Karnataka Industrial Areas Development Board
Assistant Executive Engineer-Ele
Part-A- Establishing 2x150 MVA, 2x31.5 MVA, 220/66/11kV Sub-station at Adinarayana Hosahalli Phase-II Industrial area at Doddaballapura Taluk, Bengaluru Rural District, Part-B- Running of 220kV DC 1200Sqmm XLPE Copper UG cable from 220/66kV Doddaballapura (NRS) station to proposed 220kV Cable Terminating Tower near Adinarayana Hosahalli phase-2 I/A Entry point for distance of 5.435 Kms., Part-C- Construction of 220kV Transmission line using DC & MC design based Monopoles from I/A Entry point (Proposed 220kV CTT) and from proposed 400/220kV Adinarayana Hosahalli I.A. S/s to proposed 220/66/11kV Adinarayana Hosahalli Phase-2 KIADB S/s for a distance of 4.053 Kms using AAAC Moose Conductor, Part-D- Construction of 2 numbers of 220kV outdoor GIS terminal bays at existing 220/66kV NRS Doddaballapura station, Part-E- Construction of 2 numbers of 220kV indoor GIS terminal bays at proposed 400/220kV Adinarayana Hosahalli station, Part-F- 66kV LILO Arrangement of existing 66kV NRS Doddaballapura - Vijayapura SC line to proposed 220/66/11kV Adinarayana Hosahalli Phase - 2 KIADB sub-station under Self execution basis by KIADB
KIADB/2025-26/SS/WORK_INDENT352
KIADB/2025-26/SS/WORK_INDENT352
Open
Sub-Station
Two Tender Document System(Two Cover)
KIADB Head Office Bangalore
15 documents required · 15 mandatory
To qualify for award of this contract, each Tenderer in his name should have in the last five years period 2020-21 to 2024-25. (a) The Tenderer (Single Entity) should have satisfactorily completed (at least 90% of the contract value), as prime contractor, at least one similar nature such as Construction and Commissioning of One Substation of minimum 220kV class along with 220kV Transmission line (Over Head / UG Cable) work of value not less than Rs.150.87 Crores (exclusive of GST) within last five financial years. (b) For Consortium: (i) The lead bidder should have satisfactorily completed (at least 90% of the contract value), as prime contractor, at least one similar nature such as Construction and Commissioning of One Substation of minimum 220kV class along with 220kV Transmission line (Over Head/UG Cable) work of value not less than 51% which is Rs.77.00 Crores (exclusive of GST) within last five financial years. (ii) The Consortium Partner should have satisfactorily completed (at least 90% of the contract value), as prime contractor, at least one similar nature such as Construction and Commissioning of One Substation of minimum 220kV class along with 220kV Transmission line (Over Head/UG Cable) work of value not less than 25% which is Rs.37.75 Crores (exclusive of GST) within last five financial years. (iii) The lead bidder and consortium partner put together shall meet not less than Rs150.87 Crores (exclusive of GST)
To qualify for award of this contract, each Tenderer in his name should have in the last five years period 2020-21 to 2024-25 (a) The Tenderer (Single Entity) should have completed minimum route length 3.24 Km Over head transmission line using minimum 66kV Voltage class Monopoles. (b) for Consortium: The lead bidder and the Consortium Partner put together should have completed minimum route length of 3.24 km with a condition as below (i) The lead bidder should have completed minimum route length of 51% which is 1.65 Km Over head transmission line using minimum 66kV Voltage class Monopoles. (ii) The Consortium Partner should have completed minimum route length of 25% which is 0.81 Km Over head transmission line using minimum 66kV Voltage class Monopoles
To qualify for award of this contract, each Tenderer in his name should have in the last five years period 2020-21 to 2024-25 (a) The Tenderer (Single Entity) should have completed minimum Circuit length of 4.35 Km using UG cable of minimum 66kV Voltage Class of minimum 1Cx1000 sqmm size. (b)(i) for Consortium: The lead bidder and the Consortium Partner put together should have completed minimum circuit length of 4.35km using UG cable of minimum 66kV Voltage Class of minimum 1Cx1000 sqmm size with a condition as below: (ii) The lead bidder should have completed minimum Circuit length of 51% which is 2.81 Km using UG cable of minimum 66kV Voltage Class of minimum 1Cx1000 sqmm size. (iii) The Consortium Partner should have satisfactorily completed minimum Circuit length of 25% which is 1.08 Km using UG cable of minimum 66kV Voltage Class of minimum1Cx1000 sqmm size
Executed in any one financial year, the following minimum quantities of work (80% quantity of work put to tender): Certificates of proof shall be enclosed from competent Authority not below the rank of Executive Engineer in Government/ Public Sectors/ Government Undertaking Organizations. (1) Providing 220/66kV, 150MVA or above capacity Power Transformer: 2 Nos., (2) Providing 66/11kV, 31.5MVA or above capacity Power Transformer: 2 Nos., (3) Providing 220kV Circuit Breakers: 6 Nos., (4) Providing 66kV Circuit Breakers: 6 Nos., (5) Providing 220kV Control & Relay Panel/ Bus Coupler Panel/ Bus Bar Protection panel: 6 Nos., (6) Providing 66kV Control & Relay Panel/ Bus Coupler Panel/ Bus Bar Protection panel: 4 Nos., (7) Providing Substation Automation System for 220/66/11kV Station: 1 No, (8) Providing 11kV MCVCB Switchgear (2IC PLUS 16F PLUS 4CB PLUS 1AP PLUS 1BC): 1 No, (9) Providing 11kV 95/240/400/1000sqmm HTUG cable: 2.704 Km, (10) Construction of Control Room Building for 220 kV station: 1 No, (11) Construction of overhead transmission line using minimum 66kV voltage class Monopoles (Route length): 3.242 Km, (12) Supply and laying of minimum1Cx1000 sqmm size UG cable of minimum 66kV Voltage Class: 29.60 Km. For Single Entity: The Tenderer (Single Entity) should have satisfactorily completed 100% of the individual quantities as in serial No. 1 to 12. For Consortium: The lead bidder should have satisfactorily completed minimum 51% of the individual quantities as in serial No. 1 to 12 and the Consortium Partner should have satisfactorily completed minimum 25% of the individual quantities as in serial No. 1 to 12 and both put together shall meet 100% of the individual quantities.
Each Tenderer should further demonstrate: Availability by owning at least 50% of the required / specified critical equipment for this work and remaining 50% can be deployed on lease / hire basis the following key and critical equipment for this work (i) For Single Entity: Availability by owning at least 50% of the required / specified critical equipment for this work and remaining 50% can be deployed on lease / hire basis the following key and critical equipment for this work (ii) The lead bidder/Consortium partner or cumulatively should demonstrate Availability by owning at least 50% of the required / specified critical equipment for this work and remaining 50% can be deployed on lease / hire basis the following key and critical equipment for this work
Personal capabilities: (i) For single entity:- The Tenderer / bidder should demonstrate the availability of key personals by uploading their relevant documents. (ii) For consortium: The lead bidder/Consortium partner or cumulatively should demonstrate the availability of key personals by uploading their relevant documents
a) Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under: Assessed available tender capacity: (AxNx1.5-B) Where, A: Maximum value of Substation/Electrical engineering works executed in any one year during the last five years (updated to 2025-26 price level) taking into account the completed as well as works in progress. N: Number of years prescribed for completion of the works for which tenders are invited. B: Value, at 2025-26 price level, of existing commitments and on-going works to be completed during the next 24 months. (b) Single entity has to meet the 100% of assessed bid capacity and in case of consortium, the lead member /bidder shall meet 65% of the assessed bid capacity & the consortium partner shall meet 35% of the assessed bid capacity and put together shall meet 100% of criteria.
To qualify for award of this contract, each Tenderer in his name should have in the last five years period 2020-21 to 2024-25. Achieved in at least two financial years a minimum financial turnover of Rs.301.75 Crores. (From Electrical Contract Works Only) The Tenderer (Single Entity) has to meet the 100% which is Rs 301.75 Crores of financial qualification criteria and in case of consortium, financial requirement prescribed shall be met by prime member / lead member minimum 51% which is Rs.154.00 Crores & other partner shall meet minimum 25% which is Rs.75.50 Crores of qualification criteria and put together shall meet 100% which is Rs.301.75 Crores of criteria
For Single Entity: liquid assets and /or availability of credit facilities for the work of Part-A: Establishing 2x150 MVA, 2x31.5 MVA, 220/66/11kV Sub-station at Adinarayana Hosahalli Phase-II Industrial area at Doddaballapura Taluk, Bengaluru Rural District, Part-B: Running of 220kV DC 1200Sqmm XLPE Copper UG cable from 220/66kV Doddaballapura (NRS) station to proposed 220kV Cable Terminating Tower near Adinarayana Hosahalli phase-2 I/A Entry point for distance of 5.435 Kms., Part-C: Construction of 220kV Transmission line using DC & MC design based Monopoles from Entry point (Proposed 220kV CTT) and from proposed 400/220kV Adinarayana Hosahalli I.A. S/s to proposed 220/66/11kV Adinarayana Hosahalli Phase-2 KIADB S/s for a distance of 4.053 Kms using AAAC Moose Conductor, Part-D: Construction of 2 numbers of 220kV outdoor GIS terminal bays at existing 220/66kV NRS Doddaballapura station, Part-E: Construction of 2 numbers of 220kV indoor GIS terminal bays at proposed 400/220kV Adinarayana Hosahalli station, Part-F: 66kV LILO Arrangement of existing 66kV NRS Doddaballapura - Vijayapura SC line to proposed 220/66/11kV Adinarayana Hosahalli Phase - 2 KIADB sub-station under Self execution basis by KIADB in favour of CEO & EM, KIADB, Bengaluru not less than Rs.45.50 Crores (Credit lines/ letter of credit/ certificates from banks for permitting the fund requirement etc - equivalent of the estimated cash flow for the months in the peak construction period) For Consortium: (i) For lead Partner: liquid assets and /or availability of credit facilities for the work of Part-A: Establishing 2x150 MVA, 2x31.5 MVA, 220/66/11kV Sub-station at Adinarayana Hosahalli Phase-II Industrial area at Doddaballapura Taluk, Bengaluru Rural District, Part-B: Running of 220kV DC 1200Sqmm XLPE Copper UG cable from 220/66kV Doddaballapura (NRS) station to proposed 220kV Cable Terminating Tower near Adinarayana Hosahalli phase-2 I/A Entry point for distance of 5.435 Kms., Part-C: Construction of 220kV Transmission line using DC & MC design based Monopoles from Entry point (Proposed 220kV CTT) and from proposed 400/220kV Adinarayana Hosahalli I.A. S/s to proposed 220/66/11kV Adinarayana Hosahalli Phase-2 KIADB S/s for a distance of 4.053 Kms using AAAC Moose Conductor, Part-D: Construction of 2 numbers of 220kV outdoor GIS terminal bays at existing 220/66kV NRS Doddaballapura station, Part-E: Construction of 2 numbers of 220kV indoor GIS terminal bays at proposed 400/220kV Adinarayana Hosahalli station, Part-F: 66kV LILO Arrangement of existing 66kV NRS Doddaballapura - Vijayapura SC line to proposed 220/66/11kV Adinarayana Hosahalli Phase - 2 KIADB sub-station under Self execution basis by KIADB in favour of CEO & EM, KIADB, Bengaluru not less than Rs.23.50 Crores (Credit lines/ letter of credit/ certificates from banks for permitting the fund requirement etc - equivalent of the estimated cash flow for the months in the peak construction period. (ii) For consortium Partner: liquid assets and /or availability of credit facilities for the work of Part-A: Establishing 2x150 MVA, 2x31.5 MVA, 220/66/11kV Sub-station at Adinarayana Hosahalli Phase-II Industrial area at Doddaballapura Taluk, Bengaluru Rural District, Part-B: Running of 220kV DC 1200Sqmm XLPE Copper UG cable from 220/66kV Doddaballapura (NRS) station to proposed 220kV Cable Terminating Tower near Adinarayana Hosahalli phase-2 I/A Entry point for distance of 5.435 Kms., Part-C: Construction of 220kV Transmission line using DC & MC design based Monopoles from Entry point (Proposed 220kV CTT) and from proposed 400/220kV Adinarayana Hosahalli I.A. S/s to proposed 220/66/11kV Adinarayana Hosahalli Phase-2 KIADB S/s for a distance of 4.053 Kms using AAAC Moose Conductor, Part-D: Construction of 2 numbers of 220kV outdoor GIS terminal bays at existing 220/66kV NRS Doddaballapura station, Part-E: Construction of 2 numbers of 220kV indoor GIS terminal bays at proposed 400/220kV Adinarayana Hosahalli station, Part-F: 66kV LILO Arrangement of existing 66kV NRS Doddaballapura - Vijayapura SC line to proposed 220/66/11kV Adinarayana Hosahalli Phase - 2 KIADB sub-station under Self execution basis by KIADB in favour of CEO & EM, KIADB, Bengaluru not less than Rs.11.50 Crores (Credit lines/ letter of credit/ certificates from banks for permitting the fund requirement etc - equivalent of the estimated cash flow for the months in the peak construction period. (iii) The lead bidder and consortium partner put together shall meet not less than Rs.45.50 Crores.
₹7,500
₹3.0 Cr
16 Nov 2025
16 Nov 2025
22 Dec 2025
25 Nov 2025
25 Nov 2025
Establishing 2x150 MVA, 2x31.5 MVA, 220/66/11kV Sub-station at Adinarayana Hosahalli Phase-II Industrial area at Doddaballapura Taluk, Bengaluru Rural District
Part-A: Supply Portion
a)POWER TRANSFORMERS: 3Ph, 50Hz, Core Type, 3 winding star/star/delta, Vector Group: YNyn0d11, OLTC, bushing CT for tertiary of ratio 1000/1A, 5P20, 15VA, ONAN/ONAF/OFAF with Fa...
b). POWER TRANSFORMERS: 3Ph, 50Hz, Core Type, 2 winding Delta / Star, Vector Group: Dyn11, OLTC, ONAN/ONAF with Fan control cubicle Numerical RTCC Panel, Oil etc., complete erminal connector suitable ...
SF-6 CIRCUIT BREAKER: SF-6 Circuit Breaker with rigid bi-metallic terminal connector suitable for single/double Drake ACSR with spring / semi-pneumatic / pneumatic type operating mechanism and with mo...
SF-6 CIRCUIT BREAKER: SF-6 Circuit Breaker with rigid bi-metallic terminal connector suitable for single/double Drake ACSR with spring / semi-pneumatic / pneumatic type operating mechanism and with mo...
ISOLATORS: Isolators and Terminal connectors as per Technical specification including solid core cylindrical post insulators:
220kV class Isolators:
220kV, electrically cum manually operated double b...
ISOLATORS: Isolators and Terminal connectors as per Technical specification including solid core cylindrical post insulators:
220kV class Isolators:
220kV, electrically cum manually operated double b...
ISOLATORS: Isolators and Terminal connectors as per Technical specification including solid core cylindrical post insulators:
220kV class Isolators:
220kV, electrically cum manually operated double b...
c) Under hung mounting type without earth switch (13000 mm Mounting Height) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
1) 220kV, 1250A, 50kA:(For Trf. & PT Bays) a. Upright without earth Switch with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Live Point Height 5750mm with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b. Under hung without earth switch (13000 mm Mounting Height) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
3) 220kV, 3000A, 50kA:(For I/C Bay) - LPH: 8250mm with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
66kV class Isolators: 66 kV, double break electrically cum manually operated isolators with solid core insulator, terminal connector suitable for 63mm Al. tube/Moose ACSR/Twin Moose ACSR conductor, ma...
66kV class Isolators: 66 kV, double break electrically cum manually operated isolators with solid core insulator, terminal connector suitable for 63mm Al. tube/Moose ACSR/Twin Moose ACSR conductor, ma...
66kV class Isolators: 66 kV, double break electrically cum manually operated isolators with solid core insulator, terminal connector suitable for 63mm Al. tube/Moose ACSR/Twin Moose ACSR conductor, ma...
66kV class Isolators: 66 kV, double break electrically cum manually operated isolators with solid core insulator, terminal connector suitable for 63mm Al. tube/Moose ACSR/Twin Moose ACSR conductor, ma...
66kV, 2000A, 40kA:(For 150MVA Tr. & B/C bay with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Upright without earth Switch Live Point Height 635...
66kV, 2000A, 40kA:(For 150MVA Tr. & B/C bay with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Upright without earth Switch Live Point Height 460...
66kV, 2000A, 40kA:(For 150MVA Tr. & B/C bay with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Under hung without earth switch
66kV, 3000A, 40kA:(For I/C Bay) - LPH: 6350mm with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
a) Rigid type Terminal connector suita...
CURRENT TRANSFORMERS: Oil filled Current Transformers with rigid terminal connector suitable for Drake ACSR/Al tube with all lead and lifts complete as per specifications and directions of engineer in...
CURRENT TRANSFORMERS: Oil filled Current Transformers with rigid terminal connector suitable for Drake ACSR/Al tube with all lead and lifts complete as per specifications and directions of engineer in...
CURRENT TRANSFORMERS: Oil filled Current Transformers with rigid terminal connector suitable for Drake ACSR/Al tube with all lead and lifts complete as per specifications and directions of engineer in...
CURRENT TRANSFORMERS: Oil filled Current Transformers with rigid terminal connector suitable for Drake ACSR/Al tube with all lead and lifts complete as per specifications and directions of engineer in...
CURRENT TRANSFORMERS: Oil filled Current Transformers with rigid terminal connector suitable for Drake ACSR/Al tube with all lead and lifts complete as per specifications and directions of engineer in...
CURRENT TRANSFORMERS: Oil filled Current Transformers with rigid terminal connector suitable for Drake ACSR/Al tube with all lead and lifts complete as per specifications and directions of engineer in...
Voltage Transformer - Single Phase, oil filled outdoor type as per Technical Specification: with terminal connector suitable for Drake ACSR/Al tube with all lead and lifts complete as per specificatio...
Voltage Transformer - Single Phase, oil filled outdoor type as per Technical Specification: with terminal connector suitable for Drake ACSR/Al tube with all lead and lifts complete as per specificatio...
Capacitor Voltage Transformers - 245 kV CVT, 4400 PF, 1 Ph CVT with 2 secondaries, terminal connector suitable for Twin Moose ACSR conductor with marshalling box etc., complete as per technical specif...
Surge Arresters with terminal connectors suitable for Drake ACSR with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Note: Surge Arresters are wi...
Surge Arresters with terminal connectors suitable for Drake ACSR with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Note: Surge Arresters are wi...
Wave Trap: 0.5mH, 2000A, 50kA Pedestal type, along with terminal connector suitable for Twin Moose ACSR conductor with all lead and lifts complete as per specifications and directions of engineer in c...
Relay & Protection Panels with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 220 kV Line -Type 2L
Relay & Protection Panels with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 220/66/11KV Transformer-Type 2T6
Relay & Protection Panels with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 220KV Bus Coupler - Type 2BC
Relay & Protection Panels with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 220KV Bus Bar Protection - Type 2BBA
Relay & Protection Panels with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 66KV Line- Type 6L
Relay & Protection Panels with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 66KV Bus Coupler- Type 6BC
Relay & Protection Panels with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 66/11KV Transformer- Type 6TI
Relay & Protection Panels with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 11kV line- Type 11L(Provision for 2 feeders to be made in one panel ...
II) Substation Automation System
(As per Annexure-SAS of Relay & Protection Panels and Sub-station Automation specification)
Complete Sub-station automation system including hardware and software ...
Station Structure :
(Rates of Fabrication, galvanising, supply of Mild steel tower materials is considered) 220KV Side Station Structure with all lead and lifts complete as per specifications and dir...
Station Structure :
(Rates of Fabrication, galvanising, supply of Mild steel tower materials is considered) 220KV Side Station Structure with all lead and lifts complete as per specifications and dir...
Station Structure :
(Rates of Fabrication, galvanising, supply of Mild steel tower materials is considered) 220KV Side Station Structure with all lead and lifts complete as per specifications and dir...
Station Structure :
(Rates of Fabrication, galvanising, supply of Mild steel tower materials is considered) 220KV Side Station Structure with all lead and lifts complete as per specifications and dir...
Station Structure :
(Rates of Fabrication, galvanising, supply of Mild steel tower materials is considered) 66KV Side Station Structure with all lead and lifts complete as per specifications and direc...
Station Structure :
(Rates of Fabrication, galvanising, supply of Mild steel tower materials is considered) 66KV Side Station Structure with all lead and lifts complete as per specifications and direc...
Station Structure :
(Rates of Fabrication, galvanising, supply of Mild steel tower materials is considered) 66KV Side Station Structure with all lead and lifts complete as per specifications and direc...
Station Structure :
(Rates of Fabrication, galvanising, supply of Mild steel tower materials is considered) 66KV Side Station Structure with all lead and lifts complete as per specifications and dire...
Station Structure :
(Rates of Fabrication, galvanising, supply of Mild steel tower materials is considered) 66KV Side Station Structure with all lead and lifts complete as per specifications and direc...
Lighting mast (2.678 MT+5% for Bolt & Nuts) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
MOUNTING STRUCTURES:
(a) 220KV Isolators
(ai) Live Point Height 8250mm with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
aii) Live Point Height 5750mm with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) 66KV Isolators
(bi) Live Point Height 6350mm with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
bii) Live Point Height 4600mm with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
ii) Current Transformers:
a) For 220KV CTs & NCTs with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) For 66KV CTs & NCTs and 11kV NCTs with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
iii) Voltage Transformers:
a) For 220KV VTs/CVTs with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) For 66KV VTs with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
iv) Surge arrestor
a) For 198kv LAs with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) For 60KV LAs with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
220kV: 0.5mH with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
vi) For Post Insulator of Rigid Bus
a) For 220KV Side with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) For 66KV Side with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
vii) For High Post Insulators for Transformers
a) For 150MVA, Transformer
220KV side - 6 Nos.
66KV side - 6 Nos. (Bolted Type Foundation)
b) 66/11KV Transformer - 6 Nos. with all lead and lifts c...
viii) 11kV Cable support structure for 1CX1000sqmm cable (11kV side of 31.5MVA transformer) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
ix) 11kV Cable support structure for 3Cx400sqmm cable (for capacitor bank ) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
x) 66kV, 1000sqmm cable termination structure with LA mounting with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
RIGID BUS WITH TAPS & CLAMPS:
Aluminium Tube Conforming to 6340 WP of IS-5082/1969 (BS1600-Sch.40) of following sizes with all lead and lifts complete as per specifications and directions of engineer...
RIGID BUS WITH TAPS & CLAMPS:
Aluminium Tube Conforming to 6340 WP of IS-5082/1969 (BS1600-Sch.40) of following sizes with all lead and lifts complete as per specifications and directions of engineer...
RIGID BUS WITH TAPS & CLAMPS:
Aluminium Tube Conforming to 6340 WP of IS-5082/1969 (BS1600-Sch.40) of following sizes with all lead and lifts complete as per specifications and directions of engineer...
RIGID BUS WITH TAPS & CLAMPS:
Aluminium Tube Conforming to 6340 WP of IS-5082/1969 (BS1600-Sch.40) of following sizes with all lead and lifts complete as per specifications and directions of engineer...
Inverted ‘V’ taps made of 63mm Aluminium Tube (BS-1600) of 2500mm vertical height for vertical portion and cross bus on 220KV Side with rounded off end with all lead and lifts complete as per spec...
Straight taps made of 63mm Aluminium Tube (BS-1600) of 1250mm vertical height for vertical portion and cross bus on 66kV side with rounded off end with all lead and lifts complete as per specification...
Straight taps made of 100mm Aluminium Tube (BS-1600) of 1250mm vertical height for vertical portion and cross bus on 66kV side with rounded off end with all lead and lifts complete as per specificatio...
Post Insulator Clamp suitable for 100mm Aluminum pipe and post Insulators Solid Core Type with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Post Insulator Clamp suitable for 100mm Aluminum pipe and post Insulators Solid Core Type with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Post Insulator Clamp suitable for 63mm Aluminium Pipe and post insulators solid core type with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 66KV...
Post Insulator Clamp suitable for 63mm Aluminium Pipe and post insulators solid core type with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 66KV...
Post Insulator Clamp suitable for 63mm Aluminium Pipe and post insulators solid core type with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 66KV...
Corona Bell Suitable for Aluminium Pipe of Size 100mm on 220KV Side with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Corona Bell Suitable for Aluminium Pipe of Size 100mm on 66KV Side with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
End cap suitable for Aluminum pipe of size with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 63mm on 220kV side
End cap suitable for Aluminum pipe of size with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 63mm on 66kV side
Moose ACSR Conductor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Insulators : Post Insulators - Cylindrical Solid Core Insulators as per IS:5350, Part-II & III
a) For 220KV Side-2 Units / Stack with all lead and lifts complete as per specifications and direction...
ii. High level Post Insulators for 150MVA Tr., with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b)For 66KV Side-1 Unit/Stack with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
i. Post Insulators of Rigid Bus
ii. Post Insulators (for 150MVA Tr.-6 Nos. 31.5MVA Tr. 6 Nos). with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Disc Insulators String. :
11KV, 120KN Disc Insulator :
[a] 220KV Side:
[ai] Tension String : String of 16 Units (For Trf Bays) with all lead and lifts complete as per specifications and directions...
aii] Double Tension string : String of 16 Units (For Line, B/C) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) 66KV Side: bi) Double Tension String : 2 String of 6 Units each for 150MVA Tr & 66 KV BC with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
bii] Polymer type double tension string( for 150MVA, 220/66kV Tr.bay over 150MVA Tr) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
biii)Tension String : String of 6 Units with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
11KV 90KN Disc Insulator:220KV side suspension string - string of 14 units with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
66KV side suspension string - string of 6 units with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Insulator Hardware & Clamps:
Bolted type Double Tension clamp to suit Moose ACSR
(a) 220KV Side - Transformer bays with all lead and lifts complete as per specifications and directions of engineer in...
b)66KV Side - 31.5MVA Transformer bays and Line bays with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Bolted type Double Tension clamp to suit twin Moose ACSR
a) 220KV side - Line & BC bay with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) 66KV side 150MVA Transformer & BC bays with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Bolted type suspension clamp to suit Moose ACSR
(a) 220KV Side - Transformer bay with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) 66KV Side - 31.5MVA Transformer bays & Line bays with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Bolted type suspension clamp to suit Double Moose ACSR
a). 220KV side - Line & BC Bays with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b). 66KV side of 150MVA Transformer & BC Bay with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
C’ Type Wedge connector suitable for Moose to Moose ACSR:
(a) 220KV Side - Transformer bays with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) 66KV Side - 66/11kV Transformer & 66kV Line bays with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
c) C’ Type Wedge connector suitable for Double Moose to Double Moose - 220KV side - Line bays & BC bays with all lead and lifts complete as per specifications and directions of engineer in charge of...
d)C’ Type wedge connector suitable for Double Moose to double Moose on 66KV side of 150MVA transformer + 66kV Bus coupler with all lead and lifts complete as per specifications and directions of eng...
e) C’ Type Wedge Connector suitable for Drake/Twin Zebra to Twin Moose ACSR conductor (for 220kV line) with all lead and lifts complete as per specifications and directions of engineer in charge of ...
f) C’ Type Wedge connector suitable for Coyote/Panther/Drake to Moose ACSR 66kV side (line bays) with all lead and lifts complete as per specifications and directions of engineer in charge of the wo...
g) C’ Type wedge connector suitable for Twin Moose to Single Moose (for 66kV side of 150MVA Trf) with all lead and lifts complete as per specifications and directions of engineer in charge of the wo...
PI Clamp suitable for post insulator & Moose ACSR (for 220kV Side of 150MVA Trf) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
PI Clamp suitable for post insulator & Moose ACSR (for 66kV Side ( of 31.5MVA Transformer) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
PI clamp suitable for post insulator and Twin Moose ACSR- ( for 66kV side of 150MVA Transformer) with all lead and lifts complete as per specifications and directions of engineer in charge of the work...
T-connector suitable for 63mm Al. tube and Twin Moose ACSR (For 220kV line bays) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
T-connector suitable for 63mm Al. tube and Twin Moose ACSR (For 66kV side of 150MVA Transformer) with all lead and lifts complete as per specifications and directions of engineer in charge of the work...
Spacers for Twin Moose ACSR 66kV side (Rigid/Flexible) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Spacers for Twin Moose ACSR 220kV side (Rigid/Flexible) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Auxiliary Transformers with oil, cable termination type on both HT & LT, outdoor type: with off load tap changer in steps of 2.5% with all lead and lifts complete as per specifications and directions ...
LTAC panel (indoor):
415V, LTAC panel (2 I/C ACB 800A+2 O/G SFU, 200A + 8 O/G SFU 100A+14 O/G SFU, 63A+12 O/G SFU, 32A+1B/C SFU, 800A+1DG Change over switch 300A etc. with all lead and lifts comp...
a) Power Cable from Auxiliary Transformers to LTAC panel:
1.1 kV PVC Insulated 240 Sqmm Al.cable 3.5 core with glands /lugs/Ferrules with all lead and lifts complete as per specifications and directio...
b) PVC insulated aluminium power cable (AC supply for lighting etc):
70 Sq.mm 3.5 Core, with glands / lugs / ferrules with all lead and lifts complete as per specifications and directions of engineer ...
AC Distribution Box (outdoor):i. AC Distribution Box Double front type, 24 terminals, 1200 x 1350 x 600mm, 2I/C of 100A, MCCB 20KA + 24 O/G MCB 16A+20/G of 100A, HRC fuse with all lead and lifts compl...
ii. AC Distribution Box Single front Type, 6 terminals, 750 x 1350 x 300mm, 1 I/C of 100A, MCCB 20KA+6 0/G MCB 16A + 1 O/G of 100A, HRC Fuse with all lead and lifts complete as per specifications and ...
DG set, 3 Phase , 50Hz, 415V, 0.8 PF-58.5 KVA DG set(Rate for 62.5Kva considered) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Station Battery & Battery charger:2x220V, 300AH Battery Set consisting of 110 No. Cells per bank with float (2 Nos.) & boost (2 Nos.) type battery charger including control panels, change over arrange...
PVC Insulated Copper Control Cable with lugs / ferrules (Refer annexure for details at the end of this schedule of quantities) with all lead and lifts complete as per specifications and...
b)2.5 Sq.mm 14 Core with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
c)2.5 Sq.mm 10 Core with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
d)2.5 Sq.mm 4 Core with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
e) 2.5 Sq.mm 7 Core with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
f) 6 Sq.mm 4 Core with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
g) 16 Sq.mm 4 Core with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
h) 4 Sq.mm 4 Core with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
i) 70 sq.mm 2 Core with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
j) 1PX0.5 sq mm Screened cable with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
11KV Switchgear: 31.5kA, 2600A for incomer and 1250A for feeders (2IC+1BC+16F+4CB+1AP)-DAS compatible as per Technical specification. Annunciator panel shall be simplex panel instead of desk type ment...
11KV UG Cable with the required cable terminations:
[a] 11KV XLPE 95 Sq.mm Aluminium Cable-3 Core (for two auxiliary transformers from the 11KV Switchgear) with all lead and lifts complete as per spe...
b)11KV XLPE Cable, 1000 Sq.mm Aluminium Cable - 3x4 runs of IC x 1000 Sq.mm cable from 66/11KV Transformers to 11KV Switchgear with all lead and lifts complete as per specifications and directions o...
c) 11kV XLPE 400Sq.mm Aluminium Cable - 3 Core to be run from 11kV Switchgear to 11kV take off DP Structure & 11kV Capacitor bank with all lead and lifts complete as per specifications and directions...
11kV Cable Termination Kit suitable for following sizes as per Technical Specification.
a)400 Sq.mm 3 Core For Capacitor bank - Indoor with all lead and lifts complete as per specifications and direc...
b)400 Sq.mm 3 Core For Capacitor bank - Outdoor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
c)95 Sq.mm 3 Core - Indoor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
d)95 Sq.mm 3 Core - Outdoor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
1000 Sq.mm Single Core - Indoor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
1000 Sq.mm Single Core - Outdoor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
400Sq.mm 3 core for Feeder - Indoor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
400Sq.mm 3 core for Feeder - Outdoor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
NOTE: The bidder shall quote unit rates for power cable,...
Fire Fighting Equipments with necessary mounting Stands:
Mechanical Foam Extinguisher Type:
50 Litres with all lead and lifts complete as per specifications and directions of engineer in charge of th...
Mechanical Foam Extinguisher Type:
9.0 Litres with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Water Type (Gas Pressure Type)- 9.0 Liters with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Carbon Dioxide Type 4.5 Kgs with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
G.I. Bucket 9 Liters with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Steel Stands with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Nitrogen Injection fire extinguishing system including Civil Engineering works like soak pit etc., as per the recommendations of the supplier of the fire fighting system.2 set for 150MVA power transfo...
Nitrogen Injection fire extinguishing system including Civil Engineering works like soak pit etc., as per the recommendations of the supplier of the fire fighting system.(2 set for 31.5MVA power trans...
STATION & YARD LIGHTING (OUTDOOR) (To be designed, assessed & quoted by the bidder)
a)Supplying and erection of street lighting lattice type structure along with GI pipe for fixing of LED lamp (0.182...
b)Supply and installation/ Fixing/ Provision o f Outdoortype Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shockproof, IP65 (WeatherProof), rustproof, dustproof, waterpr...
c)PVC Insulated Copper Control Cables : 1.1 KV PVC insulated Copper Control Cable with glands/Lugs/ Ferrules etc with all lead and lifts complete as per specifications and directions of engineer in ch...
d) Supply of LED Street light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded p...
12.1kV, 5.8 MVAR Capacitor bank with series reactor, NCT, LA etc as per specification along with mounting structure with all lead and lifts complete as per specifications and directions of engineer in...
11KV Isolator & DP Structure with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
(a) 11KV Double Break isolator 400A, 25KA
b) 11KV RCC DP structure for mounting Isolator & LA with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
c) 11kV DB Isolator, 400A, 25kA with lattice type mounting structure (for 11kV capacitor bank) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
d) 11kV DB Isolator, 400A,25kA with LA(for Auxilliary transformer) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
e) 11kV RCC DP structure for mounting 11kV DB Isolator for Auxilliary transformer with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Maintenance Tools and Plant:
a)Earth Resistance Tester with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) Portable (Mobile) Oil Pump (1/2 HP Air Pump 500 to 1000 Gallans) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
c)Telescopic Ladder Aluminium : 6 m height with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
d) Ring spanners : 12 nos. per set with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
e) Tube Spanners : 12 nos. per set with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
f) Pipe wrench : 24 inches size with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
g) Pipe wrench : 18 inches size with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
h) Hydraulic crimping tool upto 1000 Sq mm with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
i)Hydraulic shearing machine with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
j) Threading die set for pipe threading with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
k) Welding machine (arc welding) 10KVA with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
l) Heavy duty drilling machine with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
m)Rubber hand gloves : 15 kV tested with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
n)Five and three celled torch with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
o) Insulated cutting pliers : 12 inches size with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Insulated cutting pliers : 8 inches size with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
p) Line live tester with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
q) Screw driver 18 inch with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
r) Screw driver 12 inch with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
s) Hammer 8 Ibs with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
t) Hammer 2 Ibs with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
u) Chain pulley block 5 ton with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
v) Hydraulic Jack 5 ton with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
w)Pipe derrick with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
x) Allen Keys with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
y)Box spanners : 12 nos. per set with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
z)Transil Oil Dielectric Breakdown testkit with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
aa)Insulation Tester Digital type (Megger) : 2.5 kV - 5 kV with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
bb) Insulation Megger 500V with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
cc) SF-6 Gas leak detector with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
dd) Multi-meter Electromechanical with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
ee)Multimeter electronic type with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
ff)Hydrometer with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
gg) Hydrometer syringe suitable for vent holes with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
hh) Specific gravity correction chart with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
ii) Wall mounting type holder for hydrometer & thermometer (teak wood make) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
jj) Cell testing voltmeter (3-0-3v) Conforming to IS-1248 with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
kk)Rubber appron with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
ll)Pipette with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
mm)Protective Goggle with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
nn)Acid resisting jars (4 pint capacity) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
oo)Rubber shoes knee height with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
pp)Glass funnel with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Other T& P Equipments
a) Double end spanner : 12 nos. per set with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) Rain coat with duck back with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
c) Gum Boots with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
d) Hickery rods with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
e) Grounding sticks with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
f) Manila Rope 1" with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
g) Manila Rope 3/4" with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
h) Files of various sizes with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
i) Portable Drilling Machine with Stand heavy duty
j) Hand Drilling Machine with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
k) Safety Belts with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
l) Safety Helmet with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
m) Steel Measuring tape 30Mtrs with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
n) Steel Measuring tape 15Mtrs with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
MISCELLANEOUS ITEMS:
Rubber mats 1000 mm x 2000 mm x 12 mm size suitable for 1.1 kV class with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
First aid box with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Shock treatment charts, hard board, liminated with coloured pictures & literature both in Kannada & English with all lead and lifts complete as per specifications and directions of engineer in charge ...
Water filter / Water purifier : Wall mounting type (Aqua-guard type) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Sub-station name board duly painted as per specification including erection & Civil Works with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Fixograph of size 1.5m x 2.5m with English / Kannada alphabets with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Door locks 7 levers (Navtal make) (Sizes and capacities to be got approved) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Danger board ( prohibited ) with support structure including fixing in front of the gate with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Equipments name plates and earthing name plates including fixing at outdoor yard with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Furniture for Control Room Staff and Maintenance Staff
Steel Almirahs 6.5 Feet with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Steel Almirahs 6.5 Feet with glass panel doors with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Officer’s tables with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Steel Slotted Angle Rack (Big Size) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Steel Slotted Angle Rack (Small Size) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Steel Dust Bins with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Executive revolving chairs with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
S type arm chairs with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Steel folding chairs with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
SCADA and Communication Equipments:
Communication equipment
a)SDH Equipment : (STM-16 MADM, upto 3 MSP 1+1 protected directions) with 60 G Higher Order as well
as Lower Order - Base Equipment (comm...
Transceiver Type
S16.1 SFP-3 MSP -1 no at Magadi & 1 no at Bheemanakuppe with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Tributary Interface
a) E1 Interface card (Min. 16 interfaces per card) - 3 MSP with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) Ethernet interface 10/100Mbps with Layer-2 switching (Min 2x1Gbps+4x100/10Mbps ports) without SFP-3 MSP with all lead and lifts complete as per specifications and directions of engineer in charge ...
c) 1x1000 base SFP (Gigabit Ethernet Interfaces 10/100Mbps with Layer- 2 switching) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
d) Cabinet Equipment to house SDH Equipment + Optical cards + Tributary Cards, Drop/Insert MUX Equipments and DACS Equipment with all lead and lifts complete as per specifications and directions of en...
e) Router for change over between OFC & VSAT communication for SCADA Data with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
f) 220V DC to 48V DC Converter for SDH Equipment with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
g) IP phone with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
h) Digital protection coupler with 8 command version (Direct fiber intype) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
i) 48V Battery Charger suitable for 200AH Battery set with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
j) 48V, 200AH Battery Set with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
k) 48V DCDB independent change over between DC
source 1 and 2 with 20 feeders with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Note: Rate of D...
Mandatory spares
Power Transformer ( 220/66/11kV):
Oil collecting bottle with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Terminal Connector clamps- suitable for 245kV bushing to suit single Drake ACSR with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Terminal Connector clamps- suitable for 66kV bushing to suit double Drake ACSR with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
a. Drain valve (100mm to 200mm size) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b. Top/ bottom filter valve (50mm to 100mm size) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
c. Top/ middle/ bottom oil sampling valve with plug (15 to 25mm) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
d. Header pipe valve with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
e. Gate/ Butterfly valves of various sizes ranging from 50mm to 200mm with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
MOG with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Prismatic gauge with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Starters, contactors, relays with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Pressure Relief Device (PRD or PRV) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Oil surge relay with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Bucholtz relay with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Tap position Indicator with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Fixed & moving contacts for diverter switch with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Fixed & moving contacts for selector switch 220kV & above class with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
WTI with 4 contacts, 15mtrs capillary length with built in CCU RTD & external remote indicator, range
0-150degC with SCADA/ SAS compatibilty with all lead and lifts complete as per specifications and...
OTI with 2 contacts, 15mtrs capillary length with built in CCU RTD & external remote indicator, range 0-150 deg C with SCADA/ SAS compatibilty with all lead and lifts complete as per specifications an...
PT 100 sensor alongwith probe of suitable length with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Copper Contact fingers male & female (set complete for one Isolator) - for 220kV class with all lead and lifts complete as per specifications and directions of engineer in charge of the wor...
Copper Contact fingers male & female (set complete for one Isolator) - for 66kV class with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Terminal pad (set complete for one Isolator) - for 220kV class with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Terminal pad (set complete for one Isolator) - for 66kV class with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Terminal conector (set complete for one Isolator) - 220kV class with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Terminal connector (set complete for one Isolator) - 66kV class with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Circuit Breaker (CB)
1) Closing coil with resistor
a) for 220kV CB with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) for 66kV CB with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
2) Tripping coil with resistor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
a) for 220kV CB
b) for 66kV CB with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
3) Terminal Pad
(For one Complete Circuit Breaker):
a) for 220kV CB with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) for 66kV CB with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
4) Terminal connector
(For one Complete Circuit Breaker):
a) for 220kV CB with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) for 66kV CB with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
SF6 gas cylinders filled with SF6 gas suitable for 1 no of CB(220kV CB,110kV & 66kV CB) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Relay Panel Spares
All Type of Numerical Relays (1No. each type) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Tripcircuit supervision relay(2Nos) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Self reset trip relay [1No. each type] with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Hand reset trip relay[1No. each type] with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Timer relay [1No. each type] with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
DC supervision relays with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Flag relays [1No. each type] with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Auxillary relays [1No. each type] with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Maintenance & Testing equipment:
Capacitance & Tan delta & oil resistivity measuring equipment (Approved Vendor) with all lead and lifts complete as per specifications and directions of engineer in c...
Portable dissolved gas analyser with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Moisture measuring kit - KARL FISCHER type(Approved Vendor) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
SF6 gas filling adaptor kit with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Measuring & analyzing equipment for moisture & air content (Approved Vendor) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Micro ohm meter (1.0 micro-ohm to 199.99micro ohm) (Approved Vendor) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Numerical relay testing kit (Approved Vendor) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
BDV test kit (Digital) (Approved Vendor) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Circuit Breaker operational analyzer-DCRM (Approved Vendor) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Digital DC insulation tester-5kV (Approved Vendor) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Online DC earth fault locator with built-in charger & rechargeable batteries (Approved Vendor) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Combined CT & VT analyzer (Approved Vendor) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Mandatory spares for Sub-Station Automation system:
Bay control unit with configuration software with all lead and lifts complete as per specifications and directions of engineer in charge of the work...
Switch of each type with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Optical cable of longest length with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
ERECTION PORTION:
a) POWER TRANSFORMERS: 3Ph, 50Hz, Core Type, 3 winding star/star/delta, Vector Group: YNyn0d11, OLTC, bushing CT for tertiary of ratio 1000/1A, 5P20, 15VA, ONAN/ONAF/OFAF with Fan c...
b). POWER TRANSFORMERS: 3Ph, 50Hz, Core Type, 2 winding Delta / Star, Vector Group: Dyn11, OLTC, ONAN/ONAF with Fan control cubicle Numerical RTCC Panel, Oil etc., complete erminal connector suitable ...
SF-6 CIRCUIT BREAKER: SF-6 Circuit Breaker with rigid bi-metallic terminal connector suitable for single/double Drake ACSR with spring / semi-pneumatic / pneumatic type operating mechanism and with mo...
SF-6 CIRCUIT BREAKER: SF-6 Circuit Breaker with rigid bi-metallic terminal connector suitable for single/double Drake ACSR with spring / semi-pneumatic / pneumatic type operating mechanism and with mo...
ISOLATORS: Isolators and Terminal connectors as per Technical specification including solid core cylindrical post insulators with all lead and lifts complete asper specifications and directions of eng...
b) Upright mounting type without earth Switch
i. Live Point Height - 8250mm with all lead and lifts complete asper specifications and directions of engineer in charge of the work.
ii. Live Point Height - 5750mm with all lead and lifts complete asper specifications and directions of engineer in charge of the work.
c) Under hung mounting type without earth switch (13000 mm Mounting Height) with all lead and lifts complete asper specifications and directions of engineer in charge of the work.
1) 220kV, 1250A, 50kA:(For Trf. & PT Bays)
a) Upright without earth Switch
Live Point Height 8250mm with all lead and lifts complete asper specifications and directions of engineer in charg...
Live Point Height 5750mm with all lead and lifts complete asper specifications and directions of engineer in charge of the work.
b. Under hung without earth switch (13000 mm Mounting Height) with all lead and lifts complete asper specifications and directions of engineer in charge of the work.
3) 220kV, 3000A, 50kA:(For I/C Bay) - LPH: 8250mm with all lead and lifts complete asper specifications and directions of engineer in charge of the work.
66kV class Isolators: 66 kV, double break electrically cum manually operated isolators with solid core insulator, terminal connector suitable for 63mm Al. tube/Moose ACSR/Twin Moose ACSR conductor, ma...
66kV class Isolators: 66 kV, double break electrically cum manually operated isolators with solid core insulator, terminal connector suitable for 63mm Al. tube/Moose ACSR/Twin Moose ACSR conductor, ma...
66kV class Isolators: 66 kV, double break electrically cum manually operated isolators with solid core insulator, terminal connector suitable for 63mm Al. tube/Moose ACSR/Twin Moose ACSR conductor, ma...
66kV class Isolators: 66 kV, double break electrically cum manually operated isolators with solid core insulator, terminal connector suitable for 63mm Al. tube/Moose ACSR/Twin Moose ACSR conductor, ma...
66kV, 2000A, 40kA:(For 150MVA Tr. & B/C bay:
Upright without earth Switch Live Point Height 6350mm with all lead and lifts complete as per specifications and directions of engineer in charge of the wo...
Upright without earth Switch Live Point Height 4600mm with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Under hung without earth switch with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
66kV, 3000A, 40kA:(For I/C Bay) - LPH: 6350mm with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
CURRENT TRANSFORMERS: Oil filled Current Transformers with rigid terminal connector suitable for Drake ACSR/Al tube
220kV, 50kA CT of Ratio 1600-800/1-1-1-1-1A (Required for line & Bus-coupler) with ...
220KV, 50kA CT of Ratio 1200-800-600-300/1-1-1A with additional 2 Cores of 1200/1A Type-1(2 Nos. main CTs are used as NCTs) with all lead and lifts complete as per specifications and directions of eng...
ii) 66KV 40KA CT of Ratio 1600-1000/1-1-1A Type-4 (Required for 150MVA Transformer & bus coupler (2 nos. main CTs are used as NCTs) with all lead and lifts complete as per specifications and di...
iii) 66KV 40KA CT of Ratio 400-200/1-1-1A Type-5 (required for 66/11KV Transformer) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
v) 66kV 40KA CT of Ratio 800-400/1-1-1A, (Required for lines) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
iv) 11KV NCT, Outdoor 31.5KA, 2000-1200/1-1-1A (of similar rating as incomer of 2000A, 31.5KA 11KV Switchgear) (Required for 31.5MVA 66/11KV Tr) with all lead and lifts complete as per specifications ...
Voltage Transformer - Single Phase, oil filled outdoor type as per Technical Specification: with terminal connector suitable for Drake ACSR/Al tube :
(i)220KV, VTs of Ratio 220KV/Square root3/110V/Squ...
ii)66KV, VTs of Ratio 66KV/Square root3/110V/Square root3-110V/ Square root3-110V/Square root3,
Core-1-Metering - 300VA, Accuracy 0.2
Core-2-Protection - 200VA, Accuracy 3P
Core-3-Protection - O...
Capacitor Voltage Transformers - 245 kV CVT, 4400 PF, 1 Ph CVT with 2 secondaries, terminal connector suitable for Twin Moose ACSR conductor with marshalling box etc., with all lead and lifts complete...
Surge Arresters with terminal connectors suitable for Drake ACSR:
Note: Surge Arresters are with Surge Monitors & Insulating Base
(i) 198KV, 10KA, Class-III, Metal Oxide Type (Class : SM) with all ...
60KV, 10KA, Discharge Class 3 (Station Medium Duty (SM)), Metal Oxide Type with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Wave Trap: 0.5mH, 2000A, 50kA Pedestal type, along with terminal connector suitable for Twin Moose ACSR conductor with all lead and lifts complete as per specifications and directions of engineer in c...
Relay & Protection Panels:
220 kV Line -Type 2L with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
220/66/11KV Transformer-Type 2T6 with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
220KV Bus Coupler - Type 2BC with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
220KV Bus Bar Protection - Type 2BBA with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
66KV Line- Type 6L with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
66KV Bus Coupler- Type 6BC with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
66/11KV Transformer- Type 6TI with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
11kV line- Type 11L (Provision for 2 feeders to be made in one panel and provision for 1 capacitor bank & 1 feeder to be made in one panel) with all lead and lifts complete as per specifications and d...
Station Structure :
(Rates of Fabrication, galvanising, supply of Mild steel tower materials is considered) (a) 220KV Side Station Structure:
(i) Station Structure Tower - 2T1 with peak wi...
ii) Station Structure Tower - 2T2 without peak with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
iii) Station Structure Beam suitable for fixing under hung isolator - 2B1 with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
iv) Station Structure Beam - 2B2 without under hung isolator with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) 66KV Side Station Structures (i) Station Structure Tower - 1T1 with peak with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
ii) Station Structure Tower - 1T1 with Peak with 2.5 meter extension with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
iii) Station Structure Tower - 1T2 without Peak with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
iv) Station Structure Beam suitable for fixing under hung isolator - 1B1 with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
v) Station Structure Beam 1B2 without under hung isolator with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Lighting mast (2.678 MT+5% for Bolt & Nuts) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Mounting Structures:
(a) 220KV Isolators
(ai) Live Point Height 8250mm with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
aii) Live Point Height 5750mm with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) 66KV Isolators (bi) Live Point Height 6350mm with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
bii) Live Point Height 4600mm with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
ii) Current transformer:
a) For 220KV CTs & NCTs with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) For 66KV CTs & NCTs and 11kV NCTs with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
iii) Voltage transformer :
a) For 220KV VTs/CVTs with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) For 66KV VTs with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
iv) Surge arrestor:
a) For 198kv LAs with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) For 60KV Las with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
220kV: 0.5mH with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
vi) For Post Insulator of Rigid Bus:
a) For 220KV Side with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) For 66KV Side with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
vii) For High Post Insulators for Transformers :
a) For 150MVA, Transformer
220KV side - 6 Nos.
66KV side - 6 Nos. (Bolted Type Foundation)
b) 66/11KV Transformer - 6 Nos. with all lead and lifts c...
viii) 11kV Cable support structure for 1CX1000sqmm cable (11kV side of 31.5MVA transformer) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
ix) 11kV Cable support structure for 3Cx400sqmm cable (for capacitor bank) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
x) 66kV, 1000sqmm cable termination structure with LA mounting with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
RIGID BUS WITH TAPS & CLAMPS:
Aluminium Tube Conforming to 6340 WP of IS-5082/1969 (BS1600-Sch.40) of following sizes with all lead and lifts complete as per specifications and directions of engineer ...
RIGID BUS WITH TAPS & CLAMPS:
Aluminium Tube Conforming to 6340 WP of IS-5082/1969 (BS1600-Sch.40) of following sizes with all lead and lifts complete as per specifications and directions of engineer ...
RIGID BUS WITH TAPS & CLAMPS:
Aluminium Tube Conforming to 6340 WP of IS-5082/1969 (BS1600-Sch.40) of following sizes with all lead and lifts complete as per specifications and directions of engineer ...
RIGID BUS WITH TAPS & CLAMPS:
Aluminium Tube Conforming to 6340 WP of IS-5082/1969 (BS1600-Sch.40) of following sizes with all lead and lifts complete as per specifications and directions of engineer ...
Moose ACSR Conductor with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Formation of Main/ Cross bus 220kV side
Moose ACSR Conductor with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Formation of Main/ Cross bus 66kV side
Post Insulators - Cylindrical Solid Core Insulators as per IS:5350, Part-II & III
a). For 220KV Side-2 Units / Stack
i. Post Insulators of Rigid Bus with all lead and lifts complete as p...
Post Insulators - Cylindrical Solid Core Insulators as per IS:5350, Part-II & III
a). For 220KV Side-2 Units / Stack
ii. High level Post Insulators for 150MVA Tr., with all lead and lifts...
Post Insulators - Cylindrical Solid Core Insulators as per IS:5350, Part-II & III
b)For 66KV Side-1 Unit/Stack
i. Post Insulators of Rigid Bus with all lead and lifts complete as per specifications...
Post Insulators - Cylindrical Solid Core Insulators as per IS:5350, Part-II & III
b)For 66KV Side-1 Unit/Stack ii. Post Insulators (for 150MVA Tr.-6 Nos. 31.5MVA Tr. 6 Nos) with all lead and lifts co...
Auxiliary Transformers with oil, cable termination type on both HT & LT, outdoor type: with off load tap changer in steps of 2.5% with all lead and lifts complete as per specifications and directions ...
LTAC panel (indoor):
415V, LTAC panel (2 I/C ACB 800A+2 O/G SFU, 200A + 8 O/G SFU 100A+14 O/G SFU, 63A+12 O/G SFU, 32A+1B/C SFU, 800A+1DG Change over switch 300A etc. with all lead and lifts comp...
a) Power Cable from Auxiliary Transformers to LTAC panel:
1.1 kV PVC Insulated 240 Sqmm Al.cable 3.5 core with glands /lugs/Ferrules with all lead and lifts complete as per specifications and directio...
b) PVC insulated aluminium power cable (AC supply for lighting etc):
70 Sq.mm 3.5 Core, with glands / lugs / ferrules with all lead and lifts complete as per specifications and directions of engineer...
AC Distribution Box (outdoor):
i. AC Distribution Box Double front type, 24 terminals, 1200 x 1350 x 600mm, 2I/C of 100A, MCCB 20KA + 24 O/G MCB 16A+20/G of 100A, HRC fuse with all lead and lifts comp...
ii. AC Distribution Box Single front Type, 6 terminals, 750 x 1350 x 300mm, 1 I/C of 100A, MCCB 20KA+6 0/G MCB 16A + 1 O/G of 100A, HRC Fuse with all lead and lifts complete as per specifications and ...
Station Battery & Battery charger:
2x220V, 300AH Battery Set consisting of 110 No. Cells per bank with float (2 Nos.) & boost (2 Nos.) type battery charger including control panels, change over arrang...
Control cable: PVC Insulated Copper Control Cable with lugs / ferrules (Refer annexure for details at the end of this schedule of quantities) with all lead and lifts complete as per specifications an...
2.5 Sq.mm 14 Core with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
2.5 Sq.mm 10 Core with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
2.5 Sq.mm 4 Core with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
2.5 Sq.mm 7 Core with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
6 Sq.mm 4 Core with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
16 Sq.mm 4 Core with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
4 Sq.mm 4 Core with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
70 sq.mm 2 Core with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
1PX0.5 sq mm Screened cable with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
11KV Switchgear: 31.5kA, 2600A for incomer and 1250A for feeders (2IC+1BC+16F+4CB+1AP)-DAS compatible as per Technical specification. Annunciator panel shall be simplex panel instead of desk type ment...
11KV UG Cable with the required cable terminations:
[a] 11KV XLPE 95 Sq.mm Aluminium Cable-3 Core (for two auxiliary transformers from the 11KV Switchgear) with all lead and lifts complete as per spe...
b)11KV XLPE Cable, 1000 Sq.mm Aluminium Cable - 3x4 runs of IC x 1000 Sq.mm cable from 66/11KV Transformers to 11KV Switchgear with all lead and lifts complete as per specifications and directions o...
c)11kV XLPE 400Sq.mm Aluminium Cable - 3 Core to be run from 11kV Switchgear to 11kV take off DP Structure & 11kV Capacitor bank with all lead and lifts complete as per specifications and directions ...
11kV Cable Termination Kit suitable for following sizes as per Technical Specification. :
400 Sq.mm 3 Core For Capacitor bank - Indoor with all lead and lifts complete as per specifications and direct...
400 Sq.mm 3 Core For Capacitor bank - Outdoor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
95 Sq.mm 3 Core - Indoor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
95 Sq.mm 3 Core - Outdoor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
1000 Sq.mm Single Core- Indoor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
1000 Sq.mm Single Core- Outdoor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
400Sq.mm 3 core for Feeder - Indoor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
400Sq.mm 3 core for Feeder - Outdoor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
STATION & YARD LIGHTING (OUTDOOR) (To be designed, assessed & quoted by the bidder):
Supplying and erection of street lighting lattice type structure along with GI pipe for fixing of LED lamp (0.182 ...
PVC Insulated Copper Control Cables : 1.1 KV PVC insulated Copper Control Cable with glands/Lugs/ Ferrules etc as per technical specification.
2C x 6 sqmm with all lead and lifts complete as per spec...
12.1kV, 5.8 MVAR Capacitor bank with series reactor, NCT, LA etc as per specification along with mounting structure with all lead and lifts complete as per specifications and directions of engineer in...
11KV Isolator & DP Structure :
(a) 11KV Double Break isolator 400A, 25KA with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
b) 11KV RCC DP structure for mounting Isolator & LA with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
c) 11kV DB Isolator, 400A, 25kA with lattice type mounting structure (for 11kV capacitor bank) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
d) 11kV DB Isolator, 400A,25kA with LA(for Auxilliary transformer) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
e) 11kV RCC DP structure for mounting 11kV DB Isolator for Auxilliary transformer with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
SCADA and Communication Equipments: Communication equipment :
a)SDH Equipment : (STM-16 MADM, upto 3 MSP 1+1 protected directions) with 60 G Higher Order as well
as Lower Order - Base Equipment (comm...
Tributary Interface:
Cabinet Equipment to house SDH Equipment + Optical cards + Tributary Cards, Drop/Insert MUX Equipments and DACS Equipment with all lead and lifts complete as per specifications an...
220V DC to 48V DC Converter for SDH Equipment with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
IP phone with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Digital protection coupler with 8 command version (Direct fiber intype) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
48V Battery Charger suitable for 200AH Battery set with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
48V, 200AH Battery Set with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Earth Mat Formation::
Supplying and laying MS flat 75 x 12 mm flat welding and applying ACB paint to welded portion and covering with soil as per drawing / standards without sodium bentonate clay (all...
Grounding of equipments with 75x12 mm G I flat and connecting equipments to the earth mat/ ground pit including all connected works with all lead and lifts complete as per specifications and direction...
Providing MS Round rod 1.075 metre long earthmat spikes including heating, bending top 50/75 mm overlap flattening and making spike edge at one end driving into the earth below the ground level and we...
Providing C.I . Pipe of 100mm ID 13mm thick 2.75mtr long with 2 part GI flat 50x6 mm clamp welded all round the pipe etc., including cost of excavation with all lead and lifts complete as per specifi...
Suppling and fixing 450mm dia x450mm height 1.5" to 2" Hume pipe collars for earth pits with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Providing Deep Bore Earthing:
Sinking bore of 150 mm clear dia using fast rig including fixing of 40 mm dia MS Rod, including jointing the pipes as per KPTCL standard and providing sodium bentonite tr...
Drilling 150 mm dia bore (10 mtr long rod) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
40 mm dia MS Rod with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Bentonite Clay (60 kgs per location) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Cost of GI Flat for joining two rods by welding to obtain
continuous length (6 mtr rod = 1 joint per location) with all lead and lifts complete as per specifications and directions of engineer in char...
Station Civil Portion:
Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 30...
Construction of embankment with approved materials deposited at site from road way cutting and exacavtion from drain and foundation of other structures and excavated from levelling and lowering the gr...
Construction of embankment by excavating the available approved gravel/murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading,...
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggr...
Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/tra...
Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/tra...
Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/tra...
Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/tra...
Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/tra...
Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/tra...
Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/tra...
Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/tra...
Providing and laying in position Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc.. The ranite/trap/basalt crushed graded coarse aggr...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggr...
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with PVC Pipe 110mm outer dia at 2 kg per m2, extending through the full width of the structure with ...
Providing and laying of Filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than...
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 ...
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS...
Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/w...
Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/w...
Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a 2 coat of approved pa...
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by r...
Disposal of surplus earth/ rock/ unwanted stuffs to the areas directed/notified areas of disposal point of the local bodies including all lead and lift charges, transportion, loading and unloading etc...
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) inc...
Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2...
Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, includ...
Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of m...
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth with all lead and ...
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work over one coat of primer after thoroughly brooming the surface to remove all dir...
Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with pai...
Providing Water based glossy paint (Green certified product) to Kerb Stones as per IS 164:2015 technical specifications including cleaning & surface preparation with all lead and lifts complete as per...
Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's pecifications including appropriate priming coat, preparation of surface, etc. complete. On concrete ...
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direct...
Fencing with G.I. barbed wire Angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and...
Providing and fixing double action hydraulic floor spring of approved brand manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door we...
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on ...
Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastom...
Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead fr...
Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minim...
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windo...
Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of appr...
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 m...
Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nomina...
Providing and laying 5mm thick Self levelling Epoxy Flooring for Residential, Commercial, Sports & Industrial purpose made of reputed brand applied at 1L/m2 on existing Concrete substrate of 25Mpa or ...
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitt...
Design, engineering, providing and fixing of KPTCL logo and name of the substation and other required details on the existing entrance portion of wall of sub station with approved material, letters bo...
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) greater than 78, solar reflection greater than 0.70 and initial emittance greater than 0.7...
Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed t...
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, ...
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and jo...
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and jo...
Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. with all lead and lifts complete as per specification & direction of Engineer in charge of the work.
Providing and fixing bright finished brass butt hinges with necessaryscrews etc. complete. 125x85x5.5mm (Heavy type) : with all lead and lifts complete as per specification & direction of Engineer in ...
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc...
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. with all lead and lifts complete as p...
Providing & fixing CPVC pipes having thermal stablity for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00M spacing. this in...
Providing & fixing CPVC pipes having thermal stablity for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00M spacing. this in...
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of
fittings and brackets, cutting and making good the...
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard ...
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing. Rectangula...
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32 mm dia with all lead and lifts complete as per specification & direction of Engineer in charg...
Providing and fixing 100 mm sand cast Iron grating for gully trap with all lead and lifts complete as per specification & direction of Engineer in charge of the work.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with ...
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge with all ...
Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat & lid fixed with C.P. brass hinges and rubber b...
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings with all lead and lifts complete as per specification & direct...
Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less ...
Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore with all lead and lifts complete as per specification & direction of Engineer in c...
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 with all lead and lifts complete as per specification & direction of Engineer in charge of the work.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be...
Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsatura...
Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joint...
Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joint...
Providing S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work ...
Providing S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work ...
Providing Size Stone masonry with hard stone in foundation & plinth with
Cement mortar 1:6 (1 cement : 6 coarse sand) with all lead and lifts complete as per specification & direction of Engineer in ...
Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm in concrete slab using concrete cutting machine with diamond studded saw within 4-8 hours of casting of bay / slab etc. complete inc...
Providing and filling joint sealing compound as per approved drawing and technical specification with coarse sand and 6 percent bitumen by weight with all lead and lifts complete as per specification ...
Providing and fixing rainy make rain water filter of FL500 with all lead and lifts complete as per specification & direction of Engineer in charge of the work.
Providing & fixing suitable capacity mono submersible/mono block pump set for rain water sump, cable ducts etc., with electrification including necessary cables, starter and control panels etc., with...
Sinking of borewell of 165mm mm clear using Super fast hydrualic rig of capacity 3000PSIG and above 1100CMF and above in all strata including over burden upto 20 m fixing of casing pipe, collers and c...
Sinking of borewell of 165mm mm clear using Super fast hydrualic rig of capacity 3000PSIG and above 1100CMF and above in all strata including over burden upto 20 m fixing of casing pipe, collers and c...
Sinking of borewell of 165mm mm clear using Super fast hydrualic rig of capacity 3000PSIG and above 1100CMF and above in all strata including over burden upto 20 m fixing of casing pipe, collers and c...
Sinking of borewell of 165mm mm clear using Super fast hydrualic rig of capacity 3000PSIG and above 1100CMF and above in all strata including over burden upto 20 m fixing of casing pipe, collers and c...
Sinking of borewell of 165mm mm clear using Super fast hydrualic rig of capacity 3000PSIG and above 1100CMF and above in all strata including over burden upto 20 m fixing of casing pipe, collers and c...
Sinking of borewell of 165mm mm clear using Super fast hydrualic rig of capacity 3000PSIG and above 1100CMF and above in all strata including over burden upto 20 m fixing of casing pipe, collers and c...
Sinking of borewell of 165mm mm clear using Super fast hydrualic rig of capacity 3000PSIG and above 1100CMF and above in all strata including over burden upto 20 m fixing of casing pipe, collers and c...
Sinking of borewell of 165mm mm clear using Super fast hydrualic rig of capacity 3000PSIG and above 1100CMF and above in all strata including over burden upto 20 m fixing of casing pipe, collers and c...
Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 andlatest ammendments, electrical resistance welded steel tubes, ma...
Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum...
Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner o...
Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engi...
Supply and delivery at site Brand new best make PVC insulated submersible cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendme...
PRESSURE GAUGE :
Supply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments. For size 100mm with all lead and lift...
Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments. Size 50 mm with all lead and lifts complete as per specifi...
NON - RETURN VALVE :
Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments. Size 50 mm with all lead and lifts complete ...
Control panel board for borewell motor pumpset:
Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of su...
POWER CAPACITOR :
Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissionin...
Supply and delivery at site delivery of best indigenous brand new MCB(Miniature Circuit Breakers) of required capacity as per IS 88228/1978
and its latest amendments and with ISI Mark of 6/10/1...
Supplying & installation of 50mm dia HDPE pipes of specified grade and confirming to IS standards and direction of engineer in charge of work including cost of labour, materials etc., with...
Erection elctrification & Commissioning works of pumpsets :
Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including sup...
Main connections:
Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board un...
ELECTRICAL ACCESSORIES:
Supplying of TPST with reqirable porcelain channels in SM enclosure, made out of 14 SWG powder coated paint of approved colour. 32 AMPS. with all lead and lifts complete as pe...
Supplying and fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32 AMPS with all lead and lifts complete as per specification & direction o...
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipe...
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipe...
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipe...
Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plaster...
Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plaster...
Providing and fixing SFRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fix...
Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/...
Providing, laying, spreading and compacting graded stone aggregates to wet mix macadam specifications including premixing the materila with water at OMC in mechanical mix plant carriage of mixed mater...
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to me...
Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA & for Residential...
Bituminous layer for oil sump: Styrene Butadiene Styrene (SBS ) based :Providing and laying of 1.5 mm thick SBS modified self adhesive single stick waterproofing membrane, with minimum elongation of 3...
Providing and fixing modular cable cealing system as per KPTCL specfication including cost of materials, labour charges, etc., with all lead and lifts complete as per specification & direction of Eng...
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and ...
Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the sl...
Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the sl...
Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and ...
Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and ...
Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 100x75x65mm with all lead and...
Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 135x75x65mm with all lead and...
Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF...
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire...
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire...
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/ Stone/ C.C wall...
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/ Stone/ C.C wall...
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/ Stone/ C.C wall...
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone / C.C wall...
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing m...
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing m...
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing m...
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing m...
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch with all lead and lifts complete as per specification & dir...
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Two Way Switch with all lead and lifts complete as per specification & dir...
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket with all lead and lifts complete as per specification & d...
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator Two Module with all lead and lifts complete as per spec...
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch with all lead and lifts complete as per specification & direct...
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 12933 6/16A Universal Socket with all lead and lifts complete as per specification...
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Ov...
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capa...
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capa...
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capa...
Supplying, fixing andwiringResidualcurrentcircuitbreaker(RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.16-25 A 2 pole with all lead and lifts complete as per specification & dire...
Supplying, fixing and wiring earth leakage relay with corebalanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage curr...
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter with all lead and lifts complete as per specification & direction of Engineer in charge of the work.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. with all lead and lifts complete as per specification & direction of Engine...
Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply with all lead and lifts complete as per specification & d...
Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.15" Sweep (450 mm) with all lead and lifts complete as per specification & directio...
Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball be...
Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R41...
Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C with all ...
Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas...
Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries with all lead and lifts complete as per sp...
Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 5...
Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree ...
Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree ...
Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree ...
INDUSTRIAL HIGHBAY LUMINAIRE ( INTEGRAL TYPE) Industrial medium/high bay luminaire with integral type Control gear, copper wound ballast, visor glass assembly and including supply of lamps. 100W, 240...
Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polyca...
Supplying and fixing of LED Bulkhead of 10W with IP65 protection and IK08 impact resistance suitable for surface and wall mounting applications with all lead and lifts complete as per specification & ...
Supply and fixing Battery operated portable fluoresent lamps with all lead and lifts complete as per specification & direction of Engineer in charge of the work.
Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, r...
Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary ...
Extra length of GI pipe of class B 19mm dia for down rod with all lead and lifts complete as per specification & direction of Engineer in charge of the work.
Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with...
Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v input and load variation from no load to full load, with over load protection, spike suppression, operati...
Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of sa...
Supply of LED Street light luminair ewith pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising ofanti glare clear diffuserwith Injectionmouldedpolycarbo...
4 Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN10025 grade S355JO steel plate for shaft, IS2062forbaseplatewithdooropeningarrangements, including...
Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgi...
Supply and Installation /Fixing /Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent PolycarbonateLid, shockproof, IP65(WeatherProof), rust proof, dustproof, waterproof, c...
Jelly Spreading (20-25 mm) : Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete....
220kV UG Supply:220kV Single core 1200 Sq.mm., XLPE insulated, Lead Sheathed overall PE Sheathed UG cable (E) grade,1 core, circular, stranded, plain annealed compacted, milliken copper conductor, sc...
Normal Straight through joints suitable for 220KV 1 core pre moulded design 1200sq.mm copper conductor, XLPE lead sheathed cable with all lead and lifts complete asper specifications and directions of...
Out door type Cable end termination Polymeric Design/ Pre moulded outdoor type suitable for the above 220kV (E) class single 1 core 1200 sq.mm lead sheathed cable including PVC Earthing cable with all...
Indoor type cable termination (plug in dry type) suitable for GIS modules confirming to IEC 62271-209 for 220 kV, 1200 Sq mm, copper conductor XLPE insulated cable including PVC earthing cable with al...
220 kV Link boxes, single phase outdoor structure mounting type with SVL/CCPU suitable for 1200sqmm UG cable including the cost of 400sq.mm sheath bonding cable with all lead and lifts complete asper ...
220kV Link boxes, three phase buried type with SVL/CCPU including 400sq.mm sheath bonding cable and 400/400sq.mm co-axial cable as per technical specification suitable for 220kV 1200sq.mm UG cable. ...
220kV Surge arrestor:198 kV Metal Oxide type, with surge counter (Discharge Class - 3) with all lead and lifts complete asper specifications and directions of engineer in charge of the work.
Terminal connectors to connect cable end termination to the AAAC Moose conductor with all lead and lifts complete asper specifications and directions of engineer in charge of the work.
PLCC Equipments :
Unarmoured Underground FO cable (48 DWSM) with all lead and lifts complete asper specifications and directions of engineer in charge of the work.
Polyvinyl Lubricated Bond (PLB) HDPE OD 40mm pipe with accessories with all lead and lifts complete asper specifications and directions of engineer in charge of the work.
Straight Joint kit for optical fibre cable with all lead and lifts complete asper specifications and directions of engineer in charge of the work.
Line Interface unit suitable for 48F optical fibre cable with all lead and lifts complete asper specifications and directions of engineer in charge of the work.
OPGW to OFC jointing kit 48F with all lead and lifts complete asper specifications and directions of engineer in charge of the work.
Media Converter with all lead and lifts complete asper specifications and directions of engineer in charge of the work.
Collars for PLB Pipe with all lead and lifts complete asper specifications and directions of engineer in charge of the work.
UG CABLE MANDATORY SPARES:
220kV Single core 1200 Sq.mm., XLPE insulated, Lead Sheathed overall PE Sheathed UG cable (E) grade,1 core, circular, stranded, plain annealed compacted, milliken copper co...
Normal Straight through joints suitable for 220KV 1 core pre moulded design 1200sq.mm copper conductor, XLPE lead sheathed cable with all lead and lifts complete asper specifications and directions of...
Out door type Cable end termination Polymeric Design/ Pre moulded outdoor type suitable for the above 220kV (E) class single 1 core 1200 sq.mm lead sheathed cable including PVC Earthing cable with all...
Indoor type cable termination (plug in dry type) suitable for GIS modules confirming to IEC 62271-209 for 220 kV, 1200 Sq mm, copper conductor XLPE insulated cable including PVC earthing cable with al...
220 kV Link boxes, single phase outdoor structure mounting type with SVL/CCPU suitable for 1200sqmm UG cable including the cost of 400sq.mm sheath bonding cable with all lead and lifts complete as per...
220kV Link boxes, three phase buried type with SVL/CCPU including 400sq.mm sheath bonding cable and 400/400sq.mm co-axial cable as per technical specification suitable for 220kV 1200sq.mm UG cable. ...
220kV UG ERECTION:
UG Cable survey: Surveying of cable route, excavation trial holes as per field requirements, preparation of cable route profile drawings for cable laying, final route alignment, mar...
Laying including testing and commissioning :
Laying of 220KV single core, 1200sqmm sqmm XLPE Segmental compact type miliken Copper cable in trefoil, tapping , fixing pipes for drain and gate crossin...
Handling & making normal straight joints/ insulated shield break type for 220 KV power cables with all consumables at site etc., with all lead and lifts complete asper specifications and directions o...
Handling & making of cables end termination for 220KV power cables with all consuambles at site etc., with all lead and lifts complete as per specifications and directions of engineer in charge of th...
Erection of single phase earth link boxes (3 Nos), on to the cable end termination structure/tower connecting earth leads with all lugs, fixtures, clamps, bolts, and nuts with all lead and lifts compl...
Erection of three phase earth link boxes at joint bay/structure with connecting earth leads, all lugs, fixtures, clamps, bolts, and nuts complete. (for straight/ cross bonds) with all lead and lifts c...
Laying of 24 / 48 fibre dual window mono mode (DWMM) optical fibre cable as per drawings & specifications with all lead and lifts complete as per specifications and directions of engineer in charge of...
Survey & documentation with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Handling & making straight through joints closures for 24/ 48 fibre dual window mono mode ( DWMM) optical fibre cable with all lead and lifts complete as per specifications and directions of engineer ...
Handling & making terminal joints for 24/48 fibre dual window mono mode ( DWMM) optical fibre cable with all lead and lifts complete as per specifications and directions of engineer in charge of the w...
Erection of Surge Arrestor:
198 kV Metal Oxide with surge counter Arrestor class : Station Medium Duty (SM) - Discharge Class 3 - for Overhead Line, Transformer & UG Cable with all lead and lifts comp...
Charges for conducting precommissioning tests as per IEC 60840, IS 7098 Part - III and successful commissioning of UG Transmission line with all lead and lifts complete as per specifications and dire...
Grounding of equipments by providing cast iron pipe of 100 mm ID 13mm thickness , 2.75 m long with 2 part clamp out of GI flat 50X6 mm as per drawing including the cost of excavation with all lead and...
Supplying & Providing 450mm dia 450mm height 1.5" to 2' thich hume pipe collar (non pressure type) for eatrth pits with all lead and lifts complete as per specifications and directions of engineer in ...
Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, ...
Earth work excavation for Foundation by mechanical means for all works &depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lig...
Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bra...
Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specification, including setting out, construction of shoring, strutting, cost of blasting materials, barri...
Dismantling of Flexible pavements and disposal of dismantled materials and stacking serviceable and unserviceable materials separately By Bituminous course with all lead and lifts complete as per spe...
Dismantling of Flexible pavements and disposal of dismantled materials and stacking serviceable and unserviceable materials separately By Mechanical Mean Granular course with all lead and lifts compl...
Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 m3 in volume and stock piling at designated locations and disposal of dismantle...
Providing M-Sand : Supplying and filling in plinth, foundations / UG cable work with approved M-sand including watering, ramming, consolidating and dressing. The rate includes the cost of material, la...
Supplying and Providing pre cast RCC Protection Covers using M20 grade Concrete, steel of approved size/shape (as per the approved drawings) to be laid in UG cable works. The rate includes the cost of...
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5...
Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work with all lead and lifts complete as per specification & direction of Engineer in charg...
Supplying and Providing Pre cast Cable Route/ Joint marker using M15 grade Concrete, MS rods of approved size/shape (as per the approved drawings) to be laid in UG cable works. The rate includes the c...
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes...
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes...
Providing and laying of warning tape / Caution tape / detector tape for HDPE pipes of 200 mm wide, 300 micron thick, blue in colour confoming to relevant ISS with latest amendments with appurtenances....
Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and ...
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes...
a) HDD method for 220 kV UG Cable work: Supply & Installation of 3 rows of HDPE pipes PE 80 PN6 of 250 mm dia using Horizontal directional drilling technique (HDD method) including preparing and setti...
Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/w...
Construction of Granular Sub-Base of grading V material as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on...
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Materia...
Prime Coat over WMM/WBM: Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0...
Tack coat on Granular surface treated with primer:Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.25 kg/m2on the prepared bituminous ...
Dense graded Bituminous Macadam Grading - II for traffic less than20MSA
Providing and laying Dense Graded Bituminous Macadam with 120 TPH capacity HMP batch type using crushed aggregates of specified ...
Bituminous concrete Grading - II for traffic less than20MSA
Providing and laying Bituminous Concrete with 120 TPH capacity hot mix plant batch type using crushed aggregates of specified grading, premi...
220kV Monopole Sply: Fabrication, Proto testing and supply of Galvanised 220kV DC & MC Monopoles including cross arms, base plates with anchor bolts, anticlimbing device, step bolts and Bolt & Nuts a...
Tower Accessories: Number Plates (1 No. per tower) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Danger Plates (1 No. per tower) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Circuit Plates (1 No. per circuit) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Phase Plates (Set of 3 Nos.) with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Earth Bonds with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 450mm long
Grounding of tower including cost of 40mm dia, 2.5mm thick, class 'C' GI pipe of 3mtrs length as per specifications with 50x6 GI flats 3 mtrs long, salt, charcoal, including excavation charges with al...
Supply and fixing GI angle iron 45 x 45 x 5 mm (1m length) with cleats, bolts & nuts as per specifications and fixing above 0.5m length each at inner and outer surface of the tower to facilitate runin...
Supplying and fixing of barbed wire as per specifications with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Conductor, Insulators & Hardwares:
AAAC Moose conductor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
220kV, 120kN Tension type Silicon rubber composite insulator equivalent to 1X16nos. of 120kN Disc - 2175mm with all lead and lifts complete as per specifications and directions of engineer in charge ...
220kV, 120kN Suspension type Silicon rubber composite insulator equivalent to 1X14nos. of 120kN Disc - 2030mm
For Pilot Insulator with all lead and lifts complete as per specifications and directions...
Double Suspension clamp with hardwares & arcing horns suitable for 1X16 units of 120KN insulators to suit AAAC Moose conductor with all lead and lifts complete as per specifications and directi...
Double Tension clamp with hardwares & arcing horns suitable for 1X16 units of 120KN insulators to suit AAAC Moose conductor with all lead and lifts complete as per specifications and directions ...
Mid span compression Joints suitable for AAAC Moose Conductor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Repair sleeves suitable for AAAC Moose Conductor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Vibration Dampers for AAAC Moose Conductor with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
OPGW Cable and its Accessories:
48F (DWSM) OPGW fibre optic cable with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Suspension clamp assembly with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Tension Assembly: Dead end with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Double tension pass through/passing tension with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Tension tower joint box location including all accessories with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Suspension Tower joint box location including all accessories with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Vibration Damper with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Down Lead Clamp Assembly with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
Joint Box with all lead and lifts complete as per specifications and directions of engineer in charge of the work.
FODP 96F : Indoor type consisting of 2 nos. of rack
mounted LIU (to be housed in FODP) with 24 ports
each with FCPC coupling & pig with all lead and lifts complete as per specifications and directions...
FIBRE OPTIC ARMOURED APPROACH CABLE ::
48 Fibre (DWSM) including Installation Hardware
set for 48 Approach Cable with all lead and lifts complete as per specifications and directions of engineer in ch...
220kV Monopole erection:
Check survey to be conducted during construction stage: Conducting detailed check survey along the approved route duly following the route alignment, GPS co-ordinates, submiss...
Conducting Drone survey of Transmission Lines for collection of data along with Aerial inspection of EHV Line coridor using LIDAR method for meaasurements of vertical, horizontal and ground clerances ...
Design, developing Structural and Shop drawings of 220 kV Multi- Circuit/double circuit design based Monopole Towers as per the Technical Specifications including foundations (Including prototype ass...
b) 220kV MC MP4 plus 3 (30deg-60deg) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
c) 220kV MC MP4A plus 0 (0deg-90deg) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
d) 220kV DC DP2 plus 3 (0-15deg) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
e) 220kV DC DP 4 plus 3 (30deg-60deg) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
220kV Monopole Erection: Fabrication, Proto testing and supply of Galvanised 220kV DC & MC Monopoles including cross arms, base plates with anchor bolts, anticlimbing device, step bolts and Bolt & Nut...
Tower Accessories:
Number Plates (1 No. per tower) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Danger Plates (1 No. per tower) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Circuit Plates (1 No. per circuit) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Phase Plates (Set of 3 Nos.) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Grounding of tower including cost of 40mm dia, 2.5mm thick, class 'C' GI pipe of 3mtrs length as per specifications with 50x6 GI flats 3 mtrs long, salt, charcoal, including excavation charges with al...
Conductor, Insulators & Hardwares:
Stringing of Moose Conductor: Paving out conductor from anchor to anchor normally spaced at 5 spans with 4 tangent towers in between, including providing stays at e...
OPGW Cable and its Accessories:
48F (DWSM) OPGW fibre optic cable with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Joint Box with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Installation, testing & commissioning of FODP for 24F/48F/96F : Indoor type, rack mounted with FCPC coupling and pigtails with all lead and lifts complete as per specifications and direction of ...
FIBRE OPTIC ARMOURED APPROACH CABLE :
Laying, installation, testing & commissioning of 12/24/48 F Optical fibre approach cable in switch yards of 400 kV & 220 kV (Including hardware)
along with HDPE P...
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite /trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant I...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/w...
Dismantling of Flexible pavements and disposal of dismantled materials and stacking serviceable and unserviceable materials separately By Mechanical Mean Bituminous course with all lead and lifts com...
Dismantling of Flexible pavements and disposal of dismantled materials and stacking serviceable and unserviceable materials separately By Mechanical Mean Granular course with all lead and lifts compl...
Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 m3 in volume and stock piling at designated locations and disposal of dismantle...
Construction of Granular Sub-Base of grading V material as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on...
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Materia...
Dense Graded Bituminous Macadam grading II for traffic less than20 MSA
Providing and laying Dense Graded Bituminous Macadam with 120 TPH capacity HMP batch type using crushed aggregates of specified g...
Bituminous Concrete grading II for II for traffic less than20 MSA
Providing and laying Bituminous Concrete with 120 TPH capacity hot mix plant batch type using crushed aggregates of specified grading,...
Tower Protection: Provision for Providing safety damage protection cage around Monopole tower as per specification and design inclusive of supply of all materials, erection charges and civil work.
Liners used in Monopoles foundation works with GI sheets of thickness 1.2mm to protect Steel reinforcement from corrosion (to avoid direct contact with soil) including supply, formation etc., comlpete...
Cable terminating tower Protection (Drawing approved for Haralur - Muddenahalli project): Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls,...
Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of appro...
Providing and fixing G.I. chain link fabric fencing of required width in
mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts,
bolts and washers as required complete as per the direct...
Fencing with G.I. barbed wire 2x3 rows of 12SWG Galvanised Barbed wire confirming to IS 278 as per approved drawings and specifications etc. with all lead and lifts complete as per specification & dir...
Metal encapsulated SF6 gas insulated Switchgear 220kV 50kA rating suitable for outdoor installation of modular design. The make of GIS shall be M/s. Siemens make.
Note: The proposed GIS mo...
Outdoor Local Control Cubicle for 220 kV line (UG cable) module as per specification with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
1) Relay & Protection Panels, SAS and LCC panel:-
220 kV Line -Type 2L (Annexure RPP1-Cable -SAS) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work...
AC Distribution Box (outdoor)::
AC Distribution Box single front type, 6 terminals, 1 I/c of 100A, MCCB 20kA+6 O/G MCB 16A+ 1 O/G of 100A, HRC fuse with all lead and lifts complete as per specificatio...
Copper Control cable:
PVC Insulated Copper Control Cable with lugs / ferrules (Refer annexure for details at the end of this schedule of quantities)
2.5 Sq.mm 19 Core with all lead and lifts complete...
2.5 Sq.mm 14 Core with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
2.5 Sq.mm 10 Core with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
2.5 Sq.mm 4 Core with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
6 Sq.mm 4 Core with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
4 Sq.mm 4 Core with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
2Px0.5 Sq.mm screened cable for 4-20mA signal Transmission with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Communication Equipments:
Multi Function Transducer (MFT) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
8 Channel 220/110 V Opto Coupler with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Signal cable : Armoured Copper 10C x 0.5 Sq mm
multistrand with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
10C x 1.5 Sq mm multistrand, conforming to
KPTCL specification with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
3C x 4 Sq mm multistrand for AC input to UPS and
UPS to RTU, conforming to KPTCL specification with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
1C x 32 Sq mm multistrand for battery conforming
to KPTCL specification with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Current cable copper core 4Cx4sqmm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Voltage cable copper core 4Cx2.5sqmm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Manadatory Spares:
For GIS Common Spares, Maintenance and Testing Tools:
SF6 Gas pressure relief devices of each type with all lead and lifts complete as per specifications and direction of Engineer i...
Pressure gauges (of each type) along with coupling device with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Rubber Gaskets, “o” Rings and seals for SF6 gas with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Molecular filter for SF6 gas with all lead and lifts complete as per specifications and direction of Engineer in charge of the work. (3 Set)
Density Monitors for SF6 gas with all lead and lifts complete as per specifications and direction of Engineer in charge of the work. (2 Nos)
All types of Control Valves for SF6 gas with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
SF6 gas with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
220 / 66 kV Bushing for connection to GIS duct with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
CIRCUIT BREAKERS:- GIS
SF6 CIRCUIT BREAKER: All spares shall be for 220KV and 66KV separately
220 kV, Single ph., 2000A Circuit Breaker interrupting chamber complete with all necessary apparatus wit...
Rubber gaskets, O' rings and seals with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Trip coils with resistor with all lead and lifts complete as per specifications and direction of Engineer in charge of the work. (3 nos.)
Closing coils with resistor with all lead and lifts complete as per specifications and direction of Engineer in charge of the work. (3 nos.)
Relays, Power contactors, push buttons, timers & MCB etc., with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Closing assembly/ valve with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Trip assembly/ valve with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Pressure switches with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Auxiliary switch assembly with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Operation Counter with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Rupture disc/diaphragm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Windoscope / Observing window with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
a) 220 kV, Single ph., 2000A Circuit Breaker operating mechanism, with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
All types of coupling for SF6 gas(1 no. each type) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
ISOLATORS & E/SWITCH GIS:
a) 220 kV, Single ph., 1600A Disconnecting & maintenance earthing Switch internal parts, complete with all necessary gaskets, mounting hardware, etc. with all lead and lift...
a) Operating mechanism of 220kV, 1600A Disconnecting Switch, complete with all necessary connecting apparatus with all lead and lifts complete as per specifications and direction of Engineer in charge...
a) 220kV, 1600A, single phase high speed fault making Earthing switch, Internal parts complete with all necessary gaskets mounting hardware etc. with all lead and lifts complete as per specifications...
a) Operating mechanism of 220kV, 1600A, high speed fault making Earthing switch, complete with all necessary gaskets connecting apparatus with all lead and lifts complete as per specifications and di...
Limit switch & Aux. switches with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
CURRENT TRANSFORMER - GIS:
Complete CT 220 kV with terminal connector (1 no. of each rating) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
VOLTAGE TRANSFORMER - GIS:
Single phase VT complete with all gaskets and mounting hardware. (220 kV) with all lead and lifts complete as per specifications and direction of Engineer in charge of the ...
SURGE ARRESTOR - GIS:
Complete L.A. including with Surge counter & accessories: (i) 220 kV with all lead and lifts complete as per specifications and direction of Engineer in charge of the work. (1 n...
Relay Panel Spares: SPARES FOR RELAY AND PROTECTION PANELS:
All type of Numerical relays with all lead and lifts complete as per specifications and direction of Engineer in charge of the work. (1 no....
Trip circuit supervision relay with all lead and lifts complete as per specifications and direction of Engineer in charge of the work. (2 Nos)
Self reset trip relay with all lead and lifts complete as per specifications and direction of Engineer in charge of the work. (1 no. of each type)
Hand reset trip relay with all lead and lifts complete as per specifications and direction of Engineer in charge of the work. (1 no. of each type)
Timer relay with all lead and lifts complete as per specifications and direction of Engineer in charge of the work. (1 no. of each type)
DC supervision relays with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Flag relays with all lead and lifts complete as per specifications and direction of Engineer in charge of the work. (1 no. of each type)
Auxiliary relays with all lead and lifts complete as per specifications and direction of Engineer in charge of the work. (1 no. of each type)
Each type of module of bus bar differential relay for Bus Bar protection with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Metrosil(Non-linear resistor) each type with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Inter-posing CT & PTs each type with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Mandatory spares for Sub-Stn Automation system:
Bay control unit with configuration software with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Ethernet Switch of each type with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Optical cable of longest length with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Testing and Maintenance for GIS/Relays:
SF6 Gas filling and evacuating & storage plant with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Portable Partial Discharge Monitoring for GIS(minimum 6 channels) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Portable SF6 gas leak Detector with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Portable SF6 gas quality analyzer- Online measurement of moisture (Dew point/PPM), purity, SO2, HF, CF4 & air content of SF6 gas with all lead and lifts complete as per specifications and direction of...
OD TB erection:
Metal encapsulated SF6 gas insulated Switchgear 220kV 50kA rating suitable for outdoor installation of modular design. The make of GIS shall be M/s. Siemens make.
Note: The proposed GI...
1) Relay & Protection Panels, SAS and LCC panel:-
220 kV Line -Type 2L (Annexure RPP1-Cable -SAS) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work...
b) Installation, integration, testing & commissioning of C&R panels with SAS supplied by a company for new bay extension with their existing Automation System.
Integration of C&R Panel to proposed SAS...
AC Distribution Box (outdoor):
AC Distribution Box single front type, 6 terminals, 1 I/c of 100A, MCCB 20kA+6 O/G MCB 16A+ 1 O/G of 100A, HRC fuse with all lead and lifts complete as per specification...
Copper Control cable:
PVC Insulated Copper Control Cable with lugs / ferrules (Refer annexure for details at the end of this schedule of quantities) :
2.5 Sq.mm 19 Core with all lead and lifts complet...
2.5 Sq.mm 14 Core with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
2.5 Sq.mm 10 Core with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
2.5 Sq.mm 4 Core with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
6 Sq.mm 4 Core with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
4 Sq.mm 4 Core with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
2Px0.5 Sq.mm screened cable for 4-20mA signal Transmission with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Communication Equipments:
Multi Function Transducer (MFT) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
8 Channel 220/110 V Opto Coupler with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Signal cable : Armoured Copper 10C x 0.5 Sq mm
multistrand with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
10C x 1.5 Sq mm multistrand, conforming to
KPTCL specification with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
3C x 4 Sq mm multistrand for AC input to UPS and
UPS to RTU, conforming to KPTCL specification with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
1C x 32 Sq mm multistrand for battery conforming
to KPTCL specification with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Current cable copper core 4Cx4sqmm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Voltage cable copper core 4Cx2.5sqmm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Earth Mat Formation: Quantities are provisioned approximately:
Grounding of equipment with 75x12 mm G.I. Flat and connecting equipment to the earthmat/ground pit. Each point of earthing with all forma...
Grounding of equipments by providing cast iron pipe of 100 mm ID 13mm thickness, 2.75mtrs long with 2 part clamp out of GI flat 50X6 mm continously welded around the pipe using cast iron welding elect...
Supplying and fixing 450mm dia x 450mm height 1.5" to 2" thick Hume pipe collars (non presessure type) for earth pits with all lead and lifts complete as per specifications and direction of Engineer ...
TB NRS Civil: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricadi...
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/w...
Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a 2 coat of approved pa...
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by r...
Disposal of surplus earth/ rock/ unwanted stuffs to the areas directed/notified areas of disposal point of the local bodies including all lead and lift charges, transportion, loading and unloading etc...
Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plaster...
Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plaster...
Providing and fixing SFRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fix...
Removal, stacking and respreading of existing jelly as per the directions of the engineer in charge of the work including all cost of labour,loading,unloding,transportation etc., complete and other it...
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipe...
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever nec...
Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R41...
Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C with all ...
Metal encapsulated SF6 gas insulated Switchgear 50kA rating suitable for indoor installation of modular design.
The make of GIS module shall be same as existing GIS module and interfaced ...
Local Control cubicle for GIS module, gas monitoring device, barriers pressure switches etc as required with all lead and lifts complete as per specifications and direction of Engineer in charge of th...
220kV, 3 phase, 2500A SF6 duct outside the GIS building including SF6 gas monitoring system for connecting GIS module to SF6/ Air bushing including support structure & Civil foundation.(Transformer Mo...
220kV 2500A, 50kA SF6/Air bushing for connecting GIS to AIS including support structure & Civil foundation with all lead and lifts complete as per specifications and direction of Engineer in charge of...
Capacitor voltage transformer :
245kV CVTs 4400Pf, of ratio 220kV/Square root3/110V/Square root3-110V/Square root3 with marshaling boxes, terminal connectors & support stool for erecting on standard s...
Surge Arresters: Surge Arresters with insulating base, surge monitor, terminal connectors & support stool for erecting on standard support structure etc., as per bid specifications.
216kV Class with ...
I. Control & Protection Panels : Simplex type SAS compatible:
220kV Line Type 2L (As per Annexure RPPI-SAS) with all lead and lifts complete as per specifications and direction of Engineer in charge o...
1.1kV Grade PVC Insulated armoured copper control cables of sizes with glands/lugs/ferrules , as per bid specification with all lead and lifts complete as per specifications and direction of Engineer ...
ii.4c x 6Sq.mm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
iii.4c x 2.5 Sq.mm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
iv.7c x 2.5 Sq.mm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
v.10c x 2.5 Sq.mm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
vi.14c x 2.5 Sq.mm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
vii.19c x 2.5Sq.mm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
viii. 2P x 0.5 Sqmm screened cable with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
ix. 4P x 0.5Sqmmm Screened cable with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
x. 8P x 0.5 Sqmmm screened cable with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
1.The bidder shall quote unit rates for power cable, co...
Rigid Bus with Taps::
Aluminium Tube, confirming to 6340wp of IS 5082, 1969, BS1600 Schedule 80 of following sizes with all lead and lifts complete as per specifications and direction of Engineer in c...
Bus Post Insulators:
220kV Class with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Bersimis ACSR conductor with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Insulator & Hardware:
220kV single suspension string insulator assembly with 15 Nos. Normal type disc insulators with all hardware accessories including arcing horn, suspension clamp set etc. suitable...
220kV single suspension string insulator assembly with 15 Nos. Normal type disc insulators with all hardware accessories including arcing horn, suspension clamp set etc. suitable for
a. Twin Bersimis...
220kV Clamps and Connectors:
Terminal connector for BPI to receive 4" IPS AL.Tube sliding type with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Terminal connector for SF6/Air bushing suitable to receive Twin Bersimis ACSR conductor with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
T Clamp (wedge type) suitable for Twin Bersimis ACSR on run and Twin Bersimis ACSR on tap with all lead and lifts complete as per specifications and direction of Engineer in charge of the work. Note: ...
T Clamp (wedge type) suitable for Twin Drake to Twin Bersimis ACSR with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Note: Considered quad Bersim...
Spacers for Twin Moose ACSR Conductor with 250mm spacing with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Communication Equipments: :
Multi Function Transducer (MFT) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
8 Channel 220/110 V Opto Coupler with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Signal cable : Armoured Copper 10C x 0.5 Sq mm
multistrand with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
10C x 1.5 Sq mm multistrand, conforming to
KPTCL specification with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
3C x 4 Sq mm multistrand for AC input to UPS and
UPS to RTU, conforming to KPTCL specification with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
1C x 32 Sq mm multistrand for battery conforming
to KPTCL specification with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Current cable copper core 4Cx4sqmm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Voltage cable copper core 4Cx2.5sqmm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Station Structures:
iii. 220kV station structure tower - 2T1.
vi. 220kV station structure beam - 2B2 with 14M bay width.
Tubular Type structures for:
Surge Arrester:
Voltage Transformers
Station Structures:
iii. 220kV station structure tower - 2T1.
vi. 220kV station structure beam - 2B2 with 14M bay width.
Tubular Type structures for:
Surge Arrester:
Voltage Transformers
Mandatory Spares:
For GIS Common Spares, Maintenance and Testing Tools:
SF6 Gas pressure relief devices of each type with all lead and lifts complete as per specifications and direction of Engineer i...
Pressure gauges (of each type) along with coupling device with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Rubber Gaskets, “o” Rings and seals for SF6 gas with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Molecular filter for SF6 gas with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Density Monitors for SF6 gas with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
All types of Control Valves for SF6 gas with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
SF6 gas with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
** of total gas requirement subject to min of 30Kgs.
220 / 66 kV Bushing for connection to GIS duct with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
SF6 CIRCUIT BREAKER: All spares shall be for 220KV and 66KV separately
a) 220 kV, Single ph., 2000A Circuit Breaker interrupting chamber complete with all necessary apparatus with all lead and lif...
Rubber gaskets, O' rings and seals with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Trip coils with resistor with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Closing coils with resistor with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Relays, Power contactors, push buttons, timers & MCB etc., with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Closing assembly/ valve with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Trip assembly/ valve with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Pressure switches with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Auxiliary switch assembly with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Operation Counter with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Rupture disc/diaphragm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Windoscope / Observing window with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
All types of coupling for SF6 gas(1 no. each type) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
ISOLATORS & E/SWITCH GIS:
a) 220 kV, Single ph., 1600A Disconnecting & maintenance earthing Switch internal parts, complete with all necessary gaskets, mounting hardware, etc., with all lead and lif...
a) Operating mechanism of 220kV, 1600A Disconnecting Switch, complete with all necessary connecting apparatus with all lead and lifts complete as per specifications and direction of Engineer in charge...
a) 220kV, 1600A, single phase high speed fault making Earthing switch, Internal parts complete with all necessary gaskets mounting hardware etc. with all lead and lifts complete as per specifications...
a) Operating mechanism of 220kV, 1600A, high speed fault making Earthing switch, complete with all necessary gaskets connecting apparatus with all lead and lifts complete as per specifications and di...
Limit switch & Aux. switches with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
CURRENT TRANSFORMER - GIS:
Complete CT 220 kV with terminal connector (1 no. of each rating) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Relay Panel Spares: SPARES FOR RELAY AND PROTECTION PANELS:
All type of Numerical relays with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Trip circuit supervision relay with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Self reset trip relay with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Hand reset trip relay with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Timer relay with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
DC supervision relays with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Flag relays with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Auxiliary relays with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Maintenance & Testing equipment:
Capacitance & Tan delta & oil resistivity measuring equipment with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Portable dissolved gas analyser with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Moisture measuring kit - KARL FISCHER type. with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Measuring & analyzing equipment for moisture & air content with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Micro ohm meter (1.0 micro-ohm to 199.99micro ohm) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Numerical relay testing kit with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Circuit Breaker operational analyzer-DCRM with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Online DC earth fault locator with built-in charger & rechargeable batteries with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Combined CT & VT analyzer with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
ID TB erection:
Metal encapsulated SF6 gas insulated Switchgear 50kA rating suitable for indoor installation of modular design.
The make of GIS module shall be same as existing GIS module and interfa...
220kV, 3 phase, 2500A SF6 duct outside the GIS building including SF6 gas monitoring system for connecting GIS module to SF6/ Air bushing including support structure & Civil foundation.(Transformer Mo...
220kV 2500A, 50kA SF6/Air bushing for connecting GIS to AIS including support structure & Civil foundation with all lead and lifts complete as per specifications and direction of Engineer in charge o...
Capacitor voltage transformer :
245kV CVTs 4400Pf, of ratio 220kV/Square root3/110V/Square root3-110V/Square root3 with marshaling boxes, terminal connectors & support stool for erecting on standard s...
Surge Arresters: Surge Arresters with insulating base, surge monitor, terminal connectors & support stool for erecting on standard support structure etc., as per bid specifications with all lead and l...
Control & Protection Panels : Simplex type SAS compatible:
220kV Line Type 2L (As per Annexure RPPI-SAS) with all lead and lifts complete as per specifications and direction of Engineer in charge of t...
b) Installation, integration, testing & commissioning of C&R panels with SAS supplied by a company for new bay extension with their existing Automation System
Integration of C&R Panel to proposed SAS...
1.1kV Grade PVC Insulated armoured copper control cables of sizes with glands/lugs/ferrules , as per bid specification with all lead and lifts complete as per specifications and direction of Engineer ...
ii. 4c x 6Sq.mm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
iii. 4c x 2.5 Sq.mm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
iv. 7c x 2.5 Sq.mm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
v. 10c x 2.5 Sq.mm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
vi. 14c x 2.5 Sq.mm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
vii. 19c x 2.5Sq.mm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
viii. 2P x 0.5 Sqmm screened cable with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
ix. 4P x 0.5Sqmmm Screened cable with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
x. 8P x 0.5 Sqmmm screened cable with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
1.The bidder shall quote unit rates for power cable, co...
Rigid Bus with Taps:
Aluminium Tube, confirming to 6340wp of IS 5082, 1969, BS1600 Schedule 80 of following sizes with all lead and lifts complete as per specifications and direction of Engineer in ch...
Bus Post Insulators: 220kV Class with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
a.Bersimis ACSR conductor :
Formation of main / cross bus with Bersimis conductor with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Communication Equipments:
Multi Function Transducer (MFT) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
8 Channel 220/110 V Opto Coupler with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Signal cable : Armoured Copper 10C x 0.5 Sq mm
multistrand with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
10C x 1.5 Sq mm multistrand, conforming to
KPTCL specification with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
3C x 4 Sq mm multistrand for AC input to UPS and
UPS to RTU, conforming to KPTCL specification with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
1C x 32 Sq mm multistrand for battery conforming
to KPTCL specification with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Current cable copper core 4Cx4sqmm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Voltage cable copper core 4Cx2.5sqmm with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Station Structures:
220kV station structure tower - 2T1.
220kV station structure beam - 2B2 with 14M bay width.
Tubular Type structures for:
Surge Arrester:
Voltage Transformers
220kV Class C...
Station Structures:
220kV station structure tower - 2T1.
220kV station structure beam - 2B2 with 14M bay width.
Tubular Type structures for:
Surge Arrester:
Voltage Transformers
220kV Class C...
Earth Mat Formation: Quantities are provisioned approximately:
Grounding of equipment with 75x12 mm G.I. Flat and connecting equipment to the earthmat/ground pit. Each point of earthing with all forma...
Grounding of equipments by providing cast iron pipe of 100 mm ID 13mm thickness, 2.75mtrs long with 2 part clamp out of GI flat 50X6 mm continously welded around the pipe using cast iron welding elect...
Supplying and fixing 450mm dia x 450mm height 1.5" to 2" thick Hume pipe collars (non presessure type) for earth pits with all lead and lifts complete as per specifications and direction of Engineer ...
TB ADI Civil: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricadi...
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/w...
Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a 2 coat of approved pa...
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by r...
Disposal of surplus earth/ rock/ unwanted stuffs to the areas directed/notified areas of disposal point of the local bodies including all lead and lift charges, transportion, loading and unloading etc...
Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plaster...
Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plaster...
Providing and fixing SFRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fix...
Removal,stacking and respreading of existing jelly as per the directions of the engineer in charge of the work including all cost of labour,loading,unloding,transportation etc., complete and other ite...
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipe...
66kV, EHV UG Cable:
66KV, 1000sqmm XLPE UG Cable 66KV (E) grade, 1 core, Circular, stranded, plain annealed Segmental compact type miliken copper condutor, conductor screen on extruded semi conducti...
Outdoor type cable end termination suitable for 66KV (E) 1 -core, 1000sqmm, Segmental compact type miliken copper conductor, XLPE, lead sheathed cable including PVC earthing cable with all lead and ...
66kV Link boxes, single phase outdoor structure mounting type with SVL/CCPU and PVC earthing cable with all lead and lifts complete as per specifications and direction of Engineer in charge of the wo...
Surge Arrestor: 60 kV class III, Heavy duty Metal oxide type, porcelain housing gapless type with surge counter with all lead and lifts complete as per specifications and direction of Engineer in char...
Terminal connectors to connect cable end termination to the Single ACSR Drake conductor with bolts & nuts and washers, with all lead and lifts complete as per specifications and direction of Engineer...
Fabrication and Supply of galvanised 110kV DC NBT (KPTCL Design) Transmission Line Towers:
Tower Type 'DD' Normal
Addl cross arm / 9th cross arm
Stubs for DD type with all lead and ...
Supply of Galvanised Bolts & Nuts for tower parts, extensions and stubs:
110kV DC NBT (KPTCL Design) Transmission Line Towers:
Tower Type 'DD' Normal
Auxiliary cross arm with all lead and ...
110kV CTT : Fabrication and supply of galvanised 110 kV Cable Terminating Tower (NBT) 110kV CTT - NBT type including stub DD+0 with all lead and lifts complete as per specifications and direction of E...
Supply of Galvanised Bolts,Nuts & washers etc., required for 110 kV Cable Terminating Tower (NBT) :
DD+0 with all lead and lifts complete as per specifications and direction of Engineer in charge of t...
Conductor Drake ACSR with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Earth wire: 7/3.15 ground conductor with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Hardware & Insulators :
66kV 90KN tension type composie polymer long rod insulators with sectional length 725mm with all lead and lifts complete as per specifications and direction of Engineer in char...
Single tension clamps with arcing horns with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Single suspension clamps with arcing horns with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Accessories for Drake ACSR conductor:
Vibration damper with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
C Type Wedge connector (T-Type) suitable for Drake to Drake ACSR with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
C Type Wedge connector (T-Type) suitable for Drake to Moose ACSR with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Repair sleeves suitable for Drake with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
MSC joint for Drake with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Hardware for Earthwire: P G Clamps suitable for Ground Conductor with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Single Tension clamps, suitable for Ground conductor with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
MSC joint for Ground conductor with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Repair sleeves for Ground conductor with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Tower Accessories :
Number Plates with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Danger Boards with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Circuit plate with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Phase plate (Set of 3 per tower) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Earth bond 450 mm long with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
OFC Cable & Accessories:
Unarmored Under Ground Fiber Optic Cable (48F DWSM) as per technical specifications with all lead and lifts complete as per specifications and direction of Engineer in charge ...
Poly Vinyl Lubricated Bond (PLB) HDPE OD 40mm with accessories with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
OFC end terminal (Line Interface unit LIU suitable for 48F) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Straight joint closure kit for OFC(48F) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Media converter with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Collars for PLB Pipe with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
66kV LILO erection:
Surveying of cable route, excavation trial holes as per field requirements, preparation of cable route profile drawings for cable laying, final route alignment, marking lines and g...
Check survey using their own equipment for 66kV plain terrain with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Conducting Drone survey of Transmission Lines for collection of data along with Aerial inspection of EHV Line coridor using LIDAR method for meaasurements of vertical, horizontal and ground clerances ...
Laying including Testing & Commissioning: Laying of 66KV single core, 1000sqmm XLPE Segmental compact type miliken Copper cable in trefoil, tapping , fixing pipes for drain and gate crossing as per d...
Handling & making of cables end termination for 66 KV power cables with all consuambles at site with all lead and lifts complete as per specifications and direction of Engineer in charge of the work...
Erection of single phase earth link boxes, both in S/s and on to the cable end termination structure connecting earth leads with all lugs, fixtures, clamps, bolts, and nuts with all lead and lifts com...
Supply and erection of earthing materials including CI pipe with suitable clamps, collor, earth lead cable, salt, charcol etc., and all necessar earth works etc with complete set.
Supplying & Providing 450mm dia 450mm height 1.5" to 2' thich hume pipe collar (non pressure type) for eatrth pits with all lead and lifts complete as per specifications and direction of Engineer in c...
Erection of 66kV Surge arrestors (60KV class III, Heavy duty) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
110kV Cable Treminating Tower:
Stub setting templates: Setting of stub templates and aligning dismantling and transportation of templates from one location to another location for 110 kV & Dwarf towe...
Tack welding of Bolts and Nuts (No of tower x 250) (Under Shut Down) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Riveting of tower bolt ends by heating using dry-Acetyleae gas and hammering to destroy threads so as to make the tower members theft proof (Bolts at nodal points only to be selected and revitted up t...
Erection of galvanised 110 kV Tower:
110kV CTT - NBT type DD plus 0 - 3 nos. & DD plus 3 - 01 no. with all lead and lifts complete as per specifications and direction of Engineer in charge of the work...
B&N for above with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Laying of 48 Fiber unarmoured Under Ground FO cable (48F DWSM)with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Survey & documentation with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Charges for conducting precommissioning tests as per IEC 60840, IS 7098 Part - III and successful commissioning of UG Transmission line with all lead and lifts complete as per specifications and dire...
Handling and making Normal straight joint closures for 48Fiber unarmoured Under Ground FO cable with all consumables at site with all lead and lifts complete as per specifications and direction of Eng...
Handling and making Terminal joints for 48Fiber unarmoured Under Ground FO cable with all consumables at site with all lead and lifts complete as per specifications and direction of Engineer in charge...
Stringing of Conductor: Drake ACSR with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Earth wire:7/3.15 ground conductor with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Number Plates with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Danger Boards with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Circuit plate with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Phase plate (Set of 3 per tower) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Supplying and fixing GI angle 450 x 450 mm 1Mtr length with cleats, bolts nuts as per specification and fixing above 0.5 mts length each at inner and outer surface of tower to facilitate running of b...
Supplying and fixing Barbed wire with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Grounding of towers including cost of 40 mm dia 2.5 mm thick, class 'C' G.I pipe of 3 m length as per spec, with 50X6 mm G.I flat 3 m long, salt charcoal, including excavation charges with all lead an...
Dismantling of existing 110KV DC NB Tower (DA plus 0 - 1 No. & DA plus 3 - 1 No.) with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Releasing & Restringing:
Releasing of the existing 66kV Coyote ACSR conductor with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Releasing of Existing Ground Wire in plain terrain with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Restringing of the existing 66kV Coyote ACSR conductor with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
Restringing of Existing Ground Wire in plain terrain with all lead and lifts complete as per specifications and direction of Engineer in charge of the work.
66kV LILO Civil: Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, stru...
Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bra...
Providing M-Sand : Supplying and filling in plinth, foundations / UG cable work with approved M-sand including watering, ramming, consolidating and dressing. The rate includes the cost of material, la...
Supplying and Providing pre cast RCC Protection Covers using M20 grade Concrete, steel of approved size/shape (as per the approved drawings) to be laid in UG cable works. The rate includes the cost of...
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5...
Removal of Unserviceable Soil with Disposal upto a suitable distance with all lead and lifts complete as per specification & direction of Engineer in charge of the work.
Providing and laying of warning tape / Caution tape / detector tape for HDPE pipes of 200 mm wide, 300 micron thick, blue in colour confoming to relevant ISS with latest amendments with appurtenances....
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite /trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant I...
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes...
Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/w...
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by r...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
BOM and Layout proposed 220kV AH.pdf
Design Document • 1.52 MB
400kV AN Hosahalli Layout.pdf
Design Document • 0.28 MB
Adinarayana Hosahalli Phase-2 KIADB Sub Station.pdf
Design Document • 2.79 MB
Bid Document.pdf
Tender Document • 1.37 MB
Survey 220 66 11KV ss.pdf
Design Document • 1.57 MB
220kV DB Pura Layout.pdf
Design Document • 0.37 MB
Technical Specifications- new.zip
Others - Technical Specifications • 45.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .