| 1 | L1₹25.4 LAccepted-AOC 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹26.1 L+₹25,608.50 (0.99%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹27.0 L+₹1.2 L (4.48%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹28.0 L+₹2.1 L (8.32%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹28.6 L+₹2.8 L (10.7%)Rejected-AOC 190 B VIJAY BHAWAN SUBHASH CHOWK RATANADA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L5 | Rejected-AOC L5 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
27 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF) No 2 Jodhpur
GE AF) No 2 Jodhpur
REPAIR AND MAINT OF EM INSTALLATION EM EQUIPMENTS AND ALLIED WORKS AND REPAIR AND MAINT OF LT INFRA AND ALLIED WORKS AT AF STN MOUNT ABU AND GURUSHIKAR UNDER AGE EM GE AF NO 2 JODHPUR
2021_MES_469796_1
8274/E8
Open Tender
Civil Works
Lump-sum
300 days
GE AF) No 2 Jodhpur
As per Tender Documents
6 documents required · 6 mandatory
₹500
Yes
₹70,000
Yes
9 Nov 2021
21 Aug 2021
1 Oct 2021
21 Aug 2021
27 Sept 2021
13 Sept 2021
60 days
Amount
Comprehensive maintenance servicing and testing of solar water heating system of 500/750/1000 Ltrs capacity including washing, cleaning of water carrying pipes, scalling inner surfaces with anti scalant liquid solution as directed by Engr-in- charge. Note :- (a) Spares required for replacement shall be measured and paid separately.
Repair to Solar water Tank Of capacity 500/750/1000 Ltrs making Insulation fixed with new ones. Removing Rusted Valves and fixing New one .
Taking out unserviceable solar modules from the site complete all as specified and as directed by Engr-in-charge.
Supply , installation , testing & commissioning Solar Water Heating System ( Flat Plate Collector) including Copper tubes of solar panel ,Aluminum foil absorber, Collector box frame aluminum material, Fiber glass wool insulation , Front Cover glass 4 mm thick seated with Gasket EDPM rubber channel/ silicon glazing seal with necessary connecting accessories to solar plates complete as specified and directed by engineer-in-charge. Capacity 100LPD/125LPD.
Taking down old rusted water distribution galvanised pipes of size 15 mm dia complete all as specified and as directed by Engr-in-charge.
S&F GI pipe of size 15 mm dia of Medium Grade complete all as specified and as directed by Engr-in-charge..
Taking down old unserviceable insulation cover of alluminium foil of size 2.00 mm thick and 50 cm widefrom with 40 mm puff at the working site complete all as specified and as directed by Engr-in-charge.
S&F insulation 50 mm thicker puff with covering 2.00 mm aluminium cover on outer layer complete all as specified and as directed by Engr-in-charge.
Taking down old unserviceable regulating valve of size 15 mm dia complete all as specified and as directed by Engr-in-charge.
S&F flow regulating valve of size 15 mm dia complete all as specified and as directed by Engr-in-charge.
M&L for Welded steel wire fabric supplied and fixed complete to wood or steel members complete all as specified and as directed by Engr-in-charge.
M&L Joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc.without connecting plates, etc complete all as specified and as directed by Engr-in-charge.
M&L for installing ,testing and commisioning of solar water heater tank of capacity 500/750/1000 litre with rust proof polester powder coating on galvanized metal complete all as specified and as directed by Engr-in-charge.
Battery of rating 12 volts having 6 cell ,each cell 2 Volt DC and also rating Amp 180 AH including lead terminals including installation complete all specified and directed by Engineer-in- Charge.
Replacement of V belts any size as required and as directed For DG Sets of any Size complete all as specified and as directed by Engr-in-charge.
Repairs and cleaning of radiators of DG set of capacity of 62.5 KVA and removing the radiators from engine for repair and washing with caustic soda and cleaning with blower including brazing of damaged water tubes/fins complete all as specified and as directed by Engr-in-charge.
Comprehensive Maintenance of DG Set of Capacity 62.5 KVA including checking for loose electrical making them fixed .
S&F Lub Oil Filter of same make as Required in above item no 18
S&F Air Filter Outer-01, Air Filter Inner-01 as per required make as Required in above item no 18.
S&F Battery 12V , 88 AH Make : Exide as Required in above item no18
S&F Fan Belt as Required in above item no 18.
S&F Battery Cable as Required in above item no 18.
S&F digital control panel suitable for 62.5 KVA genset of make Crompton Greaves. as Required in above item no18
Repair to AMF Panel of DG Set 62.5 KVA , Checking for fault And Replacing Faulty Spares complete all as specified and as directed by Engr-in-charge.
S&F MCCB 100 Amp complete all as specified and as directed by Engr-in-charge. Make: Schneider
S&F 80 Amp, 3 Pole Contactor complete all as specified and as directed by Engr-in-charge. Make : Schneider LC1E80
Repair And Maintenance of Lightning protection. Testing for use , Taking out and refixing existing terminal rod and copper strips . Spares And Broken Items will be Paid seperately complete all as specified and as directed by Engr-in-charge.
Supply and fixing single pointed air termination copper rod, 12 mm dia, 300 mm long complete all as specified and as directed by Engr-in-charge.
Supply & fix copper strip 32mm x 6 mm buried in ground with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed by Engr-in-charge.
Supply And Fix Hot Air Blower of capacity of 2KW For Reduce Moisture At Substation At Mt Abu And Gurushikhar complete all as specified and as directed by Engr-in-charge.
Repairs and cleaning of radiators of DG set of capacity of 15 KVA and removing the radiators from engine for repair and washing with caustic sida and cleaning with blower including brazing of damaged water tubes/fins complete all as specified and as directed by Engr-in-charge
Comprehensive Maintenance of DG Set of Capacity 15 KVA including checkimg for loose electrical making then fixed . Disconnecting parts to be serviced, make them fixed after servicing.
S&F Lub Oil Filter of same make as Required
S&F Air Filter Outer-01, Air Filter Inner-01 as per required make
S&F Battery 12V, 88 AH Make : Exide
S&F Fan Belt as Required in above item no 27
S&F Battery Cable as Required in above item no 27
M&L in painting E/M Equipments Including Transformers ,filteration plant , substaion Panels with two Coat enamles complete all as specified and as directed by Engr-in-charge
Excavation in trenches not exc 1.5 meter wide and not exc 1.5 m in depth for foundation of poles/stays cables etc and getting out in the following :- a) Hard/Dense soil
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cms in soil complete all as specified and as directed by Engr-in-charge.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above starting point with :- a) Any type of soil
M & L for painting of two pole structure including cross arms, supports, channels, DO, GOD etc including scrapping old aluminium paint applying one coat of red oxide primer and one coat of aluminium paint to steel structure, applying a coat of exterior emulsion paint of approved make to pole coping complete all as specified and as directed by Engr-in-charge.
Repair and Maintenance of steel tubular pole complete with MS base plate finial taper plug cap bolt, nut, screws etc all as specified for swaged pole of type 410-SP-31, 9 meters long including painting with one coat of red oxide and there after two coats of aluminum paint of approved quality. Including Welding of broken parts complete all as specified and as directed by Engr-in-charge. (Note: Earth work excavation, PCC foundation & cross arms will be measured and paid separately under relevant items of this schedule.)
M&L Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate for foundation of poles complete all as specified and as directed by Engr-in-charge.
M&L PCC 1:3:6 type C1 using 20mm graded stone aggregate for coping of poles/plinth blocks of HT poles etc incl fair finishing the exposed surfaces even and smooth without using extra cement including necessary form work complete all as specified and as directed by Engr-in-charge.
Supply, spread and level ( in trenches ) fine stone dust for cushioning of the U/G cable complete all as specified and as directed by Engr-in-charge.
Supply and lay Bricks class 'B' of old size 230 mm x 115 mm x 75 mm in trenches for cable protection all as specified and as directed.
Relaying of bricks class 'B' of any size laid as cable cover removed from existing trenches complete all as specified and as directed by Engr-in-charge.
S&F earth continuity conductor fixed to wall/or buried in ground or fixed to poles or any other indicated position for loop earthing etc of size 32 x 6 mm complete all as specified and as directed by Engr-in-charge.
Dismantling damaged/unserviceable PCC/RCC/Steel electrical pole of any size alongwith unserviceable cross arms including clamps, bolts, nuts, washers, insulators, brackets etc complete all as specified and as directed by Engr-in-charge.
Supply And Laying LT UG cable, XLPE insulated, steel armoured, 1100 Volts grade in trenches / ducts / through pipes / on poles / roads fixing to the poles through clamps and connecting up, testing and commissioning including taking down old unserviceable LT UG cables, jointing and testing complete all as specified and as directed by Engr-in-charge for the following sizes:- Note: (i) Excavation and earth work, cable covers, sand cushioning will be measured and paid separately under relevent items of this schedule.
(a) 10 Sqmm 4 core
(b) 16 Sqmm 4 core
(c) 25 Sqmm 4/3.5 core
(d) 35/50 Sqmm 3.5 core
(e) 70 Sqmm 3.5 core
(e) 95 Sqmm 3.5 core
S&F lay GI tubing light grade for protection of cable at road crossing including removal of old U/S pipes :-
(a) 40mm bore
(b) 50mm bore
(c) 80mm bore
Cutting, trimming and pruning of trees / tree branches of any girth up to 2.5 sq. Mtrs all around the existing LT/HT overhead lines / surroundings of street light and flood fitting LT poles including cleaning the disturbed area beneath the LT overhead lines and removing the tree branches and debris from the site and depositing where directed by Engr-In-Charge.
Supply, jointing and testing LT straight through joints, outdoor heat shrinkable 1100 Volts grade, suitable for 3.5 core 1.1 KV UG cable of size 50 sq.mm to 95 sq.mm including taking out old unserviceable joints complete all as specified and as directed by Engr-in-charge.
All as per Sl Item No. 46 here-in-before but 4 core, 25 sq.mm to 35 sq.mm size.
All as per Sl Item No. 46 here-in-before but 4 core,10 sq.mm to 16 sq.mm size.
S & F MCCBs 415 V, 4 Pole 16 KA, of following capacities :-
(a) 63 Amps
(b) 100 Amps
(c) 125 Amps
S&F MCCB, 160 Amps, 4 Pole 36 KA ,415 Volts with thermal adjustment complete all as specified and as directed by Engr-in-charge.
S&F MCCB, 200 Amps,4 Pole 36 KA ,415 Volts with thermal adjustment complete all as specified and as directed by Engr-in-charge.
S&F MCCB, 250 Amps,4 Pole 36 KA ,415 Volts with thermal adjustment complete all as specified and as directed by Engr-in-charge.
S&F MCCB, 315 Amps,4 Pole 36 KA ,415 Volts with thermal adjustment complete all as specified and as directed by Engr-in-charge.
S&F MCCB, 400 Amps,4 Pole 36 KA ,415 Volts with thermal adjustment complete all as specified and as directed by Engr-in-charge.
Supply and installing at approved location approved make buckets of 24 gauge galvanised steel, painted white inside and red outside and black on the bottom, inscribed with letters "FIRE" in black and gold including stand fabricated out of sheet metal (16 gauge) shade platform and associated civil works, painting etc as approved by fire authority including the following items: (a) Fire buckets 13.5 ltrs - 04 nos (b) Sand buckets 13.5 ltrs - 04 nos (c ) Fire hooks - 01 no (d) Fire beater - 01 no. (e) Fire alarm bell - 01 no (f) Storage space for 1 cum of sand (g) Axe -01 no. (h) Shawal -01 no.
Supply only ABC stored pressure type fire extinguisher 5 kgs capacity consisting of welded cylinder, squeeze lever discharge valve fitted with pressure indicating guage, internal dischare tube, discharge nozzle suspension bracket, conforming to IS:13849 duly charged with ISI marked mono ammonium phosphate base ABC powder conforming to IS:14609 and pressuirized with nitrogen gas (ISI marked) complete all as specified and as directed by Engr-in-charge. Make: Fire brand.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed by Engr-in-charge.
Ditto as above 57 but 2.5 mm thick for voltage upto 11 KV (size 2x1m) complete all as specified and as directed by Engr-in-charge.
S&F HRC Fuse 315A complete all as specified and as directed by Engr-in-charge.
New generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power leds as light sourcecomplete all as specified and as directed by Engr-in-charge. Make: Havells, CAT Part NO. CORALPT25WLED757PSYMTOPC
S & F digital type voltmeter 0 to 500 volts, 3 phase, 50 Hz complete all as specified and as directed by Engr-in-charge.
S & F digital type ammeter 0 to 200 amps, 3 phase, 50 Hz complete all as specified and as directed by Engr-in-charge.
S & F indicator lamps RYB complete all as specified and as directed by Engr-in-charge.
Repair and maint of bus bar for LT panels of different sizes incl copper strip including taking off old U/S Strips fixing with new strips , fixing with nuts and necssray Connections. Fixing panel gates with proper fixing screws complete all as directed by Engr-in-charge.
(a) S & F copper strip of 32 mm x 6 mm
(b) S & F copper strip of 25 mm x 3 mm
(c) S & F copper strip of 20 mm x 3 mm
S & F automatic light timer switch with nature switch Cat No SWADEEP-02EC12KW3P, infra ray sensore with pre dawn switching off timer, 8 hours of max load capacity of 4KW per phase. Degree of protection confirms to IP 65. Contactor rating - 40 Amps, MCB rating - 63 Amps, 3 Phase with max load 12 KW complete all as directed by Engr-in-charge. Make - Nature switch / Schneider / Siemens
S & F ON load change over switch 415 V in sheet metal enclosures 4 pole of capacity 400 Amps complete all as directed by Engr-in-charge.
S & F ON load change over switch 415 V in sheet metal enclosures 4 pole of capacity 630 Amps complete all as directed by Engr-in-charge.
S & F pin type porcelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two galvanised mild steel spindle, two galvanised iron washers and one galvsnised iron nut, 150 mm height, 150 mm dia for 11000 volts grade complete all as directed by Engr-in-charge.
S & F cross arms brassings supports, clamps and back plates fabricated from structural steels sections incl nuts, bolts, washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as directed by Engr-in-charge.
Danger Notice plate of 1.6mm thick mild steel sheet , vitreous enamelled white, with letters , figures and conventional skull and bones in signal red colour and fixed with M.S clamps , bolts , and nuts of approved size,for LT ,20x15cm size complete all as directed by Engr-in-charge.
Danger Notice plate of 1.6mm thick mild steel sheet , vitreous enamelled white , with letters , figures and conventional skull and bones in signal red colour and fixed with M.S clamps , bolts , and nuts of approved size for HT 25x20cm Size complete all as directed by Engr-in-charge..
M & L for painting of LT panel including scrapping old aluminium paint applying one coat of red oxide primer and one coat of aluminium paint to steel structure, applying a coat of exterior emulsion paint of approved make to pole coping complete all as directed by Engr-in-charge.
Comprehensive Maintenance of DG Set of Capacity 75 KVA including checking for loose electrical Connections making them fixed, cleaning of radiator of DG set, removing the radiators from engine for repair and washing with caustic sida and cleaning with blower including brazing of damaged water tubes/fins . Disconnecting parts to be serviced and make them fixed after servicing.
a) S&F Lub Oil Filter of same make as Required
b) S&F Air Filter Outer-01 , Air Filter Inner-01
c)S & F ` O` Ring Pre Filter
d) S & F Fan Belt
e) S & F Battery Cable
f) S & F Flexible Pipe
g) S & F Water Hose Pipe
h) S & F Sealing Ring
I) S & F Main Supply Fuel Pipe
Comprehensive Maintenance of DG Set of Capacity 125 KVA including checking for loose electrical Connections making them fixed, cleaning of radiator of DG set, removing the radiators from engine for repair and washing with caustic sida and cleaning with blower including brazing of damaged water tubes/fins . Disconnecting parts to be serviced and make them fixed after servicing
a) S&F Lub Oil Filter of same make as Required
b) S&F Air Filter Outer-01 ,Air Filter Inner-01 as per required make
c)S & F `O` Ring Pre Filter
d) S & F Fan Belt
e) S & F Battery Cable
f) S & F Flexible Pipe
g) S & F Water Hose Pipe
h) S & F Sealing Ring
I) S & F Main Supply Fuel Pipe
L C ASSOCIATES
Sona Lakshmi Associate and Developers
M/S JALANDRA CONSTRUCTIONS
M/S Balkishan Panwar Construction
M/S VENUS BUILDER
boon construction company
BAGHELA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .