Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.2 LAccepted-AOC 49 53 7 13 1ST FLOOR SAMPADA GALAXY BS LAYOUT NEAR 4TH TOWN POLICE STATION VISAKHAPATNAM ANDHRA PRADESH 530013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | L1 | Accepted-AOC Being L1 | |
| 2 | L1₹49.5 LRejected-Finance 34 10 37 1 GNANAPURAM DAYAS STREET VISAKHAPATNAM VISAKHAPATNAM ANDHRA PRADESH 530004 | VISAKHAPATANAM | ANDHRA PRADESH | 530004 | L1 | Rejected-Finance Not Being L1 | |
| 3 | L3₹60.5 LRejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹73.9 LRejected-Finance SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASAPURA CV RAMAN NAGAR PO BANGALORE 560 093 | BANGALORE | BANGALORE | KARNATAKA | 560093 | L4 | Rejected-Finance Not Being L1 |
Tender Value
₹47.8 L
EMD Value
₹95,600
Closing Date
16 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) (DM) VISAKHAPATNAM
GE(I)DM Visakhapatnam Naval Dockyard 530014
M2 MAINTENANCE OF 132 KV GIS SYSTEM AND ALLIED WORKS AT MRS AT NAVAL DOCKYARD, VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
2022_MES_509853_3
SSGE/8656/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (I) (DM) VISAKHAPATNAM
As per Tender Documents
9 documents required · 9 mandatory
₹500
GE (I) (DM) VISAKHAPATNAM
₹95,600
Yes
3 Aug 2022
26 May 2022
24 Jun 2022
26 May 2022
16 Jun 2022
2 Jun 2022
Amount
M&L for M2 maintenance & servicing of 132 KV GIS system by OEM (ie service enginer of GE T&D India Ltd) (formerly Areva), executing the following services, testing and submission of complete report all as specified and directed :- (a) Gas Test for all the bay compartment (Dew point measurement SF6 purity check {% measurement} Alarm check for density switches optional Gas leak test. (b) Circuit Breaker mechanical test :- Visual inspection of spring operated mechanism mannually on/off spring-operated mechanism optical indicator( spring on/off) position check. (c) Electrical test :- Breaker timing test, Auxiliary contact change over position, check spring charge motor current measures & time measurement, heater current measurement. (d) Disconnector/Earthing switches mechanical test:- Mannually on/off with hand crank optical position indication check for change over, insulated earth switch external earthing link installation & tightness check. (e) Contact resistance check:- Test as per circuit proposed during commissioning. (f) Current & voltage transformer/Local control cubicle:- Terminal tightness check and equipment operational and alram test.
Note :- (1) Contractor shall arrange all all tools & plants required for the work or shall be provided by OEM (2) Hiring charges of Service Engineer, Foreman, Fitters, & Electrician are included in quoted rate. (3) All consumables required for the work is included in quoted rate. (4) Spare if requires for proper servicing of the installation is included in the quoted rate. (5) Before commencement of the work necessary certificates of Service Engineer, Foreman, Fitters, & Electrician shall be obtained from OEM and shall be submitted to Eng-in charge for approval
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in soft loose soil for cable work or from above cable duct complete all as specified and as directed
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed
Removing of excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed
M&L for dry sand cushioning for under ground cable provided with layer and sand 8 cm deep before laying the cable and 15cm after laying the cable complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mm x 180mm x 40mm complete all as specified and as directed.
M&L for PCC 1:3:6 , type-C 2, using 40mm graded aggregate for repair to path/drain/road against damage due to excavation/laying of cable complete all as specified and as directed.
S/L in trenches or in duct or passing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, overall PVC sheathed electric power cables (heavy duty) with aluminium conductor, 11000 volts grade (Earthed) cross sectional area 185 sq. mm 3 core including dismantling / taking down unserviceable one complete all as specified and as directed.
All as per item No 8.00 above but of size 240 sq. mm 3 core including dismantling / taking down unserviceable one complete all as specified and as directed.
All as per item No 8.00 above but of size 300 sq. mm 3 core including dismantling / taking down unserviceable one complete all as specified and as directed.
All as per item No 8.00 above but of size 400 sq. mm 3 core including dismantling / taking down unserviceable one complete all as specified and as directed.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 150 sqmm to 185 sqmm after opening VCB panel back side cable cover and bottom cable entry plate after disconneting unsv cable kit from busbar/CT, taking out from VCB cable chamber and fixing the same to original position, with new or old nuts, bolts & washers, bottom plate, back cover and making cable entry point totally sealed with putty complete all as specified and as directed.
All as per item No 12.00 above (indoor termination) but for cable of size 240sqmm to 300 sqmm including dismantling / taking down unserviceable one.
All as per item No 12.00 above (indoor termination) but for cable of size 400 sqmm including dismantling / taking down unserviceable one complete all as specified and as directed.
Dismantling taking out HT/LT Cable from cable duct of substations for realingnment of cable and relaying with proper alingnment for the cable of size 3 core, 185 sqmm, 11000 volts grade. (Note: Each cable shall be measured separately. Steel cable rack shall be measured separately as supply and fix) all as specified and directed.
All as per item No 15.00 above but for cable sizes 240sqmm complete all as specified and as directed.
All as per item No 15.00 above but for cable sizes 300 sqmm complete all as specified and as directed.
All as per item No 15.00 above but for cable sizes 400sqmm complete all as specified and as directed.
aswitha engineering works
Jessica Engineering Works
B5BUILDING SOLUTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .