Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 CrAccepted-AOC 121 MODEL TOWN AMBALA CITY HARYANA 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | ₹23.3 Cr | L1 | Accepted-AOC lowest Tenderer |
| 2 | L2₹23.5 CrRejected-AOC D 154 D 154 GROUND FLOOR INDUSTRIAL ESTATE PHASE VII MOHALL | ₹23.5 Cr | L2 | Rejected-AOC Higher side rates quoted |
| 3 | L3₹24.0 CrRejected-AOC 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹24.0 Cr | L3 | Rejected-AOC Higher side rates quoted |
| 4 | L4₹24.5 CrRejected-AOC RZ 382 3RD FLOOR GALI NO 11B KAILASH PURI EXTN PALAM COLONY PALAM VILLAGE NEW DELHI 110045 | SOUTH WEST | DELHI | 110045 | ₹24.5 Cr | L4 | Rejected-AOC Higher side rates quoted |
| 5 | L5₹24.6 CrRejected-AOC | ₹24.6 Cr | L5 | Rejected-AOC Higher side rates quoted |
Tender Value
₹26 Cr
EMD Value
₹15 L
Closing Date
22 Jun 2020, 6:00 pmClosed
CHIEF ENGINEER CHANDIGARH ZONE
Military Engineer Services HQ Chief Engineer, Chandigarh Zone
PROVISION OF KLP ACCN FOR AD REGT(L-70) (PHASE-I) AT AMBALA CANTT
2020_MES_318306_1
83631E8
Open Tender
Civil Works
607 days
Ambala
As Per NIT
6 documents required · 6 mandatory
₹3,000
Yes
₹15 L
Yes
CE CHD ZONE CHANDIGARH
17 Aug 2020
25 Jan 2020
24 Jun 2020
25 Jan 2020
22 Jun 2020
15 Jun 2020
26 Jan 2020 - 17 Feb 2020
11 Feb 2020
Amount
Schedule 'A'Section-I A (Building /Structure Works)
Total amount of Sch 'A' Sec- IA (Building/Structure Works)
Schedule 'A'Section-I B (Building/ Structure Works OHT)
Total amount of Sch 'A' Section - I B (Building Works OHT)
Schedule 'A'Section-II (INTERNAL ELECTRIFICATION WORKS)
Total amount of Sch 'A' Sec- II (Internal Electrification Works)
Schedule 'A'Section-III (INTERNAL WATER SUPPLY, HOT WATER SUPPLY & MECH LAUNDRY WORKS)
Total amount of Sch 'A' Sec- III ( INTERNAL WATER SUPPLY, HOT WATER SUPPLY & MECH LAUNDRY WORKS)
Schedule 'A'Section-IV (SEWAGE DISPOSAL WORKS)
Total amount of Sch 'A' Sec- IV (Sewage Disposal Works)
Schedule 'A'Section-V (AREA DRAINAGE WORKS)
Total amount of Sch 'A' Sec - V (Area Drainage Works)
Schedule 'A'Section-VI (ROAD PATH & CULVERT WORKS)
Total amount of Sch 'A' Sec- VI (Road Path & Culvert Works)
Schedule 'A'Section-VII (SECURITY WALL & SECURITY FENCING WORKS)
Total amount of Sch 'A' Sec -VII (Security Wall and Security Fencing Works)
Schedule 'A'Section-VIII (EXTERNAL WATER SUPPLY WORKS)
Total amount of Sch 'A' Sec -VIII (EXTERNAL WATER SUPPLY WORKS)
Schedule 'A'Section-IX (EXTERNAL ELECTRIC SUPPLY, ELECTRIC SIREN, LIGHTENING PROTECTION &SUMMAR APPLIANCES WORKS)
Total amount of Sch 'A' Sec- IX (EXTERNAL ELECTRIC SUPPLY, ELECTRIC SIREN, LIGHTENING PROTECTION & SUMMAR APPLIANCES WORKS)
Schedule 'A'Section-X (SITE DEVELOPEMENT AND MISC EARTH WORKS)
Total amount of Sch 'A' Sec- X (SITE DEVELOPEMENT AND MISC EARTH WORKS)
Schedule 'A'Section-XI (Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
INTERNAL ELECTRIC SUPPLY WORKS
Item No. 1: Point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 Sqmm (nominal area), single core, flame retardant low smoke (FRLS-H), PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked TEC and FIA approved in and including heavy duty PVC concealed conduit and its fittings, ISI marked, PVC junction boxes, mild steel sunken boxes (Terminal boxes) with earth dolly, duly painted internally & externally with two coats of anti-corrosive paint over a coat of red oxide primer, covered with 3mm thick hylem sheet including flame retardant low smoke (FRLS) PVC insulated unsheathed stranded copper conductor 1.5 Sq. mm (nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified, for the following : -
1(a): One light point controlled by one switch or one (Ceiling/ Wall/ Exhaust) fan point controlled by one switch or one switch and regulator
1(b): One 3 pin 5 Amps socket outlet on independent board.
1(c) : One 3 pin 5 Amps socket outlet on same board.
1(d) : One socket outlet, 16 Amp, independent, with 2.5 sqmm (nominal area) cable for phase & neutral and 2.5 sqmm (nominal area) cable as earth continuity conductor.
Item No. 2: All as per item ser No -01 hereinbefore but one light point controlled by two 2 way switches.
Item No. 3: LED mirror light fitting, surface mounted 9 watt LED decorative fixture with all accessories internally pre-wired with and including connecting up with three core flexible copper conductor cable of size 1.0 Sqmm,LED complete all as specified and directed. Make: Havels cat Part- No. Ivory LED 9 W LHESABP6IN1W009 or equivalent make as mentioned in Appendix 'B'.
Item No. 4: LED (batten tubelight) suitable for 1x22 Watt LED tube rod, with and including 1 no LED tube rod 22Watt with all accessories complete, pre-wired with & including connecting up with three core flexible copper conductor cable of size 1.0 Sqmm complete all as specified and directed. Make : Havells Cat Part No. LHFYBYPNIAW022 for LED Batten and Havells Cat part No LHLDDBXNMN7Z022 for LED tube rods or cat parts of equivalent makes as mentioned in Appendix 'B'.
Item No. 5: Bldg Security light LED fitting, pressure die cast housing with epoxy power coated dark graphite grey colour finish prismatic polycarbonate cover with individual LED lens & IP-65 protection, 20 watt fixed on wall/pole with and including suitable bracket of light grade GI pipe/ clamps, nuts & bolts etc. including connecting up with three core flexible copper conductor cable of size 1.0 Sqmm complete all as specified and directed. Make Wipro,Cat part No LR02-261-XXX-57-XX or equivalent make as mentioned in Appendix 'B'.
Item No. 6 : Street Security light LED fitting, pressure die cast housing with epoxy power coated dark graphite grey colour finish prismatic polycarbonate cover with individual LED lens & IP-65 protection, 60 watt fixed on wall/pole with and including suitable bracket of light grade GI pipe/ clamps, nuts & bolts etc. including connecting up with three core flexible copper conductor cable of size 1.0 Sqmm complete all as specified and directed. Make Wipro,Cat part No LR02-671-XXX-57-G2 or equivalent make as mentioned in Appendix 'B'.
Item No. 7 : Ceiling fan 1200mm sweep with fan box including electronic stepped type fan regulator flush type fixed on laminated sheet, with provision of cable PVC insulated and sheathed FRLS grade 3 core 0.5mm copper conductor flexible wire 1100 volts grade from procelain connector /ceiling rose to ceiling fan, complete all as specified and directed.
Item No. 8 : Exhaust fan 380mm sweep complete with louvers suitable for operation on 230 Volts, AC, 50Hz AC supply, fixed on wall complete all as specified and directed.
Item No. 9 : MCB distribution board having IP-43 protection, powder coated, double door, flush mounted TPN 4 way with 200 Amp rated bus bars, complete all specified and as directed.
Item No. 10 : MCB distribution board having IP-43 protection, powder coated, double door, flush mounted complete suitable for 12 way SPN with 200 Amp rated bus bars 230 volt AC supply, complete all as specified and as directed.
Item No. 11 : All as per item-10 here-in-before but 8 way.
Item No. 12 : All per item-10 here-in-before but 6 way.
Item No. 13 : All as per item-10 here-in-before but 4 way.
Item No. 14 : MCB, single pole, 6 to 32 Amp, 240 Volts, having breaking capacity 10 KA 'B' curve, complete all as specified and as directed.
Item No. 15 : MCB, single pole and neutral, 6 to 32 Amp, 240 Volts, having breaking capacity 10 KA, 'B' curve, complete all as specified and as directed.
Item No. 16 : MCB, single pole and neutral, 40 Amp, 240 Volts, having breaking capacity 10 KA, 'B' curve, complete all as specified and as directed.
Item No. 17 : MCB, triple pole and neutral 32 Amp, 415 Volt, having breaking capacity 10 KA, 'B' curve, complete all as specified and as directed.
Item No. 18 : MCB, triple pole and neutral 40 Amp, 415 Volt, having breaking capacity 10 KA, 'B' curve, complete all as specified and as directed.
Item No. 19 : MCB, triple pole and neutral 50 Amp, 415 Volt, having breaking capacity 10 KA, 'B' curve, complete all as specified and as directed.
Item No. 20 : MCB, triple pole and neutral, 63 Amp, 415 Volts, having breaking capacity 10 kA 'B' curve, complete all as specified and as directed.
Item No. 21: LED retrofit lamp 7 watt with B-22 base, complete all as specified and as directed.
Item No. 22 : Sub main wiring using approved colour coding as per IS with five single core, PVC insulated, unsheathed FRLS multistranded copper conductor cables of size 10.00 sqmm (nominal area) 1100 volts grade, drawn through & including heavy duty PVC concealed conduit of suitable bore and connected to main board, complete all as specified and as directed. Note: (i) Five runs each of one RM of 10.00 sqmm cable together shall be considered as 1 running meter for payment purpose.
Item No. 23 : Sub main wiring using approved colour coding as per IS with three (two for main & one for earth) single core, PVC insulated, unsheathed FRLS multistranded copper conductor cables of size 6.00 sqmm (nominal area) 1100 volts grade, drawn through & including heavy duty PVC concealed conduit of suitable bore and connected to main board, complete all as specified and as directed. Note: (i) Three runs each of one RM of 6.00 sqmm cable together shall be considered as 1 running meter for payment purpose.
Item No. 24 : Sub main wiring using approved colour coding as per IS with three (two for main & one for earth) single core, PVC insulated, unsheathed FRLS multistranded copper conductor cables of size 4.00 sqmm (nominal area) 1100 volts grade, drawn through & including heavy duty PVC concealed conduit of suitable bore and connected to main board complete all as specified and as directed. Note: Three runs each of one RM of 4.00 sqmm cable together shall be considered as 1 running meter for payment purpose.
Item No. 25 : Sub main wiring using approved colour coding as per IS with five single core, PVC insulated, unsheathed FRLS multistranded copper conductor cables of size 6.00 sqmm (nominal area) 1100 volts grade, drawn through & including heavy duty PVC concealed conduit of suitable bore and connected to main board complete all as specified and as directed. Note: Five runs each of one RM of 6.00 sqmm cable together shall be considered as 1 running meter for payment purpose.
ROAD, PATH AND CULVERTS
Item No. 26: 60mm thick machine pressed precast concrete (of M-35 grade) interlocking paver block, manufactured in an automatic plant working on vibration and simultaneous hydraulic compression from top, (with grey cement and no pigment) any shape and size confirming to IS 15658-2006 laid over and including 50mm thick cushion of coarse sand & filling the joints after laying complete all as specified and as directed.
Item No. 27: 60mm thick machine pressed precast concrete (of M-35 grade) interlocking paver block, manufactured in an automatic plant working on vibration and simultaneous hydraulic compression from top, (with grey cement and pigment) any shape and size confirming to IS 15658-2006 laid over and including 50mm thick cushion of coarse sand & filling the joints after laying, complete all as specified and as directed.
Item No. 28: Hot applied thermoplastic road marking inclusive type- I reflectorising glass beads as per table 800-3, 800-4 of MORT&H applied in uniform thickness of at least 1.5mm and spread uniformly with reflectorising glass beads type-II @ 250 gms per sqm with a road marking machine as per IRC:35, with necessary traffic diversion arrangemets if required, complete all as specified and as directed. Make : RELIANCE/ ASIAN PAINTS
SECURITY WALL & SECURITY FENCING
Item No. 29 : Preparing newly plastered or concrete surface of wall/ ceiling and applying two coats of exterior emulsion paint over a coat of alkali resistant primer of approved shade/tint complete all as specified and as directed.
Item No. 30 : Electro-galvanized punched tape concertina coil with closed dia of 610 mm and when opened to a length up to 6m, the dia shall not be less than 580mm, tensile strength not less than 1600 N/Sqmm and having weight not less than 9 kg in 50 turns and 129 nos clips, including provision of necessary GI U clips fixed in position over security wall to angle iron posts/horns. NOTE : a) The material for punched tape shall be cold rolled low carbon steel conforming to IS 513/2008 (reaffirmed in 2013 with amdt no. 1) b) The material for concertina coil shall be cold drawn un-alloyed steel wire and mild steel wire conforming to IS 4454/2001(reaffirmed in 2010) & IS 280/2006(reaffirmed in 2010 with amdt no. 1) respectively. c) Test certificate shall be submitted along with the material. d) Stretched length of concertina coil shall be measured for payment purpose. One coil of 50 turns shall not be stretched more than 06 metre.
EXTERNAL WATER SUPPLY
Item No.31: Electronic logging of the location to ascertain the availability of water and suitability of drilling borewell at that location and submitting report (data shall be collected by a specialist in the field and report is compiled and submitted by him only) complete all as specified.
Item No. 32: Drilling pilot bore hole of 250mm dia by rig plant DTH machine /reverse rotary rig machine unit in any kind of soil or rock including disposal of surplus soil/rock to a distance not exceeding 50 metre complete all as specified including deploying required rig machinery, T&P, equipment etc. complete including transporting of all materials like rig machine, tools & plants, collection of log samples (drilling /cutting) and to maintain drill time log book all as specified to a depth not exceeding 400 metre complete all as specified and as directed.
Item No. 33 : Reaming of 250mm pilot bore hole to 675mm bore with direct circulation rig machine /reverse rotary circulation method in any kind of strata of soil /rock from ground level upto approx 60 metre,complete all as specified and directed.
Item No. 34: Reaming of 250mm pilot bore hole to 525mm dia with direct circulation method in any kind of strata of soil /rock from 60 metre depth to 400 metre approx,complete all as specified and directed.
Item No. 35: Supply and assembling including jointing, lowering and fixing in position plain mild steel ERW plain end casing pipe 300mm nominal bore, 9.5 to 10mm thick conforming to IS-4270, jointed and welded with coupler rings (welding shall be done through out the circmference of the pipe and coupler rings both sides), complete all as specified and as directed.
Item No.36: All as per item No. 35 hereinbefore but 200mm nominal bore with 7.9 to 8mm thick plain sheet in random length of 04 to 07 metres.
Item No.37: All as per item No. 35 but slotted pipe 200mm bore 5.4mm thick conforming to IS complete all as specified and as directed. Note :- (i) The size of slots shall be designed by the contractor based on aquifiers arranged at the equal distance all around the slotted pipe so as to make the perforation area 15 to 20% of slotted pipe.
Item No. 38 : Mild steel (ERW) bail plug assembly 6 mm thick suitable for 200mm nominal bore casing pipe internally threaded with strong iron hook, screwed and welded to casing pipe, and handing over the sample strata box to GE, complete all as specified and as directed.
Item No. 39 : Lowering into bore holes centering guides made out of mild steel flat rings, ribs suitable for 200 mm/ 300 mm dia casing pipe, complete all as specified and as directed.
Item No. 40 : Mild steel housing clamps 105 cm long 200 mm wide made out of 12 mm thick MS plate made to shape for 300 mm bore casing pipe with necessary bolts, nuts and washers at ground level, complete all as specified and as directed.
Item No. 41 : Mild steel well cap 8 mm thick, suitable for 300 mm bore, having internal threads and with welded iron handle complete all as specified and as directed.
Item No. 42 : Chain pulley block of capacity 3 ton suitable size of MS chain for five metre lift complete with all accessories, complete all as specified and as directed.
Item No. 43 : Development of bore including flushing out of tree roots, silt, fine sand etc by using air compressor of suitable capacity not less than 500 CFM at 200 to 250 PSI and over pumping (25% extra capacity pump) for required hours (Minimum 16 Hrs) to make available water free from turbidilty and till clear water is obtained complete all as specified and as directed.
Item No. 44 : Supply and packing pea gravel of size 2 mm to 4.6 mm all around casing pipe and slotted pipe complete all as specified and as directed.
Item No. 45 : Supplying, lowering, jointing, testing and commissioning column pipe, heavy duty 100 mm internal dia ERW steel pipe, 3 metre long with both ends threaded and fitted with heavy duty MS flanges 25 mm thick, two Nos grooves for submersible cable continuous welded and drilled 08 Nos holes with & including jointing materials such as bolts, nuts, washers and rubber gasket etc, complete all as specified and as directed.
Item No. 46 : Supply and lowering 100mm bore GI pipe medium grade including necessary fitting and jointing in the annular space on two side of the bore well upto the depth of 10 metre below ground level and 50cm above the ground for gravel feeding whenever required complete all as specified and as directed.(NOTE:-Gravel feeding will be measured and paid for separately)
Item No. 47 : Supplying, lowering, installation, testing and commissioning of submersible pump set complete with suitable three phase 415 volts submersible electric motor coupled with the pump having discharge capacity not less than 1240 LPM in 130 metre head with bronze impellor and stainless steel shaft (the capacity of electric motor shall be suitable to give the required discharge at the required head and of suitable capacity complete all as specified and as directed. NOTE:- (i) The column pipe and submersible cable required for lowering the pump set shall be measured and paid for separately. (ii) The length of submersible cable connected alongwith motor supplied by the manufacturer alongwith items such as nuts, bolts, gasket, clamps etc required for lowering the submersible pump set shall deemed to be included in unit rate quoted for this item.
Item No. 48 : Supplying, laying, jointing and testing PVC insulated submersiblecable (water proof) flat stranded heavy duty with copper conductor 1100 volts grade, 16 sqmm 3 core ISI marked and connected to submersible pump set, complete all as specified and as directed.
Item No. 49 : Supplying, laying, jointing & testing at site socket and spigot (S&S) ductile iron pipe, centrifugally cast, ISI marked (IS : 8329 amended upto date) class K-9 and nominal dia 150mm with and including push on type EPDM ISI marked (IS : 5382) rubber gasket jointing including zinc coating with finishing layer of bitumen coating on outside of pipe and ordinary portland cement lining from factory from inside of pipe complete all as specified and as directed.
Item No. 50: Supplying, laying, jointing & testing at site socket and spigot (S&S) ductile iron pipe, centrifugally cast, ISI marked (IS : 8329 amended upto date) class K-7 and nominal dia 150mm with and including push on type EPDM ISI marked (IS : 5382) rubber gasket jointing including zinc coating with finishing layer of bitumen coating on outside of pipe and ordinary portland cement lining from factory from inside of pipe complete all as specified and as directed.
Item No. 51 : Supplying, laying, jointing & testing at site socket and spigot (S&S) ductile iron pipe, centrifugally cast, ISI marked (IS : 8329 amended upto date) class K-7 and nominal dia 100mm with and including push on type EPDM ISI marked (IS : 5382) rubber gasket jointing including zinc coating with finishing layer of bitumen coating on outside of pipe and ordinary portland cement lining from factory from inside of pipe complete all as specified and as directed.
Item No. 52 : Sluice valve, 150 mm bore, cast iron body, having brass spindle with iron wheel at top, class PN 1.6, with flanged ends, drilled suitably, complete with joints and including necessary joints by means of bolts, nuts washers and rubber gaskets, conformig to IS - 14846, complete all as specified and as directed.
Item No. 53 : All as per item No.- 52 here-in-before but 100 mm bore.
Item No. 54 : All as per item No.- 52 here-in-before but 80 mm bore.
Item No. 55 : Cast iron air release valves with two air outlets, 150mm bore and fixing up in cast iron water supply mains complete all as specified and as directed.
Item No. 56 : Cast iron Non-return valve size 150mm bore, ISI marked, both ends flanged, including rubber or pipe board gasket, nuts, bolts and washers complete all as specified and as directed.
Item No. 57 : DI fittings like bends (any type, radius and angle) Tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, `Y' junction, double branch, cross (with ends flanged or socketted) collars, caps and plugs suitable for K-7 & K-9 DI pipes, complete all as specified and as directed.
Item No. 58 : Construction of brick masonary valve pit of 1200 mm x 1200mm x 1200mm (internal size) with 3mm thick mild steel sheet cover and angle iron frame of size 40mm x 40mm x 6mm including provision of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Item No. 59 : All as per item No. 58 here-in-before but 900 mm x 900mm x900mm (internal size)
Item No. 60 : All as per item No. 58 here-in-before but 600 mm x 600mm x600mm (internal size)
Item No. 62 : All as per item No - 61 hereinbefore but outdoor type made out of 3.15mm CRCA sheet complete with and including following:- (a) Aluminium bus bars,TPN,200Amps -01 Set. (b) MCCB,4Pole,100Amps -01No (c) Digital Voltmeter 0-500 Volts-01 No. (d) Digital Ammeter 0-200 Volts-01 No. (e) Star delta starter for pump of capacity minimum 40 HP -01 No.
Item No. 63 : Supply only empty gas cylinder 100 kg capacity fitted with valves and valve gaurds complete all as specified and as directed.
Item No. 64 : Supply only chlorine gas complete all as specified and directed.
Item No. 65 : Supply only chlorine gas mask complete all as specified and directed.
Item No. 66 : Vaccum chlorinator direct cylinder mounted type, for pressure feed including all gauges, pump, motor conforming to IS : 10553 Part-II having capacity 1 to 100gm/hr, complete all as specefied and directed.
Item No. 67 : Bleaching dozor bucket type, of capacity 145 ltrs, complete all as specefied and directed.
Item No. 68 : Supply installation testing and commissioning of Eco friendly, silent diesel engine driven generating set of 62.5 KVA (at site) or nearest higher capacity at 0.8 power factor or nearest higher size, 415/430 volts AC, 3 phase, 50 Hz, 4 wire, 0.8 power factor directly coupled alternator and engine, water cooled common base platform with floor mounted fuel tank to meet the requirement of fuel for 8 to 12 Hrs and including all excavation, PCC foundation, anti-vibration pads/dampers including standard control panel as per manufacturer's instructions as directed by manufacturer and other accessories comprising of following :- (a) Engine : Eco friendly for emmission and noise (CPCB NORMS COMPLIANCE) diesel engine 4 stroke and cylinder as per manufacture's design confirming to BS standard developing suitable BHP, 1500 RPM, turbocharged after cooling complete under NTP condition with a provision for 10% over load for one hour on 12 hours running with the following :- (i) Fly wheel with starter ring for generating set (ii) Dry type air filter (iii) Lube oil cooler assembly with accessories (iv) Exhaust air manifold (v) Exhaust silencer (vi) Expension bellow (b) Alternator : Brushless type suitable for direct coupling to engine, self excited, self regulated with fast response thyristor type electronic automatic voltage regulator for output voltage within desired limits (+1%) dynamically balanced 400/415 volts AC, 3 phase, 50 Hz, 4 wire, 0.8 power factor lagging 62.5 KVA or nearest size on higher side, 1500 RPM, star connected (4 wire) screen protected drip proof enclosures, air cooled with radial fan mounted on rotor with insulation class F/H all as per BS-2613, IS-4722 with following accessories : (i) One MS frame suitable for mounting of engine and alternator. (ii) Two nos. 12 volts DC battery of 180 AH capacity SMF type with copper leads and terminal lugs of suitable size. (iii) One set of AVM pads fitted on base frame. (iv) One hand rotary type fuel pump connected with heavy duty pipe upto the tank (v) Adequate ventilation to meet air requirement for combustion and heat removal with a provn of blower. (vi) Emergency stop push button outside the container. (vii) Provn of light inside the canopy providing a LED tube light fitting. (c) Foundation : Cost of PCC foundation as per manufacturer's design/instructions is deemed to be included in the cost of generator set. (d) Supply installation, commissioning and testing of accoustic enclosure suitable for DG shall be as under: (i) Fabricated out of CRCA sheet of suitable thickness. Polyester based duly powder coated internally and externally with lockable type door handle. All nuts, bolts and hardware shall be zinc coated. (ii) Sheet metal components shall be hot dip seven tanks pretreated. (iii) The doors are shall be gasketed with EPDM gaskets. (iv) Sound proofing shall be with high quality rock wool/mineral wool confirming to IS 8183 of 50 mm thickness.
Item No. 69 : All as per item No-68 here-in-before but DG set of 40 KVA (at site) or nearest higher capacity with engine of suitable capacity & Alternator of capacity not less than 40 KVA.
Item No. 70 : Supply only emergency safety kit to stop leakage of chlorine gas from cyllinder complete all as specified and as directed.
Item No. 71 : Supply only Rubber/PVC hand gloves to handle chloring gas liquid complete all as specified and directed.
Item No. 72 : Supply only Rubber/PVC gum boot to handle chlorine gas liquid, complete all as specified and directed.
Item No.73 : Supply only chlorine test kit, complete all as specified and directed.
SEWAGE TREATMENT PLANT
Item No. 74 :- Design, Supply, installation, commissioning and testing of Sewage Treatment Plant based on principle of aerobic attached growth non clogging randomly Moving Bed Bio-reactor (MBBR) having capacity 100 KLD including all civil works for STP, including the following so as to achieve the parameters mentioned elsewhere in the tender documents from any one of the OEM's mentioned in Schedule 'A 'notes :- (i) 01 No sewage collection chamber in RCC construction and 02 Nos. Raw sewage pumps of suitable capacity (ii) 01 No. fine bar screen chamber with bar screen MS epoxy painted. (iii) 01 No. Oil & Grease chamber in RCC construction (iv) 01 No. Equalisation tank in RCC construction (Retention time minimum 06 hrs.) (v) 01 lot of air grid of UPVC/HDPE for equalisation tank. (vi) 02 Nos. Air blower (1 working + 1 standby) (vii) 1 No Anoxic chamber of MS, epoxy painted from both sides with mixer & media (viii) 02 Nos. MBBR reactor tanks of MS, epoxy painted from both sides with media, SS Air Grid & riser pipes. (ix) 01 No. tube settler tank of MS, epoxy painted from both sides with media (x) 2 Nos recirculation pumps (xi) 02 Nos hypo solution tank of suitable capacity. (xii) 04 Nos. hypo solution dosing pumps (xiii) 02 Nos filter feed pumps.(xiv) 01 No Dual Media filter with media and tank in MS bituminous paint. (xv) 01 No Activated Carbon filter with media and tank in MS bituminous paint. (xvi) 01 No Chlorine contact cum filter feed tank of MS, epoxy painted from both sides. (xvii) 01 No. Treated water tank in RCC construction. (xviii) 01 No electrical control panel for STP operation. (xix) 01 lot of necessary valves, pressure gauges, level control switches, piping & instrumentation. (xx) 01 lot of cabling to interconnect STP panel with various drives. (xxi) 6 Nos sludge drying beds. (xxii) Necessary foundations for electro mechanical equipments.
Item No. 74 Contd… (xxiii) Earthing complete with galvanised steel earth plate electrode size 600mm x 600mm x 6.0 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized earth lead wire 4.0 mm dia by means of bolts, nuts and washers of galvanized iron including GI protection pipe light grade 15 mm bore connected to main earth wire on pole or control board and GI pipe medium grade 20 mm bore for watering funnel with wire mesh, PCC chamber pit with PCC (1:3:6) type C-1, RCC cover with frame in PCC 1:2:4 type B-1 reinforced with 8mm TMT bars @75c/c, excavation and earth work all as shown in electrical plate No 03 of SSR- 2009 Part -I connected to earthing test point complete all as specified or indicated including testing on completion. - 6 sets of 02 earths. (xxiv) One No digital raw sewage flow meter & one No digital liquid flow meter for treated water. (xxv) Suitable arrangement for lifting of sewage from collection chamber to stilling chamber through gravity/pumping. NOTE : (a) All water retaining structures are to be designed and constructed with M-30 grade concrete. (b) The contractor has to give two years warranty for the sewage treatment plant from the date of completion. (c) The contractor has to give minimum 15 years guarantee for MBBR membrane from OEM. (d) All bus bars shall be of 'copper'. (e) All MS and RCC tanks shall be covered with 75mm x 75mm chain link wire mesh with GI wire of not less than 4mm dia. The wire mesh shall be fixed with GI nuts and bolts of suitable size to 50x50x6mm MS angle iron frame fixed over the tank wall. The size of angle iron frame shall be as per the sizes of various tanks specified. The frame shall be fixed to tank wall with suitable size of FI hold fast as directed by GE. (f) All RCC constructions shall be as per various drawings mentioned in list of drgs.
Item No. 76 : Supply, installation, testing and commissioning of submersible pumping set, electric driven 3 phase, open well type, minium discharge 208 LPM, 20m head and suitable capacity of pump including all accessories with & including submersible cable of suitable size & length so as to connect pumping set with starter complete all as specified and as directed.
Item No. 77 : BLANK
EXTERNAL ELECTRIC SUPPLY, SIREN WORKS
Item No. 78 : Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mPa working pressure, complete all as specified and as directed.
Item No. 79 : Cable XLPE insulated screened PVC bedded, galvanised steel strip / wire armoured, electric power cables (Heavy Duty) with stranded aluminium conductor, 11000 Volts grade of size 3 core 150 Sqmm suitable for earthed system, complete all as specified and directed.
Item No. 80 : Cable XLPE insulated screened PVC bedded, galvanised steel strip / wire armoured, electric power cables (Heavy Duty) with stranded aluminium conductor, 11000 Volts grade of size 3 core 95 Sqmm suitable for earthed system, complete all as specified and directed.
Item No. 81 : Transformer step down 11 KV/ 433V outdoor type copper wound with necessary, standard fittings of capacity 500 KVA, 3 - Phase, 4 -Wire, 50 Cycles, vector group DYN - 11 having primary (HT) Voltage of 11 KV and secondary (LT) voltage of 433V off load tap changing gear to provide volts with tapping on primary side having steps of + 2.5 % from (+) 5 % to (-) 7.5 % in equal steps of 2.5% each so as to vary voltage on secondary side, including first fill of transformer oil, the transformer shall be delta connected on 11 KV side & star connected on secondry side with neutral brought out incl provn of cable termination box on HV (delta connection) side & LT cable box on LV (Star connection) side, mounted on platform of size not less than 3x2.5x1.2m including chain link fencing around the platform with 01 No angle iron gate, openable type, including two coats of synthetic enamel paint over a coat of primer on exposed steel surface & two coats of white wash on cement work, complete all as specified and directed at site. (Transformer conforming to IS-1180 Part-I)
Item No. 82 : XLPE insulated screened PVC bedded, galvanised steel strip/ wire armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 400 sqmm 3½ core, complete all as specefied and directed.
Item No. 83 : All as per item No. 82 here-in-before but size 300 sqmm 3½ core
Item No. 84 : All as per item No. 82 here-in-before but size 185 sqmm 3½ core
Item No. 85: All as per item No. 82 here-in-before but size 120 sqmm 3½ core
Item No. 86 : All as per item No. 82 here-in-before but size 70 sqmm 3½ core
Item No. 87 : All as per item No. 82 here-in-before but size 35 sqmm 3½ core
Item No. 88 : All as per item No. 82 here-in-before but size 25 sqmm 4 core
Item No. 89 : All as per item No. 82 here-in-before but size 10 sqmm 4 core
Item No. 90 : All as per item No. 82 here-in-before but size 10 sqmm 2 core
Item No. 91 : All as per item No. 82 here-in-before but size 6 sqmm 4 core
Item No. 92 : PVC insulated PVC sheathed copper conductor industrial cable 1100 volts grade of size 2.5 sqmm 2 core, complete all as specefied and directed.
Item No. 93 : 75mm bore, high density polyethylene (HDPE) pipe of pressure rating 6 Kg/sqcm complete all as specified and as directed.
Item No. 95 : MS junction box made out of 2 mm thick sheet of size 300mm x 250mm x 200mm with TPN aluminium busbar with and including MCB, 'C' curve, SP, 06 Amp - 01 No. including incoming and out going connections with necessary welding work, clamps and mounting on poles etc complete all as specefied and as directed. (Ext Elect & STP)
Item No. 96 : Supply, fixing, installing, commissioning and testing of power factor improvement static condensor (capacitor bank) of capacitor 240 KVAR (50x2+20x5+5x8) with MPP-H capacitor including inter connection with LT panel with appropriate size of electric cable indoor type factory made, weather proof, dust and vermin proof (IP55) including MCCB 4 pole ,400 Amps with breaking capacity not less than 36KA suitable for 1100 volts grade 3 phase 50 HZ AC supply floor mounted, fabricated out of 2mm thick MS sheet welded on 40x40x6 mm angle iron frame/base of appropriate size and having 4 Nos. angle iron legs made out of 40x40x6mm, 60 cm long angle iron below frame with front door and back opening having locking arrangement pre-wired with copper conductor PVC insulated cable/extension strip and connected with suitable size thimbles, lugs duly embedded in ground in PCC 1:3:6 of suitable including locking arrangement suitable for mounting with required sheet metal enclose, thimbles, all as specified and as directed. NOTE: All electric incoming and outgoing connections shall be with PVC insulated multi stranded copper wire of suitable size in PVC flexible conduit medium grade of suitable size.
Item No. 97 : Cable route indicator showing "HT U/G cable 11 KV/LT Cable" and route of cable with arrow made out of CI in suitable eliptical shape and fixed in MS rod 12 MM dia 70 CM long (all word embosed) and embedded in PCC block of size 30x30x30cm in ground complete all as specified and as directed.
Item No. 98 : Decorative post top lantern LED luminaire with defuser and painted spun aluminium deflector fitting 20W fixed on gate pillers, complete all as specified and as directed. Make: C&S Electric Cat Part No.LTGLC20WHPLED/W or equivalent make as mentioned in Appendix 'B'.
Item No 102 : Rubber matt of 1 mtr x 2 mtr x 10 mm size suitable for insulator of electricity,confirming to IS, complete all as specified and as directed.
Item No. 103 : Rubber matt of 1 mtr x 2 mtr x 19 mm size suitable for insulator of electricity,confirming to IS, complete all as specified and as directed.
Item No.104 : Electric rubber hand gloves 11 KV capacity ,confirming to IS, complete all as specified and as directed.
SOLAR WATER HEATING SYSTEM WORKS
Item No. 105 : Supply, installation, testing and commissioning of solar water heater with heat exchanger type, conforming to IS 12933 & 13129 for cold region of 200 litre/ day capacity with electric heating backup of 6 KW and rotational moulded polyethylene water storage tank (cylindrical vertical tank with close top) of 500 Ltr capacity, triple layer as make up water tank including 20mm dia brass float valve, SS Puff insulated hot water collecting tank of suiatable capacity, hoisted and fixed in position on suitable steel staging as directed by GE complete all as specified and as directed. NOTE :- (i) The system shall be tested on completion to ensure that 200 litres of water at 60 Degree centigrade is available in hot water tank on normal day in cold season. (ii) All other pipe/civil work, electrical work, providing electric connection with wire, MCB, conduit etc as per manufacturer's instruction all as required shall deemed to be included in unit rate quoted. (iii) Normal water pipes and accessories from and including cold water make up tank upto & including hot water SS tank, all other pipe/civil work, electrical work, providing electric connection with wire, MCB, conduit etc as per manufacturer's instruction all as required shall deemed to be included in quoted unit rate.
SUMMAR APPLIANCES WORKS
Item No. 106 : Supply, installing and testing of frost free refrigerator electirc driven (230 Volts single phase, 50Hz supply) (3 star BEE rating) Energy efficient compressor, working on R-134 a or superior environment friendly refrigerant, puf insulated body, having normal storage capacity not less than 250 litres, double door type complete all as specified and as directed.
Item No 107 : Heavy duty PVC stands of apprpriate size for placing/ staging of refregirators as in item No-106 here-in-before, complete all as specified and as directed.
Item No 108 : Supply, Installing and testing desert cooler with metal body, electric driven having nominal air flow capacity of 4000 cum per hour, three speed, tank capacity 50 ltr operating with AC single phase, 230 votls, 50 Hz supply with & including 3 core 1.5sqmm copper conductor cord with 3 pin, 5 Amp plug top, complete all as specified and as directed.
Item No. 109: Supplying, installation, testing and commissioning of voltage stabilizer wall mounted, of capacity 2 KVA, for automatic operation, AC Single phase 230 volts, 50 Hz, indoor type, naturally air cooled, with copper wound buck and boost type with high and low voltage cut off 2 -3 minute delay, relay with input variation between 160 V to 280 V and out put voltage of 230 V ± 2.5 % with 95% efficiency at full load IC controlled with electronic relay and 2 metre long copper flexble 3 core cord of size 10/0.0076,single phase, complete all as specified and as directed.
Item No 110 : All as per item No.- 109 here-in-before but 4 KVA.
Item No 111 : Earthing with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick, burried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4mm earth lead by means of bolts, nuts check nuts and washers of galvanized iron or steel with protection pipe of GI, medium grade 15mm bore, watering pipe 20mm bore of GI medium grade, earth plate surrounded by alternate layer of coal dust and common salt 15 cm thick each layer all as per electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified or indicated and testing on completion including funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sqm) and frame including all excavation and earth work etc. all as specified or indicated including testing on completion. Note : (i) Earth chamber shall be constructed at least 1.50 metre away from the top of earth electrode, the earth pit and pipe for watering shall be provided in slanting manner.
Item No. 112 : Earthing with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick, burried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron 32x6mm earth strip by means of bolts, nuts check nuts and washers of galvanized iron or steel with protection pipe of GI, light grade 40mm bore, watering pipe 20mm bore of GI medium grade, earth plate surrounded by alternate layer of coal dust and common salt 15 cm thick each layer all as per electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified or indicated and testing on completion including funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sqm) and frame including all excavation and earth work etc. all as specified. NOTE :- 1. Earth chamber shall be constructed at least 1.50 metre away from the top of earth electrode, the earth pit and pipe for watering shall be provided in slanting manner. 2. Cost of 7.5m length of GI strip & GI protection pipe included in the rate of this item. Extra length will be measured and paid for separately.
ELECTRIC SIREN WORKS
Item No. 113 : Supply and fix electric motor siren conforming to IS-1941 suitable for three phase 415 volts supply, with 1 HP motor and able to deliver 143 DB noise level. Siren shall have an automatic equipment for producing a warbling with 01 No of DOL starter (with over load and single phase preventor feature), ON/ OFF & TRIP indication lamp,suitable contactor etc for 1 HP motor with 1.5 Km audible range, complete all as specified and as directed. NOTE:-Siren shall have an automatic equipment for producing a warbling note.
Item No. 114 : Sheet metal enclosure for MCBs triple pole and neutral, 4 way with 200 amps rated bus bars, double door with and including 01 No MCB TPN 32Amp 'C' curve ,complete all as specified and as directed.
MECH LAUNDRY
Item No. 115 : Supply, installation, commissioning and testing of commercial washing machine with inbuilt hydro extractor of capacity 30 Kg (per charge), front loading, having capacity 30 kg with & including inner basket, outer drum, front loaded fabricated out of high quality 304 grade stainless steel, fully automatic control panel provided with automatic forwarding and reversing timer, digital timer, temperature controller, indicator, Washing machine shall have provision for driven by triangular belt for best efficiency, simple operation, with start & stop buttons and LED display lights, all stainless steel parts polished in gloss finish and all mild steel parts are painted with epoxy paint and have 3 coats of epoxy primer layer for long lasting and heavy duty operation, automatic steam heated including electric motor of suitable HP, with starter, operating on 415 volts, 3 Phase, 50 Hz, AC supply and all other components, parts, fixtures & accessories like valves for water & steam inlet and drain etc complete all as specifeid & as directed. Make : STEFAB, FABCARE, SUPERSHINE, RAMSON, PRECISON FABRICATING ENGINEERS.
Item No. 117 : Supply, installation, commissioning and testing of commercial fully automatic drying tumbler of capacity 30 Kg (per charge) front loading type, steam heated with and including inner basket made of high quality stainless steel, double wall glass wool insulated, outer body made of mild steel, fully automatic, controlled limit switch and motor protection relay for safety, auto shut down in case of any fault for protection, all stainless steel parts are polished in gloss finish and all mild steel parts painted wtih epoxy paint and have 3 coats of epoxy primer layer for long lasting and heavy duty operation, state of the art control panel also including electric motor of suitable HP, with starter, operating on 415 volts, 3 phase, 50Hz, AC supply and all other components parts, fixture and accessoreis like valve for steam inlet and drain, waste air exhaust and self lint screen etc complete all as specifeid & as directed. Make : STEFAB, FABCARE, SUPERSHINE, RAMSON, PRECISON FABRICATING ENGINEERS.
PHASE-III (SCHEDULE 'A' PART-II) MANNING AND OPERATION OF 1 STP :- The period of completion of this Part is 33(Thirty Three) months and date of commencement will be immediately after certified date of completion of Phase-II(Part-I)
Item No 01: Manning, operation and maintenace (other than items/equipments covered by defects liability period) of sewage treatment plant of capacity 100 KLD in the two shifts of 08 hours each including Sunday and holidays with all consumable materials including chemicals as required but excluding electricity and water, complete all as directed just after completion of work as per date mentioned in work order to be placed by GE.The Manning, operation and maintenance shall deemed to be included the following :-
(a) : Repair to system in case of break down (due to normal wear & tear which is not included in the defect liability period of the firm), within 24 hours (b) Repairs to electrical eqpt, accessories as and when required. (c) Daily, weekly, monthly, quarterly, half yearly and yearly comprehensive maintenance including cleaning of bar screen , grit chamber etc to be carried out and keeping records thereof (d) In case of failure noticed more than 24 hrs, recovery shall be affected @ Rs 500/- per hour beyond 24 hours. (e) Attendence register for persons deployed by the contractor and daily running log sheets for STP shall be maintained (f) To provide additional manpower for rectification of major problems and cleaning of tanks etc.(g) All types of T& P required for day to day requirement shall lbe provided by contractor. (h) Treated plant to be tested periodically and record shall be maintained.(j) All types of transportation if reqd for handling materials/eqpts etc shall be provided by the contractor. (k) All types of fire eqpts provided in the installations shall be maintained and operated properly . (l) All electrical fittings and fixtures shall be maintained and contractor shall be responsible for any damage. (m) All types of water tanks incl flushing tanks shall be maintained. (n) All installations and surroundings shall be kept neat and clean all the time and security checks shall be carried daily. (o) All tanks shall be cleaned twice in a year and dates of cleaning shall be marked on tanks. (p) In case of any damage, misuse, mishandling of govt property , contractor shall be held responsible for lthe same.(q) Dress code shall be maintained for employees for working in M & O of STP. (r) Medical assistance shall be provided by the contractor to the employees as and when requred. (s) All safety eqpts such as breathing apparatus, safety belt, air hose respiratory, portable lighting eqpt, driver suit etc for working hazardous condition shall be provided by contractor. (t) First Aid box with basic medicines shall be kept in main installation by the contractor. (u) Misuse of electricity and water shall be penalised and effective recovery shall be made by the department for the same.
Item No. 02 : All as per item No.- 01 here-in-before but for 11(Eleven) months,immediately after certified date of completion of Item No-01.
Item No. 03 : All as per item No.- 01 here-in-before but for 02(Two) months,immediately after certified date of completion of Item No-02.
Item No. 04 : Manning, operation and maintenace of sewage treatment plant of capacity 100 KLD in the two shifts of 08 hours each including Sunday and holidays with all consumable materials including chemicals as required but excluding electricity and water, complete all as directed just immediately after certified date of completion of Item No-03 of work as per date mentioned in work order to be placed by GE.The Manning, operation and maintenance shall deemed to be included the following :-
(a) : Repair to system in case of break down (due to normal wear & tear ) within 24 hours. (b) Repairs to electrical eqpt, accessories as and when required. (c) Daily, weekly, monthly, quarterly, half yearly and yearly comprehensive maintenance including cleaning of bar screen , grit chamber etc to be carried out and keeping records thereof (d) In case of failure noticed more than 24 hrs, recovery shall be affected @ Rs 500/- per hour beyond 24 hours. (e) Attendence register for persons deployed by the contractor and daily running log sheets for STP shall be maintained (f) To provide additional manpower for rectification of major problems and cleaning of tanks etc.(g) All types of T& P required for day to day requirement shall lbe provided by contractor. (h) Treated plant to be tested periodically and record shall be maintained.(j) All types of transportation if reqd for handling materials/eqpts etc shall be provided by the contractor. (k) All types of fire eqpts provided in the installations shall be maintained and operated properly . (l) All electrical fittings and fixtures shall be maintained and contractor shall be responsible for any damage. (m) All types of water tanks incl flushing tanks shall be maintained. (n) All installations and surroundings shall be kept neat and clean all the time and security checks shall be carried daily. (o) All tanks shall be cleaned twice in a year and dates of cleaning shall be marked on tanks. (p) In case of any damage, misuse, mishandling of govt property , contractor shall be held responsible for lthe same.(q) Dress code shall be maintained for employees for working in M & O of STP. (r) Medical assistance shall be provided by the contractor to the employees as and when requred. (s) All safety eqpts such as breathing apparatus, safety belt, air hose respiratory, portable lighting eqpt, driver suit etc for working hazardous condition shall be provided by contractor. (t) First Aid box with basic medicines shall be kept in main installation by the contractor. (u) Misuse of electricity and water shall be penalised and effective recovery shall be made by the department for the same.
Total amount of Schedule 'A' Section-XI
SKYLARK INDUSTRIES
Sant Construction Co.
A S CONSTRUCTION CO.
SOM BUILDERS
M/s Jatindra Construction Company
M/s Madan Lal Bansal and Co. Contractors Pvt. Ltd.
Beant Construction Co Pvt Ltd
Ktech Engineer Builders Co. Pvt. Ltd
Komal Buildcon Pvt. Ltd.
DES RAJ AND SONS BUILDERS PVT LTD
PK Constructions
SAR AGENCIES
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid