| Sl No | Description | Qty | Unit | M/s Sopore Engineering Works L1 | Meer Engineers L2 |
|---|---|---|---|---|---|
| 1.00 | Providing, fitting, testing and commissioning of M.S foot valve of 200mm dia fabricated out of M.S plate, square/round bars and pipe pieces etc by required mechanical operations viz., cutting, bending, tapering, shaping, welding and finishing at Lift Irrigation Scheme Ashtangoo:
Body: Fabricated out of 300mm dia and 200mm dia M.S departmental pipe (of size 200mm dia, 150mm long and 300mm dia ×300mm length). The body material has to be shifted from sub-divisional premises to private workshop in a private vehicle.( pipe thickness= 6mm).
Flap/Weight plate: fabricated out of M.S plate of thickness 12mm along with ethylene propylene diamine monomer (EPDM) washer and M.S bottom counter weight plate (6mm thick) complete with proper fitting arrangement and M.S. back stopper.
Hinge: fabricated out of M.S plate of thickness not less than 12mm with required sliding arrangement.
Seat: fabricated out of square/round bar not less than 16mm thick with proper finishing and buffing.
Strainer: fabricated out of 10mm thick square/round bars and MS plate strips top and bottom of angle (50mm) length of bar 250mm.
Top flange: 200mm dia, 12mm thick
Bottom plate: 300mm dia, not less than 12mm thick.
Top plate: Connecting 200mm dia pipe and 300mm dia pipe, 12mm thick.
Coating: The foot valve body should be completely coated with metallic redoxide and enamel paint.
Warranty: One year.
The foot valve should be complete leak proof. The equipment should be installed and tested at site complete. The job also includes providing and fitting of nut bolts of 3kgs of size along with 4mm thick NBR gasket of 300 mm dia . | 2 | Job | 7,500 ₹15,000 Lowest | 11,700 ₹23,400 |
| 2.00 | Repairing of rising main MS pipe of dia 250mm for arresting leakage by way of dismantling of rising main at various joints. The welding (150cm approx.) at various spots is to be carried out by mobile type welding set which includes DG set, welding set, Gas cutter, electric grinder, superior quality electrodes, tata mobile, skilled and unskilled workers for carrying/execution of welding. After welding and repairing the pipe to be aligned and fitted properly as per requirement and tested successfully. The job includes providing and fitting of nuts bolts of 5kgs, 4 No. gaskets of 250mm dia. The job includes all types of carriages viz., head load for shifting of welding set at various spots. | 1 | Job | 6,900 ₹6,900 Lowest | 17,900 ₹17,900 |
Tender Value
Refer Docs
Closing Date
31 Jul 2025, 6:55 pmClosed
Executive Engineer Mech. Irrig. Div. Baramulla
MID Baramulla
Mechanical works to be executed at Lift Irrigation Scheme Ashtangoo of MISD Sopore.
2025_IFC_280315_4
eNIT 14 of 2025-26 MISD Sopore
Open Tender
Repair and Maintenance Works
Item Rate
7 days
Sopore
Please refer Tender documents.
2 documents required · 2 mandatory
₹50
Yes
Executive Engineer Mech. Irrig. Div. Baramulla
Yes
6 Aug 2025
2 Jul 2025
1 Aug 2025
2 Jul 2025
31 Jul 2025
2 Jul 2025
Amount
Providing, fitting, testing and commissioning of M.S foot valve of 200mm dia fabricated out of M.S plate, square/round bars and pipe pieces etc by required mechanical operations viz., cutting, bending, tapering, shaping, welding and finishing at Lift Irrigation Scheme Ashtangoo: Body: Fabricated out of 300mm dia and 200mm dia M.S departmental pipe (of size 200mm dia, 150mm long and 300mm dia ×300mm length). The body material has to be shifted from sub-divisional premises to private workshop in a private vehicle.( pipe thickness= 6mm). Flap/Weight plate: fabricated out of M.S plate of thickness 12mm along with ethylene propylene diamine monomer (EPDM) washer and M.S bottom counter weight plate (6mm thick) complete with proper fitting arrangement and M.S. back stopper. Hinge: fabricated out of M.S plate of thickness not less than 12mm with required sliding arrangement. Seat: fabricated out of square/round bar not less than 16mm thick with proper finishing and buffing. Strainer: fabricated out of 10mm thick square/round bars and MS plate strips top and bottom of angle (50mm) length of bar 250mm. Top flange: 200mm dia, 12mm thick Bottom plate: 300mm dia, not less than 12mm thick. Top plate: Connecting 200mm dia pipe and 300mm dia pipe, 12mm thick. Coating: The foot valve body should be completely coated with metallic redoxide and enamel paint. Warranty: One year. The foot valve should be complete leak proof. The equipment should be installed and tested at site complete. The job also includes providing and fitting of nut bolts of 3kgs of size along with 4mm thick NBR gasket of 300 mm dia .
Repairing of rising main MS pipe of dia 250mm for arresting leakage by way of dismantling of rising main at various joints. The welding (150cm approx.) at various spots is to be carried out by mobile type welding set which includes DG set, welding set, Gas cutter, electric grinder, superior quality electrodes, tata mobile, skilled and unskilled workers for carrying/execution of welding. After welding and repairing the pipe to be aligned and fitted properly as per requirement and tested successfully. The job includes providing and fitting of nuts bolts of 5kgs, 4 No. gaskets of 250mm dia. The job includes all types of carriages viz., head load for shifting of welding set at various spots.
Meer Engineers (BID ID -2429621)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .