Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC | ₹21.0 L Quoted ₹24.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹27.6 LRejected-AOC | ₹27.6 L | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | M/S HINA ELECTRICALS L1 | DURGESH CHANDEL L2 |
|---|---|---|---|---|---|
| 1.00The work of safe carriage of the following material from CB Ganj store center to work site under the jurisdiction UNDER EUDC Bareilly Approx. distance upto 0-30 Km. Including safe loading and unloading. | |||||
| 1.01 | 11 KV CURRENT TRANSFORMER for suitable for different Switch gear Pannels of Diff. ratio and make | 16 | Nos. | 50 ₹800 | 55 ₹880 |
| 1.02 | 11 KV POTENTIAL TRANSFORMER | 3 | Nos. | 50 ₹150 | 55 ₹165 |
| 1.03 | 11 KV CAT-A ENERGYMETER | 2 | Nos. | 50 ₹100 | 55 ₹110 |
| 2.00SUPPLY OF FOLLOWING MATERIALS FOR 11 KV WORK | |||||
| 2.01 | SUPPLY OF 11 KV PANEL O/C + E/F IDMT Relay WITH RETROFITTING ARRANGEMENT | 5 | NO | 25,000 ₹1.3 L | 27,500 ₹1.4 L |
| 2.02 | SUPPLY OF 11 KV PANEL MASTER RELAY WITH RETROFITTING ARRANGEMENT | 5 | NO | 8,000 ₹40,000 | 8,500 ₹42,500 |
| 2.03 | SUPPLY OF HT HRC FUSE FOR PT OF APPROPRIATE RATING | 10 | NO | 300 ₹3,000 | 350 ₹3,500 |
| 2.04 | SUPPLY OF HRC FUSE OF DIFFERENT RATING | 50 | NO | 50 ₹2,500 | 60 ₹3,000 |
| 2.05 | SUPPLY OF 11 KV VCB CHARGING MOTOR OF APPROPRIATE RATING | 10 | NO | 18,000 ₹1.8 L | 20,000 ₹2 L |
Tender Value
₹25 L
EMD Value
₹25,000
Closing Date
7 Jan 2025, 5:00 pmClosed
SE EUDC
35-B RAMPUR GARDEN BAREILLY
ELECTRICAL WORK UNDER EUDC BAREILLY
2024_MVVNL_982355_2
T-60/EUDCB/2024-25
Open Tender
Electrical Works
365 days
EUDC BAREILLY
AS PER TENDER FORM
3 documents required · 3 mandatory
₹3,540
SE EUDC
₹25,000
6 Feb 2026
11 Dec 2024
8 Jan 2025
11 Dec 2024
7 Jan 2025
11 Dec 2024
Amount
The work of safe carriage of the following material from CB Ganj store center to work site under the jurisdiction UNDER EUDC Bareilly Approx. distance upto 0-30 Km. Including safe loading and unloading.
11 KV CURRENT TRANSFORMER for suitable for different Switch gear Pannels of Diff. ratio and make
11 KV POTENTIAL TRANSFORMER
11 KV CAT-A ENERGYMETER
SUPPLY OF FOLLOWING MATERIALS FOR 11 KV WORK
SUPPLY OF 11 KV PANEL O/C + E/F IDMT Relay WITH RETROFITTING ARRANGEMENT
SUPPLY OF 11 KV PANEL MASTER RELAY WITH RETROFITTING ARRANGEMENT
SUPPLY OF HT HRC FUSE FOR PT OF APPROPRIATE RATING
SUPPLY OF HRC FUSE OF DIFFERENT RATING
SUPPLY OF 11 KV VCB CHARGING MOTOR OF APPROPRIATE RATING
SUPPLY OF MCB OF APPROPRIATE RATING
SUPPLY OF AUXILLARY SWITCH OF APPROPRIATE RATING
SUPPLY OF ANTIPUMPING RELAY
SUPPLY OF SPOUT
SUPPLY OF BUSBAR AS PER REQUIREMENT/DRAWING
SUPPLY OF JAW FOR 11 KV VCB TROLLEY
SUPPLY OF INDICATOR
SUPPLY OF AMPERE METER
SUPPLY OF VOLT METER
SUPPLY OF TNC SWITCH
SUPPLY OF LOCAL /REMOTE SWITCH
SUPPLY OF BUZZER
SUPPLY OF CLOSING COIL (24 V D.C)
SUPPLY OF TRIPPING COIL (24 V D.C)
SUPPLY OF VACCUM INTERRUPTOR for Suitable for diff. make 11 KV Switch gear pannel.
Erection of 11 KV work
REPLACEMENT OF DEFECTIVE 11 KV CURRENT TRANSFORMERfor suitable for different Switch gear Pannels of Diff. ratio and make
REPLACEMENT OF DEFECTIVE 11 KV POTENTIAL TRANSFORMER
REPLACEMENT OF DEFECTIVE 11 KV PANEL O/C + E/F IDMT Relay WITH RETROFITTING ARRANGEMENT
REPLACEMENT OF DEFECTIVE 11 KV PANEL MASTER RELAY WITH RETROFITTING ARRANGEMENT
REPLACEMENT OF DEFECTIVE HT HRC FUSE FOR PT OF APPROPRIATE RATING
REPLACEMENT OF DEFECTIVE HRC FUSE OF DIFFERENT RATING
REPLACEMENT OF 11 KV VCB CHARGING MOTOR OF APPROPRIATE RATING
REPLACEMENT OF DEFECTIVE/BURNT MCB OF APPROPRIATE RATING
REPLACEMENT OF DEFECTIVE/BURNT AUXILLARY SWITCH OF APPROPRIATE RATING
REPLACEMENT OF DEFECTIVE ANTIPUMPING RELAY
REPLACEMENT OF DEFECTIVE SPOUT
REPLACEMENT OF DEFECTIVE BUSBAR AS PER REQUIREMENT/DRAWING
REPLACEMENT DEFECTIVE JAW FOR 11 KV VCB TROLLEY
REPLACEMENT OF DEFECTIVE INDICATOR
REPLACEMENT OF DEFECTIVE AMPERE METER
REPLACEMENT OF DEFECTIVE VOLT METER
REPLACEMENT OF DEFECTIVE TNC SWITCH
REPLACEMENT OF DEFECTIVE LOCAL /REMOTE SWITCH
REPLACEMENT OF DEFECTIVE BUZZER
REPLACEMENT OF DEFECTIVE CLOSING COIL (24 V D.C)
REPLACEMENT OF DEFECTIVE TRIPPING COIL (24 V D.C)
REPLACEMENT OF DEFECTIVE VACCUM INTERRUPTOR for Suitable for diff. make 11 KV Switch gear pannel.
SERVICING AND REPAIRING OF MECHANICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 11 KV BREAKER of diff makes .
SERVCING AND REPAIRING OF ELECTRICAL SYSTEM FOR PROPER METERING, OPENING, CLOSING & TRIPPING OF 11 KV BREAKER INCLUDING PROVIDING OF NECESSARY INTERNAL WIRING, LUGS, FUSES, FERRULES OF APPROPRIATE RATING AND COLOUR CODING AND OTHER NECESSARY ACCESSORIES. BATTRERY AND BATTERY CHARGER OVERHAULING & MAINTENANCE.
The work of safe carriage of the following material from CB Ganj store center to work site under the jurisdiction of UNDER EUDC Bareilly Approx. distance upto 0-30 Km. Including safe loading and unloading.
33 KV BUS ISOLATOR
ACSR DOG CONDUCTOR
33 KV LIGHTENING ARRESTOR
33 KV FUSE SET
33 KV LINE ISOLATOR
33 KV CURRENT TRANSFORMER 400/200/1 OR 200/100/1
SUPPLY OF FOLLOWING MATERIALS FOR 33 KV WORK
SUPPLY OF 33 KV PANEL O/C + E/F IDMT Relay WITH RETROFITTING ARRANGEMENT
SUPPLY OF 33 KV PANEL MASTER RELAY WITH RETROFITTING ARRANGEMENT
SUPPLY OF 33 KV PANEL AUXILARY Relay WITH RETROFITTING ARRANGEMENT
SUPPLY OF CLOSING COIL (24 V D.C)
SUPPLY OF TRIPPING COIL (24 V D.C)
SUPPLY OF MAIN CONTACT BLOCK OF BREAKER
SUPPLY OF TNC SWITCH
SUPPLY OF CONTROL CABLE FORM PANEL TO VCB 2*2.5 SQ MM ARMOURED CABLE
SUPPLY OF CONTROL CABLE FORM PANEL TO VCB 4*2.5 SQ MM ARMOURED CABLE
SUPPLY OF VCB CHARGING MOTOR OF APPROPRIATE RATING
SUPPLY OF MCB OF APPROPRIATE RATING
SUPPLY OF AUXILLARY SWITCH OF APPROPRIATE RATING
SUPPLY OF ANTIPUMPING RELAY
DEFECTIVE LED INDICATOR
SUPPLY OF AMPERE METER
SUPPLY OF VOLT METER
SUPPLY OF LOCAL /REMOTE SWITCH
SUPPLY OF BUZZER
SUPPLY OF WTI METER
SUPPLY OF OTI METER
SUPPLY OF MAGNETIC OIL GAUGE OF POWER TF
SUPPLY OF BUCHOLTZ RELAY
SUPPLY OF MAIN CONTACT BLOCK OF TRANSFORMER
SUPPLY OF BREATHER WITH SILICA GEL
SUPPLY OF NO,NC CONTACT SUITABLE FOR 33 KV Breaker .
SUPPLY OF SILICA GEL
ERECTION OF 33 KV WORK.
ERRECTION OF 33 KV BUS ISOLATOR
STRINGING OF ACSR DOG CONDUCTOR
ERRECTION OF 33 KV LIGHTENING ARRESTOR
ERRECTION OF 33 KV FUSE SET
ERRECTION OF 33 KV CURRENT TRANSFORMER 400/200/1 OR 200/100/1
INSTALLATION OF 33 KV line isolator 33 KV
REPLACEMENT OF DEFECTIVE 33 KV PANEL O/C + E/F IDMT Relay WITH RETROFITTING ARRANGEMENT
REPLACEMENT OF DEFECTIVE 33 KV PANEL MASTER RELAY WITH RETROFITTING ARRANGEMENT
REPLACEMENT OF DEFECTIVE 33 KV PANEL AUXILARY Relay WITH RETROFITTING ARRANGEMENT
REPLACEMENT OF DEFECTIVE CLOSING COIL (24 V.D.C.)
REPLACEMENT OF DEFECTIVE TRIPPING COIL (24 V.D.C.)
REPLACEMENT OF DEFECTIVE MAIN CONTACT BLOCK OF BREAKER
REPLACEMENT OF DEFECTIVE TNC SWITCH
LAYING OF DEFECTIVE CONTROL CABLE FORM PANEL TO VCB 2*2.5 SQ MM ARMOURED CABLE
LAYING OF DEFECTIVE CONTROL CABLE FORM PANEL TO VCB 4*2.5 SQ MM ARMOURED CABLE
REPLACEMENT OF VCB CHARGING MOTOR OF APPROPRIATE RATING
REPLACEMENT OF DEFECTIVE/BURNT MCB OF APPROPRIATE RATING
REPLACEMENT OF DEFECTIVE/BURNT AUXILLARY SWITCH OF APPROPRIATE RATING
REPLACEMENT OF DEFECTIVE ANTIPUMPING RELAY
REPLACEMENT OF DEFECTIVE LED INDICATOR
REPLACMENT OF DEFECTIVE AMPERE METER
REPLACMENT OF DEFECTIVE VOLT METER
REPLACMENT OF DEFECTIVE LOCAL /REMOTE SWITCH
REPLACMENT OF DEFECTIVE BUZZER
REPLACEMENT OF DEFECTIVE WTI METR
REPLACEMENT OF DEFECTIVE OTI METER
REPLACEMENT OF DEFECTIVE MAGNETIC OIL GAUGE OF POWER TF
REPLACEMENT OF DEFECTIVE BUCHOLTZ RELAY
REPLACEMENT OF DEFECTIVE MAIN CONTACT BLOCK OF TRANSFORMER
REPLACEMENT OF DEFECTIVE BREATHER WITH SILICA GEL
REPLACEMENT OF SILICA GEL
Replacement of defective NO,NC CONTACT SUITABLE FOR 33 KV Breaker .
SERVICING AND REPAIRING OF MECHANICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 33 KV VCB
SERVICING OF ELECTRICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 33 KV BREAKERS INCLUDING PROVIDING NECESSARY INTERNAL WIRING, LUGS, FERRULES OF APPROPRIATE RATING AND COLOUR CODING & SERVICING MECHANICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 33 KV BREAKERS & SERVICING 33 KV PANEL FOR PROPER OPERATION OF OPENING, CLOSING, TRIPPING, ALARM, INDICATION OF BREAKER INCLUDING PROPER INTERNAL WIRING OF PANELS AND PROPER WIRING BETWEEN PANELS, DC CHARGER, 33 KV BREAKER, Control cable, 33 KV CTs, 33 KV PTs, POWER TRANSFORMER OIL TEMPRATURE INDICATOR, WINDING TEMPRATURE INDICATOR, OIL LEVEL INDICATOR, BUCHOLTZ RELAY ETC WITH PROPER CONTOL CABLE, LUGS, FERRULES OF APPROPRIATE RATING AND COLOUR. MAINTENANCE OF LIGHTING ARRANGEMENT IN SWITCHYARD & CONTROL ROOM ALSO AND OTHER IMPORTANT WORKS RELATED TO 33/11KV SUBSTAION
REPLACEMENT OF JARJAR CONDUCTOR INCLUDING HEAVY DUTY PG CLAMP, HEAVY DUTY CONECTOR, ISOLATER JAW ETC COMPLETE
RECTIFICATION OF LEAKAGE OF 05 MVA TRANSFORMER
RECTIFICATION OF LEAKAGE OF 10 MVA TRANSFORMER
Centrifuging of 10 MVA T/F
Centrifuging of 5 MVA T/F
Painting of All structure of switch yard such as terminal gantry, Bus gantry, Line Isolator, Bus Isolators, Fuse sets, CT Structures, Breaker Structures, LA Structures, etc. with one code of red oxide and two cote of Aluminium paint
Note:- All the above quantity of each work is assumed as per previous experience .The Quantity of any item of work may very from 0 to maximum number within the value of tender
DURGESH CHANDEL (BID ID -4837770)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid