Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-Finance 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L1 | Accepted-Finance Documents ok | |
| 2 | L2₹4.5 L+₹4,327.55 (0.97%)Accepted-Finance PLOT NO 2 INDUSTRY AREA NEAR LAL WARE HOUSE OPP OLD HOUSING BOARD COLONY SIRSA SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | L2 | Accepted-Finance Documents ok | |
| 3 | L3₹4.9 L+₹45,168.56 (10.2%)Accepted-Finance | L3 | Accepted-Finance Documents ok | |
| 4 | L4₹5.5 L+₹1.0 L (23.3%)Accepted-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L4 | Accepted-Finance Documents ok | |
| 5 | L5₹6.2 L+₹1.7 L (39.0%)Accepted-Finance | L5 | Accepted-Finance Documents ok |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
10 Jul 2021, 6:00 pmClosed
GE (AF) Chandigarh
GE (AF) Chandigarh PIN-160003
REPAIR TO ELECTRIC WIRING AND FITTINGS, INCLUDING GEYSER ETC AT AFS BARWALA UNDER GE AF CHANDIGARH
2021_MES_451013_1
GE (AF)/CHD/T-13/2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Barwala
All as per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Chandigarh
₹16,000
Yes
20 Jul 2021
12 Jun 2021
12 Jul 2021
12 Jun 2021
10 Jul 2021
26 Jun 2021
12 Jun 2021 - 19 Jun 2021
Amount
Taking down carefully with battens/ PVC surface/ concealed conduit unserviceable copper/ aluminium point wiring (light, fan, socket) complete including fittings such as switches, ceiling roses, pendants, socket etc. and removing unserviceable material from site and making good disturbed surfaces of walls, floors etc. complete all as specified and directed.
M&L for Point wiring PVC insulated unsheathed multistranded copper conductor FRLS cable using two single core 1.5 Sq.mm (nominal area) in and including 19mm dia nonmetallic rigid PVC concealled conduit medium grade including fittings and accessories, one run of continuous single core copper cable of 1.5 Sq. mm connecting to common earth dolly, using the existing pressed steel terminal box, provision of 3 mm thick plastic laminated sheet cover for mounting of switches sockets fan regulators etc. & making good to disturbed surface area for the one light/ fan point controlled by one single pole, one way switch complete all as specified. NOTE: (a).The quoted rates includes the cutting chasis for conduit and sunken boxes.
All as per item No. 2 here-in-before but point wiring for one 5Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
All as per item No. 2 here-in-before but point wiring for one 5Amps socket outlet point on the same board controlled by one single pole, one way switch complete all as specified.
All as per item No. 2 here-in-before but point wiring for one bell point controlled by one single pole, one way bell push complete all as specified.
All as per item No. 2 here-in-before but point wiring using 2.5 sqmm as main wire & 1.5Sqmm as continous earth wire, for one 15Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
All as per item No. 2 here-in-before but point wiring using 4sqmm as main wire & 2.5Sqmm as continous earth wire, for one 15Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
M&L for Point wiring PVC insulated unsheathed multistranded copper conductor FRLS cable using two single core 1.5 Sq.mm (nominal area) in the existing conduit medium grade including fittings and accessories, one run of continuous single core copper cable of 1.5 Sq. mm connecting to common earth dolly, using the existing pressed steel terminal box, provision of 3 mm thick plastic laminated sheet cover for mounting of switches sockets fan regulators etc. & making good to disturbed surface area for the one light/ fan point controlled by one single pole, one way switch complete all as specified.
All as per item No. 8 here-in-before but point wiring for one 5Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
All as per item No. 8 here-in-before but point wiring for one 5Amps socket outlet point on the same board controlled by one single pole, one way switch complete all as specified.
All as per item No. 8 here-in-before but point wiring for one bell point controlled by one single pole, one way bell push complete all as specified.
All as per item No. 8 here-in-before but point wiring using 2.5 sqmm as main wire & 1.5Sqmm as continous earth wire, for one 15Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
All as per item No. 8 here-in-before but point wiring using 4sqmm as main wire & 2.5Sqmm as continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
S&F Switch piano, flush type, single pole, one way, 5 Amp, 230volts complete all as specified.
S&F Switch Bell push, flush type, single pole, one way,, 230volts complete all as specified.
S&F Switch piano, flush type, single pole, one way, 15 Amp 230volts complete all as specified.
S&F Socket outlet multipurpose 3 pin, 5 Amp and 2 pin 5 Amp, flush type, complete all as specified.
S&F Socket outlet multipurpose 3 pin 5 Amp & 15 Amp, flush type, complete all as specified.
S&F Ceiling rose, three terminals, PVC/ isolated body, complete all as specified.
S&F Call bell, electric Ding - Dong type (Domestic pattern), 230 volt, single pole, complete all as specified.
S&F Fan regulator electronic, socket type, suitable for 1200mm /1400mm sweep ceiling fan, fixed in repairs, with and including provision of PVC flexible cable of size 1sqmm copper conductor as required, complete all as specified.
Taking out/down fluorescent tube light fittings of any type / capacity complete and deposited to the E/M store yard/kept at site in safe custody for credit complete all as specified and as directed.
Supply and fixing, LED Decorative box type batten fitting 1x20W including LED Tube Rod retrofit type 20 watt, prewired upto connection block and connecting with three core PVC copper flexible cable of size 1. Sq. mm from ceiling roseto connector block, complete all as specified and directed by Engineer-in-Charge. Make: Havells cat Part LHFXCENNTN1W020 - Fixture and LHLDDCXCML8Q020 LED ROD or its equivalent in Crompton/Wipro
Supply and fixing decorative ultra slim round profile LED lighting fixture with extruded plycarbonate, environmental friendly, energy eficient ready to use pack. complete all as specified and directed by Engineer in Charge. Make-Havells Cat Part No. LHEXBLP7INIW009 or its equivalent in Crompton/Wipro
Supply and fixing wall mounted fittings with ABS housing and clear polycarbonate cover including LED bulb 10watts complete and provision of flexible copper 3core cable 0.5Sqmm from connector/ ceiling rose to fitting all as specified and directed Make : Havells Cat Part No. LHFOFUE1TZ1W012 or its equivalent in Crompton/Wipro
Supply and fiixing Ultra modern designed architectural LED luminaire 36W which provides soft-light and glare free symmetrical illumination suitable for Armstrong/Grid ceiling. MAKE Bajaj Cat Part No. BZRSQL36WGZICW or equivalent in havels/crompton/wipro.
S&F LED 8 watts bollard garden light fitting with robust design and efficient light distribution including light fitting fixing and making PCC block foundation and connecting the fittinngs on PCC foundation block complete all as specified and directed. Make- Havells Cat Part No CONEBL8WLED857SSYMTOPCM (1.0) or equivalent in WIPRO/ PHILLIPS/Crompton.
M&L for PCC 1:3:6 type C.1 using 20mm graded aggregate as in cooping/PCC block for fixing of bollard light fitting complete all as specified and directed
S&F Sheet metal enclosure single pole and neutral with a two pin socket and earth plug complete with one MCB single pole and 240V, 20 Amp ‘B’ curve, 10 kA, including taking out old unserviceable complete all as specified.
S&F Sheet metal enclosure (DB) single phase with neutral,2 way, 240 volt without bus bar & IP 54 protection, including taking out old unserviceable complete all as specified and directed by Engineer-in-Charge.
S&F Sheet metal enclosure (DB) single phase & neutral, double door 4 way, 240 volt with 200 Amps rated bus bar & IP 54 protection, including taking out old unserviceable complete all as specified and directed by Engineer-in-Charge.
All as per item No. 31 here-in-before but DB 8waycomplete all as specified.
All as per item No. 31 here-in-before but DB 12waycomplete all as specified.
S & F MCCB, 63 Amp, 415 Volt,4 pole, breaking capacity 16 KA, 'C' curve, fixed in repairs, complete all as specified.
S & F MCCB, 100 Amp, 415 Volt,4 pole, breaking capacity 16 KA, 'C' curve, fixed in repairs, complete all as specified.
S & F MCB 63 Amp, 415 Volt, TPN, breaking capacity 10 KA, 'C' curve, fixed in repairs, complete all as specified.
S & F MCB 32/40 Amp, 415 Volt, DP, breaking capacity 10 KA, 'C' curve, fixed in repairs, complete all as specified.
S & F MCB 40 Amp, 415 Volt, TP, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified.
S & F MCB 32/ 40 Amp, 415 Volt, SPN, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified.
S & F MCB 6 to 32 Amp, 240 Volt, SP, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified.
M&L for Sub main wiring with two single core 10.0 Sq.mm (nominal area) PVC insulated and unsheathed cables with stranded copper FR conductor in existing conduit including one run of continuous PVC insulated FR copper stranded cable of wiring size 6.0 Sq.mm for earth continuity including taking down old unserviceable cable, complete all as specified. Notes :- (i) 2 runs of 10 Sq.mm main cable + 1 run of 6.0 Sq.mm earth cable considered as 1 Running Metre.
All as per item No. 41 here-in-before but using 2 single 6Sqmm as main & 1 single core 4Sqmm as earth wire complete all as specified.
All as per item No. 41 here-in-before but using 2 single 4Sqmm as main & 1 single core 2.5Sqmm as earth wire complete all as specified.
S&F PVC non metallic rigid concealled conduit 25mm, medium grade inclusive of junction, bends, elbows, tees, reducers, bell mouth tube ends fixing accessories such as couplers lock nuts, saddles, pipe hooks etc. including cutting chases for conduits and taking down existing batten/ conduit and making good to wall as per existing specifications complete all as specified.
Material and labour for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 3mm thick, buried directly in ground, vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI wire 4mm dia by means of bolts, nuts, check-nuts and washers of galvanized iron and of earth wire protected by galvanized iron pipe light grade 15mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No. 5 of SSR-2009 (Part-I).
Taking up / down water heater (Geyser) of capacity 50/35/25 ltrs operating on 230 volts AC electric supply, in any position and of any make, after disconnecting all electric connection and hot and cold water connection, and including transportation to the contractor 's workshop for repair and vice - versa, , and painting / numbering ( if necessary) and vice - versa after repairing, general cleaning/overhauling, cleaning and discaling the tank and assembly with suitable detergent and making fully serviceable and fixing back in same location / position or new location all as directed. Note :- (a) Repairing of any parts except the work mentioned in item No 46 will be maasured and paid seperatelly. (b) Replacement of any un serviceable parts required for making the geyser serviceable will be measured and paid seperatelly under "supply only" No extra payment will be allowed for replacing these items, as the same is deemed to be included in relevant item
Supply only Stainless steel inner tank suitable for 25 ltrs Geyser of any make / shape /holes for fixing geyser assembly.
All as per item No 47 herein before but for 35 ltrs.
All as per item No 47 herein before but for 50 ltrs.
Supply only bottom base assembly of copper 9/8/7/6 holes type suitable for 35/25 ltrs capacity geyser all as directed.
All as per item No 50 here-in- before but for 50 ltrs capacity geyser .
Supply only Heating element 2000 watts capacity of any shape /type with rubber gasket . Make :- Ditz, Dass pass
Supply only Thermostat suitable to adjust the temperature from 0º C to 80º C all as directed. Make :- Ditz, Dass Pass
Supply only Glass wool of good quality as approved by Engr-in-Charge.
Supply only Neon indicator lamp of any shape / size / colour all as directed.
Supply only PVC insulated, sheathed 3 core flexible cable of size 2.5Sqmm all as directed.
Supply only Safety plug any type.
Supply only non return valve 15mm bore castcpper alloy suitablwe for geyser complete all as specified and as direceted
Supply only Rubber gasket of thickness 5 mm for geyser assembly of 08 holes / 09 holes all as specified.
Supply only Bottom inspection cover plate in two pieces with suitable openings for indicator lamps, power cable entry with rubber washer etc, gauge of plate not less than 18 SWG for 25/35/50 Ltrs capacity geysers of any make/ shape all as directed.
Supply only 3 pin plug top 15 Amps, bakelite suitable for 230/240 volts AC supply all as directed.
Supply only GI nut bolts and washers (not exceeding the size 150 mm x 12mm) of existing size of geyser spare parts
Supply only Outer MS shell complete including top and bottom suitable for 25 Ltrs capacity geyser of any make, shape & size as per existing but gauge of sheet not less than 22 SWG all as directed.
Supply only PVC connection 15mm bore 450mm long in any position with both end brass nut with inner thereading and washer suitable for cold water connection complete all as directed .
M/L for spray painting of geyser outer body of any make / size by applying one coat of synthetic enamel white paint over the existing paint including cleaning and preparation of surface, and writing of MES NO with synthetic enameled black paint in bold letters of size not less than10mm all as directed
Disconnecting & taking down complete ceiling fan with blade of any make 1200 mm / 1400 mm sweep from fan hook/ fan box, transporting to local workshop , opening, cutting and taking out complete copper winding , cleaning with kerosene oil /diesel/ terpin oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge and number of turns as recommended by the respective manufactures, varnishing and heating the winding including providing paper insulation (cuff/strip type) replacing u/s providing paper insulation (cuff / strip type) replacing u/s / missing spare (bush, bearing, capacity shackle insulator, canopy, nuts , bolts, earthing , screw, upper, socket, CI block , quarter /split pin (top & bottom) , lock nut etc) fixing the stator in rotor properly aligned and resembling ensuring right DOR, speedy and noiseless running and connecting cable and depositing in E/M yard complete all as directed by Engr in charge Note: Bush, bearing, capacitor, and canopy, shackle insulator with nuts, bolts and sockets shall be measured and paid for separately.
Supply only capacitor 2.50 MFD, 440 Volt AC, 50 Hz plastic body powder filled type complete all as directed.
Supply only capacitor 3.15 MFD, 440 Volt AC, 50 Hz plastic body powder filled type complete all as directed.
Supply only MS fan clamps with rubber real including nuts and bolts, split pin suitable for ceiling fan 1200 / 1400 mm sweep complete all as directed.
Supply only bearing suitable for 1200 / 1400 mm sweep ceiling fan complete all as specified and directed.
Supply only bush suitable for 1200 / 1400 mm sweep ceiling fan complete all as specified and directed.
Supply only PVC Canopy suitable for ceiling fan of 1200 / 1400 mm sweep set of two complete all as directed.
Supply only PVC insulated flexible 3 core, 1sqmm size copper conductor cable of size 1sqmm copper conductor including taking out the old unserviceable PVC flexible wire complete all as specified all as specified and directed by Engineer in Charge.
Supply & fixing for Mild Steel Down Rod of suitable dia , 45 Cms long white or coloured, compatible to existing ceiling fans of 1200mm or 1400 mm sweep including taking out old unserviceable down rod from the fan complete all as specified and as directed by the Engineer–in-charge. Down-Rod shall be of make of existing fan or as approved by the GE.
Disconnecting and taking down ceiling fan of any sweep for carrying out overhauling such as cleaning ,oiling, lubricating, greasing etc and replacement of minor parts such as washer, split pins/ blade screw etc and defective parts, if any, and refixing the ceiling fan fan on same location and connecting it properly and testing for noiseless running to the entire satisfaction of Engineer-in-charge. Note : (i). Defective parts required to be replaced shall be measured and paid for separately as supply only. (ii). Cost of the minor parts i.e. washer, split pins/ blade screw etc deemed to be included in unit rate & nothing shall be paid on this account.
M&L for Spray painting of ceiling fan 1200/1400 mm sweep and testing at site full load with super enamelled heat resistant synthetic white paint duly filling the cavities with filler and re-writing the MES number in black paint in appropriate size and shape complete all as directed by Engr-in-charge.
Disconnecting & taking down (burnt) exhaust fan of any make 300mm sweep transporting to local workshop, opening, cutting and taking out complete copper winding , cleaning with kerosene oil / diesel/ terpin oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge as recommended by the respective manufactures, varnishing and heating the winding including providing paper insulation (cuff /strip type) replacing u/s / missing spare (bush, bearing , capacity etc) fixing the stator in rotor properly aligned and reassembling ensuring right DOR , speedy and noiseless running and depositing in E/M yard Note: Bush bearing capacitor shall be measured and paid for separately.
All as per serial item No. 77 here-in-before but exhaust fan 450 mm sweep.
Taking down old and Supply and fix in repair capacitor 4 MFD, 440 Volt AC, 50 Hz plastic body powder filled type for exhaust fan of 300/400mm sweep complete all as directed.
Disconnecting and taking down exhaust fan of any sweep for carrying out overhauling such as cleaning ,oiling, lubricating, greasing etc and replacement of defective parts, if any, and refixing the exhaust fan fan on same location and connecting it properly and testing for noiseless running to the entire satisfaction of Engineer-in-charge. Note : (i). Defective parts required to be replaced shall be measured and paid for separately as supply only. (ii). Cost of the minor parts i.e. washer, split pins/ blade screw etc deemed to be included in unit rate & nothing shall be paid on this account.
Supply only bearing suitable for 300 / 400/ 450 mm sweep Exhaust fan complete all as specified and directed.
M&L for Spray painting of Exhaust fan and testing at site full load with super enamelled heat resistant synthetic white paint duly filling the cavities with filler and re-writing the MES number in black paint in appropriate size and shape complete all as directed by Engr-in-charge. (Bush, bearing, capacitor, canopy, shackle insulator with nuts, bolts and sockets will be measured and paid separately).
Collecting unserviceable (burnt) table / cabin fan of any make and sweep up to 450 mm from Internal Elect Section, transporting to local workshop, opening, cutting and taking out complete copper winding, cleaning with kerosene oil / diesel / terpin oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge as recommended by the respective manufacturers, varnishing and heating the winding including providing paper insulation (cuff / strip type), replacing unserviceable / missing spares (bush, bearing, capacitor etc), fixing the stator in rotor properly aligned and reassembling ensuring right DOR, speedy and noiseless running and depositing in E/M Yard for further issue to the user.
S & F in replacement of electronic energy meter single phase with LCB display 10-60A Cat no WM101BC7DLO of L& T or its equivalent HPL/Secure. Note : Old meter will be deposited to AGE E/M yard
Note:- Amount of credit of Rs. 24903.00 for retrieved materials is mentioned in Schedule of Credit Page No 108 of tender documents in pdf form which will be deducted offline while acceptance of tender.
M/S ASHWANI KUMAR & CO.
sanjeev electricals
GS Engineers
BANSAL ENGINEERING
SINGARI ELECTRICAL WORKS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .