Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-I₹19.9 LAccepted-AOC C O NIDHI MEDICAL STORE LAKKAR BAZAR SHIMLA 01 | SHIMLA | HIMACHAL PRADESH | 171001 | ₹19.9 L | L-I | Accepted-AOC Lower side quoted rates |
| 2 | L-II₹20.1 LRejected-Finance DEGREE COLLAGE 001 NEAR HAMIRPUR ANU HAMIRPUR H P | ₹20.1 L | L-II | Rejected-Finance Higher side quoted rates |
| 3 | L-III₹26.0 LRejected-Finance CHIEF ENGINEER OP KANGRA ZONE HPSEBL DHARAMSHALA | KANGRA | HIMACHAL PRADESH | 175013 | ₹26.0 L | L-III | Rejected-Finance Higher side quoted rates |
Tender Value
₹24.8 L
EMD Value
₹24,756
Closing Date
28 Jan 2026, 1:00 pmClosed
SE(op.) Circle Mandi HPSEBl, Mandi
O/o SE(op.) Circle Mandi HPSEBl, Mandi
Ten. for pro. Erec. testing and comm. of 2x250 KVA, 11/0.4 KV DTR a/w H T LT lines for resto. and Re-orga. damaged elect. infrastructure of Behri feeder damaged due to heavy rainfall land sinking at Chakyana on 28.08.2025 in ED D/pur ESD Dharampur.
2026_HPSEB_125751_2
HPSEBL/OCM/DB-23/ NIT.-23/2025-26
Open Tender
Electrical Works
90 days
O/o SE(op.) Circle Mandi HPSEBL Mandi
Please refer tender documents
2 documents required · 2 mandatory
₹1,180
₹24,756
12 Feb 2026
22 Jan 2026
29 Jan 2026
22 Jan 2026
28 Jan 2026
22 Jan 2026
(Supply Part) - 250 KVA DTR No.-1
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs (2000mm) with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA's
X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
X-Arm [Channel Iron (100x50x6 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer]
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (35X35x6 mm), Length : (460 ) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
D.O Fuse Unit
Surge Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete (i/c Stay Clamps)
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Pipe Earthing Set and
6 SWG GI wire For Earthing
Panel (Distribution Box LT for 250 kVA DTR MS Sheet of 1.6 mm ( 1100x800x275 mm ) cubide Box complete with stand etc and Al Busbar 40x6 mm( min. 100 Amp ) , AI 50X50X6 mm of length 2.2 Mtr inside .painted /powder coated after primar coating With CoppPer thimbles of 200 Amp, Insulating sleeves etc. MCCB 400 amp 3P 50kA -1 No. ICS 100 % ICU & MCCB 250 Amp 36 kA =3 nos
Half Clamp (M.S. Flat 50X6 mm)
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble off size
Copper Thimble 200 Amp
Danger Plate
Barbed Wire
LT Cable 3.5 X 400 mm²
LT Cable 3.5 X 500 mm²
HT Energy Meters 3-ɸ, 3/4 wire CT-PT operated Static Tri-Vector meter. (PT ratio-/ 110 V, CT ratio-/5 A)
Prov.CT/PT combined unit VT 11kV/110V, CT 10/5A, 15/5A, 20/5A, 25/5A, 50/5A, 100/5A, 150/5A, 200/5A, 400/5A,
Aluminium Paint.
Red Oxide
MSAI (2800X50X50X6mm) 2Nos
MSAI (460X35X35X6mm) 2Nos
MSCI X-arm (2800X100X50X6mm) for CTPT bed (2Nos.)
Transportation & Manual Carriage Charges
Supply Part of 250 KVA DTR No.-2
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs (2000mm) with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA's
X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
X-Arm [Channel Iron (100x50x6 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer]
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (35X35x6 mm), Length : (460 ) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
D.O Fuse Unit
Surge Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete (i/c Stay Clamps)
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Pipe Earthing Set and
6 SWG GI wire For Earthing
Panel (Distribution Box LT for 250 kVA DTR MS Sheet of 1.6 mm ( 1100x800x275 mm ) cubide Box complete with stand etc and Al Busbar 40x6 mm( min. 100 Amp ) , AI 50X50X6 mm of length 2.2 Mtr inside .painted /powder coated after primar coating With CoppPer thimbles of 200 Amp, Insulating sleeves etc. MCCB 400 amp 3P 50kA -1 No. ICS 100 % ICU & MCCB 250 Amp 36 kA =3 nos
Half Clamp (M.S. Flat 50X6 mm)
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble off size
Copper Thimble 200 Amp
Danger Plate
Barbed Wire
LT Cable 3.5 X 400 mm²
LT Cable 3.5 X 500 mm²
HT Energy Meters 3-ɸ, 3/4 wire CT-PT operated Static Tri-Vector meter. (PT ratio-/ 110 V, CT ratio-/5 A)
Prov.CT/PT combined unit VT 11kV/110V, CT 10/5A, 15/5A, 20/5A, 25/5A, 50/5A, 100/5A, 150/5A, 200/5A, 400/5A,
Aluminium Paint.
Red Oxide
MSAI (2800X50X50X6mm) 2Nos
MSAI (460X35X35X6mm) 2Nos
MSCI X-arm (2800X100X50X6mm) for CTPT bed (2Nos.)
Transportation & Manual Carriage Charges
(Supply Part ) H T line
ACSR 6/1/4.72 mm (100 mm²) { Neutral conductor including 1% (Sag, Jumpering and wastage}
Steel Tubular Poles (10 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro' and 3 No. Double Pole Dead End Structures)
Muffs (2000mm) with concerete filling
MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
X-Arm (Horizontal) - MS Channel Iron C type: 75X40x5, Length: 2800 mm x 1 No.]
X-Arm (Horizontal) - MS Channel Iron C type: 100X50x6, Length: 3000 mm x 2 No.]
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps, Straight stapples & Bend Stapples etc.) x (3 No. conductors) x (2 No. sides)
11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure
Stay set complete in all respect (i/c Stay Clamp) (1No. / Single Pole , 4 No. / Double Pole Structures)
Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
HT Earthing set complete
Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 3% (Sag, Earthing, Cross lacing above road and wastage)} @ 0.102 kg/m
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos (For G.O Switch and D.O Switch
GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
D.O Fuse Unit
Pipe Earthing Set and
Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro' structure: 2 No ]
Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro' structure: 2 No]
Danger Plate (250X200X1.6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Paint
Barbed Wire
Transportation Charges
(Supply Part ) L T Line to Stage-2nd
ACSR 6/1/4.72 mm (100 mm²) { Neutral conductor including 1% (Sag, Jumpering and wastage}
Steel Tubular Poles (9 m, Working Load>200kgf/m²) (with Ruling Span 67 m)
Muffs with concerete filling
Shackle Insulator (16 kN)
D-Iron (U- Clamps)
LT Stay Set
Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Paint
Spiral PVC Spacer
Transportation e charges
(Erection Part ) 2Nos.250 KVA DTR
Erection of 250 Kva,11/0.4KV Transformer, LT Box, MCCB Switch, Cable , service Cableand Energy Meter completed in all respect.
(Erection Part ) H T Line to Stage-1st
Erection of S/T pole 10 mtr long,(Double pole structure) with RCC muff Including Concreating digging of pit of size 1.10x0.75x1.50, drilling of holes in poles, X-bracing set, X-arms, Fixing of insulators, X-arms, X- bracing set, fixing of barbed wire, Danger plate, filling of pit & ramming and painting of pole complete in all respects(C.C. 1:3:6 for muffing will be provided by the contractor).
Erection of S/T pole 11 mtr long,(Six pole structure) with RCC muff Including Concreating digging of pit of size 1.10x0.75x1.50, drilling of holes in poles, X-bracing set, X-arms, Fixing of insulators, X-arms, X- bracing set, fixing of barbed wire, Danger plate, filling of pit & ramming and painting of pole complete in all respects(C.C. 1:3:6 for muffing will be provided by the contractor).
Erection of HT earthing set comprising digging of pit, fixing of GI wire to the earth system,and filling of pit complete in all respects.
Erection of stay set HT line, comprising digging of pit, fixing of stay rod, filling of pit, Nozzeling and tightining complete in all respects.
Sagging of conductor 1 KM single GI wire, AAAC cond., comprising laying of Conductor, stringing & sagging, binding with insulator complete in all respects.
Erection of H T line with AAAC/ACSR Conductor 6/1/4.72 mm2 (100mm2) such as stringing, tensioning and sagging,jointing and fastening .
(Erection Part ) L T line
Erection of steel tubular pole 9 mtr long,(single pole structure),with RCC muff Including digging of pit of size 1.10x0.75x1.50, drilling of holes in poles & X-arms, Fixing of shackle insulators, X-arms, filling of pit & ramming and painting of pole complete in all respects.(C.C.1:3:6 for muffing will be provided by the contractor).
Erection of LT stay set line, comprising digging of pit, fixing of stay rod, filling of pit, Nozzeling and tightining complete in all respects.
Sagging of conductor 1 KM single GI wire, AAA C comprising laying of Conductor, stringing & sagging, binding with insulator complete in all respects.
Erection of L T line with ACSR cond 6/1/4.72 (100 mm2) such as stringing, tensioning, sagging, jointing and fastening .
(Civil Part 2 No) Construction of of 2x250 kVA DTR Bed & Fencing
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:3:6 (1 Cement : 3 coarse sand): 6 graded stone aggregate 40 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1.5:3 (1 Cement: 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm
Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete :100x58x1.9mm
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :250x16 mm
Supplying, filling, spreading & leveling gravels of approved size range up to 20cm, in recharge Pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.81 MB
SBD-pdf.rar
Tender Documents • 4.11 MB
GuidelineforERA.pdf
Tender Documents • 2.33 MB
BOQ_186536.xls
BOQ • 0.40 MB
TendernoticeNIT-23.pdf
Additional Documents • 0.70 MB
Download all tender documents and submit your bid