| 1 | 1₹15.3 LAccepted-Finance 1 2 VELLAPPARA PALLISSERY HOUSE PUNNAYURKULAM POST MARPADI MALAPPURAM | MARPADI | MALAPPURAM | KERALA | 1 | Accepted-Finance L1 | |
| 2 | 2₹15.5 L+₹20,000 (1.30%)Accepted-Finance | 2 | Accepted-Finance L2 | |
| 3 | 3₹15.6 L+₹23,600 (1.54%)Accepted-Finance 18 398A MUNDAKAYAM MUNDAKKAYAM MUNDAKAYAM KOTTAYAM KERALA 686513 | KOTTAYAM | KERALA | 686513 | 3 | Accepted-Finance L3 | |
| 4 | Rejected-Technical 7 4 GANGAIAMMAN KOIL FIRST STREET VADAPALANI CHENNAI TAMIL NADU 600026 | CHENNAI | TAMIL NADU | 600026 | - | Rejected-Technical Technically NOT qualified |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
12 Feb 2024, 1:25 pmClosed
UNIT HEAD
KEL EDARIKODE
Supply and Installation of Solar Plant at Peruvalloor School in Malappuram District Panchayath
2024_KEL_654605_1
KEL/ KEMG/89/2024
Open Tender
Electrical Works
Item Rate
90 days
KEL EDARIKODE
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,950
Yes
₹50,000
Yes
13 Feb 2024
5 Feb 2024
13 Feb 2024
5 Feb 2024
12 Feb 2024
5 Feb 2024
5 Feb 2024 - 12 Feb 2024
Amount
Supply and providing wall mounted on grid solar Power Conditioning Unit (PCU) of 200-1000 V DC Input voltage range or nearest range and 400V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency and adustiable for connecting time to grid as per KSEB norms, including Data Monitoring System complete with accessories wifi/LAN connecting and connected application software etc. fixing on wall using wall brackets and giving all connection as required (Make Growatt, Havells, Sofar, Evvo, V-Guard))
OD223505/2023-2024 Supply and providing Solar Photovoltaic Module Mono Perc Half Cut of capacity 540 Wp or nearest size, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. fixing on existing steel frame work using nut bolts/screws etc in suitable direction at site condition and giving connection and inter connection wire tied using suitable steel wire tie as per the system string design and direction of department staff (make Vikram, Waaree, Tata, Havells,V- Guard)
Supply and providing wall mounted AC DB for on grid solar system for connecting Inverter AC side consists of a). Poly carbonate Enclosure IP65 protection with trasperant front cover with hinged door and termination arrangement, b). SPD Up1.5kV,Up 335VDC In 20kA, Imax 40kA and giving internal connection using suitable wire, c). 6-32A 4Pole AC MCB for outgoing side, giving all connection and DB fixing on wall using suitabel screws and plugs ets as required.
Supply and providing wall mounted DC DB for on grid solar system for connecting 2Nos solar panel string and DB consists of a). Thermoplastic Enclosure IP65 protection with transparent front cover with hinged/screws door and termination arrangement, b). 2set 20A DC Fuse and Holder for +ve and connector for -ve incomer side, c). 2set SPD 1000V DC Up1.9kV,Ucpv 585VDC, In 15kA, Imax 40kA and giving internal connection using suitable wire, d). 2set of 10 - 20A 2Pole DC MCB for outgoing side, giving all connection and DB fixing on wall using suitable screws and plugs ets as required.
Supplying and drawing 1run x 4 sq. mm PVC insulated tinned copper conductor, single core Solar DC cable in the existing surface / recessed steel/ PVC conduit as required.
Supply and crimping the Male Female MC4 Solar Panel cable connector including crimping and connecting etc as required
Supply & installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB- 6545) and to fix KSEB meters, fuse units etc as required including fixing it on wall, making good the damages colour washing etc. as required.
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing Three phase 4wire KWh meter, 415V, 10 - 100 A range ,electronic type in the existing meter board complete with connections, testing and commissioning etc. as required (including testing if required, test certificate for submitting KSEB).
Supply and wiring with PVC insulated stranded single core copper conductor cables for interconnecting the control devices/ equipment's including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 10Sqmm single run
Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
Supplying and fixing Three phase 4wire KWh Net meter, 415V, 10 - 100 A or nearest range ,electronic type in the existing meter board complete with connections, testing and commissioning etc. as required for charging On grid plant after dismantling the existing KWH meter (including testing if required, test certificate for submitting KSEB).
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 4 Run
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system
Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate
Supply and providing 25x3mm brass bolt
Supply and providing 25x6mm brass bolt
Supply and providing 12x3mm brass bolt
Supply and providing Copper Bounded lightning arrester single spike " Air- termination rod " are placed on top of the structure using suitable base plate and nut bolt and giving connection to existing lightning down conductor etc as required
Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
KSEBL Charge for availing approval from KSEBL and on grid solar system feasibility and charging charge including preparing all necessary documents/ stamp paper agreements for energisation on grid solar to KSEBL if required (Actual amount will be reimbursed on production of receipts)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
SP BUISINESS ASSOCIATES
KALLOOR ELECTRONICS AND LIGHTING PVT LTD
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .