Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC | L1 | Accepted-AOC AOC23 | |
| 2 | L2₹31.1 L+₹2.5 L (8.84%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹31.9 L+₹3.3 L (11.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹40.7 L+₹12.1 L (42.2%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | RONKI RAM AND COMPANY L1 | Esha Engineers L4 | R. P. Suppliers and Construction Co. L3 | M/s Seerat Enterprises L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.50 metre wide and not exc 1.50 metre deep in soft/ loose soil for laying of pipe line and getting out complete all as specified and directed. | 470 | Cubic Metre | 80 ₹37,600 Lowest | 200 ₹94,000 | 273 ₹1,28,310 | 80 ₹37,600 Lowest |
| 2.00 | Excavation in trenches exc 1.50 metre wide and not exc 3.0 metre deep in soft/ loose soil for laying of pipe line and getting out complete all as specified and directed. | 47 | Cubic Metre | 80 ₹3,760 Lowest | 300 ₹14,100 | 386 ₹18,142 | 120 ₹5,640 |
| 3.00 | Returning filling in, including spreading leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. | 423 | Cubic Metre | 20 ₹8,460 Lowest | 40 ₹16,920 | 100 ₹42,300 | 40 ₹16,920 |
| 4.00 | Removal of excavated soil surplus to the requirement to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed. | 47 | Cubic Metre | 10 ₹470 Lowest | 40 ₹1,880 | 228 ₹10,716 | 20 ₹940 |
| 5.00 | Supply and laying in trenches ductile iron pipe of 350mm bore, S/S,Class K-9 , with rubber gasket (tyton) joints, nut, bolts & washers ISI marked including taking up/down CI/DI pipes with connection and connected fittings/accessories complete all as specified and directed. | 11 | Running Metre | 4,000 ₹44,000 | 4,000 ₹44,000 | 4,000 ₹44,000 | 3,800 ₹41,800 Lowest |
| 6.00 | All as per Srl Item No. 5.00 here in before but of size 300 mm bore. | 11 | Running Metre | 3,400 ₹37,400 | 3,800 ₹41,800 | 3,000 ₹33,000 Lowest | 3,000 ₹33,000 Lowest |
| 7.00 | All as per Srl Item No. 5.00 here in before but of size 250 mm bore. | 55 | Running Metre | 2,500 ₹1,37,500 Lowest | 3,200 ₹1,76,000 | 2,800 ₹1,54,000 | 2,500 ₹1,37,500 Lowest |
| 8.00 | All as per Srl Item No. 5.00 here in before but of size 200 mm bore. | 33 | Running Metre | 2,000 ₹66,000 | 2,000 ₹66,000 | 1,700 ₹56,100 Lowest | 2,000 ₹66,000 |
| 9.00 | All as per Srl Item No. 5.00 here in before but of size 150 mm bore. | 44 | Running Metre | 1,400 ₹61,600 Lowest | 1,800 ₹79,200 | 1,500 ₹66,000 | 1,400 ₹61,600 Lowest |
| 10.00 | All as per Srl Item No. 5.00 here in before but of size 100 mm bore. | 55 | Running Metre | 1,100 ₹60,500 | 1,400 ₹77,000 | 1,000 ₹55,000 | 900 ₹49,500 Lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
21 May 2026, 6:00 pmClosed
GE UTILITY AMBALA
GE UTILITY AMBALA CANTT 133001
COMPREHENSIVE MAINT REPAIR REPLACEMENT ATTENDING BREAKDOWN AND ALLIED WORKS FOR GI CI AND DI WATER PIPE LINES FOR EXTERNAL WATER SUPPLY DISTRIBUTION SYSTEM AT SECTOR C UNDER GE U AMBALA CANTT
2026_MES_762714_1
CA NO GE U AMB 23 OF 2026-27
Open Tender
Civil Works
Item Rate
240 days
GE UTILITY AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹98,000
9 Jul 2026
29 Apr 2026
23 May 2026
29 Apr 2026
21 May 2026
14 May 2026
29 Apr 2026 - 6 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exc 1.50 metre wide and not exc 1.50 metre deep in soft/ loose soil for laying of pipe line and getting out complete all as specified and directed. | 470 | Cubic Metre | - | - |
| 2 | Excavation in trenches exc 1.50 metre wide and not exc 3.0 metre deep in soft/ loose soil for laying of pipe line and getting out complete all as specified and directed. | 47 | Cubic Metre | - | - |
| 3 | Returning filling in, including spreading leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. | 423 | Cubic Metre | - | - |
| 4 | Removal of excavated soil surplus to the requirement to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed. | 47 | Cubic Metre | - | - |
| 5 | Supply and laying in trenches ductile iron pipe of 350mm bore, S/S,Class K-9 , with rubber gasket (tyton) joints, nut, bolts & washers ISI marked including taking up/down CI/DI pipes with connection and connected fittings/accessories complete all as specified and directed. | 11 | Running Metre | - | - |
| 6 | All as per Srl Item No. 5.00 here in before but of size 300 mm bore. | 11 | Running Metre | - | - |
| 7 | All as per Srl Item No. 5.00 here in before but of size 250 mm bore. | 55 | Running Metre | - | - |
| 8 | All as per Srl Item No. 5.00 here in before but of size 200 mm bore. | 33 | Running Metre | - | - |
| 9 | All as per Srl Item No. 5.00 here in before but of size 150 mm bore. | 44 | Running Metre | - | - |
| 10 | All as per Srl Item No. 5.00 here in before but of size 100 mm bore. | 55 | Running Metre | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.82 MB
BOQ_854364.xls
BOQ • 0.28 MB
Tender.pdf
Tender Documents • 0.72 MB
AMENDMENT23.pdf
PDF • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .