| 1 | L1₹2.9 CrAdmitted-Finance | ₹2.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.1 Cr+₹25.7 L (8.89%)Admitted-Finance | ₹3.1 Cr+₹25.7 L (8.89%) | L2 | Admitted-Finance |
| 3 | L3₹3.2 Cr+₹33.1 L (11.5%)Admitted-Finance 14 474A 14 474B 14 474C 14 474D BROTHERS ARCADE AMBALAMEDU P O OPP SNDP MANDIR KUZHIKKADU ERNAKULAM KERALA 682303 | ERNAKULAM | KERALA | 682303 | ₹3.2 Cr+₹33.1 L (11.5%) | L3 | Admitted-Finance |
| 4 | L4₹3.2 Cr+₹33.9 L (11.7%)Admitted-Finance | ₹3.2 Cr+₹33.9 L (11.7%) | L4 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | Rejected-Technical Party failed to provide documents in line with PQ crtiteria. |
| Sl No | Description | Qty | Unit | Malayil Builders Pvt Ltd L4 | MBM ENGG WORKS L2 | KK CONSTRUCTIONS L1 | BREC Projects Private Limited L3 |
|---|---|---|---|---|---|---|---|
| 1.00CONSTRUCTION OF NEW HEAVY EQUIPMENT BUILDING FOR PREPARATORY CIVIL WORKS FOR THE CONSTRUCTION OF NEW 10000 MT AMMONIA STORAGE TANK AND ALLIED STRUCTURES AT FACT CD. | |||||||
| 1.00 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1m above ground level and removal of rubbish and cleared items to locations pointed out by Engineer in-charge (EiC), with in a lead of 50m. | 450 | M2 | 11,250 ₹13,275 | 2,250 ₹2,655 Lowest | 27,000 ₹31,860 | 9,900 ₹11,682 |
| 1.00 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish, with in a lead of 50m at locations pointed out by Engineer in-charge in all kinds of soil | 45 | M2 | 900 ₹1,062 Lowest | 1,350 ₹1,593 | 6,750 ₹7,965 | 2,925 ₹3,451.5 |
| 1.00 | Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material - Beyond 60 cm girth upto and including 120 cm girth | 3 | NO | 7,500 ₹8,850 | 4,800 ₹5,664 | 7,500 ₹8,850 | 3,450 ₹4,071 Lowest |
| 1.00 | Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material - Beyond 120 cm girth upto and including 240 cm girth | 3 | NO | 9,000 ₹10,620 | 6,900 ₹8,142 | 22,500 ₹26,550 | 3,750 ₹4,425 Lowest |
| 1.00 | Disposal of moorum / building rubbish / malba / similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading in areas with in a lead of 10km in FACT CD premises in for all lifts, complete as per directions of EiC. | 50 | M3 | 15,000 ₹17,700 | 23,000 ₹27,140 | 25,000 ₹29,500 | 13,750 ₹16,225 Lowest |
| 1.01 | Charges for conveying the surplus earth to places approximately 10 kms away and dumping at low lying places as directed by the Engineer in-charge. | 2,690 | M3 | 21,52,000 ₹25,39,360 | 7,53,200 ₹8,88,776 | 4,43,850 ₹5,23,743 Lowest | 9,14,600 ₹10,79,228 |
| 1.01 | Supplying and stacking good earth brought from outside, at locations pointed out by the engineer in-charge | 280 | M3 | 3,64,000 ₹4,29,520 | 3,36,000 ₹3,96,480 Lowest | 3,50,000 ₹4,13,000 | 4,25,600 ₹5,02,208 |
| 1.01 | Earth work in excavation in open areas (exceeding 1.5m in width as well as 10sqm on plan) by mechanical means (Hydraulic excavator) / manual means in all kinds of soil, for lifts up to 1.5m from existing ground level, including getting out the excavated soil and disposal with in a lead of 50m as directed by the Engineer in-charge. | 2,598 | M3 | 6,49,500 ₹7,66,410 | 5,97,540 ₹7,05,097.2 | 4,54,650 ₹5,36,487 Lowest | 6,36,510 ₹7,51,081.8 |
| 1.01 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches in all kinds of soil, including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soil up to a lead of 50m, as directed by the Engineer in-charge . The rates shall include bailing out water, and keeping the sides from collapsing using necessary timbering, planking, and shoring. | 542 | M3 | 1,62,600 ₹1,91,868 Lowest | 1,73,440 ₹2,04,659.2 | 1,97,830 ₹2,33,439.4 | 1,73,440 ₹2,04,659.2 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
9 Aug 2022, 2:00 pmClosed
SM(MAT)-C
CONTRACTS DEPT CORPORATE MATERIALS FACT-UDYOGAMANDAL
CONSTRUCTION OF NEW HEAVY EQUIPMENT BUILDING AT FACT CD, AMBALAMEDU as per tender conditions.
2022_FACT_696756_1
04031/2022-2023/E25720
Open Tender
Miscellaneous Works
Item Rate
180 days
FACT CD, AMBALAMEDU
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹1 L
Yes
13 Oct 2022
24 Jun 2022
9 Aug 2022
24 Jun 2022
9 Aug 2022
24 Jun 2022
CONSTRUCTION OF NEW HEAVY EQUIPMENT BUILDING FOR PREPARATORY CIVIL WORKS FOR THE CONSTRUCTION OF NEW 10000 MT AMMONIA STORAGE TANK AND ALLIED STRUCTURES AT FACT CD.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1m above ground level and removal of rubbish and cleared items to locations pointed out by Engineer in-charge (EiC), with in a lead of 50m.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish, with in a lead of 50m at locations pointed out by Engineer in-charge in all kinds of soil
Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material - Beyond 60 cm girth upto and including 120 cm girth
Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material - Beyond 120 cm girth upto and including 240 cm girth
Disposal of moorum / building rubbish / malba / similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading in areas with in a lead of 10km in FACT CD premises in for all lifts, complete as per directions of EiC.
Charges for conveying the surplus earth to places approximately 10 kms away and dumping at low lying places as directed by the Engineer in-charge.
Supplying and stacking good earth brought from outside, at locations pointed out by the engineer in-charge
Earth work in excavation in open areas (exceeding 1.5m in width as well as 10sqm on plan) by mechanical means (Hydraulic excavator) / manual means in all kinds of soil, for lifts up to 1.5m from existing ground level, including getting out the excavated soil and disposal with in a lead of 50m as directed by the Engineer in-charge.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches in all kinds of soil, including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soil up to a lead of 50m, as directed by the Engineer in-charge . The rates shall include bailing out water, and keeping the sides from collapsing using necessary timbering, planking, and shoring.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, for lead up to 50m and lift up to 1.5m.
Supplying, diluting, and injecting the ground with Chlorpyriphos/Lindane E.C. 20% with 1% concentration at 1 litre per holes of 300mm depth dug 1m apart at both directions, covering the area under construction.
Providing hard core layer of required thickness using 40mm nominal size graded hard granite broken stones after compacting the underlying soil, spreading and levelling the stones and then spreading a layer of 6mm downgraded crushed aggregates on top of the broken metal layer and it shall be watered in order to force the crushed fine aggregates into the void spaces of the broken stone and repeat the process till all the voids are filled with crushed fine aggregates right up to the edges of hard core layer, including cost of all materials and labour charges etc, complete.
Providing and laying plain cement concrete work in 1:4:8 mix (1 cement: 4 coarse river sand/manufactured sand: 8 40mm nominal size graded hard granite broken stones) including all charges for mixing concrete, laying, consolidating, curing, cost for bailing out of water, oil, liquid mud etc. from all sources in excavated pits, trenches, etc. complete at all levels as per standard specifications but excluding the cost of shuttering, and as directed by the Engineer in-charge for foundation / levelling course etc.
Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in-charge. (Note: - Cement content considered in this item is @ 340 kg/cum. Excess cement used as per design mix is payable separately) – for all works below plinth level
Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in-charge. (Note: - Cement content considered in this item is @ 340 kg/cum. Excess cement used as per design mix is payable separately) – for all works above plinth level
Reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) work at all levels, excluding cost of centering, shuttering, finishing and reinforcement & including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in-charge.
Reinforced cement concrete work of M25 grade for precast cover slab using Portland pozzolana cement containing more than 25% of fly ash, river sand / manufactured sand conforming to IS 383 and 20mm nominal size graded hard granite broken stones including all charges for designing the mix, weigh batching, including installation of batching plant at the designated location in the site premises or arranging RMC, mixing concrete, cost of adding concrete admixtures as required, transporting, formwork, laying, vibrating, consolidating, curing with minimal use of potable water subject to provision of IS 456, handling, transporting, loading, unloading, keeping and fixing in position, at all levels etc., complete but excluding cost of providing reinforcements. (Exposed surfaces of pre-cast elements shall have good finish with no blemish or mark on the finished surfaces) NOTE- (1) Minimum Cement content shall be @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. (2) Fly ash conforming to grade I of IS 3812 (Part-1) only be used as part replacement of OPC as per IS: 456. Uniform blending with cement to be ensured in accordance with clauses 5.2 and 5.2.1 of IS:456 - in the items of BMC and RMC -for cover slabs (75mm to 100mm thick) on drain.
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Providing form work to cement concrete and RCC works with necessary plywood / steel sheet, steel joists, runners, struts, posts etc with adjustable spans and telescopic posts, wooden planks etc. including removal after completion /curing at all levels for foundation footings, bases of columns and walls and for mass concrete with straight sides.
Providing form work to cement concrete and RCC works with necessary plywood / steel sheet, steel joists, runners, struts, posts etc with adjustable spans and telescopic posts, wooden planks etc. including removal after completion /curing at all levels for walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Providing form work to cement concrete and RCC works with necessary plywood / steel sheet, steel joists, runners, struts, posts etc with adjustable spans and telescopic posts, wooden planks etc. including removal after completion /curing at all levels for Suspended floors, roofs, landings, balconies and access platform, weather shades, chajja etc. including side shuttering. Rate to include for shuttering at all heights.
Providing form work to cement concrete and RCC works with necessary plywood / steel sheet, steel joists, runners, struts, posts etc with adjustable spans and telescopic posts, wooden planks etc. including removal after completion /curing at all levels for Lintels, beams, plinth beams, girders, bressumers and cantilevers. Rate to include for shuttering at all heights.
Providing form work to cement concrete and RCC works with necessary plywood / steel sheet, steel joists, runners, struts, posts etc with adjustable spans and telescopic posts, wooden planks etc. including removal after completion /curing at all levels for Columns, Pillars, Piers, Abutments, Posts and Struts. Rate to include for shuttering at all heights.
Supplying, fabricating, conveying, and fixing reinforcement to RCC works at all levels with high strength deformed bars of Fe500D grade Thermo Mechanically Treated (TMT) bars conforming to IS 1786 including all charges for uncoiling and straightening rods, cutting rods, bending cold, placing in position, and supplying & tying with black annealed tying wire of 16 gauge, etc. complete.
Providing and laying factory made Precast concrete solid blocks of 200 mm thickness of grade M10 from approved manufacturer in foundation and plinth in cement mortar 1:6
Providing and laying autoclaved aerated cement blocks masonry with 230/200/100 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. All AAC blocks used should have at least 40% of fly ash content by volume and min crushing strength of 3N/mm2 . The horizontal and vertical joint thickness should be approximately 3 mm. Masonry work shall strictly be carried out as per IS 6041 including cost of all materials and labour.(The payment of RCC band and reinforcement shall be made for seperately).
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. All AAC blocks used should have at least 40% of fly ash content by volume and min crushing strength of 3N/mm2 . The horizontal and vertical joint thickness should be approximately 3 mm. Masonry work shall strictly be carried out as per IS 6041 including cost of all materials and labour.
Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure At all levels in cement mortar 1:6 (1 cement : 6 coarse sand) :With Modular bricks
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone - III): 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Plastering with cement mortar 1:4, 15mm thick floated hard and trowelled smooth
Plastering with cement mortar 1:3, 6mm thick floated hard and trowelled smooth, for plastering over RCC works.
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litres / 10sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and thoroughly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer in-charge.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface
Painting with two coats of premium weather proof acrylic / plastic emulsion paint of exterior grade on new surfaces over a coat of cement primer (paid separately) including applying additional coats wherever required to achieve even shade and colour at all heights including cost of all labour, materials and scaffolding.
Painting with two coats of premium acrylic / plastic emulsion paint of interior grade on new surfaces over a coat of cement primer (paid separately) including applying additional coats wherever required to achieve even shade and colour at all heights including cost of all labour, materials and scaffolding.
Finishing concrete surface to polished finish (matt finish) by grinding, application of stains, densifier, honing, polishing etc as furnished by the manufacturer.
Providing and laying vitrified floor tiles in (min 8 mm thickness) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete - 1000 mm x 1000 mm size
Providing and laying anti skid Ceramic floor tiles in bathroom areas (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make and colours laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., 300x300mm or or nearest available size having minimum thickness of 8mm, with water absorption less than 0.08%
Providing and fixing 1st quality ceramic glazed wall tiles of size 300x450, conforming to IS:15622 with a minimum thickness of 8mm, of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing 18 mm thick gang saw cut, mirror polished, pre-moulded and pre-polished, machine cut granite slabs for vanity counters, window sills and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including cutting holes for sinks or handrails, rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing. - 30 mm thick plain PVC door shutters. Rate shall also include Providing and fixing PVC rigid foam sheet 1 mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive.
Providing and fixing polyester powder coated aluminium work in frame and shutters for doors, windows, ventilators, and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required diameter and size, including necessary filling up the gaps at junctions with silicone sealants to prevent water ingress i.e., at top, bottom, and sides. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / panelling, made tight with EPDM rubber / neoprene gaskets and, C.P. brass / stainless steel screws, hinges for shutters and all other necessary fixtures, including aluminium handles and bolts all complete as per architectural drawings and the directions of Engineer in-charge. (Glazing / panelling to be paid for separately). Powder coating shall be of ivory white colour with a minimum thickness of 50 micron.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10 kg/ sqm)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8.0 mm thickness (weight not less than 20 kg/ sqm)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With frosted glass panes of 4.0 mm thickness (weight not less than 10 kg/ sqm)
Supplying, fabricating and fixing MS grills to openings for windows / ventilators with rawl plugs screws etc. with MS square or round bars, MS flats, etc. as per design & drawings, including scraping and cleaning by power tools etc., and painting with two coats red oxide zinc chromate primer ( one shop coat and one coat after fixing) including cost of all materials and labour charges as directed by the Engineer in-Charge.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, ball bearings, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters and painting with two coats of synthetic enamel of approved shade over two coats of red oxide zinc chromate primer.- 80x1.25mm M.S. laths with 1.25mm thick top cover.
Providing and fixing 12 mm thick prelaminated particle board with decorative lamination on both sides, flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer in-charge.
Supplying, conveying fabrication and erection of MS single section memberssuch as channels, guard rail, MS angle hand rails verticals, etc. withfixtures such as end stops, clamps, bolts and nuts etc. including chargesfor cutting, splicing, drilling holes as required, fixing to lines andlevels and cleaning thoroughly with power tools and painting with two coats of synthetic enamel of approved shade over two coats of red oxide zinc chromate primer.
Supply, fabrication and erection of structural steel work in built up trussesbolted or welded at all levels with MS angles, channels, tees, flats, RSJs,rods, pipes, hollow rectangular sections and plates for roof trusses,purlins, cladding,gratings, runners etc. including cutting, welding, hoisting, erectingin position with necessary MS bolts including preparation of surface bygrit/shot blasting at all heights including hire of plants and equipments,labour and costs of grits, shots. After grit/shot blasting the surface shallexhibit almost clean white metal and shall have surface finish of Sa 2 ½ asper IS 9954. (Mill scale, rust & foreign matter shall be removed to the extentthat only traces remaining are slight stains in the form of spots or strip)The rate shall include erecting necessary scaffolding works wherever requiredand covering working area during blast cleaning with tarpaulin of goodquality to prevent spreading of dust, paint to the nearby operating areas and painting with two coats of synthetic enamel of approved shade over two coats of red oxide zinc chromate primer.
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete and painting with two coats of synthetic enamel of approved shade over two coats of red oxide zinc chromate primer.
Supplying, Conveying, fabricating and fixing MS inserts of all types fabricated out of MS plates, angles, channels, flats, rods, fabricated pieces, etc. . in RCC/ masonry works at all levels including all charges for cutting, welding, fixing to lines and levels and painting with two coats of synthetic enamel of approved shade over two coats of red oxide zinc chromate primer.
Supplying and fixing pultruded GRP heavy duty hand railing-side mounted design made of Isopthalic polyester resin containing glass fibre content not less than 60% and having fire retardant characteristics meeting ASTM E-84 flame spread <20 (type test) for a height of 1 mtr with 50 mm square GRP pultruded pipe post of 5 mm thickness at 1.50 mtr spacing with pre drilled holes, with 67mm Curved U shape top rail , mid rail and Kick Plate of 80mm wide Half Round shape with extended Flange design of colour yellow with all required stainless steel fasteners, clamps , specials, mounting hardware for fixing post etc complete at all levels as per manufactures specifications.GRP materials shall conform IS 14887 for UV resistance meeting 500 accelerated weathering test with Tensile and flexural strength not reducing more than 5% after exposure. The Hand Rail must be able to withstand 70 Kg concentrated load at mid span without any failure or crack.
Providing high impact Polypropylene reinforced cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required.
Providing and fixing ridges and hips inhigh impact Polypropylene reinforced cement with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete - Corrugated serrated adjustable ridges
Supplying & fixing of 4 mm thick FRP Gutter to be fabricated using two coats of isopthalic grade UV stablized Gel coat as top coating giving glossy smooth surface on the top to take the extreme weather and temprature followed by polyester isopthalic exterior grade UV stablized resin to form tough laminate with extra reinforcement of MS Strip of size 25x3 mm at a distance of 1000 mm c/c starting from one end, embedded along the outer periphery of gutter & anchored into the last purlin/plate properly .
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in RCC slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm size.
Providing and fixing at all levels 18 mm thick UPVC (Multiwud or equiv) board , edges rounded and polished of size 75x 50 cm deep fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the board in the chase with epoxy grout with teak wood plug screwed with brass screw and finished by cement concrete 1 :2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size ) as per direction of Engineer - in charge and finished smooth.
Providing and fixing ivory / cream colour vitreous china pedestal type water closet (European type W.C. pan – large size) with seat and lid, 10 litre low level ivory/cream coloured P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required with ISI marked ivory / cream colour solid plastic seat and lid
Providing and fixing ivory / cream colour vitreous china semi-recessed / semi-counter sunk wash basin of size 600x450mm (or nearest higher size) seated into the recess in the counter, one 15 mm CP brass pillar tap (quarter turn) of approved make and quality, 32 mm CP brass waste of standard pattern, other necessary fittings, including painting of fittings and brackets, cutting, and making good the walls etc. wherever required
Providing and fixing 15 mm nominal bore CP bib cock - short body (quarter turn) of approved make and quality having length not less than 115mm with cover plates for fixing into plumbing line already laid in the wall.
Providing and fixing 15 mm nominal bore CP bib cock - long body (quarter turn) of approved make and quality having length not less than 165mm with cover plates for fixing into plumbing line already laid in the wall.
Providing and fixing CP soap dish holder of approved make and quality having length not less than 150mm and breadth not less than 100mm with fitting arrangements like screws and wall plugs for fixing on the toilet wall.
Providing and fixing 600mm long CP towel rail of approved make and quality with brackets fixed to toilet walls with CP brass screws and rawl plugs with sufficient length and size to hold the brackets firmly to the wall.
Providing and fixing cloth hook of stainless steel of approved make, having length not less than 300mm having six hooks, fixed to wall with rawl plug and ss screws as per the direction of engineer in-charge
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter
Providing and fixing CP health faucet with hose and holder of approved make and having hose length not less than 1000mm with fitting arrangements like screws and wall plugs for fixing on the toilet wall.
Providing and fixing PVC Floor multi-trap with 50mm waste outlet for draining wastewater from toilet, with CP cover, fixed in alignment with the floor tile and sides sealed for proper drainage of water, as per directions of Engineer in-charge.
Providing and fixing PVC Floor drains with 50mm waste outlet for draining wastewater from toilet, with CP cover, fixed in alignment with the floor tile and sides sealed for proper drainage of water, as per directions of Engineer in-charge.
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 - 15 mm nominal bore for urinals
Providing and fixing 15mm nominal bore CP angle cock of approved quality and make weighing not less than 150 gms with fitting arrangements like wall cover plates screws and wall plugs for fixing on the toilet wall.
Providing and fixing 15 mm nominal bore PTMT bib cock - short body (half turn) of approved make and quality having length not less than 115mm with PTMT cover plates for fixing into plumbing line already laid in the wall.
Providing and fixing mirror of superior glass (of approved quality) and of rectangular shape and size 600x450 or nearest higher size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing to be hung on walls.
Providing and fixing CPVC ball valve of 25mm nominal bore to CPVC pipes in external exposed works
Providing and fixing CPVC ball valve of 20mm nominal bore to CPVC pipes in external exposed works
Providing and fixing PTMT float valve of approved quality, colour and make complete with fittings - Epoxy coated aluminium rod of length not less than 250mm threaded at both ends, with nuts and rubber washers and PVC ball.
Providing and fixing 25 mm nominal outer dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold-water supply including all CPVC plain & brass threaded fittings and fixing the pipe on walls with clamps at 1m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement & testing of joints complete as per direction of Engineer in-charge.
Providing and fixing 20mm nominal outer diameter Chlorinated Polyvinyl Chloride (CPVC) pipes, in concealed work having thermal stability for hot & cold-water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in-charge.
Providing and fixing soil, waste and vent pipes (Type B, pasting type conforming to IS 13592) of 110mm dia, for removal of waste including all fixtures like bends, elbows, etc. as required including cutting walls and excavating trenches and jointing pipes and fittings with PVC solvent cements and making good the same and testing of joints complete as per the directions of Engineer in-charge.
Providing and fixing soil, waste and vent pipes (Type B, pasting type, conforming to IS 13592) of 50mm dia, for removal of waste including all fixtures like bends, elbows, etc. as required including cutting walls and excavating trenches and jointing pipes and fittings with PVC solvent cements and making good the same and testing of joints complete as per the directions of Engineer in-charge.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank having 3-layer wall thickness, ISI marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet, and overflow pipes but without fittings and the base support for tank. (Blue colour)
Supply and installation of prefabricated ferrocement septic tank with soak pit from approved manufacturers including excavation, placing tank in position, plumbing works, backfilling, and levelling the ground, placing manhole covers and vent pipes etc. complete including all materials and labour, to meet a user capacity of 10 users. The scheme shall be with the approval of Engineer in-charge
Construction of gully trap with SWR P-type pipe fittings (pasting type) housed in brick masonry chamber constructed with common burnt clay non-modular bricks of class 5.0 on 1:1.5:3, grade concrete slab, both sides plastered with CM 1:4 , and covered with watertight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per approved design, all works complete including supply of all materials and labour.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes - 110 mm dia. Rate includes Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms.
Supplying and fixing pultruded GRP gratings made of Isophthalic polyester resin containing glass fibre content not less than 60% and having fire retardant characteristics, of 38mm height with I bar spacing not exceeding 40mm c/c and crossbars not exceeding 90 mm c/c, suitable for imposed load of 500kg/sqm of colour grey and designed for a max support span of 1300mm over cable trenches / drains / stairs with bonded grit antiskid surface including fixing to the existing structural steel frames / RCC walls by means of SS hold down clamps, locking arrangement etc. For step ladders, gratings have to be fabricated as per site measurement and shall be rigidly fixed to the existing structural by suitable locking arrangement. 2 Piece locking system of size 700 wide (I-bar) x 1mtr (Cross Rod) Length. The GRP material shall be fire retardant meeting ASTM E84 Class A with Flame Spread less than or equal to 25 & Smoke Density ±200 and UV resistant meeting ASTM G154 with flexural strength not reducing by more than 7% on accelerated UV radiation exposure
Supplying and fixing chemical anchor bolts of HILTI or equivalent etc for anchoring the structural members to existing concrete column as per manufactures specification. etc. complete to lines and levels at all levels with 16mm dia stainless steel bolts (HIT-V rod or equivalent) fixed with Re500 V4 adhesive of HILTI or equivalent
Supply of 415V, 32A, 3 Ph & N, 6WAY Lighting Distribution Board with one number 32A, 4 pole RCBO (30mA) as incomer and 11 Nos 10A and 7 Nos 16A Single Pole MCBs as out going feeders. The DB shall have separate buses for phases, neutral and earth. The DB shall be double door type and suitable for conduit entry for outgoing and cable entry for incoming. Cable adaptor box also shall be provided for incoming and outgoing cable/ wires (All MCBs shall be of C curve and 10 kA short circuit capacity. DBs shall conform to IS 13032 and Bus bar rating shall be 100A minimum). The scope shall also include the cost of termination of incoming wires including supply of lugs. The earth bus shall be suitable for taking individual earth leads for each circuit. The DB shall be suitable for flush mounting on a wall unless otherwise indicated in the layout drawing. The enclosure shall have IP43 protection. The gaskets used if any, shall be of neoprene only. Spare slots provided for MCB mounting if any shall be properly blanked. Make of DB shall be: LEGRAND/ HAVELLS/ INDOASIAN/ STANDARD ELECTRICALS/ C&S
Erection of 415V, 32A, 3 Ph & N, 6WAY Lighting Distribution Board with one number 32A, 4 pole RCBO (30mA) as incomer and 11 Nos 10A and 7 Nos 16A Single Pole MCBs as out going feeders. The DB shall have separate buses for phases, neutral and earth. The DB shall be double door type and suitable for conduit entry for outgoing and cable entry for incoming. Cable adaptor box also shall be provided for incoming and outgoing cable/ wires (All MCBs shall be of C curve and 10 kA short circuit capacity. DBs shall conform to IS 13032 and Bus bar rating shall be 100A minimum). The scope shall also include the cost of termination of incoming wires including supply of lugs. The earth bus shall be suitable for taking individual earth leads for each circuit. The DB shall be suitable for flush mounting on a wall unless otherwise indicated in the layout drawing. The enclosure shall have IP43 protection. The gaskets used if any, shall be of neoprene only. Spare slots provided for MCB mounting if any shall be properly blanked. Make of DB shall be: LEGRAND/ HAVELLS/ INDOASIAN/ STANDARD ELECTRICALS/ C&S
Supply of concealed conduit wiring for light point / exhaust fan with 1.5Sq.mm FRLSH PVC insulated stranded single core copper conductor cable through 20mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark clamped in wall, ceiling or column including supply and fixing of 3Plate ceiling rose in 3x3 PVC Box with UPVC cover in wall, 1No 6A modular switch (LEGRAND 6755 01 or equivalent) modular plate in suitable type box concealed in wall and earthing with 1.5Sq.mm insulated copper conductor etc. including supply of all fixing materials and accessories and interconnections complete as required. Refer Electrical layout drawings attached with this document. Also refer sl no. 2.0 of Annexure for further requirement.
Erection of concealed conduit wiring for light point / exhaust fan with 1.5Sq.mm FRLSH PVC insulated stranded single core copper conductor cable through 20mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark clamped in wall, ceiling or column including supply and fixing of 3Plate ceiling rose in 3x3 PVC Box with UPVC cover in wall, 1No 6A modular switch (LEGRAND 6755 01 or equivalent) modular plate in suitable type box concealed in wall and earthing with 1.5Sq.mm insulated copper conductor etc. including supply of all fixing materials and accessories and interconnections complete as required. Refer Electrical layout drawings attached with this document. Also refer sl no. 2.0 of Annexure for further requirement.
Supply for group controlled light points (from one light point to another light point), same as Sl No. 3 but without control switch. Supply of items from control switch to first light point is covered in item No.3. Refer Annexure for further requirement.
Wiring for group controlled light points (from one light point to another light point), same as Sl No. 4 but without control switch. Wiring from control switch to first light point is covered in item No.4. Refer Annexure for further requirement.
Supply for ceiling fan point with 1.5 Sq.mm FRLSH PVC insulated stranded single core copper conductor cable through 20mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark clamped in wall, ceiling or column including supply and fixing of 3Plate ceiling rose in junction box concealed in ceiling, 1No 6A modular switch (LEGRAND 675501 or equivalent) modular plate with regulator (Legrand 675530 or equivalent) in suitable type box concealed in wall and earthing with 1.5 Sq.mm insulated copper conductor etc. including supply of all fixing materials and accessories and interconnections complete as required. Refer Electrical layout drawings attached with this document. Also refer sl no. 2.0 of Annexure for further requirement.
Wiring for ceiling fan point with 1.5 Sq.mm FRLSH PVC insulated stranded single core copper conductor cable through 20mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark clamped in wall, ceiling or column including supply and fixing of 3Plate ceiling rose in junction box concealed in ceiling, 1No 6A modular switch (LEGRAND 675501 or equivalent) modular plate with regulator (Legrand 675530 or equivalent) in suitable type box concealed in wall and earthing with 1.5 Sq.mm insulated copper conductor etc. including supply of all fixing materials and accessories and interconnections complete as required. Refer Electrical layout drawings attached with this document. Also refer sl no. 2.0 of Annexure for further requirement.
Supply for circuit/ submain wiring along with earth wire with the following sizes of FRLSH PVC insulated stranded single core copper conductor cable, through 20mm/32mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark concealed in wall, ceiling or column or floor including supply of all fixing materials and interconnections complete as required for circuit wiring from the distribution board to first switch board. Refer sl no. 2.0 of Annexure. 2 runs 4sq.mm FRLSH PVC+ 4Sq.mm FRLSH PVC Copper conductor as earth wire.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLSH PVC insulated stranded single core copper conductor cable, through 20mm/32mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark concealed in wall, ceiling or column or floor including supply of all fixing materials and interconnections complete as required for circuit wiring from the distribution board to first switch board. Refer sl no. 2.0 of Annexure. 2 runs 4sq.mm FRLSH PVC+ 4Sq.mm FRLSH PVC Copper conductor as earth wire.
Supply for circuit/ submain wiring along with earth wire with the following sizes of FRLSH PVC insulated stranded single core copper conductor cable, through 20mm/32mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark concealed in wall, ceiling or column or floor including supply of all fixing materials and interconnections complete as required for circuit wiring from the distribution board to first switch board. Refer sl no. 2.0 of Annexure. 2 runs 2.5 sq.mm FRLSH PVC+ 2.5Sq.mm FRLSH PVC Copper conductor as earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLSH PVC insulated stranded single core copper conductor cable, through 20mm/32mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark concealed in wall, ceiling or column or floor including supply of all fixing materials and interconnections complete as required for circuit wiring from the distribution board to first switch board. Refer sl no. 2.0 of Annexure. 2 runs 2.5 sq.mm FRLSH PVC+ 2.5Sq.mm FRLSH PVC Copper conductor as earth wire
Supply of 3 pin 5/6 amps modular socket (LEGRAND 6755 50 or equivalent) outlet and 5/6 amps modular switch( LEGRAND 6755 01 or equivalent), with modular front plate and cover in suitable box concealed in wall with all fixing materials and interconnections as required .
Erection of 3 pin 5/6 amps modular socket (LEGRAND 6755 50 or equivalent) outlet and 5/6 amps modular switch( LEGRAND 6755 01 or equivalent), with modular front plate and cover in suitable box concealed in wall with all fixing materials and interconnections as required .
Supply of 3 pin 5/6 amps modular socket (LEGRAND 6755 50 or equivalent) outlet and 5/6 amps modular switch (LEGRAND 6755 01 or equivalent), with modular front plate and cover in GI box suitable for modular switches concealed in wall with all fixing materials and interconnections as required. 5A Plug socket outlet for the fan shall be provided at a height of 2.0 m from the floor level. The control switch shall be provided at a height of 1.5m from the floor level. (For fixing Wall mount fans)
Erection of 3 pin 5/6 amps modular socket (LEGRAND 6755 50 or equivalent) outlet and 5/6 amps modular switch (LEGRAND 6755 01 or equivalent), with modular front plate and cover in GI box suitable for modular switches concealed in wall with all fixing materials and interconnections as required. 5A Plug socket outlet for the fan shall be provided at a height of 2.0 m from the floor level. The control switch shall be provided at a height of 1.5m from the floor level. (For fixing Wall mount fans)
Supply of 3pin 15/16 amps modular socket (LEGRAND 6755 55 or equivalent) outlet and 15/16amps modular switch with indicator (LEGRAND 6755 13 or equivalent), with modular front plate and cover in box suitable for modular switches concealed in wall with all fixing materials and interconnections complete as required.
Erection of 3pin 15/16 amps modular socket (LEGRAND 6755 55 or equivalent) outlet and 15/16amps modular switch with indicator (LEGRAND 6755 13 or equivalent), with modular front plate and cover in box suitable for modular switches concealed in wall with all fixing materials and interconnections complete as required.
Supply of modular type, RJ 11 Telephone socket (LEGRAND 6755 41 or equivalent), with non metallic front plate including suitable size box concealed in wall with all necessary accessories and interconnections complete as required.
Erection of modular type, RJ 11 Telephone socket (LEGRAND 6755 41 or equivalent), with non metallic front plate including suitable size box concealed in wall with all necessary accessories and interconnections complete as required.
Supply of three Nos of 3 pin 5/6 amps modular socket (LEGRAND 6755 50 or equivalent) outlet and three nos of 5/6 amps modular switch( LEGRAND 6755 01 or equivalent), with modular front plate and cover in suitable box concealed in wall with all fixing materials and interconnections as required. (Computer Points)
Erection of three Nos of 3 pin 5/6 amps modular socket (LEGRAND 6755 50 or equivalent) outlet and three nos of 5/6 amps modular switch( LEGRAND 6755 01 or equivalent), with modular front plate and cover in suitable box concealed in wall with all fixing materials and interconnections as required. (Computer Points)
Supply of 650/1100V, copper conductor XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed cable of size 3C x 4sq.mm. Refer sl no. 3.0 of Annexure for requirement.
Erection of 650/1100V, copper conductor XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed cable of size 3C x 4sq.mm. Refer sl no. 3.0 of Annexure for requirement.
Supply of 650/1100V, copper conductor XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed cable of size 3C x 2.5 sq.mm. Refer sl no. 3.0 of Annexure for requirement.
Erection of 650/1100V, copper conductor XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed cable of size 3C x 2.5 sq.mm. Refer sl no. 3.0 of Annexure for requirement.
Cable termination on panels, on motors/Junction boxes, local control stations etc., testing, commissioning and handing over of 650/1100V, copper conductor XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed cable of size 3C x 4 sq.mm cable, conforming to specifications, data sheets, drawings, relevant Indian Standards, code of practices etc. to the entire satisfaction of the owner and of the following sizes. The scope shall include making cable entries on gland plates on equipment, wherever required, fixing lugs, electrical connections, cable glanding (where applicable) and gland earthing. The scope shall also include supply and installation of all required accessories such as, crimping type tinned copper cable lugs, bolts, nuts, washers, ferrules, gland earth clamps, strips etc. (The cable termination rate shall include gland earthing cable termination also.) Supply of cable glands (where required), and gland earthing cables are excluded from the scope, for which separate rates quoted shall be applicable.
Cable termination on panels, on motors/Junction boxes, local control stations etc., testing, commissioning and handing over of 650/1100V, copper conductor XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed cable of size 3C x 2.5 sq.mm cable, conforming to specifications, data sheets, drawings, relevant Indian Standards, code of practices etc. to the entire satisfaction of the owner and of the following sizes. The scope shall include making cable entries on gland plates on equipment, wherever required, fixing lugs, electrical connections, cable glanding (where applicable) and gland earthing. The scope shall also include supply and installation of all required accessories such as, crimping type tinned copper cable lugs, bolts, nuts, washers, ferrules, gland earth clamps, strips etc. (The cable termination rate shall include gland earthing cable termination also.) Supply of cable glands (where required), and gland earthing cables are excluded from the scope, for which separate rates quoted shall be applicable.
Supply of double compression Nickel plated brass cable glands suitable for 650/1100V, copper conductor XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed cable of size 3C x4 sq.mm cable. The gland shall be suitable for cable entries with ET/NPT threads as required. The bidder shall verify the entry thread, type of hazardous enclosure etc., to find out the actual type of gland required. The scope shall exclude erection, testing, commissioning, associated cabling, earthing, cable and earth terminations, and structural works, as rates quoted elsewhere shall be applicable.
Supply of double compression Nickel plated brass cable glands suitable for 650/1100V, copper conductor XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed cable of size 3C x 2.5 sq.mm cable. The gland shall be suitable for cable entries with ET/NPT threads as required. The bidder shall verify the entry thread, type of hazardous enclosure etc., to find out the actual type of gland required. The scope shall exclude erection, testing, commissioning, associated cabling, earthing, cable and earth terminations, and structural works, as rates quoted elsewhere shall be applicable. Separate erection charges are not applicable for this item.
Supply for light point /exhaust fan/ ceiling fan with 2.5Sq.mm XLPE insulated armoured three core copper conductor cable in wall, ceiling or column or floor including supply and fixing of ,1No 6A modular switch( CRABTREE or equivalent) modular plate in suitable GI box etc.The scope shall also include Supply of flame proof double compression cable glands suitable for 650/1100V grade cables including supply of all fixing materials and interconnections, terminations complete as required.Refer Electrical layout drawings attached with this document.
Wiring for light point /exhaust fan/ ceiling fan with 2.5Sq.mm XLPE insulated armoured three core copper conductor cable in wall, ceiling or column or floor including supply and fixing of ,1No 6A modular switch( CRABTREE or equivalent) modular plate in suitable GI box etc.The scope shall also include Supply of flame proof double compression cable glands suitable for 650/1100V grade cables including supply of all fixing materials and interconnections, terminations complete as required.Refer Electrical layout drawings attached with this document.
Supply for group controlled light points (from one light point to another light point), same as CDP-19-AMT-HVY-121 but without control switch. Supply of items from control switch to first light point is covered in item CDP-19-AMT-HVY-121
Cabling for group controlled light points (from one light point to another light point), same as CDP-19-AMT-HVY-122 but without control switch. Wiring from control switch to first light point is covered in item CDP-19-AMT-HVY-122
Supply of 2 PAIR Telephone cables with concealed conduit system of wiring, with annealed high conductivity copper conductor 0.5mm dia, polyethylene insulated, cores twisted in to pairs, bunched together, laid up, cores taped with absorbant tape, polyethelene sheathed, overall polyethlene jacketed unarmoured cable conforming to TTE/ITD specification. Erection scope shall include all accessories including erection of 20mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark.
Erection of 2 PAIR Telephone cables with concealed conduit system of wiring, with annealed high conductivity copper conductor 0.5mm dia, polyethylene insulated, cores twisted in to pairs, bunched together, laid up, cores taped with absorbant tape, polyethelene sheathed, overall polyethlene jacketed unarmoured cable conforming to TTE/ITD specification. Erection scope shall include all accessories including erection of 20mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark.
Supply of shock proof, rust proof, dust proof, water proof, corrosion proof junction boxes in Thermoplastic Polystyrene enclosure, having internally embedded gasket and suitable dust caps to seal the mounting slots with plane wall surface for different cables. cable glands / bushes of suitable sizes and all other required hard wares shall be included in scope of supply. The junction boxes supplied shall be Hensel make or equivalent as certified by FEDO Engineer in Charge. Mounting of junction boxes shall be on wall / pedestals etc. as required at a height of 1.5m from floor as per the drawing. The scope shall include supply of fixing hardware required for the same. All spare entries of the junction boxes shall be suitably blanked. Fixing bolts / nuts/ screws shall be stainless steel. The scope include drilling suitable holes for cable entry . Supply of Junction boxes with Krone type connectors suitable for terminating 1 No. 5 Pair, 0.5mm dia armoured cable as incomer and 5Nos 2Pair 0.5 mm dia un armoured cable as outgoing.
Installation, testing, commissioning and handing over of shock proof, rust proof, dust proof, water proof, corrosion proof junction boxes in Thermoplastic Polystyrene enclosure, having internally embedded gasket and suitable dust caps to seal the mounting slots with plane wall surface for different cables. cable glands / bushes of suitable sizes and all other required hard wares shall be included in scope of supply. The junction boxes supplied shall be Hensel make or equivalent as certified by FEDO Engineer in Charge. Mounting of junction boxes shall be on wall / pedestals etc. as required at a height of 1.5m from floor as per the drawing. The scope shall include erection of fixing hardware required for the same. All spare entries of the junction boxes shall be suitably blanked. Fixing bolts / nuts/ screws shall be stainless steel. The scope include drilling suitable holes for cable entry . Erection of Junction boxes with Krone type connectors suitable for terminating 1 No. 5 Pair, 0.5mm dia unarmoured cable as incomer and 5Nos 2Pair 0.5 mm dia un armoured cable as outgoing.
Supply of 20W LED WEATHERPROOF type tube light fixed on industrial type batten suitable for surface mounting prewired upto terminal block with all accessories such as drivers lamp holders, lamp etc. with polycarbonate housing and all related accessories like rods for suspension, wires, cable glands, metallic junction boxes etc. (PHILIPS WT201C LED24S-6500 PSU L120or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells/ Bajaj. Refer sl no. 4.0 of Annexure
Erection of 20W LED WEATHERPROOF type tube light fixed on industrial type batten suitable for surface mounting prewired upto terminal block with all accessories such as drivers lamp holders, lamp etc. with polycarbonate housing and all related accessories like rods for suspension, wires,cable glands, metallic junction boxes etc. (PHILIPS WT201C LED24S-6500 PSU L120 or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells/ Bajaj. Refer sl no. 4.0 of Annexure
Supply of 20W LED batten suitable for surface mounting prewired upto terminal block with all accessories such as drivers lamp holders, lamp etc. with acrylic diffuser and with decorative end caps and all related accessories like rods for suspension, wires etc. (PHILIPS BN021C LED22S PSU CW GR S2 or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells/ Bajaj)
Erection of 20W LED batten suitable for surface mounting prewired upto terminal block with all accessories such as drivers lamp holders, lamp etc. with acrylic diffuser and with decorative end caps and all related accessories like rods for suspension, wires etc. (PHILIPS BN021C LED22S PSU CW GR S2 or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells/ Bajaj)
Supply of 6W LED TYPE light fittings suitable for surface mounting with lamp (colour temperature white) all required accessories for fixing and connecting the fitting to the point. (BAJAJ-BGSLO-SLEEK SURFACE -6W-WH RD or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells /OSRAM/ Bajaj)
Erection of 6W LED TYPE light fittings suitable for surface mounting with lamp (colour temperature white) all required accessories for fixing and connecting the fitting to the point. (BAJAJ-BGSLO-SLEEK SURFACE -6W-WH RD or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells /OSRAM/ Bajaj)
Supply of 12W LED TYPE light fittings suitable for surface mounting with lamp (colour temperature white) all required accessories for fixing and connecting the fitting to the point. (BAJAJ-BGSLO-SLEEK SURFACE -12W-WH RD or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells /OSRAM/ Bajaj)
Erection of12W LED TYPE light fittings suitable for surface mounting with lamp (colour temperature white) all required accessories for fixing and connecting the fitting to the point. (BAJAJ-BGSLO-SLEEK SURFACE -12W-WH RD or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells /OSRAM/ Bajaj)
Supply of 10W LED batten suitable for surface mounting prewired upto terminal block with all accessories such as drivers lamp holders, lamp etc. with acrylic diffuser and with decorative end caps and all related accessories like rods for suspension, wires etc. (CROMPTON GREAVES LCTLN or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells/ Bajaj)
Erection of 10W LED batten suitable for surface mounting prewired upto terminal block with all accessories such as drivers lamp holders, lamp etc. with acrylic diffuser and with decorative end caps and all related accessories like rods for suspension, wires etc. (CROMPTON GREAVES LCTLN or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells/ Bajaj)
Supply of 70W /7500Lumens LED type medium bay light fixture in PDC housing suitable for industrial application with all related accessories such as driver, LED lamp etc. The scope shall also include supply of rods/hooks required for suspending the light fittings from the ceiling , cable glands, junction boxes etc (PHILIPS-BY150P LED76S CW PSU HE SY120 FG GR or equivalent type )
Erection of 70W /7500Lumens LED type medium bay light fixture in PDC housing suitable for industrial application with all related accessories such as driver, LED lamp etc. The scope shall also include erection of rods/hooks required for suspending the light fittings from the ceiling cable glands, junction boxes etc(PHILIPS-BY150P LED76S CW PSU HE SY120 FG GR or equivalent type )
Supply of 230 V, single phase and neutral, 16A, socket outlet in cast Aluminium IP 55 weather proof enclosure with integral TPN switch plug socket arrangement (2P+E configuration), cable glands, cable entries, plug top, duplicate earthing terminals, safety interlock to prevent accidental removal of plug while the unit is ON, provision for looping to other unit etc. The incoming cable size shall be 3C x 4 sq.mm YFY/ YWY cable . All external hardwares shall be stainless steel.
Erection of 230 V, single phase and neutral, 16A, socket outlet in cast Aluminium IP 55 weather proof enclosure with integral TPN switch plug socket arrangement (2P+E configuration), cable glands, cable entries, plug top, duplicate earthing terminals, safety interlock to prevent accidental removal of plug while the unit is ON, provision for looping to other unit etc. The incoming cable size shall be 3C x 4 sq.mm YFY/ YWY cable . All external hardwares shall be stainless steel.
Supply of 1200mm sweep ceiling fans, capacitor type complete with standard length down rod, canopies, shackle, rubber bush, blades etc. Fan shall be suitable for operation on 230V, 50HZ single phase AC supply conforming to IS-374 completely pre wired upto terminal block. (HAVELLS model Velocity ES 40 or equivalent)
Erection of 1200mm sweep ceiling fans, capacitor type complete with standard length down rod, canopies, shackle, rubber bush, blades etc. Fan shall be suitable for operation on 230V, 50HZ single phase AC supply conforming to IS-374 completely pre wired upto terminal block. (HAVELLS model Velocity ES 50 or equivalent)
Supply of Heavy duty, totally enclosed motor industrial type EXHAUST FAN suitable for operation on 230Volts, 50Hz single phase AC supply complete with standard length of 3 core flexible copper conductor cable, and of 230 mm sweep conforming to IS-2312 (with latest amendments). Supply scope shall also include supply of switches along with metallic box and coverplate.Erection scope shall also include glanding of cable at the fan and at the switchboard(HAVELLS VENTILAIR DS or equivalent)
Erection of Heavy duty, totally enclosed motor industrial type EXHAUST FAN suitable for operation on 230Volts, 50Hz single phase AC supply complete with standard length of 3 core flexible copper conductor cable, and of 230 mm sweep conforming to IS-2312 (with latest amendments). Supply scope shall also include supply of switches along with metallic box and coverplate.Erection scope shall also include glanding of cable at the fan and at the switchboard (HAVELLS VENTILAIR DS or equivalent)
Supply of 240V, single phase, 400 mm sweep, minimum 2000 RPM speed, copper-wound wall mount type fan with all accessories such as control switch, nuts, bolts, etc. (HAVELLS PLATINA or equivalent)
Erection of 240V, single phase, 400 mm sweep, minimum 2000 RPM speed, copper-wound wall mount type fan with all accessories such as control switch, nuts, bolts, etc. (HAVELLS PLATINA or equivalent)
Supply of Flameproof Ex-d IP65 Tube light fitting suitable for 1x20W LED tube for gas groupIIA/IIB/IIC with flame proof double compression cable glands, wire guard, internal and external earth studs suitable for battery room application with all accessories.
Erection of Flameproof Ex-d IP65 Tube light fitting suitable for 1x20W LED tube for gas groupIIA/IIB/IIC with flame proof double compression cable glands, wire guard, internal and external earth studs suitable for battery room application with all accessories.
Supply of Flameproof EX-d IP66 exhaust fan suitable for Gas group IIC with flame proof double compression cable glands, wire guard, internal and external earth studs gravity louvers shutters rigid frame with rubber mountings and of 406mm sweep suitable for battery room application with all accessories.
Erection of Flameproof EX-d IP66 exhaust fan suitable for Gas group IIC with flame proof double compression cable glands, wire guard, internal and external earth studs gravity louvers shutters rigid frame with rubber mountings and of 406mm sweep suitable for battery room application with all accessories.
Supply of structural steel items as per drawings enclosed for racks, risers and tray supports, pedestals, DB supports, supports for other equipment, etc. as required. The painting shall be with two coats of epoxy paint over 2 coats of suitable epoxy primer.
Fabrication, erection, fixing, epoxy painting and handing over of structural steel items as per drawings enclosed for racks, risers and tray supports, pedestals, DB supports, supports for other equipment, etc. as required. The painting shall be with two coats of epoxy paint over 2 coats of suitable epoxy primer.
Supply of pipe electrode earth pits as per Drg No.32686-13-GE-00 251. The scope shall include excavation with shuttering if required, dewatering the excavated pit if required, refilling with charcoal & sand, construction of inspection chamber with cover slab, etc. The supply scope shall include supply of electrodes, GI pipes, earth conductors and funnel and all other accessories required. The scope shall also include supply of all accessories such as sand, reinforcement steel, brick, rubble, PVC pipes, clamps, bolts, nuts, washers, bitumen compound, etc. For general requirements refer Annexure.
Erection, Testing, Commissioning and Handing over of pipe electrode earth pits as per Drg No.32686-13-GE-00 251. The scope shall include excavation with shuttering if required, dewatering the excavated pit if required, refilling with charcoal & sand, construction of inspection chamber with cover slab, etc. The supply scope shall include supply of electrodes, GI pipes, earth conductors and funnel and all other accessories required. The scope shall also include supply of all accessories such as sand, reinforcement steel, brick, rubble, PVC pipes, clamps, bolts, nuts, washers, bitumen compound, etc. For general requirements refer Annexure.
Supply of 25x6 GI Strip for lightning protection of buildings.
Erection of 25x6 GI Strip for lightning protection of buildings.
Supply of 32x6 GI Strip for lightning protection of buildings.
Erection of 32x6 GI Strip for lightning protection of buildings.
Supply of PVC covered Aluminium conductors of size 16 sq.mm for DB earthing.
Erection of PVC covered Aluminium conductors of size 16 sq.mm for DB earthing.
Making wall openings in brick wall of thickness 300mm or below for the purpose of laying cables, and replastering. The charges furnished shall cover supply of all required materials except cement. For other requirements refer sl no. 1.0 of Annexure.
MBM ENGG WORKS
BREC Projects Private Limited
Malayil Builders Pvt Ltd
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .