| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.7 LAccepted-AOC 203 B CHAHBAI BAREILLY UP 243001 | BAREILLY | BAREILLY | UP | 243001 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹61.3 L+₹2.6 L (4.44%)Rejected-Finance 232 1 D SHIVLOK KANKARKHERA DISTT MEERUT UP PIN 250001 | MEERUT | MEERUT | UP | 250001 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹62.1 L+₹3.4 L (5.85%)Rejected-Finance 578 AVAS VIKAS JANAKPURI B IZATNAGAR BAREILLY 243122 UP | BAREILLY | UTTAR PRADESH | 243122 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹66.9 L+₹8.2 L (14.0%)Rejected-Finance A 91 DEFENCE COLONY AGRA CANTT AGRA UP 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-Finance Not being L1 |
Tender Value
₹6.9 L
EMD Value
₹1.3 L
Closing Date
4 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF BAREILLY
HQ CWE AF BAREILLY PIN 243002
PROVN OF INDOOR BADMINTON COURT AT AIR FORCE STATION BAREILLY
2023_MES_612979_2
81356/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF BAREILLY
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE AF BAREILLY
₹1.3 L
Yes
25 Nov 2023
13 Oct 2023
6 Nov 2023
13 Oct 2023
4 Nov 2023
23 Oct 2023
13 Oct 2023 - 15 Oct 2023
Amount
Excavating in trenches by manually , n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes,in soft/loose soil n exc 10 sqm on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Excavating over areas , n exc 1.5 m deep and getting out and getting out ,in soft/loose soil complete all as specified and directed.
Excavating over areasby , exc 1.5 m deep and n. exc 3.00 m deep and getting out and getting out ,in soft/loose soil complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft/loose soil complete all as specified and direcetd.
M & L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in in foundations, filling and mass concrete complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed.
Earth filling under floor for spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed. Note: Soil shall be used as obtained from excavation free from deleterious materials .
Removing excavated material (soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for steel formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surfaces of concrete complete all as specified and directed .
M&L for RCC M-25 (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M & L fro TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and directed.
All as per item No. 8 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binderscomplete all as specified and directed.
S&F for steel work in tubular trusses etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161- 1979 grade St.-240 complete all as specified and directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 10cm and not exc 15cm long and dia of neck 5 to 10mm dia, complete all as specified and directed
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exc 750mm long and dia of neck 16 to 20mm dia, complete all as specified and directed
M & L for Compound girders/Coulmns and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel or rectangular/square hollow sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. conforming to FE-410-W (Gde-E-250) quality -A or IS.1161- 1979 grade St.-240 complete all as specified and directed.
M & L for MS sheet as in base plates (plain or chequered), gusset plate etc welded or riveted to steel staircases including holding down bolts, nuts, rivets etc conforming to FE-410-W (Gde-E-250) quality -A complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating AZ-150, tensile strength 550 MPA corrugated steel sheet 0.50 mm total thickness (with coating and painting) of approved colour as in roof covering/cladding, fixed with self tapping screws (make hilty/fissers), neoprene and epdm washers class 3 of AS-3566(5.5-14X5 for crest and 5.5-14X25 for valley fixed) with 150mm end lap and one corrogation side lap whereever required penetrations and lap in sheet shall be sealed by using proper sealant profile/HDPE fillers shall be provided whereever required to close voids between sheets and fastners etc. as in roof covering/ cladding in straight or curved surface in any height complete all as specified and directed. Note : (i) The colour of sheet for bldg shall be approved by GE. (ii) Sheeting shall be fixed of any height.
S&F Pre- painted galvalume aluminum zinc coating AZ-150, tensile strength 550 MPA Plain steel sheet 0.50 mm total thickness (with coating and painting) of approved colour as in roof ridge, eaves, gutter factory made, match with roof sheetings, fixed with self tapping screws (make hilty/fissers), neoprene and epdm washers class 3 of AS-3566(5.5-14X5 for crest and 5.5-14X25 for valley fixed) with 150mm end lap and one corrogation side lap whereever required penetrations and lap in sheet shall be sealed by using proper sealant profile/HDPE fillers shall be provided whereever required to close voids between sheets and fastners etc. as in roof covering/ cladding in straight or curved surface in any height complete all as specified and directed. Note : (i) The colour of sheet for bldg shall be approved by GE. (ii) Sheeting shall be fixed of any height.
S&F PVC(SWR) pipes of dia 150mm single socketed in any length with rubber ring joints fixed to ceiling, wall with suitable clamps complete all as specified and directed.
M&L Broken stone or boulder Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
S&F for 100 mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base of floor etc complete all as specified and directed.
S&F for 75 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in floor etc finished even and smooth without using extra cement complete all as specified and directed.
M&L for granite 16-18mm thick (Black colour) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granitecomplete as in floors laid over and including 15mm thick screed bed in cement mortar (1:4), all as specified.
M&L for Glass dividing strips, 3 mm thick, 28 mm wide and inserted in position in PCC flooring complete all as spd and directed.
M&L for Epoxy Polyurethane flooring (Glossy/Matt) for badminton court system consisting of the following provisions complete all as specified and directed :- (a) preparing new existing flooring, mortars etc.by shot blasting, grinding etc (b) Cleaning the surface as specified here-in-after. (c) Shot blast/diamond grind the entire floor to remove foreign material/carbonate materials if required. (d) Filling the dents and cracks with suitable epoxy putty or mortar followed by application of epoxy primer, where required (v) making existing surface free from dust including making good existing expansion/construction/dummy joints with out disturbing their position. (e) Applying 2 coats of primer of 60 micron each. "Apcoflor HFP 120" Ist quality ISI Marked Paint (f) Applying 2mm thick Apcofloor LSC 3 screed Ist quality ISI Marked Paint (g) Aplying 2mm thick (minimum) self levelling finish coat of " Apcoflor EPU SL-2, Ist quality ISI Marked Paint complete all as specified and manufactures instructions. Note :- (i) Entire treatement to be carried out by official applicator of approved product. (ii) Work to be executed in occupied hanger and the work in restricted area.
M & L for line marking of Badminton Court with Hi-Lide paint of approved make of standerd diamention as per international badminton standards complete all as specified and directed.
M & L for brick work with sub class B, old sized Flyash brick, staright or curved on plan exc 6M mean radius and built in CM 1:6 complete all as specified and directed.
M & L for 15 mm thick rendering in CM 1:6 on stone masonry or brick work orstone masonry surfaces or surface other than fair face of brick-work finishing the surface even and smooth without using extra cement complete all as specified and directed
M & L for 15 mm thick rendering in CM 1:4 on stone masonry or brick work or concrete surfaces and finishing the surface even and smooth without using extra cement complete all as specified and directed
M & L for preparation of new plastered surfaces of wall and applying a layer of Wall care putty and two coat of oil bound distemper over a coat of primer complete all as specified and directed.
M & L for preparation of new plastered surfaces of wall and applying two coat of cement base paint complete all as specified and directed.
S&F for 75 mm thick PCC 1:3:6 type C-2 (using 20 mm graded stone aggregate) as in plinth protection etc complete all as specified and directed.
S&F providing and fixing factory made UPVC white colour casement/sliding window/door, made of extruded profiles. Profiles of frames and sash will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc, making arrangement for fixing of hardware, EPDM gasket, 1.2+_ 0.2mm thick galvanized steel profile to be inserted in required profile, frame will be fixed to the wall/steel frame with 8mm x 100mm long fasteners, all complete and as directed including 02 Nos of 150mm handles and necessary locking arrangements with following specifications :-- Sliding door two track, 2/4 shutters) 1. Two track sliding frame (60mm x 62mm) 2. sliding door sash (85mm x 42mm) 3. Sliding interlock for door (one vertical length in each shutter) (45.5mm x 28mm) 4. Sliding glass bead (24.5mm x 16mm) 5. Reinforcement frame (30mm x 21.5mm) x 2 Nos 6. Reinforcement sash (30mm x 28mm
S&F 12mm thick toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required, complete all as specified and directed.
S & F for rolled MS framed work as in doors or gate of angle or other section with gusset plate, rail, brases etc , including either hooks and hinges or steel hanging door fitting to be prepared for hanging and also fastening conforming to Fe 410-0 or 310-0 complete all as specified & directed.
M & L for preperation of new steel surfaces over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Removing excavated material to a distance exc. 1.50 km but n exc. 5 km and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified & directed.
Rolling and consolidating formation surfaces in cutting to required , level, gradient and camber including depression with 8 to 12 tonne roller complete all as specified and directed.
M&L for 150 mm thick (compacted thickness) PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub base of road complete all as directed.
M&L for 200 mm thick (compacted thickness) PCC M-25 design mix (using 20mm graded crushed stone aggregate) as in pavement/floor casted in panels complete all as directed.
M&L for Finishing the surface concrete by brooming while the concrete is still green complete all as specified and directed.
M&L for forming 12 mm wide expansion joint , filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade 'A' for 200 mm thick concrete slab and complete all as specified and directed.
M&L for forming Construction joint 10mm wide and 30mm deep by cutting with diamond cutter and filled with sealing compound Grade 'A' complete all as specified and directed.
M&L for forming Contraction (Dummy) joint 65mmx10mm wide by cutting with diamond cutter and filled by sealing compound grade 'A' complete all as specified and directed.
M&L for Point Wiring complete with 2.5 Sqmm FR-LSH, PVC insulated unsheathed copper conductor single core multi stranded cable 650/1100 volts grade drawn in and including surface non-metallic rigid PVC conduit medium grade with all fittings (ISI Marked) not less than 20 mm external dia but shall be increased as per actual site reqmt in accordance with clause no 19.125 of SSR part I fixed in surface / recessed in wall / ceiling etc including 2.5 Sqmm FR-LSH, PVC insulated unsheathed copper conductor single core multi stranded cable 650/1100 volts grade as earth continuity wire including MS sunken pressed steel terminal boxes of suitable size , made of sheet 1.6mm thick with 3.0 mm thick bakelite sheet top cover one 3 pin 15 or 16 Amp socket outlet on independent board complete all as specified.
S&F switch piano flush type one way 16 amps SP 240 volts complete all as specified and directed.
S&F socket outlet 2 in 1, 5 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed.
S&F LED Flood light fitting 100W, made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 roadway luminaire with high power LED as light source 1 x 100 Watt, LED 6000K, complete with all accessories internally pre-wired including fixing arrangements such as clamps, nuts & bolts etc as per site requirement complete all as specified and directed.
M&L for sub main wiring with two single core 2.5 Sqmm PVC insulated unsheathed multi stranded copper conductor cable 1100 volt grade drawn in and including medium grade 25mm dia PVC conduit & accessories fixed on surface including making good disturbed surface of ceiling/ wall including one core multi stranded copper conductor 2.5 Sqmm size as earth wire drawn in same conduit complete all as specified and as directed. NOTE :- Two runs of 2.5 Sq.mm & one run of 2.5 sq.mm & one run of PVC conduit with accessories shall be measured as One length.
S&F for flush mounting factory made TPN DBs Double door, IP-43 protection - IK 09 with metal door with neutral busbar, earth bar cables ties for cable management fully insulated busbar 4 Way etc complete all as specified and directed.
S&F MCB Triple pole and neutral, 415 Volts, 40 Amps, breaking capacity, 10 KA, 'C' series etc complete all as specified and as directed.
S&F MCB Single pole, 240 Volts, 6 to 32 Amps, breaking capacity, 10 KA, 'C' series etc complete all as specified and as directed.
S&F Blanking plate suitable for MCB TPN DB complete all as specified and as directed.
Supply, installation, commissioning and testing of air turbo ventilator for Indoor Badminton Court roof at a height of above 15 m comprising of the following specifications: - (a) Turbine dia - 27 Inches (b) Throat dia - 24 Inches (c) Height - 15.5 Inches (d) Vanes/ Blades - SS 202 Grade (e) Base Ring - Polypropylene (f) Top plate - SS 202 Grade (g) Rotation - Twin Bearing Ensure Frictionless, Rotation even at low wind velocity (h) Center Shaft - M.S Electro Zinc Plated (j) Inner Arms - Polypropylene (k) Outer Arms - Polypropylene (l) Bearing -Twin sealed 6201, 6202 2RS Self Lubricating & Sealed (m) Screws - Steel Finish Screws Note :- Rate quoted deemed to include for making cutting drillig size opening in Galvalume sheet roofing as shown on drawings for fixing turbo ventiloators
Supply, laying & testing of LT Cable XLPE insulated, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts, grade cross setional area 25 Sqmm 4 Core complete all as specified and as directed.
Supply, laying & testing of LT Cable XLPE insulated, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts, grade cross setional area 16 Sqmm 4 Core complete all as specified and as directed.
M&L for sub class 'B' bricks old size, as cable mechanical protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Sand cushioning to under ground cables, 8 cm thick layer before laying and testing the cable and 15 cm thick after laying and testing of the cable in trenches complete all as specified in Clause 19.75 of MES SSR 2009 Part-I and directed by Engr-in-Charge. Note: Punned down thickness shall only be measured and paid to contractor
Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar of overall size not less than 1050mm width x 800mm Height (Without Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 450mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 100 Amps, Provision of Spreader link to incoming side of MCCBs for termination of cables and 4 way ebonite cable connector (rating 32 amps) for termination of outgoing cables with MCBs.The Feeder Pillar shall be as conforming to IS/ IEC 61439 1&2 , rated fault of 65KA for 1 sec with internal arc containment Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032
(SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :- Location :- LT Panel Badminton Court
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided in the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant,high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 100 Amps, . For all internal connections from main bus bars to switch gears shall be carried out with suitable size FRLS grade PVC insulated multiflexible type copper wire as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm. INCOMING :- 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 16 KA Fixed magnetic and Fixed thermal setting of rating 63 Amps. OUTGOINGS :- TPN/SPN MCB having breaking capacity 16 KA , (i) TPN 40 Amps - 02 Nos , (ii) SPN 40 Amps - 02 Nos ( 1 No & 01 No Spare)
Note : 1) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar. 2) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar. 3) All the inner / outer doors should have locking facility through castle locks 4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. 5) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department. 6)The thickness of MS Sheet for outer shell and canopy shall be of 3.0mm and inner doors and partitions shall be of 2.0 mm. 7) The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments. 8) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process.
S&F MCCB 63 Amps 4 pole 415 Volts 16 KA Amps with MS enclouser fixed in Existing LT Panel
M&L for mild steel galvanised light grade 25mm dia tubing with all fitting; laid in trenches, across road or on pole complete all as specified.
M&L for mild steel galvanised light grade 50mm dia tubing with all fitting; laid in trenches, across road or on pole complete all as specified.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm GI Strip continuity earth conductor complete all as specified and as directed.
M&L for Earthing complete with galvanized steel earth plate 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanized iron strip size 32x6mm as earthing lead by means of bolt ,nuts, check nuts and washer of galvanized iron or steel besides welding of all joints as shown in drawing and including excavation and earth work, G.I.pipe light grade 40 mm bore for protection of G.I.strip from earth electrode to and including the earth test point of galvanised iron /steel of size 75 x75x 25 mm , supplying and laying charcoal dust, common salt PCC 1:2:4 type B-I using 20 mm stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate no 3 of SSR Part I of 2009 and connected to earth test point & testing including dismantling and taking out old U/S Earthing materials complete all as specified and directed. Note :- Cost of earthing strip & GI pipe 40mm up to 7.5 m shall be included in cost of above item.
Shikhar ji Enterprises
UTTRAKHAND BUILDERS
M/s Shrangi Rishi Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .