Loading…
Loading…
Tender ID
Tender Value
₹25.1 L
EMD Value
₹25,100
Closing Date
30 Mar 2026, 6:00 pmClosed
EXECUTIVE ENGINEER
Special repair to Streetlight and related items in RB and New Parade Ground, Baffle Range, Barrack (G+3), Gurudatt building and Main Road at SRPTC, Chowky, Dist:- Junagadh
282993
20 [2025-2026]
Open
Civil - All
Works
Junagadh
9 documents required · 7 mandatory · 2 optional
₹1,500
GUJARAT STATE POLICE HOU.CORPORATION LTD.
₹25,100
9 Mar 2026
9 Mar 2026
9 Mar 2026
30 Mar 2026
9 Mar 2026
No. In Figure In Words
1 Providing & Erecting 2.0 mtr. long Earthing system by making minimum 4.00 Each 7025.00 Rupees Seven
bore of 225 mm dia. in soft soil. Suitable for doing pipe-in-pipe Thousand Twenty Five
technology earthing. Earthing electric rod must be made from Corrosion Only
free hot dip galvanizing pipes having following specification.
(A) Earthing Electrode: outer Pipe: - 88 mm minimum O.D., 'B ' Class
ISI mark of Reputed Brand, Inner pipe: - 42 mm minimum O.D., Pipe B
Class ISI mark reputed Brand. Terminal Size: 70 mm X 100 mm length,
Terminal should be made from inner pipe for that pipe must be pressed
and gave rectangular shape so its work as a terminal. The hot deep
galvanising must be done after above process. Galvanised thickness
must be minimum 75 micron anywhere. SS Nut bolt:- 2 nos. with
washer suitable for 14 mm dia. hole must be provided at terminal. Total
minimum Weight (approx.) of earth electrode with inside conductive
material be 26 kg.
(B) Inner chemical (CCM Compound):- Resistivity:- 0.2 ohm/ meter
testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry
form, Sulphur content:- <2%
(C) Back fill Compound:- Earthing compound should be capable to
retain moisture for long time. Back Filling Compound weight is 25 Kg.
(D) Chamber and cover:- Earthing chamber should be size of 400 mm
X 400 mm X 400 mm depth and Cover should be heavy duty cast iron
with required size of 300 mm X 300 mm X 4 mm thick.
It. Estimate Quoted Rate in Rs.
Description of Item Qty Unit Amount
No. In Figure In Words
Necessary test report must be submitted.
1. Short circuit test by ERDA/ CPRI for 25KA
2. Resistivity test of conducting material from NABL accredited lab.
3. Hot dip galvanised / zinc coating micro test from reputed laboratory.
4. General test report from OEM regarding specification of earthing.
[Make and model approved by EIC Strictly subject to item specification
only] [OEM has to submit all detail & sample for approved before
supplying]
[Water must be poured in bore before starting earthing. Earthing value
must be measured with earth tester. Agency has to bring the earth
resistance to at least 02 ohms & voltage between neutral & Earthing
upto 02 volt. Agency has to maintain earthing & its value for one year.
Earthing must be done in the presence of A.E. (GSPHCL)]
2 For Earthing Additional charges for boring in hard rock soil (by 4.00 Each 276.00 Rupees Two Hundred
Breaker)& filling soft soil in earth pit. (Certificate for soil have to given Seventy Six Only
by DEE/AE along with Photographs)
3 Providing & fixing double compressed heavy duty flange type brass 150.00 Each 43.00 Rupees Fourty Three
cable gland with rubber ring for P V C insulated armoured cable Only
complete with outgoing tails, insulating tape etc. For following size
cables.. For 2 to 4 core x 4.0 Sq. mm (Sigma, MCI, Comet Make
4 Supplying & erecting 12 mm thick Hylum sheet on existing 25 x 25 x 3 2.00 Sq. 2289.00 Rupees Two
mm red oxide painted angle iron frame suitable for fixing ICDP / ICTP / Mtr. Thousand Two
DPMCB / FPMCB SWITCH and energy meter (contractor shall make Hundred Eighty Nine
approved drawing of Hylum sheet to arrange required No. of Energy Only
meter & ICDP / ICTP / DPMCB / FPMCB switch-busbar etc. as per
Actual space available in electrical room at site)
It. Estimate Quoted Rate in Rs.
Description of Item Qty Unit Amount
No. In Figure In Words
5 Providing & Erecting Mains with ISI marked, 1.1 KV grade electrolyte 300.00 Mtr 141.00 Rupees One Hundred
multi stranded, annealed copper conductor with heat resistant PVC Fourty One Only
insulated conforms to IS:694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel, relays, power switchgears,
motor starters & control wiring) with required size of copper lugs, nuts
and bolts if required. (Conductor resistance should be as per
IS:8130/1984) One wire 16.00 sq. mm
6 Providing and erecting bracket consisting of ISI mark "B" class G.I. 34.00 Each 487.00 Rupees Four Hundred
Pipe 4.2 cm outside diameter complete with suitable G.I. Sleeve tubing Eighty Seven Only
of 2 mm. thick and required size and length suitable for 76.5 / 80 mm.
required size of pole top having nuts and bolts for fixing the brackets
and having spread of Upto 0.70 mtr. length with suitable rise as per
site condition and suitable welded stiffner reducer and nipple with
check nut complete painted with one coat of red oxide and two coats of
alluminium paint. or Single arm bracket suitable for terrace as per
design given by EIC (Jindal / Asian / Tata / Surya Prakash make Only)
(FabricatoRupees - Ambica / Fab / Bajaj / Impression equipment Only)
(Test certificate to be submitted) (a) For Single arm bracket
7A Providing and erecting bracket consisting of ISI mark "B" class G.I. 25.00 Each 608.00 Rupees Six Hundred
Pipe 4.2 cm outside diameter complete with suitable G.I. Sleeve tubing Eight Only
of 2 mm. thick and required size and length suitable for 76.5 / 80 mm.
required size of pole top having nuts and bolts for fixing the brackets
and having spread of 1.00 mtr. length with suitable rise as per site
condition and suitable welded stiffner reducer and nipple with check nut
complete painted with one coat of red oxide and two coats of
alluminium paint. or Single arm bracket suitable for terrace as per
design given by EIC (Jindal / Asian / Tata / Surya Prakash make Only)
(FabricatoRupees - Ambica / Fab / Bajaj / Impression equipment Only)
(Test certificate to be submitted) (a) For Single arm bracket
It. Estimate Quoted Rate in Rs.
Description of Item Qty Unit Amount
No. In Figure In Words
7B For Double arm bracket 19.00 Each 821.00 Rupees Eight Hundred
Twenty One Only
8 Supplying following size of Light duty “A” Class G.I . Pipe & erecting 130.00 Mtr. 171.00 Rupees One Hundred
as directed by Engineer-in-charge. (a) For 25 mm dia Seventy One Only
9 Supplying & erecting approved make SMC press moulded 70.00 No 890.00 Rupees Eight Hundred
composite FRP loop-in, loop-out approx. 2mm thick box complete with Ninety Only
Bakelite connector strip 5way(3P+N+E),DIN rail for mounting mob &
hinged doors as per requirement having locking arrangements with
mounting clamp with nuts, bolts & washers suitable for erection on pole
with cable clamps& earth bolt of following size of box. (A) 300 mm x
200 mm x 100 mm [deep]
10 Providing & making 1:2:4 cement concrete foundation & 70 % 5.00 Each 801.00 Rupees Eight Hundred
PCC from bottom including excavation for the pole of size 45 x 45 x One Only
100 cm. Deep in below ground level with plinth of 45 cm x 45 cm (or
cm dia x 45 cm) high upper ground level with necessary curing and
finishing in approved manner.
( for 4 & 6 mtr pole)
11 Breaking existing C.C. Foundation upto 0.5 mtr level and make the 23.00 Each 950.00 Rupees Nine Hundred
new C.C Foundation as per above item for the same. Fifty Only
12 Providing and making of Coil Type Earthing Having coil Made From 8 63.00 Each 369.00 Rupees Three
SWG Hot Deep Galvanized iron Wired wrapped On 50 MM OD Round Hundred Sixty Nine
Pipe Having Minium 50 Turn( Approximately 200 mm lenght) & Having Only
Contineous lenght Of 3 Mtr Gi wire To Connect Earthing Bolt & Burried
In Specially Prrepared Earth Pit Complete With Salt & Charcoal/Coke
As Required For Coil Type Earthing (Approximately Weight Of Coil
It. Estimate Quoted Rate in Rs.
Description of Item Qty Unit Amount
No. In Figure In Words
13 Drilling the road without breaking the road surface (Asphalt) for 30.00 Mtr. 488.00 Rupees Four Hundred
laying of cable for feeding power supply by making up to following size Eighty Eight Only
of holes at both ends complete. (A) Up to 100 mm bore dia.
14 Providing, erecting, fabricating the M.S. structure as per requirement 150.00 Kg. 75.11 Rupees Seventy Five
of site as per structure design Including proper size approved by EIC and Paisa Eleven
of M.S. angles, flats, bars, square pipe, channels, sections (Tata, Only
Jindal, Asian, JSI Make) complete with cutting, welding, grinding and
finishing duly painted with Asian/Nerolac make premium quality oil paint
and true care red oxide metal primer,asian paint make with erection on
site as per direction of engineer in charge with necessary grouting
cementing, plastering and finishing complete. All hole opening of
square pipe end must be closed with M.S plate welding. Payment will
be done on KG as per Actual weight.
15 Providing & Erecting Flexible PVC insulated multistrand multicore 1.1 450.00 Mtr. 46.00 Rupees Fourty Six
kv grade ISI marked copper wires of following size to be erected as Only
directed. (a) 3 core 1.5 sq.mm. PVC insulated round copper wire ISI
16 Providing & Erecting Flexible PVC insulated multistrand multicore 1.1 260.00 Mtr. 77.00 Rupees Seventy
kv grade ISI marked copper wires of following size to be erected as Seven Only
directed.(b) 3 core 2.5 sq.mm. PVC insulated round copper wire ISI
17 Providing & erecting approved make XLPE (IS:7098) (I)-88 ISI mark 2900.00 Mtr. 361.00 Rupees Three
armoured multistrand Copper Cable 1100 volt to be laid 90 cms. Hundred Sixty One
Under ground or to be laid on wall with 1.0 mm thick G.I. heavy guage Only
cable clamp or in existing DWC pipe underground or road crossing or
floor of following size of cables.(d) For 4 core x 4.0 mm2
It. Estimate Quoted Rate in Rs.
Description of Item Qty Unit Amount
No. In Figure In Words
18 Providing & fixing Solderless crimping type Copper lugs conforming to 1200.00 Each 8.00 Rupees Eight Only
IS suitable for cable of following size evenly crimped with high pressure
tool & connected to switchgear terminals with brass/cadmium plated
nut bolts in an approved manner. (A) 1.5/2.5/4/6 Sq.mm.
19 Providing & laying HDPE Double walled corrugated pipes (DWC) 1850.00 Mtr. 117.00 Rupees One Hundred
(conforming to IS: 16205 (part 24) 2018)) with minimum load required Seventeen Only
of 450N capacity with anti rodent and ultra violet material properties
with necessary connecting accessories of same material at required
depth to be laid 90 cms. under ground for laying of cable below
ground / road surface for enclosing cable and back filling the same to
make ground as per original. (A)For Outer dia.50 mm and Inner dia.
38mm (Test Certificate to be Submitted)
20 Supplying and erecting Galvanized iron pipe post ISI mark 'B' class 11.00 Each 4397.00 Rupees Four
88.9 mm. O.D. 6 mtrs. Long duly painted with two coats of alluminium Thousand Three
paint and metallic base plate of 300 x 300 x 4 mm. thick to be erected Hundred Ninety Seven
as a compound light pole with wire entry nipple and earthing bolt. Only
Approximate weight of pole 47 Kg. within permissible limits as per IS
effective length of sections Bottom: 5.5 mtr. having outside dia.
mm. Top: 0.5 mtrs. having outside dia. 76.1 mm. ( ISI test certificate
from pipe manufacture & Class/make/length/O.D/wall thickness/GI/ MS/
Weight test certificate from pole manufacture shall be submitted)
(Jindal / Asian / Tata / Surya Prakash make only For G.I Pipe)
(Manufacturer's make Ambica,Fab,Bajaj only,Test Certificate to be
Submitted)
It. Estimate Quoted Rate in Rs.
Description of Item Qty Unit Amount
No. In Figure In Words
21 Supplying and erecting approved make Octagonal pole made from HR 20.00 Each 11410.00 Rupees Eleven
sheet steel. The pole should be made as per IS. and shall be coated Thousand Four
with hot dip galvanizing as per IS 2629/2633/4759, suitable suspend Hundred Ten Only
local wind speed with integral Junction box with Hot Deep Galvanised
door having 2 nos. 180° operated hinges & 2 nos. Ln key locking with
silicon rubber gasket. Consist of terminal plate of min 6mm Hylam
sheet, standard profile 35mmX7.5mm Din-Rail & MCB , Brass stud
type terminal and arrangement for cable termination to be erected on
RCC foundation as per details given by manufacturer and EIC
considering site requirement.
Foundation Details: 1) Grade of RCC 1:2:4, 2) Grade of steel
rainforcement of RCC FE 415, 3) Clear cover to rainforcement 50mm,
4)Concrete vibrated, 5) use suttering / farma, 6)Hot deep galvanized
average 70Micron, 7) Detail drawing will be given by corporation.
(Make:- Bajaj, Valmont, Ambica, Transril)
(E) 7 Mtr. Long 70 mm Top X 135 mm bottom dia, 3 mm thickness
with 225mmX225mmX16mm base plate, 4-M20 Bolts and 600mm long
hot deep galvanized J-Bolt, nuts, washers with 1300mm under ground
and 200mm above ground level and 450mm dia. Foundation in 1:2:4
proportion.
22 Painting of Streetlight pole with bracket complete with primer with two 41.00 Each 263.00 Rupees Two Hundred
coats of Aluminium paint for following size of pole.Up to 6 Mtr. Sixty Three Only
23 Providing & erecting 240 V MCB double pole switch for motor & 5.00 Each 327.00 Rupees Three
inductive load (C Curve) having 10 KA breaking capacity & confirms Hundred Twenty
to IS : 8828 in existing box having following capacity (B)For 40 Amp. Seven Only
It. Estimate Quoted Rate in Rs.
Description of Item Qty Unit Amount
No. In Figure In Words
24 Providing and erecting Medium Class FIA approved and ISI mark white 250.00 Mtr. 33.00 Rupees Thirty Three
colour (embossed) RIGID PVC PIPES of following size complete Only
erected with necessary PVC fittings & Junction boxes fixed with
adhesive solution & clamps on / in wall / ceiling along with continuous
fish wire to draw mains with necessary fittings and junction boxes for
following dia. For 25 mm dia.
25 Providing, erecting, testing and commissioning insu intelligent street 3.00 Each 20255.00 Rupees Twenty
light controller specially designed for energy saving in conventional Thousand Two
street light system ( Cat. no. SLC-03-1Ph-15 KVA-20 Amp. per phase) Hundred Fifty Five
having technical specification, 1 phase 2 wire, 230 V AC/ph, +/- 25% R Only
Y B N 2 wire supply system, 50 Hz (+/- 10%) 2 W (Stand BY) to 4 W (at
street light operation) consumption, Advance 8 bit micro controller,
switching on longitude and latitude base, accuracy of +/- 1 minute per
month, with in built battery, with battery life of more than 8 years, with
special device which hold the parameter for more than 10 year without
any power and password protected.
16 characters and two line LCD display with backlight, 4 keys user
friendly keyboard system, 7500/15000 VA feeder pillar capacity, 60/100
Amps isolator, 3 output with termination, 40/63 Amps 2/3 pole
contactor, 3 X 16 Amp., with FR cable provision to by pass by way of
relay operation through auto/manual switch, 2 to 55 centigrade and
humidity 90 % non condensing, Out door type installation on pole with
clamps (Provided with clamps and nut bolt) or wall or floor, Three
locking system flush type internal panel lock, external pad lock and
internal U clamp locking systems for against theft of Panel, having
17/25 Kg weight, 18 Gauge MS weather proof box with industrial
exterior powder coated with 7 tank process RAL
It. Estimate Quoted Rate in Rs.
Description of Item Qty Unit Amount
No. In Figure In Words
26 Providing & Erecting Univesal Astro interlligent Street light Control 2.00 Each 12895.00 Rupees Twelve
Syatem insu with weather proof box for indoor allplication 5KVA ( as Thousand Eight
Per atteched Specification) Hundred Ninety Five
27 SITC of Outdoor aesthetically designed LED Street Light Luminaire 73.00 Each 3512.00 Rupees Three
with total consumption of Max. 45 W with single piece die cast Thousand Five
aluminium housing, high power LED shall be mounted on high quality Hundred Twelve Only
metal core PCB with extremely precison designed heat sink complete
with IP66 protection Class with polycarbonate / thoughened glass cover
the fixture should be suitable for pole/bracket mounting. The fixture to
comply both LM79 and LM 80 guidelines with LED module min.
lumen/watt with toughen Glass L70 at 50,000 hrs, provided with high
quality polycarbonate lenses for better light distribution. The Fixture
Should be able to be Pole Mounted and also bracket mounted,
provided with high quality driver for protection against high and low
Voltage cut Off, opertional for high amibient and high humid
envirnoments, THD of driver should be less than 10% and P.F > 0.95.
Also the Fixture should meet the following technical criterias Oprating
range Voltage 160 to 270 V, system efficiency >= 110 lm/w, and total
lumens not less then 4950, CCT > 5000K, CRI > 65, beam angle
deg, 4kV integral & non integral surge immunity level at least 10 KV
non integral..The Separate Potted driver should have over current, over
voltage protection, short circuit protection so that the fixture recovers
once the fault is removed. In addition to the above product should be
operational in the temperature range of 0 deg to 50 deg and humidity
range of 10% to 90% RH. (Note:- The manufacturer / authorized
Channel partner of the manufacturer has to submit 5yrs free
replcement Guarantee for complete Fixture)
It. Estimate Quoted Rate in Rs.
Description of Item Qty Unit Amount
No. In Figure In Words
28 SITC of Outdoor aesthetically designed LED Street Light Luminaire 13.00 Each 6701.00 Rupees Six Thousand
with total consumption of Max. 120 W with single piece die cast Seven Hundred One
aluminium housing, high power LED shall be mounted on high quality Only
metal core PCB with extremely precison designed heat sink complete
with IP66 protection Class with polycarbonate / thoughened glass cover
the fixture should be suitable for pole/bracket mounting. The fixture to
comply both LM79 and LM 80 guidelines with LED module min.
lumen/watt with toughen Glass L70 at 50,000 hrs, provided with high
quality polycarbonate lenses for better light distribution. The Fixture
Should be able to be Pole Mounted and also bracket mounted,
provided with high quality driver for protection against high and low
Voltage cut Off, opertional for high amibient and high humid
envirnoments, THD of driver should be less than 10% and P.F > 0.95.
Also the Fixture should meet the following technical criterias Oprating
range Voltage 160 to 270 V, system efficiency >= 110 lm/w, and total
lumens not less then 13200, CCT > 5000K, CRI > 65, beam angle
deg, 4kV integral & non integral surge immunity level at least 10 KV
non integral..The Separate Potted driver should have over current, over
voltage protection, short circuit protection so that the fixture recovers
once the fault is removed. In addition to the above product should be
operational in the temperature range of 0 deg to 50 deg and humidity
range of 10% to 90% RH. (Note:- The manufacturer / authorized
Channel partner of the manufacturer has to submit 5yrs free
replcement Guarantee for complete Fixture)
It. Estimate Quoted Rate in Rs.
Description of Item Qty Unit Amount
No. In Figure In Words
29 SITC of Outdoor aesthetically designed LED Flood Light Luminaire 21.00 Each 6228.00 Rupees Six Thousand
with total consumption of maximum 90 W with single piece die cast Two Hundred Twenty
aluminium housing, LED's mounted on high quality metal core based Eight Only
PCB with extremely precison designed heat sink, complete with IP66
protection Class, with polycarbonate / Toughened glass cover. The
fixture should be suitable for pole/bracket mounting. The fixture to
comply both LM79 and LM 80 guidelines with LED minimum
lumen/watt with L70 at 50,000 hrs, provided with high quality
polycarbonate Seperate lenses for better light distribution. The Fixture
Should be able to be Pole Mounted and also bracket mounted,
provided with high quality potted driver for protection against, high and
low Voltage cut Off, opertional for high amibient and high humid
envirnoments, THD of driver should be less than 10% and P.F > 0.95.
Also the Fixture should meet the following technical criterias. Operating
range Voltage 160 to 270V, system efficiency > 110 lm/w, CCT >
5000K, CRI >65, beam angle 120 deg, 4kV integral & non integral
surge immunity level at least 10 KV non integral... Flood Light lumens
shall be more than 9900 (Note:- The manufacturer / authorized
Channel partner of the manufacturer has to submit 5yrs free
replcement Guarantee for complete Fixture)
It. Estimate Quoted Rate in Rs.
Description of Item Qty Unit Amount
No. In Figure In Words
30 SITC of Outdoor aesthetically designed LED Flood Light Luminaire 6.00 Each 7395.00 Rupees Seven
with total consumption of maximum 120 W with single piece die cast Thousand Three
aluminium housing, LED's mounted on high quality metal core based Hundred Ninety Five
PCB with extremely precison designed heat sink, complete with IP66 Only
protection Class, with polycarbonate / Toughened glass cover. The
fixture should be suitable for pole/bracket mounting. The fixture to
comply both LM79 and LM 80 guidelines with LED minimum
lumen/watt with L70 at 50,000 hrs, provided with high quality
polycarbonate Seperate lenses for better light distribution. The Fixture
Should be able to be Pole Mounted and also bracket mounted,
provided with high quality potted driver for protection against, high and
low Voltage cut Off, opertional for high amibient and high humid
envirnoments, THD of driver should be less than 10% and P.F > 0.95.
Also the Fixture should meet the following technical criterias. Operating
range Voltage 160 to 270V, system efficiency > 110 lm/w, CCT >
5000K, CRI >65, beam angle 120 deg, 4kV integral & non integral
surge immunity level at least 10 KV non integral... Flood Light lumens
shall be more than 13200 (Note:- The manufacturer / authorized
Channel partner of the manufacturer has to submit 5 yrs free
replcement Guarantee for complete Fixture)
31 Supplying & fixing box for housing ELCB + MCB combination made 5.00 Each 272.00 Rupees Two Hundred
of 18 SWG sheet steel duly powder coated with gasket, dust & vermin Seventy Two Only
proof bakelite shield two earthing terminals for following type of RCCB,
ELCB, ELCB + MCB (a) For 2 pole
Total in Rs. →
Contractor Signature Ex.Engg,(Ele.)(SP)
G.S.P.H.C.Ltd,
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1 SBD Book Choki Street Light.pdf
2 SCH B Choki Street Light.pdf
3 Electrical Booklet 2024.pdf
New Jaher Nivida 2025-26 (20).pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .