Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-AOC | L1 | Accepted-AOC First lowest | |
| 2 | L2₹39.1 L+₹1.1 L (2.79%)Rejected-AOC | L2 | Rejected-AOC Second lowest | |
| 3 | L3₹39.2 L+₹1.2 L (3.20%)Rejected-AOC | L3 | Rejected-AOC Third lowest | |
| 4 | L4₹40.6 L+₹2.6 L (6.86%)Rejected-AOC | L4 | Rejected-AOC Forth lowest | |
| 5 | L5₹45.5 L+₹7.6 L (19.9%)Rejected-AOC | L5 | Rejected-AOC Fifth lowest |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
24 Dec 2022, 3:00 pmClosed
Executive Engineer
W S Division kochi 18
Deposit Work Eloor municipality Urban agglomeration Replacement of pipe lines and line extension for WSS to Eloor municipality Replacing old damaged 100mm AC and 80mm AC pipe with 110mm PVC and 90mm PVC at various wards and extension of pipeline 63
2022_KWA_540246_1
KWA/ WSD/CHN/42/2022-23
Open Tender
Civil Works - Others
Item Rate
120 days
Eloor
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
24 Feb 2023
16 Dec 2022
26 Dec 2022
16 Dec 2022
24 Dec 2022
16 Dec 2022
Amount
Working charges
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
16.83:Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
100.9.9:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 110 mm nominal outside diameter pipes.
100.9.11:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 160 mm nominal outside diameter pipes.
OD113287/2022-2023:Conveying and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc., and excluding cost of pipes and fittings for External work: 80mm diameter nominal bore.
OD113281/2022-2023:Conveying and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc., and excluding cost of pipes and fittings for External work: 150mm diameter nominal bore.
OD106083/2022-2023:Supply of 80 mm GI bend (M)
OD113280/2022-2023:Supply of 150 mm GI bend (M)
OD113404/2022-2023:Supply of MTA/FTA suitable for 150mm GI/160mm PVC pipe
OD113405/2022-2023:Supply of MTA/FTA suitable for 80 mm GI/90mm PVC pipe
OD106079/2022-2023:Providing and fixing pvc moulded fittings /accessaries for Rigid pvc pipes including jointing with pvc solvent cement 90mm pvc bend
50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
OD113891/2022-2023:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 160mm dia Endcap
50.18.9.22.10:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap
OD111669/2022-2023:Providing and fixing pvc moulded fittings /accessaries for Rigid pvc pipes including jointing with pvc solvent cement 90mm pvc end cap
OD106080/2022-2023:Interconnection with existing 90 mm PVC with newly laid 90 mm PVC using 90 mm Tee/ Coupling/ Bend etc. including earth work, materials cost, labor charges, etc.. complete as per the direction of Engineer in Charge
OD106082/2022-2023:Interconnecting existing 100 mm AC with 90/110/160mm PVC using 100x25 GI saddle, 25 mm FTA, 32 mm PVC pipe, 32 mm valve, 32 mm bend, 32x63 mm reducer, 63 x110 mm reducer including Earthwork excavation, cost, and conveyance of all materials, labor charge, etc complete as per the direction of Engineer in Charge.
OD111651/2022-2023:Interconnection with existing 110 mm PVC/ 100mm AC with newly laid 160 mm PVC using 110 mm PVC Tee,110*160 mm PVC reducer,110 mm CIR/ 100mm CID joint including earthwork, material, labour charge, etc .complete as per the direction of Engineer In charge.
OD113279/2022-2023:Interconnecting the existing 63/75 mm PVC to the newly laid 90/110/160mm PVC by reducer Tee or suitable Saddles with all specials including earthwork excavation, cost of materials, labour ,etc complete as per the direction of Engineer In charge ,
100.31.1.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class I.
100.32.3:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 50mm Double Acting Air Valve.
16.84:Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.)
OD107061/2022-2023:Shifting/Changing water connection from the existing distribution line to newly laid mains upto 110mm dia PVC to an average length of 3m, using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, GI / MS / SS Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m, hire for tools, cost of consumables and labour charges, cost of materials, including charges for lighting, watching, providing caution boards, traffic control etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads and as per the directions of the department officers.
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Material cost
100.98.213:Supply of PVC Pipe, 6kg/cm2, 90mm Dia.
100.98.214:Supply of PVC Pipe, 6kg/cm2, 110mm Dia.
100.98.216:Supply of PVC Pipe, 6kg/cm2, 160mm Dia.
100.98.446:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Double Orifice Type DS2, Size 50mm.
100.98.460:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 150mm.
OD113326/2022-2023:Supply of GI Pipe Medium 80 mm
OD113327/2022-2023:Supply of GI Pipe Medium 150mm
MUKUNDA KUMAR
K M MADHU
udayakumar
DINIL PD
Bidder Name
K M MADHU
DINIL PD
udayakumar
MUKUNDA KUMAR
K K BAKKER
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_786932.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .