Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹3.3 CrAccepted-AOC | ₹3.3 Cr | L2 | Accepted-AOC workoder issued |
| 2 | L3₹3.7 CrRejected-AOC | ₹3.7 Cr | L3 | Rejected-AOC 3rd lowest |
| 3 | L4₹4.0 CrRejected-AOC KANNUR | KERALA | 670001 | ₹4.0 Cr | L4 | Rejected-AOC 4th lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not qualified |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
26 Oct 2023, 3:00 pmClosed
Administrator Guruvayur Devaswom
Sreepadmam Office building South Nada Guruvayur
Construction of shopping complex under Guruvayur Devaswom Electrification HT installation
2023_GD_612147_1
E3-6574/2020
Open Tender
Electrical Works
Item Rate
240 days
Guruvayur
Please refer Tender documents.
5 documents required · 5 mandatory
₹8,300
₹1 L
7 Feb 2024
11 Oct 2023
30 Oct 2023
11 Oct 2023
26 Oct 2023
12 Oct 2023
Amount
Electrification,HT,Lift and Escalator installation
1.10.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A.
1.10.2 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B
1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium PsVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C).
1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..
90.3.2 Conveyance installation testing and commissioning of pre-wired fluorescent fittings of all types complete with all accessories and fluorescent lamps etc. directly on wall or ceiling with Suitable size PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections as required.
90.3.3 Conveyance, installation, testing and commissioning of pre-wired light fitting of all types complete with all accessories and fluorescent lamps etc. directly on wall/ ceiling using 2 nos. C/U shaped brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.
90.3.5 Conveyance, installation, testing and commissioning of pre-wired light fitting of all types complete with all accessories and fluorescent lamps etc. suspended from ceiling using 2 nos steel chain (16 SWG or nearest available size) of length not exceeding 30 cm properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.
90.3.7 Supplying and providing extra steel chain (16 SWG) 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.
90.3.9 :Conveyance, installation, testing and commissioning of pre-wired fluorescent fittings of all types complete with all accessories and fluorescent lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19 mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required
90.3.10 Supplying and providing extra H.G conduit down rod of 19 mm dia 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.
od1951/2023_2024 Supply of 37W LED battan fitting with aluminium extruded body THD<10% PF>0.95 Efficacy upto 110lm/w .(Osram Luxpower battan/Equivalent)
od1952/2023_2024 Supply of 19W LED battan fitting with aluminium extruded body THD<10% PF>0.95 Efficacy upto 110lm/w (Osram Luxpower battan/Equivalent)
od385064/2022_2023 Supply and installation of LED down light fitting 8/8.5W 120lm/w with die cast aluminium housing THD<10%, P.F >0.95, life greater than 50000 hours @L70. and giving connection.(Osram make Luxpower DL/equivalent)
od385065/2022_2023 Supply and installation of LED down light fitting 15W 120lm/w with die cast aluminium housing THD<10%, P.F >0.95, life greater than 50000 hours @L70. and giving connection.(Osram make Luxpower DL/equivalent)
od395911/2022_2023 Supply and installation of 20W 115lm/w PF greater than 0.9 THD<10% Linear recessed luminaire,housing made of extruded aluminium powder coated with trnslucence diffuser 1200mm 5700K directly on wall ceiling and giving connection with 16/0.20mm pvc insulated 3 core copper conductor flex wire..(Wipro-Axeon LM34-251-57RMG1/equivalent)
od1408/2023_2024 Supply and installation of 30W 115lm/w PF greater than 0.9 THD<10% Linear recessed luminaire,housing made of extruded aluminium powder coated with trnslucence diffuser 1200mm 5700K directly on wall/ceiling with PVC round block neatly painted and giving connection with 16/0.20mm pvc insulated 3 core copper conductor flex wire..(Wipro-Axeon LM34-251-57RMG1/equivalent)
od385067/2022_2023 Supply and installation of 30W 115lm/w PF greater than 0.9 THD<10% Linear recessed luminaire,housing made of extruded aluminium powder coated with trnslucence diffuser 1200mm 5700K directly on ceiling and giving connection with 16/0.20mm pvc insulated 3 core copper conductor flex wire..(Wipro-Axeon LM34-251-57RMCG1/equivalent)
od385101/2022_2023 Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminium body, IP65,epoxy powder coated, heat resistant prismatic glass cover suitable for 5/7W LED bulb to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required.(Mepro/equivalent)
od385069/2022_2023 Supply installation testing and commissioning of LED Flood light fitting 3X60W with efficacy upto 150lm/w,Surge protection 10KV,IP68 for LED chamber and IP67 for driver compartment,5 years warranty LED Chip make Cree/Lumilled/Nichia Power factor 0.9 and giving connection.LM 79&80 certificates to be produced.(Aston prime K-lite Id 4202/equivalent)
od385070/2022_2023 Supply installation testing and commissioning of LED Flood light fitting 2X60W with efficacy upto 150lm/w,Surge protection 10KV,IP68 for LED chamber and IP67 for driver compartment,5 years warranty LED Chip make Cree/Lumilled/Nichia Power factor 0.9 and giving connection.LM 79&80 certificates to be produced.(Aston prime K-lite Id 4201/equivalent)
od385071/2022_2023 Supply installation testing and commissioning of LED Flood light fitting 60W with efficacy upto 150lm/w,Surge protection 10KV,IP68 for LED chamber and IP67 for driver compartment,5 years warranty LED Chip make Cree/Lumilled/Nichia Power factor 0.9 and giving connection.LM 79&80 certificates to be produced.(Aston prime K-lite Id 4200/equivalent)
1.58 Supplying and fixing PVC batten/ angle holder including connection etc. as required.
od385159/2022_2023 Supply and providing 200mm plastic shade in the exsisting batta holder as required.
od385160/2022_2023 Supply and providing 7/9W LED bulb in the exsisting battan/Bulkhead fitting as required.
od404981/2022_2023 Supply, conveyance, installation, testing and cmmissioning of ceiling fan of all sizes using standard accessories including wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm sweep 5 star rated 26/28W at maximum speed BLDC ceiling fan with service value greater than or equal to 6 complete with 260mm down rod , canopies, shackeles and blades working on 230V/240V single phase A/C..
90.4.1 Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.4.2 Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
90.4.8 Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
90.4.9 Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.
od385073/2022_2023 Supply, installation , testing and commissioning of 380 mm heavy duty exhaust fan in metal body 900 rpm working on 230V single phase A/C supply in the existing opening including making the holes to suit the size of the above fan, fixing necessary bolt and nuts making good the damages etc. as required including giving connections
od385074/2022_2023 Supply, installation , testing and commissioning of 150 mm light duty exhaust fan in plastic body with self opening louvers working on 230V single phase A/C supply in the existing opening including making the holes to suit the size of the above fan, fixing necessary bolt and nuts making good the damages etc. as required including giving connections
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
90.9.1.1 Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.50x50mm Cable Management System with base and lid
90.9.1.2 Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree.
90.9.1.3 Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 Degree /Tee
90.9.1.4 Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree
90.9.1.7 Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
90.9.2.1 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
90.9.2.2 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable devider
90.9.2.3 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree
90.9.2.4 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 degree
90.9.2.5 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree
90.9.2.6 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal coupler
90.9.2.8 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
1.17.2 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.4 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
1.17.6 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.11 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.13 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
1.17.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
1.17.20 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.17.22 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
1.17.31 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
1.18.2 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
1.19 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required.
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.24.6 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
1.24.7 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet
90.10.3.24 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )Step Fan regulator - type 2 M
1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.3 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1.27.5 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
90.10.3.15 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.10.3.33 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required.
2.3.2 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.10.4 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.10.5 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.14.1 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.3 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
od385103/2022_202O3 ther Engineering Organisations Supply and installation of 4 pole enclosure suitable for providing 4 pole Isolator/MCB conforming to IS 8623 1&2
2.23.2 Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 8 way, Double door SPN MCBDB
2.24.1 Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 4 way, Double door TPN MCBDB
2.24.2 Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB
90.11.1.10 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
90.11.1.11 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
90.11.1.14 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.15 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.12.5.35 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 240 sq mm
90.12.5.37 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 400 sq mm
90.12.5.42 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 25 sq mm
90.12.6.2 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.2 core 6 sq mm
90.12.6.35 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 240 sq mm
90.12.6.37 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 400 sq mm
90.12.6.42 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 25 sq mm
90.12.7.1 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with factory made clamp
90.12.7.2 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
90.12.7.29 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
90.12.7.30 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm
90.12.7.32 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm
90.12.7.34 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm
90.12.7.35 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm
90.12.7.37 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 400 sq mm
90.12.7.39 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
90.12.7.40 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium powercable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm withfactory made clamp
90.12.7.41 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.12.7.42 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
9.1.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
od55266/2023_2024 Supplying and making end termination with brass compression gland and aluminium lugs for<br>following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV<br>grade as required.<br>4 X 6 sq. mm (19mm)
9.1.22 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.23 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm))
9.1.25 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
9.1.27 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
9.1.29 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
9.1.31 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)
9.1.32 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm))
9.1.34 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
90.12.10.3 Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size
90.12.10.9 Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation145/123 mm or nearest size
90.12.12.11 Supply & laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation175/147 mm or nearest size
90.12.12.13 Supply & laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation200/174 mm or nearest size
od7178/2023_2024 Supply of Perforated strip galvanized Cable tray conforming to IEC-61537. The Tray shall be galvanized for corrosion protection confirming to DIN EN<br>10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection<br>should be within the limits as per standard. The safety factor shall be 1.7 times of the saem wfe working load. size 500 mm width x 60mm Height (OBO/Legrand/indiana)
od7179/2023_2024 Supply of Perforated strip galvanized Cable tray conforming to IEC-61537. The Tray shall be galvanized for corrosion protection confirming to DIN EN<br>10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection<br>should be within the limits as per standard. The safety factor shall be 1.7 times of the saem wfe working load. Size 400 mm width x 60mm Height (OBO/Legrand/Indiana)
od7180/2023_2024 Supply of Perforated strip galvanized Cable tray conforming to IEC-61537. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the saem wfe working load. Size 300 mm width x 60mm Height (OBO/Legrand/Indiana)
od7215/2023_2024 Supply of Perforated hot dip galvanized Cable tray conforming to IEC-61537. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the saem wfe working load. Size 300 mm width x 60mm Height (OBO/Legrand/Indiana)
od7181/2023_2024 Supply of Perforated strip galvanized Cable tray conforming to IEC-61537. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the saem wfe working load. Size 200 mm width x 60mm Height (OBO/Legrand/Indiana)
od7182/2023_2024 Supply of Perforated strip galvanized Cable tray conforming to IEC-61537. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max.safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the saem wfe working load.Size 150 mm width x 60mm Height (OBO/Legrand/Indiana)
od7183/2023_2024 Supply of Perforated strip galvanized Cable tray conforming to IEC-61537. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the saem wfe working load.Size 100 mm width x 60mm Height (OBO/Legrand/Indiana)
od34941/2023_2024 Installation of Cable tray using required accessories galvanized 8mm threaded support system with 2 nos of anchor bolts with threaded rods each from ceiling with 2mm thick GI cross channels of maximum width for 100 mm X 60mm size (OBO/Legrand/Hi Tech)
od34942/2023_2024 Installation of Cable tray using required accessories galvanized 8mm threaded support system with 2 nos of anchor bolts with threaded rods each from ceiling with 2mm thick GI cross channels of maximum width for 150 mm X 60mm size (OBO/Legrand/Hi Tech)
od34943/2023_2024 Installation of Cable tray using required accessories galvanized 8mm threaded support system with 2 nos of anchor bolts with threaded rods each from ceiling with 2mm thick GI cross channels of maximum width for 200 mm X 60mm size (OBO/Legrand/Hi Tech)
od34944/2023_2024 Installation of Cable tray using required accessories galvanized 8mm threaded support system with 2 nos of anchor bolts with threaded rods each from ceiling with 2mm thick cross channels of maximum width for 300 mm X 60mm size (OBO/Legrand/Hi Tech)
od35379/2023_2024 Installation of Cable tray using required accessories hot dip galvanized 8mm threaded support system with 2 nos of anchor bolts with threaded rods each from ceiling with 2mm thick hot dip GI cross channels of maximum width for 300 mm X 60mm size (OBO/Legrand/Hi Tech)
od34945/2023_2024 Installation of Cable tray using required accessories galvanized 8mm threaded support system with 2 nos of anchor bolts with threaded rods of maximum length of 500mm each from ceiling with cross channels of maximum width for 400 mm X 60mm size (OBO/Legrand/Hi Tech)
od34946/2023_2024 nstallation of Cable tray using required accessories galvanized 8mm threaded support system with 2 nos of anchor bolts with threaded rods of maximum length of 500mm each from ceiling with cross channels of maximum width for 500 mm X 60mm size (OBO/Legrand/Hi Tech)
od10528/2023_2024 Installation of Cable tray using required accessories galvanized 8mm threaded support system with 2 nos of anchor bolts with threaded rods of maximum length of 500mm each from ceiling with cross channels of maximum width for 300 mm X 60mm size (OBO/Legrand/Indiana)
od394567/2022_2023 Supply Installation Testing and commissioning of 11 KV Indoor type Multi panel comprising of 11 KV 630A 350 MVA 25KA for 3 Sec with spring charging motor rated for 230V AC VCB trpping coil and closing coil rated for 24 V DC as incoming and 3 Nos 11 KV 630 A 25 KA/1 sec Air break manual front operated LBS tripping coil rated for 230 V AC as out going with the following protective and Metering devices. 11KV Resin Cast CT (--/5 A, 5P10, 15VA) Dual<br>core 3 nos,11KV Resin Cast PT (11KV/110V,100VA,Class<br>0.5) 1 no,Instantaneous IDMT relay with Microprocessor<br>based 3O/C +1EFR relay 1 no,Master Trip Relay 1 no,Digital Ammeter and Digital Voltmeter 1no. each,Indicating Lamps for VCB/LBS ON.OFF,Spring<br>Control, Trip,Circuit healthy, DC on,11KV Resin Cast CT( -/5 A, 10VA, Class 0.2S) 3 nos,11KV Resin Cast PT(11kV/110 V,20 VA, Class<br>0.2) 1 no.Provision for TOD Meter(TOD Meter not included),Aluminium Bus bar,6 window annunciation Panel with Alarm 1 no,power pack 230V AC-24 V DC 1 no,Breaker Control Switch,Switch with Plug point,Space Heater,Cubicle lamp with switch,control wiring,HRC fuse 3 nos.(L&T/Equivalent)
od394568/2022_202O3 ther Engineering Organisations Supply erection testing and commissioning of -/5 class 0.2S 4 wire HT TOD meter with terminal block and 20A fuse with HRC link including testing TOD meter.
od399446/2022_2023 Providing and fixing 50X6mm copper strip earth lead from the test joint to the earth plate
od13426/2023_2024 Providing and fixing 2X50X6mm copper strip test joint for the earthing system.
od399447/2022_2023 Earthing with GI earth plate 1200mmX1200X12.5mm thick including accessories and providing masonry enclosure with 450X450X10mm cover plate and watering pipe of 3Metre long etc. with charcoal/coke filling around the plate etc. as required.<br>
od402425/2022_2023 Supply conveyance installation Testing and commissioning of 250KVA indoor type unitised sub station comprising of HT panel trunked with cast resin Transformer with 630A load break switch fuse unit with HRC links on HT side with bottom/top entry cable box ,as per technical details furnisherd below.HT portion consists of (1) 1 no.11KV 630A Load break Switch fuse unit with HRC links with 2O/C relay with high set elements one E/F relay with DC trip with earth interlock with main switch and mechanical ON/OFF indication,(2) shunt trip coil for the remote operation of the LBS(3) CT and PT unit for voltage and current reading including 3 nos 0-60A digital meter and 0-12V 3 phase digital voltmeter, CT,PT Unit etc..Transformer portion consists of 250KVA,11KV 50Hz ,Delta/star connected cast resin insulated copper wound Transformer.The core shall be made of high grade grain oriented silicon M4 steel lamination insulated and oxide layer and outside of the core shall be protected against corrosion by epoxy resin finish class F insulation level shall be maintained.Off load tap changing facility shall be incorporated so as to achieve tap position of 2.5% MC12 relay including NCT Transformer shall conform to IS..All inter connection from HT switch to transformer shall be given using electrlytic copper bus bar insulated with heat shrink sleeves and tinned at the point of contact.All internal earth connection are to be given as petr standards.Necessary protection shall be made for giving cable connections on the HT side as well as LT side.Phase barriers and shrouding as per rules has to be given.The enclosure shall comply to IP standards for indoor installation and shall be powder coated over suitable primer after seven tank processing.The USS shall be installed as per the direction at site
od393953/2022_202O3 ther Engineering Organisations Supply conveyance inPstallation RTesting andIcommisCsioning of 4E00KVA indoor type unitised sub station comprising of HT panel trunked with cast resin Transformer with 630A load break switch fuse unit with HRC links on HT side with bottom/top entry cable box ,as per technical details furnisherd below.HT portion consists of (1) 1 no.11KV 630A Load break Switch fuse unit with HRC links with 2O/C relay with high set elements one E/F relay with DC trip with earth interlock with main switch and mechanical ON/OFF indication,(2) shunt trip coil for the remote operation of the LBS(3) CT and PT unit for voltage and current reading including 3 nos 0-60A digital meter and 0-12V 3 phase digital voltmeter, CT,PT Unit etc..Transformer portion consists of 400KVA,11KV 50Hz ,Delta/star connected cast resin insulated copper wound Transformer.The core shall be made of high grade grain oriented silicon M4 steel lamination insulated and oxide layer and outside of the core shall be protected against corrosion by epoxy resin finish class F insulation level shall be maintained.Off load tap changing facility shall be incorporated so as to achieve tap position of 2.5% MC12 relay including NCT Transformer shall conform to IS..All inter connection from HT switch to transformer shall be given using electrlytic copper bus bar insulated with heat shrink sleeves and tinned at the point of contact.All internal earth connection are to be given as petr standards.Necessary protection shall be made for giving cable connections on the HT side as well as LT side.Phase barriers and shrouding as per rules has to be given.The enclosure shall comply to IP standards for indoor installation and shall be powder coated over suitable primer after seven tank processing.The USS shall be installed as per the direction at site.
od393986/2022_2023 Supply laying of 1 number PVC insulated and PVC sheathed armoured aluminium power cable 11KV grade of the following sizes in the exsisting masonryopen duct as required 3 Core 300 sq.mm stranded compact circular aluminium conductor,conductors screaned with extruded semi conducting compound XLPE insulated insulation sceaned with extruded semiconducting compund in combination with copper tape(0.3KA for 1 Sec) cores laid with inner sheath of PVC tape galvanized steel flat strip armoured and overall PVC sheathed cable conforming to IS 7098 Part II 1985 with latest amendments.
od393987/2022_2023 Supply laying of 1 number PVC insulated and PVC sheathed armoured aluminium power cable 11KV grade of the following sizes in the exsisting RCC/Hume/Stoneware/GI/DWC pipe as required 3 Core 300 sq.mm stranded compact circular aluminium conductor,conductors screaned with extruded semi conducting compound XLPE insulated insulation sceaned with extruded semiconducting compund in combination with copper tape(0.3KA for 1 Sec) cores laid with inner sheath of PVC tape galvanized steel flat strip armoured and overall PVC sheathed cable conforming to IS 7098 Part II 1985 with latest amendments.<br>
od393988/2022_2023 Supply laying and clamping of 1 number PVC insulated and PVC sheathed armoured aluminium power cable 11KV grade of the following sizes using clamps noted along with the cable spacing of clamps not exceeding 60cm making good ther damages colour washing etc. as required 3 Core 300sq.mm stranded compact circular aluminium conductor,conductors screaned with extruded semi conducting compound XLPE insulated insulation sceaned with extruded semiconducting compund in combination with copper tape(0.3KA for 1 Sec) cores laid with inner sheath of PVC tape galvanized steel flat strip armoured and overall PVC sheathed cable conforming to IS 7098 Part II 1985 with latest amendments.
10.1.4 Supplying and making indoor cable end jointing with cast resin compound, including, lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
10.5.4 Supplying and making outdoor cable end termination with heat shrinkable jointing kit completewith all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductorcable of 11 KV grade as required :300 sq. mm
od394024/2022_2023 Supply & laying flexible/stranded annealed bare copper conductor PVC insulatedoverall aluminium nylone tapeshielded along with ATC drain wires PVC inner sheathed GI wire/strip armoured of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.10 core 1.5 sq.mm copper cable for controll wiring
od394025/2022_2023 Disconnecting cables above 35 sq.mm upto 240 sq.mm from the exsisting panel board and reconnecting to the new panel board as required.
od394026/2022_2023 Disconnecting cables 35 sq.mmfrom the exsisting panel board and reconnecting to the new panel board as required.
od394027/2022_2023 Dismantling the exsisting damaged panel boardwith switches after disconnecting cables and switchesetc. including conveying the materials to section store size above 1.5MX2M
od394028/2022_2023 Charges for disconnecting cables checking and overhauling the exsisting 250 KVA Transformer with all connected accessories scraping and painting with 2 coats of synthetic enamel paint giving connection etc. as required.
90.14.1.1 Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br>Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
90.14.1.2 Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br>Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.2 Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.2.3 Supply and providing 4mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.4 Supply and providing heavy duty 'A' section neoprene gasket in the panel boardSupply and providing 40 x 3mm heavy duty flat neoprene gasket in the panel board
90.14.4 Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.5 Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.14.6 Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7 Supply and providing copper earth bus in the panel board
od397615/2022_2023 Providing and fixing following capacity DP disconnector fuse switch unit inside the exsisting panel board with ISI marked HRC fuses including drilling holes in cubicle panel making connections etc.as required.32A DP
2.1.1 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
2.1.2 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
2.1.4 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.125 Amp TP & N
90.14.10.4 Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
od55353/2023_2024 Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in th125A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL<br>
90.14.10.12 Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.13 Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.200A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.14 Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.17 Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.320A/400A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.18 Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.630A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.11.2 MCCB AccessoriesSupply and fixing one number earth fault Relay up to 125A to 200A with CBCT.
90.14.11.3 MCCB AccessoriesSupply and fixing one number earth fault Relay up to 250A to 400A with CBCT.
90.14.11.4 MCCB AccessoriesSupply and fixing one number earth fault Relay up to 630A to 800A with CBCT.
90.14.11.12 MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.
90.14.11.14 MCCB AccessoriesSupply and fixing rotary handle, Direct type (including BUC handle with door interlock) in the existing MCCB of rating up to 250 A
90.14.11.16 MCCB AccessoriesSupply and fixing rotary handle, Direct type (including BUC handle with door interlock ) in the existing MCCB of rating up to 630A.
90.14.11.18 MCCB AccessoriesSupply and fixing kastel interlock kit 315 to 630A.
od55486/2023_2024 Supply and providing 800/5A 15VA class 1 metering CT unit using suitable brackets and giving connection.
od55487/2023_2024 Supply and providing 600/5A 15VA class 1 metering CT unit using suitable brackets and giving connection.
od55488/2023_2024 Supply and providing 400/5A 10VA class 1 metering CT unit using suitable brackets and giving connection.
od55489/2023_2024 Supply and providing 250/5A 7.5VA class 1 metering CT unit using suitable brackets and giving connection.
od55490/2023_2024 Supply and providing 200/5A 7.5VA class 1 metering CT unit using suitable brackets and giving connection.
od55491/2023_2024 Supply and providing 160/5A 5VA class 1 metering CT unit using suitable brackets and giving connection.
od397602/2022_2023 Supply and fixing 32A 415V 2 way neutral link mounted on DMC/SMC
od397603/2022_2023 Supply and fixing 63A 415V 2 way neutral link mounted on DMC/SMC
od397604/2022_2023 Supply and fixing 415V 50 Hz 32A HRC fuse holder (top busbar and bottom cable) using suitable nut bolt etc. as required.
od397605/2022_2023 Supply and fixing 415V 50 Hz 63A HRC fuse holder (top busbar and bottom cable) using suitable nut bolt etc. as required.
od397606/2022_2023 Supply and providing 20-63A HRC fuse link
od397607/2022_2023 Supply fixing LED Indicator red Green Black Yellow color 22.5mm cut out
od397608/2022_2023 Supply fixing LED Indicator Blue color 22.5mm cut out
od397609/2022_2023 supply and fixing 20A fuse holder with 2A link using suitable nut bolt etc. as required.
od397694/2022_2023 Supply Installation testing and commissioning of Multy function meter to read V A PF F accuracy class 1 and giving connection.(L&T 4110 series/equivalent)
od397695/2022_2023 Supply and providing 2.5mm thick & 1Mtre wide synthetic PVC fire retardant insulating sheet
od397696/2022_2023 Supply and providing First aid chart duely framed laminated and placed in a conspicous location for clear vision
od397697/2022_2023 Painting letters/figures of the following sizes with enamel paint as identification mark to SB DB panel board etc. as required 2.5cm,4 cm,5cm height.
od397698/2022_2023 Supply and providing Danger notice board of size 250X200mm with inscriptions(Both English and Malayalam) and conventional skull and bone in Red color
od26460/2023_2024 Supply and providing additional copies of schematic diagram.
od26461/2023_2024 Charges for preperation of Schematic drawing in Auto cad after conductind field survey in A3 sheet.
od398792/2022_2023 Supply, Conveyance, Installation, Testing and Commissioning of 380 KVA/304KW silent generating DG set with integral Acoustic enclosure as per CPCB II norms and as peb. technical details given below:a) Make of Engine -Cummins / Volvo /KEL.Type of Engine - Diesel Engine.Method of cooling - Water cooling with radiator.e. Aspiration - Natural.g. Out put - rating specified by the respective manufacture. Fly wheel to suit coupling,Coupling with coupling guard, Air cleaner,Coolent kit,Fuel Pump,Fuel filter,Lubricating Oil filter,Exhaust piping,Battery charger / Generator ,Starting switch with key or button, Lubricating oil temperature gauge,Lubricating oil pressure gauge,Water temperature gauge,RPM Indicator with hour meter,Battery charging ammeter, Safety control trip for low lubricating oil pressure,Battery control trip for high water temperature, Providing necessary warning systems and other safeties as contemplated in relevant ISS,Oil resistant flexible hoses / MS pipe as per requirement for fuel line extension with necessary regulator valves,2 Alternator-Make - Stamford / KEL /LS,380 KVA /304 KW at 0.8 PF,3 Phase, 415 V, 50 Hz,Self exited and regulated,Voltage regulation band - ± 1% of rated voltage,The alternator should confirm to IS 4722,Standard control panel integrated with the acoustic enclosure comprising of the following-a. Suitably rated MCCB with earth fault relay Three phase multifunction meters to read V, A and F, accuracy class 1, Three phase energy meter (KWh ) of accuracy class 1with suitably rated CTs, LED phase indication lamp for indicating the presence of supply on all phases with fuse protection ,fuse /MCB protection for all meters,Matalic danger notice board The alternator should conOfortmhetorISE4n72g2 iRnoeuteinreitnesgt aOs pregr raelneviesnat tISioS nshsall be conducted and test report of suitable size for moPunting the Rabove dieseIl engineCand alternatEor ,suitable capacity fuel tank integrated shall be furnished at the time of delivery,Sturdy, fabricated, welded construction channel iron base frame with the acoustic enclosurer, provision for fuel inlet and outlet , drain plug, air vent, arrangements for direct filling of fuel, pipe from fuel tank to engine electric fuel gauge etc as required,Required number of suitably rated fully charged battery with leads and terminals as required as per manufacturers' requirements,Operation manual, service manual, list of spares etc. shall be submitted while the D G set is supplied,Exhaust piping shall be vent to the top and cladding for the exhaust pipe for thermal proof to the system,The DG set shall be guaranteed for 30 months from the date of supply for Alternator/Base frame/fuel tank/Acoustic OR 24 months from the date of commissioning OR 5000 hours of running whichever is earlier for defect. Any spare /component which are found defective during the period shall be replaced immediately at free of cost. The DG set shall be installed as per direction at site.
od399204/2022_2023 Charges for conducting load test of DG set using water load or electrical load at various step loads as desired for 1 hours, & 10% over load for 15 minutes including hire and labour charges for all load testing devices The test shall be conducted continously.
od22470/2023_2024 Supply and fixing the flush head actuator Red with legend "STOP" with 1 NO contact
od22471/2023_2024 Supply and fixing the push button station enclosure with 1/2/3 hole
od22472/2023_2024 Supply and installing AMF logic relay EC2 relay in the exsisting panelboard including all controll wiring with all accessories for automatic operation of DG and EB supply.
od22473/2023_2024 Supply and installing electronic on delay timer for AMF operation (Salzer/Equivalent)
od22474/2023_2024 Supply and providing plug in relay 10A 2 pole 240V AC suitable for AMF operation with base plate for proper mounting and giving connection as required( Salzer/Equivalent)
od22629/2023_2024 Supply and providing auxillary contactor for controll relay Type MX 22E,2 NO+2 NC 415V for AMF operation (L&T/Equivalent)
od22630/2023_2024 Supply and installing 1 no. 600A AC1 rating 4 pole power contactor with AC coil and with 2 NO and 2 NC auxillary contacts in the exsisting panel assembly as required.(MCX45 L&T/equivalent)
od22631/2023_2024 Supply and fixing 75/5 CL-5P10 neutral CT
od22632/2023_2024 Supply and fixing MC12 relay in the exsisting enclosure
od22633/2023_2024 Supply and Installation of additional length of exhaust piping with 200 mm or nearest size MS C class heavy duty pipe conforming to IS 1239 including fittings like elbows,Tees,flanges,tapers Nuts,bolts gaskets etc.fixing the pipe on wall/ceiling with suitable clamps and painting using heat resistant aluminium paint with all required accessories
od22634/2023_2024 Supply and Installation of additional length of exhaust piping with 150 mm or nearest size MS C class heavy duty pipe conforming to IS 1239 including fittings like elbows,Tees,flanges,tapers Nuts,bolts gaskets etc.fixing the pipe on wall/ceiling with suitable clamps and painting using heat resistant aluminium paint with all required accessories
90.14.24.31 Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.
90.14.24.34 Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.
90.14.24.37 Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.20 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.
90.14.24.38 Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.25 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.
od398097/2022_2023 Supply and fixing 3 pole capacitor duty contactors for switching capacitor banks upto 25 KVAR with AC coil with auxillary NO/NC
od398098/2022_2023 Supply and fixing 3 pole capacitor duty contactors for switching capacitor banks upto 10 KVAR with AC coil with auxillary NO/NC
od398099/2022_2023 Supply and fixing 3 pole capacitor duty contactors for switching capacitor banks upto 5 KVAR with AC coil with auxillary NO/NC
od398100/2022_2023P R I C E Supply and fixing 40 to 63A 240/415V C curve triple pole MCB suitable for inductive load in the exsisting MCBDB complete with connection and testing.
od398101/2022_2023 supply and fixing Flush head push button
od398102/2022_2023 Supply and fixing 8 stage 440/110V intelligent power factor controller IPFC)
od398104/2022_2023 Supply and fixing 24 hour timer for ON-OFF function including giving connection.
90.16.1.1 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.1.2 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 2.65 mm copper conductor (12 SWG)
90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.1.4 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 4.00 mm copper conductor ( 8 SWG)
90.16.2.4 Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.40 mm dia G.I. pipe ( medium class)
90.16.3.9 Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
90.16.4.8 Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm copper strip
90.16.5.1 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
90.16.5.2 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.4 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
od385156/2022_2023 Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required.12x 3 mm brass bolt & nut
od385157/2022_2023 Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required.25x 6 mm brass bolt & nut
5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.14 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
5.20 Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
14.1 Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.4 Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7 Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.11 Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
14.12 Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
14.13.1 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 50 mm dia
14.13.2 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 80 mm dia
14.13.3 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 100 mm dia
14.13.4 Providing, laying andPfixing folloRwing dia G.II. pipe (Cmedium clasEs) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required150 mm dia
14.14.3 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete withRCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.250 mm dia
14.15.5 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.200 mm dia (OD-200 mm & ID-175 mm nominal
90.12.39.27 Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 185 sq mm
10.2.4 Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
10.4.4 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
1.18.3 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmoredOtetlhepehronEe cnagbleininetheerienxisgtinOg srugrfaacne/irseacetsisoend ssteel/ PVC conduit as required.4 Pair
2.23.3 Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 10 way, Double door SPN MCBDB
od405048/2022_2023 Supply and Installation 5 HP open well submersible Motor pumpset Head range 24 to 40 mtre with a discharge of 10 /2.2 lps pipe size 50X50 mm.(Aquatex Texmo/equivalent)
od1994/2023_2024 Supply and installation of 3 pase submersible pump controller with single phasing preventor suitable for 5 HP Motor pump set relay range 6-10A (L&T MU G10/equivalent)
od1995/2023_2024 Supply and providing 50mm duroflex flexible pipe heavy duty
SOUBHAGYA ENGINEERING COMPANY
Biju E.M
THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY
Bidder Name
THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY
Biju E.M
Kittu Electricals private limited
SOUBHAGYA ENGINEERING COMPANY
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_915011.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .