duly painted with aluminium inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite / plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall / floor and matching with existing specifications connections of cable with MCBs or bus bar shall be done through proper size copper / brass thimbles complete all as specified and as directed.
S&F in repair socket 2 in 1, 5 Pin, 5/6 amps, 230 volts AC (ISI marked) white ivory finish flash type complete all as specified and as directed.
S&F in repair socket outlet 2 in 1, 5/15 amp multipurpose 230 volt flush type complete all as specified and as directed by Engineer-in-Charge
S&F in repair switch piano flush type 5/6 single pole one way complete all as specified and as directed.
S&F in repair bell / buzzer push 5/6 amps flush type white / ivory finish complete all as specified and as directed.
S&F in repair switch piano type 2 way 5/6 amp, 230 volt, flush button single pole one way complete all as specified and as directed by Engineer-in-Charge
S&F in repair switch piano flush type 15/16 amps single pole one way complete all as specified and as directed
S&F in repair call bell ding dong type AC single pole 220/240 volts, surface type complete all as specified and as directed
S&F in repair ceiling rose, PVC / polycarbonate, isolated body, three terminals, complete all as specified and as directed.
M&L in repair lamp holder, insulated PVC / polycarbonate body, with back plate suitable for batten / angle fittings complete all as specified and as directed.
S&F in repair deluxe fan electronic regulator AC 50 Hz, 100 watt, rotary step type, white / ivory finish complete all as specified and as directed.
S&F IP 20 class, I LED light 1x18 W (or nearest next higher wattage) (4 feet), 5700K, wall / surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency >95 lumens / watt power factor >0.90, operating range - 140 to 270V, 50 Hz fixed with 02 Nos of PVC round / square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified and as directed.
S&F bulk head luminaire suitable for 10 watt LED (or nearest next higher wattage) light IP66 grade, luminaire efficiency not less than 120 lumems / watts with and including 10 watt LED (or nearest next higher wattage) lamp and connecting up with and including PVC insulated 3 core of size 0.75 sqmm copper conductor from ceiling rose to terminal block of light fitting including necessary taking down the old unserviceable fitting complete all as specified aqnd as directed.
Supply and fixing LED post tops luminiares 15 watt made in cast aluminium with decorative diffuser with IP 65 protection including all accessories internally prewired including taking down the old u/s one complete all as specified and as directed
S&F IP 20, class I, LED mirror light fitting 1x10 W (or nearrest next higher wattage) 5700 K, wall / surface mounted with aluminium housing 2 feet long, integrated type with high efficiency PMMA difuser, integrated high efficiency electronic driver & surge suppessor of 2 KV or more, luminaire efficacey > 95 lumens / watt, power factor >/00.90, operating range - 140 to 270V, 50Hz fixed with 02 Nos of PVC round / square blocks, scrwes etc complete including 01 No 10 W LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size including necessary taking down the old unserviceable fitting complete all as specified and as directed.
M&L for concealed sub-main wiring alongwith earth wire of size of 2x6.0 sqmm + 1x6.0sqmm earth wire ISI marked FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of size not less than 25mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete including taking down old unsv aluminium submain wiring complete all as specified and as directed. Note : Two runs of 6 sqmm conductor for main and one run of 6 sqmm condutor as earth wire with propper colour coding including one run of PVC conduit shall be measured as one unit length connections of cable wit MCBs or bus bar shall be done through appropriate size brass / copper thimbles.
M&L fir cibceaked sub-main wiring alongwith earth wire of size of 2x4.0sqmm + 1x4.0sqmm earth wire, ISI marked FRLS, PVC insulated, multi stranded, copper donductor, single core cable drawn through and including PVC rigidconduit (medium grade of size not less than 25mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete including taking down old unsv aluminium submain wiring all complete all as specified and as directed. Note : Two runs of 6sqmm conductor for main and one run of 6 sqmm conductor as earth wire with proper colour coding including one run of PVC conduit shall be measured as one unit length connections of cabgloe wit MCBs or bus bar shall be done through appropriate size brass / copper thimbles.
S&F sheet metal enclosure for 4 way distribution boards (DBs), IP-43 double, tripple pole & neutral with 200 amps rated bus bar, IP-20 protection including four pole MCCB 63 amps with blanking plates complete all as specified and as directed.
S&F MCB distribution boards (DBs) with sheet metal enclosure, double door, IP-43 protection 240 volts, 8way, single pole and neutral, with 100 amps rated copper bus bar (as per OEM), neutral link, earth link earthing studs, suitable for fixing MCBs without MCBs fixed flush to wall / other surface complete all as specified and as directed.
S&F MCB triple pole and neutral 40 amps, 415V, 10 KA complete all as specified and as directed
S&F MCB single pole and neutral 40 amps, 240 volts, 'C' curve, 10KA complete all as specified and as directed.
S&F MCB single pole, 5 to 32 amps, 240 volts, 'C' curve, 10KA complete all as specified and as directed.
S&F heavy duty exhaust fan 300mm sweep MS body with antidust painting 4 blade with heavy duty mortor and double ball bearing 1320 RPM single phase 230 / 240 volts copper wounds air delivery 1600 CMH complete with all accessories as bird guard / louvers shutters etc incl making connections with 3 core flexible multistranded copper conductor of size 0.75 sqmm run through flexible pipe complete all as specified and as directed including cutting holes and making good the distrubed surfaces of walls in CM(1:4) and finishing the surface as per existing colour scheme.
Taking out ceiling fan 1200mm sweep from its position and refixing other B/R plaster work complete all as specified and as directed.
M&L for earthing with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to depth not less than 2.25m below the ground level with top edge of earth plate at a depth not less than 1.55m below the ground level connected to galvanized iron wire 4mm dia earth lead by means of bolts & nuts, check nuts & washers made of galvanised steel earth strip protected by and including PCC (1:2:4) type B1 precast RCC cover slab (M-15) reinforced with 8mm dia TMT bars 100mm centre to centre bothways including one handle made of 10mm dia round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc complete all as shown in EP No 3 of SSR Part-I 2009 and testing on completion complete including dismantling the existing unserviceable earthing complete all as specified and as directed.
Supply installation, testing and commissioning of electric water heater, storage vertical type BEE 5 star rated, 25 ltr capacity 230 volts AC, 50 Hz comprising of high wattage heating element for instant heating,l extra thic SS inner tank of superior 304 grade, rust & shock proof ABS outer body, non-ferrous pressure plate with & including provision of 04 Nos grouting bolts suitably flushed to wall or any other surface including electric connection with 3 core PVC insulated, sheathed, stranded copper conductor cable / flexible chord complete all as specified and as directed.
M&L for GI water tubing medium grade 15mm dia fixed on wall with all fittings and fixtures complete all as specified and as directed.
S&F or angle stop valve with wall flange, chromium plated, screwed down (CP) of size 15mm fancy type complete all as specified and as directed.
M&L 15mm bore bib taps, cast copper alloy chromium plated, fancy type, screwed down, screwed for iron pipe or for brass gerrule and fixed complete all as specified and as directed.
S&F of hot and cold water connection including connection pipe complete with all necessary items complete all as specified and as directed.
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 16 sqmm 4 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule 'A'). NOTE : Specification of cable shall be as under:- (a) Inner sheathing shall be of extruded PVC. (b) Cable shall also be supplied with sequences hall marking at every metre on the luner sheathing. (c) Ultra violet radiation resistance compounded comprising to ASRM-2863 flame netarded as per EIV specification. (d) Anti rodent and antitermite compound added. (e) PVC compounds of various grades as IS-5831. (f) Compaction conductors shall be shaped and arrangement to the same will be on the cable.
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 25 sqmm 4 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule 'A'). NOTE : Specification of cable shall be as under:- (a) Inner sheathing shall be of extruded PVC. (b) Cable shall also be supplied with sequences hall marking at every metre on the luner sheathing. (c) Ultra violet radiation resistance compounded comprising to ASRM-2863 flame netarded as per EIV specification. (d) Anti rodent and antitermite compound added. (e) PVC compounds of various grades as IS-5831. (f) Compaction conductors shall be shaped and arrangement to the same will be on the cable.
M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and as directed by Engr-in-Charge (Punned thickness 18cm shall be considered for payment as per para 19.75 of SSR Part-I)
Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class 'B' old size brick and flat and width wise along the axis of the trench complete all as specified and as directed by Engr-in-Charge
Supply and fixing 40mm dia GI tubing medium grade ISI marked laid in trenches / laid under floor for protection of cable including all fittings such as elbow, bends, etc and short length complete all as specified and as directed.
Fabric, supply errect, connect, test and commission LT electrical Distribution Pillar Box, AC 415 volts, 3 phase, 4 wire, 50 Hz out door type, industrial cubical factory fabricated, with 3mm thick MS sheet, top with slopping canopy, weather proof, dust and vermin proof over all size suitable for and including housing following switchgear / items, bottom with channel supports, front with hinged type doors and locking arrangement, bottom with detachable sheets with holes for cable glands, separate chamber for bus bars, cable entry and exit, complete panel board inside and outside epoxy powder coated finish and mounted on PCC pillars with bolts grouted with PCC (1:3:6) type C-2 as in foundation including necessary excavation, earth work and connecting all incomers and out goings MCCB and comprising aluminium bus bars 4 x 600 Amps capacity mounted on suitable insulator supports, a incommer MCCB 250 Amps 4 pole, 415 volts, 50 Hz, 1 No out going MCCB TP 100 Amps, 25 KA-04 Nos phase indicator (RYB) with control switch, digital type multifunction meter to read volts, Amps frequency etc with suitable CTs etc-01 No and one aluminium earth strip of size 25x3mm complete all as specified and as directed
CHAKRABORTY AND SONS
VARNI BUILDERS
DEEP NIRMAN
M.P. SITANI AND SONS
MAA BHAGWATI ASSOCIATES
M/S R. K. INDUSTRIES
M/s KASHMIRA SINGH BARMI AND SONS
M/S JANATA CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .