Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 CrAdmitted-Finance KARIMKUTTIYIL BUILDINGS ANGADI P O RANNI PATHANAMTHITTA 689 674 | PATHANAMTHITTA | KERALA | 689674 | ₹5.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹5.0 CrAdmitted-Finance | ₹5.0 Cr | L2 | Admitted-Finance |
| 3 | L3₹5.1 CrAdmitted-Finance BANKERS VILLA VAZHOTTUKONAM VATTIYOORKKAVU P O TRIVANDRUM 695 013 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695013 | ₹5.1 Cr | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | DORA INFRASTRUCTURES AND PROPERTIES Pvt LIMITED L1 | Bankers Construction L3 | K V JOSEPH AND SONS PRIVATE LIMITED L2 |
|---|---|---|---|---|---|---|
| 0.00CIVIL WORKS | ||||||
| 1.00SITE CLEARENCE | ||||||
| 1.01 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees andsaplings of girth up to 30 cm measured at a height of 1 m above ground level andremoval of rubbish up to a distance of 50 m outside the periphery of the area cleared | 875 | sqm | 20 ₹17,500 | 18.5 ₹16,187.50 | 19 ₹16,625 |
| 1.02DISMANTLING AND DEMOLISHING | ||||||
| 1.03 | Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking thematerial within 50 metres lead of :G.S. Sheet | 35 | sqm | 180 ₹6,300 | 168 ₹5,880 | 165 ₹5,775 |
| 1.04 | Taking out existing CC interlocking paver blocks from footpath/ central verge,including removal of rubbish etc., disposal of unserviceable material to the dumpingground, for which payment shall be made separately and stacking of serviceablematerial within 50 metre lead as per direction of Engineer-in-Charge. | 68.25 | sqm | 150 ₹10,237.50 | 137.5 ₹9,384.38 | 138 ₹9,418.50 |
| 1.05 | Dismantling steel work in built up sections in angles, tees, flats and channelsincluding all gusset plates,bolts, nuts, cutting rivets, welding etc. includingdismembering and stacking within 50 metres lead. | 123.4 | kg | 7 ₹863.80 | 6 ₹740.40 | 7.5 ₹925.50 |
| 1.06EARTH WORK EXCAVATION WORKS | ||||||
| 1.07 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil | 472.1 | cum | 385 ₹1.8 L | 362.5 ₹1.7 L | 345 ₹1.6 L |
| 1.08 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | 377.68 | cum | 360 ₹1.4 L | 320.2 ₹1.2 L | 310 ₹1.2 L |
Tender Value
₹5.0 Cr
EMD Value
₹2 L
Closing Date
19 Feb 2026, 3:00 pmClosed
ASSOCIATE VICE PRESIDENT
HLL Lifecare Limited, HLL Bhavan, No26/4, Tambaram-Velachery Main Road, Pallikaranai, Chennai 600 100, Tamilnadu
Construction of New MCH Block at GH Kanjirapally, Kottayam District, Kerala
2026_HCDPS_835029_1
HLL/CMO/HCD/KNP-KTM/25-26
Open Tender
Civil Works - Buildings
540 days
GH Kanjirapally, Kottayam District
Please refer Tender documents.
20 documents required · 20 mandatory
₹11,800
Yes
₹2 L
Yes
27 Feb 2026
9 Feb 2026
20 Feb 2026
9 Feb 2026
19 Feb 2026
9 Feb 2026
CIVIL WORKS
SITE CLEARENCE
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees andsaplings of girth up to 30 cm measured at a height of 1 m above ground level andremoval of rubbish up to a distance of 50 m outside the periphery of the area cleared
DISMANTLING AND DEMOLISHING
Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking thematerial within 50 metres lead of :G.S. Sheet
Taking out existing CC interlocking paver blocks from footpath/ central verge,including removal of rubbish etc., disposal of unserviceable material to the dumpingground, for which payment shall be made separately and stacking of serviceablematerial within 50 metre lead as per direction of Engineer-in-Charge.
Dismantling steel work in built up sections in angles, tees, flats and channelsincluding all gusset plates,bolts, nuts, cutting rivets, welding etc. includingdismembering and stacking within 50 metres lead.
EARTH WORK EXCAVATION WORKS
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.Ordinary rock
Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed,within a lead of 50 m.Hard rock (blasting prohibited)
Extra for every additional lift 1.5 m or part there of in excavation / banking excavatedor stacked materials.All kinds of soil
Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
PCC work
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work above plinth level up to floor five level1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
RCC WORK
Providing and laying in position machine batched and machine mixed design mix M25 grade cement concrete for reinforced cement concrete work, using cement contentas per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard settingof concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge.All work upto plinth level.
Providing and laying in position machine batched and machine mixed design mix M25 grade cement concrete for reinforced cement concrete work, using cement contentas per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. .All work above plinth level upto floor V level
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treatedbars of grade Fe-500D or more
Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo - MechanicallyTreated bars of grade Fe-500D or more
Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (ZoneIII) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Providing anchor rods not less than 22mm dia for a depth not less than 1m in hardrock below footing in holes of 30mm diameter and grouting the holes with cementmortar 1:2 including cost conveyance of materials, labour charge etc: complete as perthe direction of engineer in charge.
FORM WORK
Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete
Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, etc. and removal of form for:Walls (anythickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers
Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, etc. and removal of form for:Stairs,(excluding landings ) except spiral - staircases)
Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide
Centering and shuttering including strutting, etc. and removal of form for:Weathershade, Chajjas, corbels etc., including edges
STONE WORKS
DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonrywith good quality blasted rubble including packing to compactness to lines and levelscost and conveyance of all materials labour charges etc. complete as per direction ofDepartmental officers at site
Random rubble masonry with hard stone in superstructure above plinth level and uptofloor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceilinglevel and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarsesand)
MASONRY WORKS
Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cmor nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cmor nearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cmor nearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) includingcost of scaffolding complete
PLASTERING
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
STEEL WORK
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainless steeldash fasteners, stainless steel bolts etc., of required size on the top of the floor or theside of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade,5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metreor as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/selftapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch inhorizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters andtrusses and including cutting to size and shape wherever required.
Designing, fabricating, testing, installing and fixing in position Curtain Wall withAluminium Composite Panel Cladding, with open grooves for linear as well ascurvilinear portions of the building , for all heights and all levels etc. including: a)Structural analysis & design and preparation of shop drawings for pressureequalisation or rain screen principle as required, proper drainage of water to make itwatertight including checking of all the structural and functional design. b) Providing,fabricating and supplying and fixing panels of aluminium composite panel cladding inpan shape in metalic colour of approved shades made out of 4mm thick aluminiumcomposite panel material consisting of 3mm thick FR grade mineral core sandwichedbetween two Alumini um sheets (each0.5mm thick). The aluminium composite panelcladding sheet shall be coil coated, with Kynar 500based PVDF / Lumiflon basedfluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts,washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets ofAluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serratedwashers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts ofapproved make in SS 316, Nylon separators to prevent bi-metallic contacts allcomplete required to perform as per specification and drawing The item includes costof all material & labour component, the cost of all mock ups at site, cost of allsamples of the individual components for testing in an approved laboratory, field testson the assembled working curtain wall with aluminium composite panel cladding,cleaning and protection of the curtain wall with aluminium composite panel claddingtill the handing over of the building for occupation. Base frame work for ACPcladding is payable under the relevant aluminium item.s The Contractor shall providecurtain wall with aluminium composite panel cladding, having all the performancecharacteristics all complete , as per the Architectural drawings, as per itemdescription, as specified, as per the approved shop drawings and as directed by theEngineer-in-Charge. However, for the purpose of payment, only the actual area on theexternal face of the curtain wall with Aluminum Composite Panel Cladding(including width of groove) shall be measured in sqm. up to two decimal places.
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
DOORS & WINDOWS
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I)decorative type, core of block board construction with frame of I st class hard woodand well matched teak 3 ply veneering with vertical grains or cross bands and faceveneers on both faces of shutters.35 mm thick Fixing with hinges of required size andnecessary screws(Note: Hinges and necessary screws hall be paid separately)
Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressedbutt hinges bright finished of required size with necessary screws. ( Shutter area to bemeasured)
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body,door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:200x10 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:100x10 mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:125 mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised(anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed torequired colour and shade, with necessary screws etc. complete.Twin rubber stopper
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pairof handles of approved quality for aluminium door, with necessary screws etccomplete as per direction of Engineer- in- charge.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frameshall be covered with fiber glass from all sides. M.S. stay shall be provided at thebottom to steady the frame.
Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand andmanufacture, made with fire - retardant grade unsaturated polyester resin, moulded to3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, castmonolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856,including fixing to frames.
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (costof glass excluded ) (overall area of door shutter to be measured):Rectangular orsquare
46 mm thick Steel Fire Check Door (Double/Single leaf) of 120 minutes Fire ratingconfirming to BS:476 Part-22 and IS:3614 Part-II. Door shutter are fabricated with0.8 mm thick galvanized steel sheet pressed formed to provide a 46 mm fully flushdouble skin panel lock with seam joint. The internal construction of panel specially design Honey comb structure with reinforcement at all around. The door frames aremade from 1.2 mm thick galvanized steel sheet pressed form of size 100 mm x 57mm
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paidfor separately), using good quality Anjili wood /jack wood
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/sqm) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates inaccordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm
Providing and fixing 12 mm thick frameless toughened glass door shutter of approvedbrand and manufacture, including providing and fixing top & bottom pivot& double acting hydraulic floor spring type fixing arrangement and makingnecessary holes etc. for fixing required door fittings, all complete as per direction ofEngineer-in-charge ( Door handle, lock and stopper etc to be paid separately)
Providing and fixing of glass door SS Patch Lock with out handle in toughened glassdoor including all necessary screws etc. complete.
Providing and fixing Steel S.S- 304 (D) Door Pull Both Side Handle of 12 inch, oneSet (2 Handles) ( best make of approved quality ) for Glass, Wooden or similar doorsincluding necessary cutting and making good etc. complete
Supplying and fixing rolling shutters of approved make, made of required size M.S.laths, interlocked together through their entire length and jointed together at the endby end locks, mounted on specially designed pipe shaft with brackets, side guides andarrangements for inside and outside locking with push and pull operation complete,including the cost of providing and fixing necessary 27.5 cm long wire springsmanufactured from high tensile steel wire of adequate strength conforming to IS:4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters
Extra for providing mechanical device chain and crank operation for operating rollingshuttersExceeding 10.00 sqm and upto 16.80 sqm in the area
ALUMINIUM WORKS
Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges /pivots and making provision for fixing of fittings wherever required including thecost of EPDM rubber/ neoprene gasket required (Fittings shall be paid forseparately)Powder coated aluminium (minimum thickness of powder coating 50micron)
Providing and fixing Brass100 mm mortice latch and lock with 6 levers without pairof handles ( best make of approved quality ) for aluminum doors including necessarycutting and making good etc. complete
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofEngineer - in- Charge.Pre- laminated particle board with decorative lamination onboth sides
Providing and fixing frosted film in the fixed glass etc. Complete as per the directionof departmental officers
Providing and fixing glazing in door, window, ventilator shutters and partitions etc.with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall bepaid in basic item): toughened glass of 6 mm thickness.
Providing and Fixing Aluminium Double U channel of required size for sliding doors
Providing and fixing to existing door frames24 mm thick factory made PVC doorshutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets ofsize 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1mm (± 0.1 mm) wall thickness. The lock rail made up of 'H'section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm)wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S.'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm(± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction ofEngineer-in-charge( For W.C. and bathroom door shutter).
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wallthickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. Thehinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hingesfixed to the frame complete as per manufacturer's specification and direction ofEngineer-in-chargeExtruded section profile size 48x40 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:100x10 mm
Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved stee primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
Providing and fixing factory made uPVC white colour sliding glazed window upto1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length(shape & size according to uPVC profile), appropriate dimension of uPVC extrudedglazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy(white powder coated) touch locks with hook, zinc alloy body with single nylonrollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixingframe to finished wall and necessary stainless steel screws etc. Profile of frame &sash shall be mitred cut and fusion welded at all corners, including drilling of holesfor fixing hardware's and drainage of water etc. After fixing frame the gap betweenframe and adjacent finished wall shall be filled with weather proof silicon sealentover backer rod of required size and of approved quality, all complete as per approveddrawing & direction of Engineer-in-Charge. (Single / double glass panes, wire meshand silicon sealent shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimensioni.e. in depth & width of profile shall be acceptable.Two track two panels slidingwindow made of (small series) frame 52 x 44 mm & sash 32 x 60 mm bothhaving wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriatedimension. (Area of window upto 1.75 sqm)
Providing and fixing factory made uPVC white colour sliding glazed window upto1.50 m in height dimension comprising of uPVC multi-chambered frame with in-builtroller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thickgalvanized mild steel section made from roll forming process of required length(shape & size according to uPVC profile), appropriate dimension of uPVC extrudedglazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy(white powder coated) touch locks with hook, zinc alloy body with single nylonrollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixingframe to finished wall and necessary stainless steel screws etc. Profile of frame &sash shall be mitred cut and fusion welded at all corners, including drilling of holesfor fixing hardware's and drainage of water etc. After fixing frame the gap betweenframe and adjacent finished wall shall be filled with weather proof silicon sealentover backer rod of required size and of approved quality, all complete as per approveddrawing & direction of Engineer-in-Charge. (Single / double glass panes, wire meshand silicon sealent shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimensioni.e. in depth & width of profile shall be acceptable.Two track two panels slidingwindow made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both havingwall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead ofappropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm).
Providing and fixing casement handle made of zinc alloyed (white powder coated) foruPVC casement window with necessary screws etc. complete.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness (weight not less than 10kg/sqm)
TILE WORKS
Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm infloors, jointed with neat cement slurry mixed with pigment to match the shade of thetiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar1:4 ( 1 cement : 4 coarse sand):Dark shade pigment using ordinary cement
Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
Providing and laying Vitrified tiles indifferent sizes (thickness to be specified bymanufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622,of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thickbed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint withwhite cement & matching pigments etc. complete.Size of Tile 600x600 mm
Extra for providing opening or required size & shape for wash basin/kitchen sink inkitchen platform, vanity counter and similar location in marble/granite/ stone work,including necessary holes for pillar taps etc. including moulding, rubbing andpolishing of cut edges etc. complete.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by themanufacturer), with water absorption less than 0.08% and conforming to IS : 15622,of approved brand & manufacturer,in all colours and shade, in skirting, riser ofsteps, laid with cement based high polymer modified quick set tile adhesive (waterbased) conforming to IS : 15477, in average 6 mm thickness, including grouting ofjoints (Payment for grouting of joints to be made separately).Size of Tile 600x600mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 600x600 mm
cement concrete work for screed concrete in buiding with the mix of :1:1.5:3( 1cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded andprepolished, machine cut for kitchen platforms, vanity counters, window sills, faciasand similar locations, of required size, approved shade, colour and texture laid over20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated withwhite cement, mixed with matching pigment, epoxy touch ups, including rubbing,curing, moulding and polishing to edges to give high gloss finish etc. complete at alllevels.Area of slab over 0.50 sqm
FALSE CEILING
Providing and fixing false ceiling at all height including providing and fixing of framework made of special sections, power pressed from M.S. sheets and galvanized withzinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting ofangle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mmdia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangersof 25x10x0.50 mm of required length with nuts & bolts of required size and other endof angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at thespacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thickbottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm,at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I.intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm longG.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mmhigh having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed towall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wallscrews @ 230 mm interval, including fixing of gypsum board to ceiling section andperimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c,including jointing and finishing to a flush finish of tapered and square edges of theboard with recommended jointing compound, jointing tapes, finishing with jointingcompound in 3 layers covering upto 150 mm on both sides of joint and two coats ofprimer suitable for board, all as per manufacturer's specification and also includingthe cost of making openings for light fittings, grills, diffusers, cutouts made withframe of perimeter channels suitably fixed, all complete as per drawings, specificationand direction of the Engineer in Charge but excluding the cost of painting with:12.5mm thick tapered edge gypsum moisture resistant board
Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm intrue horizontal level, suspended on inter locking metal grid of hot dipped galvanizedsteel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting ofmain "T" runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to centerand cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mmlong spaced between main "T" at 600 mm center to center to form a grid of 1200x600mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mmthick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceilingtiles of approved texture in the grid including, required cutting/making, opening forservices like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T"runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as perspecifications, drawings and as directed by Engineer -in-charge.12.5 mm thick fullyPerforated Gypsum Board tile made from plaster board having glass fibre conformingto IS: 2095 Part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mmc/c with centre borders of 48 mm and the side borders of 30 mm, backed with nonwoven tissue on the back side , having as NRC ( Noise Reduction Co efficient) of0.79, with 50 mm resin bonded glass wool backing.
MODULAR OT
Providing and fixing 2 mm anti static seamless conductive Epoxy Flooring (Primer,Screed, ESD Carbonized Coating, Self-leveling Mix Carbonized compound and finalcoating) for Clean room. The floor should be scratch resistant, fire resistant, chemicalresistant, non-corrosive, slip resistant, smooth, anti-fungi, antimicrobial imperviousmaterial conductive enough to dissipate static electricity but not conductive enough toendanger personnel from electric shock. The floor finish should pass over a concealedcove former and continue up the wall for 100mm. The floor should be provided flat towithin a tolerance of ±3mm over any 3-meter area. Copper grounding strip (0.05thick, 50 mm width) should be laid flat on the floor in the conductive adhesive andconnect to copper wire of grounding. The connection from copper grid should bebrought out uniformly at places to form equipotential grid. A self-leveling compoundshould be laid prior to lying of the floor finish. One earthing lead should be broughtout of from every 150 Sq.ft. area and attaching it to main earthing strip/ground. Finished Floor should be highlydurable with resistance to shock, scratch proof and indentation. Corners should beuniformly Coved Up to 10 cm height. The conductive material should be uniformlyimpregnated as grains. The floor should be inert to body fluids, chemicals, detergentsand disinfectants and it should not be affected by temperature variation within theOT. Colour should be uniform, pleasant and matching with ambiance. The floorshould have electrical resistance (Point to ground) within 2.5x10 to 2.5x106 Ohms asper NFPA-99/ DIN 51953/ATMF-150 B1 class of fire resistance. The floor shouldefficiently discharge electric charges up to 2 KV. The floor should not allow build-upof electrical charge beyond 100 volts due to anti static effect. It should fulfill productrequirements as per EN649. The corner should not be terminated sharply andconcealed cove-former (Aluminium) should be used overlap to a height ofapproximate and sealed perfectly and uniformly. Self-leveling compounds should beused for this purpose.
Providing, Fixing, Installation, and Commissioning of Automatic HermeticallySealing door 1.2 to 1.8m wide, 2.1 to 2.3m height, having high pressure laminate on both sides that could withstand high abrasion, vision panels (300x500mm). Highgrade aluminium extrusion profile to carry any door weight (till size 2400mm inwidth X 2400mm in height) with deep indentations to ensure perfect hermetic sealing.The door leaf should have high quality synthetic rubber gasket with long life toensure hermetic sealing to maintain pressure differential. Air tightness 99.99% at apressure 100KPa (Test certificate for hermetic sealing with door frame should beprovided with pre-despatch documents. The finished door on either side of the doorshould be perfectly level (maximum permissible difference +1mm). P Door core of60mm thick built up with 4mm thick HPCL (High Pressure Compact Laminate) skinat both side of the door to provide better strength and rigidity. CFC-free, high densitypolyurethane puff (density 40 kg/m3), thickness 52mm to provide better insulation.Door core is surrounded by 2.5 mm thick high-grade aluminium extrusion profileswith natural anodizing of 15 microns finish. Epoxy Polyester Powder coated as perRAL colours or SS Finish (matt/ mirror finish) The aero- dynamic design of profilesmakes the door ROBUST in its segment league. Gaskets Door blade is made with 3tier specially designed 3 side heavy duty replaceable EPDM gasket against wallframe. Bottom sealing with 2-tier heavy duty EPDM gasket to flush with finishedfloor. Stainless Steel 304 grade lever handle on both side of the door blade for smoothand easy door opening and closing. High Quality double glazed flush vision windowof Wall Frame High Grade Aluminium extrusion with natural anodized 15-micronfinish wall frame profile. This wall frame profile is 3-sided blind fixed with claddingon wall cut-out section from inside and outside of the room. Including Labour,Transportation, Conveyance etc. The door interlock and access control system shallbe provided with combination of proximity card based, numerical key pad lock basedand push button-based system & foot operating system. The system shall becomplete with access logic controllers, door electromagnets, door release footoperating push button, touchless sensor opening & Closure, emergency doorrelease buttons, PC communicator, control and power wiring and cabling and otherrequired accessories, hardware and software. The access control system shall bepowered through UPS supply for uninterrupted operation even during mains powerfailure. The door Electromagnetic Lock shall be suitable for installation ondoors/frames. The electromagnetic lock and armature shall be constructed anddesigned to provide trouble free service. MAKE: METAFLEX/REBBONE/ALTOSor Equivalent
Supply Installation Testing & Commissioning (SITC) of Wall panels made up of GIpowder coated of 0.4 mm thick sheet on both sides, with 50 mm thick class 'O' PUFof min.38kg/m3 density sandwitched in between. The GI sheet shall have 80 micronthick powder coating by hot dip galvanizing with zinc coating not less than180gm/sqm both side of the panel. Scope includes bottom runner, inter connectingprofiles, fixingarrangements, silicon sealant application and all other accessories required tocomplete the work as per site requirement. Colour: Powder coated, complete with allnecessary hardware, accessories, fittings and fixtures, as per description in individualitems, technical specifications, drawings and instructions of the EngineerInchargeSelf-supporting wall provided in modular units consisting of external skin in PCGI/PCGI which will be 0.4mm thick ,with protective film to prevent surface damageduring shipping and installation. Movable Wall Includes a) Puff Instulation 40kg/m³b) GI frame work c) Silicon Sealant (Clear/White/Winsil Gray) Note: Necessary cutopens to be made for service outlets and finished after passing the service outlets,nothing extra will be paid on this account.
Supply Installation Testing & Commissioning (SITC) of modular false ceilingwith powder coated Galvanized Iron of 0.4 mm thick sheet on both sides, 50 mmthick class 'O' PUF of min.38kg/m3 density sandwiched in between. Thesurface shall be coated with 80-micron thick powder coating by hot dip galvanizingwith zinc coating not less than 180gm/sqm both side of the panel. Scope includesrunner, covings, interconnecting profiles, fixing arrangements, silicon sealantapplication and all other accessories required to complete the work as per siterequirement. Internal GI framework if necessary for support, Silicon Sealant(Clear/White/Winsel Gray), complete with all necessary hardware, accessories,fittings and fixtures, as per description in individual items, technical specifications,drawings and instructions of the Engineer-In charge.
Pass Box shall be provided at required locations for transfer of samples, chemicalsand materials into the laboratory Pass box with UV to be provided. The Pass Boxshall be constructed in 18 swg SS 304. The corners inside the Pass Box chamber shallbe coved for easy cleaning. The pass box chamber dimension shall be approximately610 mm x 610 mm x 610 mm. The unit shall be complete with HEPA filters, blower,motor, door electromagnets, door interlock, UV Lamp with timer, necessary wiring,controls and all other accessories. Etc. complete.
MULTIWOOD WORKS
Providing and fixing Thomson Multi wood board or equivalent make, in shelves withscrews and fittings wherever required, edges to be painted with polyurethane primer(fittings to be paid separately) as per the direction of site Engineer-in-charge.
Providing and fixing concealed hinge of approved quality for 19-20mm thick doorwith stainless steel screws complete :
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:75 mm
Providing and fixing magnetic catcher of approved quality in cupboard/ward robe shutters, including fixing with necessary screws etc. complete.Triple strip verticaltype
providing and fixing powder coated telescopic drawer channels 300 mm long withnecessary screws etc. complete as per directions of Engineer -in-charge.
Providing and fixing special quality bright finished brass cupboard or ward robe lockswith four levers of approved quality including necessary screws etc. complete.40 mm
CURTAIN WORKS
Supplying and laying polyester, washable and stain free cloth(Bio-Active fabricwashable germ free suitable for sterile area) curtain curtain system with maximumcurtain curtain cloth height 230 cm(top 30 cm white colour net and 200cm light bluecolor as per approval) stitching with stifiner tape, pleats, ironing and laying aroundeach bed using PVC runner with hooks & stopper for hanging/sliding etc. as perthe direction of engineer in charge including conveyance to site, laying in line andlevel, sealing all cutting in false ceiling with powder coated MS cup, all leads and liftsincluding all labour charges etc. complete. (unpleated length of the clothmeasurement will be considered for payment also the bottom and top foldings will notbe considered in cloth measurement)/ supplying and fixing powder coated 20mm dia.GI round tube hanging support of required length(app. length 1.10m) one end fixingfrom slab by using 6mm dia expansion bolt at a distance not more than 2m, c/c downend fixed to powder coated aluminium channel frame 45 x 20mm x 1mm thicksection by using SS screw as per the direction of engineer in charge includingconveyance.
Providing and fixing of vertical/roller blinds width 100 mm regular quantity madefrom 100 % polyster/Fibre yarn coated with fade resistant polymer to ensure completeopaquety with zero light transmittance, having suitable coating on exterior, includingall fixtures and fittings complete in all respect as per design and instruction of Engineer in-charge and as per site conditions. The colour will be approved by thecompetent authority.<br> and inclusive of all labour charges.
PAINTING
Providing and applying plaster of paris putty of 2 mm thickness over plastered surfaceto prepare the surface even and smooth complete.
Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Two or more coats applied on walls @1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10sqm
Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Painting Steel work with Deluxe MultiSurface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqmover an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand andmanufacture
Providing and applying white cement based putty of average thickness 1 mm, ofapproved brand and manufacturer, over the plastered wall surface to prepare thesurface even and smooth complete.
Melamine polishing of approved brand and manufacture on wood work ( one or morecoat).
Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work
Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. Thecrystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of theengineerincharge. The product performance shall carry guarantee for 10 years against anyleakage.For vertical surface two coats @0.70 kg per sqm
Providing and laying water proofing treatment in sunken portion of WCs, bathroometc., by applying cement slurry mixed with water proofing cement compoundconsisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed withwater proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to aircure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed withwater proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to aircure for 4 hours followed with water curing for 48 hours. The rate includespreparation of surface, treatment and sealing of all joints, corners, junctions of pipesand masonry with polymer mixed slurry.
Providing and laying water proofing treatment on roofs of slabs by applying cementslurry mixed with water proofing cement compound consisting of applying : a) aftersurface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with waterproofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass clothwhen the first layer is still green. Overlaps of joints of fibre cloth should not be lessthan 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarsesand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by watercuring for 48 hours. The entire treatment will be taken upto 30 cm on parapet walland tucked into groove in parapet all around. d) fourth and final layer of brick tillingwith cement mortar (which will be paid for separately. For the purpose ofmeasurement the entire treated surface will be measured)
PLUMBING AND SANITARY FITTINGS
Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, includingflush pipe, with manually controlled device (handle lever), conforming to IS : 7231,with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approvedquality) complete with 6 mm thick hard board ground fixed to wooden cleats withC.P. brass screws and washers complete.
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approvedquality and colour.Waste coupling 31 mm dia of 79 mm length and 62 mm breadth weighing not less than 45 gms
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleatswith CP brass screws with concealed fitting arrangement of approved quality andcolour450 mm long towel rail with total length of 495 mm, 78 mm wide and effectiveheight of 88 mm. weighing not less than 170 gms
Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make )including cost of materials and labour charges etc complete as per the direction of siteEngineer-in-charge.
Providing and fixing C.P brass long nose bib cock of approved quality conforming toIS standards and weighing not less than 810 gms.15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure,with plastic floats complete:20 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
Providing and fixing PTMT grating of approved quality and colour.Circular type100 mm nominal dia
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chase sand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.15 mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.20 mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.32 mm nominal dia pipes
Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing PTMT extension nipple for water thank pipe, fittings ofapproved quality and colour .20 mm nominal bore, weighing not less than 40 gms
Constructing soak pit 1.20x1.20 m filled with brickbats including S.W. drain pipe 100mm diameter and 1.20 m long complete as per standard design.
Providing and fixing of wall mounted foot operated 2 way handwash sink with backsplash (S.S 304 grade top 1.5mm thick and covering 1mm), of overall size 1500mm,600mm, 950(+500) mm. The rate includes material, carriage, shifting up to 5th floor,placing, labour charges, etc., except tap. the placement as per the direction ofengineer in-charge.
Providing and fixing C.P. brass pillar taps with elbow operated levers ISI marked, 15mm nominal bore.
Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 38 mmsingle piece moulded with height of 270 mm, effective length of tail pipe 260 mmfrom the center of the waste coupling, 77 mm breadth with 25 mm minimum waterseal, weighing not less than 263 gms
Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings including fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes & fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer -in-Charge. Internal work - Exposed on wall15mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings including fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes & fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings including fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes & fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32mm nominal dia pipes
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Surgeontype wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers
Constructing R.C.C manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) withR.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick withcement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neatcement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size ) finished with a floating coat of neatcement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg( weight of cover 58 kg and weight of frame 58 kg):
Flexible (coil shaped) PVC waste pipe for sink and wash basin 40 mm dia with length not less than 700 mm i/c PVC waste fittings.
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00spacing. This includes jointing of pipes & fittings with one step PVC solvent cementand testing of joints complete as per direction of Engineer-in-Charge Concealedwork, including cutting chases and making good the wall etc. 15 mm pipe 10kgf/cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe10Kgf/cm2
Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of joints complete as per directionof Engineer in Charge. 50 mm dia 10Kgf/cm2
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Angleback wash basin size 600x480 mm with single 15 mm C.P. brass pillar tap
Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of Joints complete as per directionof engineer in charge.110 mm dia 6Kgf/cm2
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement-110 mm dia Door Elbow
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Elbow
Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 110 mm dia 6Kgf/cm2 - External work- Exposed on wall
Providing and fixing PVC pipes includings jointing of pipes with one step pvc solventcement, trenching , refilling & testing of joints complete as per direction ofEngineer in Charge. 150 mm dia 6 Kgf/cm2
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 110 mm dia Bend
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipesincluding jointing with PVC solvent cement 110x110x110 mm dia Tee
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110x110x110 mm dia Door tee
Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes,including jointing with PVC solvent cement -110 mm dia Vent cowl
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 110 mm dia Door Bend
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 110 mm Dia Y
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 150 mm Dia Y
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 150 mm Vent cowl
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 150 mm dia Door Tee
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 150 mm dia Tee
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 150 mm dia Elbow
Providing and fixing PPR Unions- PPR Union 150mm
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 150 mm dia Bend
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 150 mm dia Door Bend
Providing and fixing PPR Unions- PPR Union 110mm
SIGNAGES
Design, providing and fixing Digital Printed vinyl signage boards with transparent3mm acrylic Sheet with 4 nos. SS Studs with lettering of size 15x45 cm. Complete asper the per the direction of Engineer in charge. <br>
NAME BOARD ACP SHEET WITH MULTIWOOD LETTERING : Design,Supplying andfixing Name Board as per the technical specifications given -1 Inch GI pipe frame(16Guage) for Frame (Sizeproportional), Primer Paint & Black Painted Pipes for Frame.,5mm ACP sheets(Aluminum Composite Panel)for Box area, 18mm thick Multi wood Lettering for Name Board as approvedby<br> Engineer incharge.<br>For Measurement purpose, only area of ACP sheet to be measured
BUILDING PERMIT
Preparation of civil drawings, submission of drawings toLSGD/Municipality/Corporation/ concerned authority and obtaining approval for thesame, complete excluding the Departmental Fee for the Permission and Ownershipetc. Any statutory payment obligation shall be the sole responsibility of the client.
ELECTRICAL
POINT WIRING
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point
CIRCUIT WIRING
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire
Supply and clamping of 20mm dia corrugated pvc flexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required.
SWITCH , SOCKET AND METAL BOXES
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
DB,ENCLOSURE AND ITS ACCESSORIES
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) anchor bo
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overcurrent protection (RCBO), having a sensitivity current upto 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A-40A, 4P, 100mA
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overcurrent protection (RCBO), having a sensitivity current upto 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A, 4P, 100mA
Supplying and fixing 40A / 63A, TP MCB, 415 Volts, "C" curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing FP CRCA sheet steel enclosure with provision to mount MCB/Isolator/RCCB/RCBO and other modular devices on surface/ recess complete with connections, testing and commissioning etc. as required.
Supply, installation, testing and commissioning of SMC FRP rectangular junction Box (200 x 140 x 95mm) of approved make with MCB rail suitable for providing connection for fixing four pole isolator as per the direction of Engineer in charge. (Make: Sintex)
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 40A DP Isolator complete with connections, testing and commissioning etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps DP Isolator complete with connections, testing and commissioning etc. as required.
PANELS
Main Panel:-Supply, Installation, Testing and Commissioning of 415 V 50Hz LT Switch board OEM Design Verified Assembly Panel complying to IEC 61439 Part 1 & 2.The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type , Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition),cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer: - a) 1 Nos 200 A 36 kA 4P MCCB EDO MP based with 3O/C 1E/Releases & S/T O/V relay with CT at neutral earthing conductor b) 1 Set RYB Indication Lamp with control fuses and switches c) 1 no. Multi-function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring V,A,F,KW,KVA,PF,THD d) 1 no. of Under Voltage/Over Voltage Relay. e) 1 no. Class B & Class C/ Class 1 & Class 2 Surge arrestor device with necessary HRC fuse for protection of same. Outgoings: - a) 1 No 100 A, 26 kA, TPN MCCB, TM based b) 5 No 63 A, 25 kA, TPN MCCB, TM based c) 1 Nos 40 A 25 kA TPN, MCCB, TM based d) 1 Nos 25 A 25 kA TPN, MCCB, TM based e) 1 No 160A TPN, Isolator f) ON-OFF-TRIP Lamps with 2A fuse -8 sets g) Surge Protection Devices for Main Panel: Type 1-2 sets, 320 A 415V,50kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. All Breakers in the incoming side shall be with LSIG protection and all the breakers in the outgoing side shall be with LSI protection. ON/OFF/TRIP indicators shall be provided for all the breakers (incoming & outgoing). Necessary spreader terminals, extended ROH, phase barriers, shrouding etc shall be as per the rules. Details as shown in SLD.
CABLE SUPPLY AND LAYING
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench120/102.5 mm or nearest size
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 240 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 4 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. platewith inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60cm long and fixing the same in ground as required.
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
CABLE TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.4 X 16 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 6 sq. mm (22mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 4 sq. mm (22mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
CABLE TRAY
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 450 mm width X50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 225 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 225 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness
EARTHING PROTECTION
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt) as required
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt& spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
LIGHT AND FAN FIXTURES
SITC of 2x 2 LED Recess mounted 36W light fixture, system efficacy >120 lm/W and system lumen output not less than 3600 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 4 KV internal surge protection with electronic drive system, power factor >/=0.95, THD<10%, rated life of 50,000 hours at L70 with a CRI > 80, UGR <19, SDCM<5 and CCT in between 4000K to 5700K.Luminaire shall be flicker free with ripple factor < 5%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make.
SITC of 4 feet surface/suspended mounted LED batten type luminaire with a powerconsumption not more than 20 W, luminaire lumen output of 2200 lumens, luminaire efficacy > 110 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall have a sleek design with extruded aluminium section, white CRCA housing with optically efficient poly carbonate diffuser to provide uniform illumination and wider light distribution. The luminaire shall have a CCT of 4000K/6500 K, CRI > 80, power factor >0.95, SDCM < 5, THD <10%. The luminaire shall be EMI/ EMC compliant and shall have an internal surge protection of 3 kV with 50,000 burning hours as per L70B50 criteria. The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs.
SITC of 2 feet surface/suspended mounted LED batten type luminaire with a power consumption not more than 10 W, luminaire lumen output of 1100 lumens, luminaire efficacy > 110 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall have a sleek design with extruded aluminum section, white CRCA housing with optically efficient poly carbonate diffuser to provide uniform illumination and wider light distribution. The luminaire shall have a CCT of 4000K /6500 K, CRI > 80, power factor >0.95, SDCM < 5, THD <10%. The luminaire shall be EMI/ EMC compliant and shall have an internal surge protection of 3 kV with 50,000 burning hours as per L70B50 criteria. The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature, including all accessories necessary as required to complete installation.
SITC of 10W LED BULKHEAD LIGHT fixture , System efficacy>=100 lm/W and system lumen output not less than 1000 lm. , driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor >0.95, THD<10%, rated life of 50,000 hours at L70 with a CRI > 80, SDCM<5 and CCT in between 4000K to 5700K. ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make
Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Supplying and fixing of required length 32 mm dia G.I. Pipe (light class) including painting etc. as required.
Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required:
SITC of 250mm sweep Exhaust Fan, 900rpm light duty exhaust fan shutter type white colour, 9" or 10" star rated as per BEE, with its all accessories including mounting as required for complete installation.
SITC of Exhaust Fan Celling mounted type with flexible horse of required length and vent cowl as bird net, Make similar to Luker LXC 200mm 21W 1050RPM Tubular Ventilating Ceiling Mounted Fan or equivalent with its all accessories including mounting accessories.
SITC of 450mm sweep Wall fan having speed control, oscillation control at bottom as suitable for operation on single phase 230 volt AC supply complete with continuous duty motor and all accessories including mounting as required for complete installation.
FAN CLAMP
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Supply installation, testing and commissioning of 20 kVA three phase to three phase UPS, The UPS shall comply with rated input voltage of 415V +/- 15%, 50Hz +/ 10%, 3Ph, PF 0.95; output with 415V, 3Ph, 50 Hz. The UPS system shall have unity output power factor (kW = kVA) shall ensure Ripple factor shall be </=3%, THD <5% or as per latest Indian / International standards. The UPS shall work on 16 bit microprocessor Architecture, communication ports, monitoring software, O/L,.SC, E/F protections self diagnostic features, back feed protection, phase sequence correction self diagnostic features, LCD / LED display panel for functions all parameters etc. Convertors, Invertors. Battery Charger shall utilize PWM technology with IGBT for both rectifier. The UPS system shall be provided with 30 minutes back up time on the full load (20kVA) with required no. of SMF Battery (VRLA type) with battery management system, housed in suitable cabinet / stand. The UPS shall have static bypass, maintenance bypass, complete with Internal wiring, interconnection cabling and all required accessories to be provided. The efficiency of UPS shall be >/=95% or more. The UPS battery system combined have to comply with all required safety standards IS / IEC standards. The UPS system shall have sleep mode operations for energy saving and future Li-ion battery compatible. The UPS shall be suitable for Hospital application.
SAFETY MEASURES
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supply & fixing Laminated drawings of electrical layout, schematic drawing etc. with teakwood frame work on wall as approved by the directorate of electricity
Supply and fixing of Shock treatment chart duly mounted on a wooden frame with glass on front as required in 2 languages (Hindi & English).
Providing & fixing in position 1000 mm wide , Elastomeric Insulating Mats as per IS 15652:2006, 2.0mm thick, suitable upto 3.3kva(Class A) , fire retardant,no effect of acids, alkalies and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top)
PUMP SET
SITC of 5 HP Pure Copper Winding Domestic/ Industrial Three Phase Self Priming Monoblock Pump Discharge Range minimum 12 lps @ 16m Head as per the direction of Electrical Engineer in charge
S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor
Supply, Installation, testing and commission, of De-Watering submersible pump including solenoid valves, level switches, control wires etc. The price shall inclusive of all connected electrical work. Capacity 144lpm at 6Mtrs. head, three phase electric motor, 380-440V, AC Supply
OT ELECTRIFICATION WORKS
Supply, installation, testing and commissioning of 10 kVA, three-phase input to single-phase output online UPS, suitable for hospital application. The UPS shall operate on rated input voltage 415 V ±15%, 50 Hz ±10%, 3-phase, power factor 0.95. The output shall be 230 V ±1%, single phase, 50 Hz. ripple factor <=3%, output THD < 5% or as per latest Indian / International standards. The UPS shall be based on 16-bit microprocessor architecture, complete with communication ports, monitoring software, overload, short-circuit and earth fault protections, self-diagnostic features, back-feed protection, phase-sequence correction, and LCD / LED display panel for all operating parameters. The UPS shall be provided with IGBT-based PWM rectifier and inverter, and an IGBT-based PWM battery charger The efficiency of UPS shall be >/=95% or more. The system shall include static bypass and maintenance bypass, complete with all internal wiring, interconnection cabling and accessories
SITC of recessed 36 W LED peripheral light fitting, size 600 × 600 mm, with optical anti-glare system for adjustable light distribution, suitable for clean room applications. Luminaire shall have UGR < 19, CRI > 80, IP65 protection from front, and shall operate within ambient temperature 0°C to 45°C. LED life shall be 50,000 hours @ L70. CCT 4500-5700K ,Electrical characteristics: THD < 10%, power factor > 0.9, surge protection minimum 2 kV, complete with pre wired electronic driver. Luminaire efficacy shall be greater than 110 lm/W. Luminaire cover shall be made of stainless steel. The item shall include all accessories, hardware, wiring, and fixing arrangements necessary to complete the installation as per specifications and drawings.
SITC of 10KVA Isolation Panel System, should have isolators provided through leakage relays with EN/CE/UL/BIS/FDA/IEC certification. Specification fault detection feature,medical grade Isolation, compact and mountable on wall.
DOCUMENTATION AND APPROVAL
DOCUMENTATION AND APPROVAL "Charges for Preparation of all drawings submitting and getting approval from Electrical Inspectorate, submitting of Completion certificates and arranging inspection, getting sanction and energization certificates from Electrical Inspectorate & KSEB, obtaining power allocation & power connection etc. including feasibility study. for commissioning of the whole installation. All statutory payments will be reimbursed on production of the original receipts. (for modification works
OPERATION THEATRE - HVAC
Supply, installation, testing, and commissioning of 11.0TR - 4400 CFM, 100mm E.S.P, DX type recirculating factory-built AHUs with 2-stage filtration, 6-row DX cooling coil, double-skin AHU made of 50 mm thick panels consisting of 0.8 mm thick pre-coated GSS on outside, 0.8 mm thick Aluminum sheet inside with factory injected PUF with a minimum density of 40 kg/m³. The AHU shall be ceiling- or floor-mounted type, single- or double-deck (as per site conditions) along with thermal-break aluminum extruded profile at corners and joints, complete with plug fan compatible with VFD as specified in the starter panel, suitable IE3 class (per IS 12615) TEFC drive motor with IP55 protection suited for 415 ± 10% volts, 50 Hz, 3 phase AC supply, minimum two-bend GSS/PVC eliminators, cooling coil section with aluminum-finned copper tubes, filter section with 50 mm thick metal viscous/washable synthetic-type air pre- and fine filters (MERV 8 and MERV 14), mixing box, aluminum VCDs on fresh air, return air, and supply air openings, drain connection, 18 G stainless steel 304 with 19 mm NBR-insulated drain pan, necessary vibration isolation arrangement, expansion valve, drier, DX AHU kit, corded remote controller, limit switches for access doors, inspection lamp. UV-C emitters equipped with reflectors to be mounted on the coil surface using removable extruded aluminum frames. The UV-C emitters to be UL certified and capable of producing minimum 254 nm wavelength radiation, 7.5 W/sqft of coil surface area for equal distribution. Heaters (capacity to be proposed by OEM) to be slip-in type tubular heater with step controller to be fitted inside AHU with suitable humidistat, thermostat, air stat/airflow switch, and safety thermostat. Heaters to be arranged in two independently operating banks. One bank shall be operated through humidistat and one bank through thermostat. All the necessary incoming power and control cabling, earthing between AHU/strip heaters and control panel, all supporting GI hangers, MS angles, channels, nuts, bolts, washers, and other necessary items for unit installation shall be included in the scope of supply. Fans shall be Eurovent/AMCA-certified. AHUs shall be Eurovent/AHRI-certified..
Supply, installation, testing, and commissioning of 11.0 TR capacity air-cooled inverter-type outdoor condensing unit with a single- or multi-scroll compressor, as per specifications, complete with a drive motor of suitable capacity, air-cooled condenser with all accessories, hermetically sealed scroll compressor, electronicmicroprocessor-based panel controller with digital display, first charge of R32/R410A/R407C/R134a refrigerant gas, vibration isolation pads, and safety devices including thermal protector, pressure relief valve, overload relays, single phase preventer, high/low-pressure cutout, suitable for a three-phase 440V supply..
Supply, Installation, Testing, and Commissioning of Unidirectional Laminar Air Flow (LAF) plenum, size 2400 x 1800 mm (8 ft x 6 ft), constructed from 1.2 mm thick SS 304 sheet with a provision/cutout for mounting a swivel light set. The plenum shall be equipped with H14 terminal HEPA filters, tested in accordance with EN 1822, with a minimum efficiency of 99.995% at the most penetrating particle size (MPPS). A perforated, tablet-type stainless steel grill cover shall be provided on the bottom, fabricated from SS 304 with a minimum sheet thickness of 1.0 mm. The cover shall be easily removable as required. The plenum shall include a differential pressure port for measuring the pressure drop across the HEPA filters. The HEPA filter casing shall be aluminum, the media shall be microfiber glass paper, and the bonding shall use PU resin. The fins shall be aluminum, blended type. A polyethylene gasket shall be provided. The pressure drop shall not exceed 25 mm WC. The suspended laminar airflow (LAF) system shall provide Class 100 (ISO Class 5) clean air, as defined by ISO 14644-1.
Supply, installation, testing, and commissioning of suitably sized hard drawn copper refrigerant piping (both suction and liquid) including 19mm thick closed cellelastomeric insulation between indoor and outdoor units as per site conditions.Insulation shall be finished with 7 mils of factory laminated fibreglass cloth..
Supply, installation, testing, and commissioning of control/transmission wiring between indoor unit and outdoor unit. Cable must be routed through PVC conduits. Cable sizing shall be as per OEM recommendation..
Supply, storage, installation, testing, and commissioning of 22G (0.8 mm) aluminium ductwork in operation theatres of the specified gauge as appropriate, with all accessories, supports, jointing materials, and flanges, complete; all in accordance with SMACNA standards, the specifications, and drawings. The system shall be complete in all respects for commissioning..
Supply, storage, installation, testing, and commissioning of 20G (1.0 mm) aluminium ductwork in operation theatres of the specified gauge, with all accessories, supports, jointing materials, and flanges, complete; all in accordance with SMACNA standards, the specifications, and drawings. The system shall be complete in all respects for commissioning.
Supply, installation, testing, and commissioning of 32mm dia rigid UPVC condensate drain piping duly insulated with 9 mm thick closed-cell nitrile finished with 7 mils factory-laminated glass cloth, along with necessary U-trap, clamps, fittings such as bends, tees, and other necessary fittings, adequately supported as per site requirements, conforming to tender specifications..
Supply, installation, fixing, and hanging of factory-fabricated fire-retardant flexible canvas connection of minimum 150 mm width at the outlet of each ducted indoor unit with a zipper to facilitate temperature measurement. The fabric shall be made of polyester cloth with black PVC coating on both sides and a galvanized steel seam..
Supply, installation, testing, and commissioning of aluminium volume control dampers, complete with neoprene rubber gaskets, nuts, bolts, screws, linkages, and flanges, in accordance with the specifications and drawings..
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class ""O"") insulation on existing duct afterapplying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.Nitrille rubber insulation - 25 mm
Supply and installation of 25mm thick closed-cell Nitrile rubber insulation with FACTORY-laminated / pre-covered reinforced glass cloth on one side. The insulation shall be installed on existing ducts following the application of two coats of cold setting adhesive, ensuring proper adhesion and coverage. The insulation material shall have a density range of 40-60 kg/m³ and a thermal conductivity not exceeding 0.035 W/(m·K). All joints and breaks in the insulation shall be securely sealed with glass cloth tape.
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Fire damper
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Actuator
Supply and installation of fresh air/exhaust air louver constructed from powder coated aluminium with bird screen as per the specifications and drawings..
Supply, fabrication, and installation of return air module (nominal size 22 × 14 inches, or sized as per project design and approved by Engineer-in-Charge) with a 10 micron washable prefilter (MERV 7) and a stainless steel grade 304 grille with a thickness of 1.0 mm and a perforated design (3 – 5 mm holes, 50–70% open area). The module shall include a cowl or flanged connection with EPDM gaskets to ensure airtight integration with the existing return riser duct. The grille and filter shall be removable via hinged or panel access for maintenance and cleaning..
Supply and installation of OT/clean room parameter monitoring system equipped with a touch screen display for the following parameters: room temperature, relative humidity, and differential pressure. The supplied instrument shall be complete with all necessary high-precision sensors, pressure transmission piping, flush-mounted stainless steel enclosures, and other mounting accessories as required..
OT Validation - Validation of all operating theatres (OTs) as per relevant ISO 14644 standards, post-commissioning by performing the following tests using calibrated instruments : a. Temperature and humidity check b. Air particulate count c. Air change rate calculation d. Air velocity measurement at the face of terminal HEPA filtration d. Pressure differential levels relative to ambient/adjoining areas e. HEPA Filter Validation.
Supply and installation of under-deck insulation with 13 mm thick fire-retardant Class 0 nitrile rubber, density 40-60 kg/m³, bonded with manufacturer-recommended synthetic adhesive, and held in position with galvanized steel screws, washers, and cross-braced with 20 SWG galvanized steel wire netting..
Supply and application of two coats of a vapor barrier coating (Foster painting) on exposed ducts / copper refrigerant pipelines, as per the Engineer-in-Charge’s directions. The work includes surface preparation, application of the vapor barrier coating, and related works to ensure complete coverage and protection..
Supply Installation Testing and Commissioning of Condensate Drain Pump, with the following parameters - Max. flow 550L/h @ 0 head, Max. rec. head 5m. Single Phase Supply . All inclusive of accessories, wiring etc. necessary for fixing of the unit
EXHAUST SYSTEM
Supply, installation, testing, and commissioning of cabinet fan (EXHAUST AIR) 3000CFM @ minimum 25mm static pressure. The casing shall be sinlge-skin and constructed from galvanized steel. The fan shall be AMCA-certified for both air performance and sound performance. Installation/quoted price shall be all inclusive of electronic speed regulator for single- phase fans if applicable, along with necessary power and control wiring connecting the power supply and fan, suitable enclosure,mounting brackets etc. including all necessary accessories as per site conditions..
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
Supply and installation of Fresh Air/ Exhaust Air Louvre of aluminium powder coated with bird Screen as per specifications and drawings.
Supplying & fixing of powder coated extruded aluminum Return Air Grills with louvers but without volume control dampers complete as required.
FIRE FIGHTING
PIPES AND ACCESSORIES
Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:25 mm dia
Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:32 mm dia
Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:40 mm dia
Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:50 mm dia
Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitableclamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:65mm dia
Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:80mm dia
Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:100mm dia
SPRINKLERS
Providing,fixing, testing and commissioning of 15 mm dia quatzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent Sprinkler
Supplying, installation, testing & commissioning of sprinkler flexiblepipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1000 mm
Providing, installation, testing and commissioning of adjustable rosette plate for 15 mm dia in white finish UL listed or FM approved complete as required:
COPPER PIPING
12mm OD X .7mm THICK Cu PIPE - SITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, non- arsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and conforming to EN13348:2008.The pipes should also be accompanied with manufacturers test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor.
15mm OD X .9mm THICK Cu PIPE - SITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, non- arsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and conforming to EN13348:2008.The pipes should also be accompanied with manufacturers test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor.
22mm OD X .9mm THICK Cu PIPE - SITC of copper pipes manufactured fromphosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP),manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry,clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, non- arsenical, half hard,tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and conforming to EN13348:2008.The pipes should also be accompanied with manufacturers test certificate for the physical and chemical composition.Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code formedical gas system is also under the scope of contractor.
28mm OD X .9mm THIICK Cu PIPE - SITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, non- arsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and conforming to EN13348:2008.The pipes should also be accompanied with manufacturers test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor.
VALVES
12 mm BALL VALVE (MGPS) - SITC of Line Valves for use in plant rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 90º turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards.
15 mm BALL VALVE (MGPS) - SITC of Line Valves for use in plant rooms and tofacilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 90º turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards.
22 mm BALL VALVE (MGPS) - SITC of Line Valves for use in plant rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 90º turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards.
28 mm Ball valve (MGPS) - SITC of Line Valves for use in plant rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 90º turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards
GAS OUTLETS AND ACCESSORIES
Gas / Vacuum Outlets - SITC of Gas/Vacuum Outlets with Front loading type terminal outlets designed to dispense medical gases or an inlet for medical vacuum to the secondary equipment flow meters, Surgical Tools, Suction regulators, etc. Terminal unit sealed by O ring. The outlets should Quick Connect Type and gas specificity is accomplished by Diametric indexing / Geometric indexing Should havePush to IN and press-to-OUT mechanism for probes. Allows plugging of probes from front. Parking Type probe / connector Self-sealing valve on disengaging the probe (Quick disconnect) Smooth quite action Non return valve for on line servicing/ repairing , Indexed to eliminate interchangeability of gas services, Color-coded gas specific front plate Flow rate exceeds the requirements of ISO 9170 – 1. Totally leak proof, safe & easy to operate configurations possible: surface, flush & Bead-head. The terminal outlets should comply with ISO and NFPA. Body shall be of one piece brass construction.
Vacuum regulator with suction bottle -SITC of Single piece wall mounted suction collection & regulation unit With jar capacity of 600 ml each shall be provided at each of the bed side. Jars would be made of autoclavable materials. The units shall be clamped neatly to the wall using suitable clamps.
Oxygen Flow meter with Humidifier Bottle - SITC of Flow meter Back pressure Compensated Flow meter would be accurate gas flow measurement and control within a range of 0-15 liters per minute. It would meet strict precision and durability standards. Flow meter body would be made of brass material. Flow tube and shroud components would be made of clear, impact resistant polycarbonate. The humidifier bottle would be unbreakable polycarbonate material and autoclavable at 134 degrees centigrade. The humidifier would have built in safety valve.
AREA VALVE SERVICE UNIT (AVSU) with Pressure Switch and Alarm of 3 gas SITC of The AVSU can be installed as a flush or surface mounted and housed in a steel white epoxy coated box and a key operated 90° lock for security, A breakable glass front to the door gives an immediate indication as to the gas type, the valve position and the gas flow. In an emergency the glass front can be broken thus allowing access to the valve, The valve type is a 90° shut off ball valve, which is operated via a handle, and each unit comes complete with a blanking plate, which can be fitted, to either side of the valve, Each NIST include non-return valves with 100% sealing, Non-interchangeable NIST connectors are fitted upstream and downstream of the valve. The NIST connectors provide the facility to purge a system before the working gas is introduced and also following any downstream interruption of the supply. The NIST connectors also allow for the pipeline pressure to be tested and provide an easily accessible point for gas sampling. Pressure switches if required can be fitted inside the box to enable local monitoring as specified under the guidelines laid for Medical gas system as approved by Engineer HLL.
AREA VALVE SERVICE UNIT (AVSU) with Pressure Switch and Alarm of 6 gas SITC of AVSU can be installed as a flush or surface mounted and housed in a steel white epoxy coated box and a key operated 90° lock for security, A breakable glass front to the door gives an immediate indication as to the gas type, the valve position and the gas flow. In an emergency the glass front can be broken thus allowing accessto the valve, The valve type is a 90° shut off ball valve, which is operated via a handle, and each unit comes complete with a blanking plate, which can be fitted, to either side of the valve, Each NIST include non-return valves with 100% sealing, Non-interchangeable NIST connectors are fitted upstream and downstream of the valve. The NIST connectors provide the facility to purge a system before the working gas is introduced and also following any downstream interruption of the supply. The NIST connectors also allow for the pipeline pressure to be tested and provide an easily accessible point for gas sampling. Pressure switches if required can be fitted inside the box to enable local monitoring as specified under the guidelines laid for Medical gas system as approved by Engineer HLL.
BED HEAD PANEL- Supply,Installation,testing and commissioning of Bed head panels(1.2m) with Terminal unit with accessories - IV Stand, Monitor stand wall mounted, Ward vacuum unit clip, Provision for Gas/Vacuum outlets as follows - One oxygen outlet, One Vacuum outlet, One Compressed Air outlet 4 Bar, Provision for electrical and data connections as per the direction of Engineer in charge
BED HEAD PANEL- Supply, Installation,testing and commissioning of Bed head panels(1.2m) with Terminal unit with accessories - IV Stand, Monitor stand wall mounted, Ward vacuum unit clip, Provision for Gas/Vacuum outlets as follows - Two oxygen outlet, One Vacuum outlet, One Compressed Air outlet 4 Bar, Provision for electrical and data connections as per the direction of Engineer in charge
MANIFOLD ROOM EQUIPMENTS
OXYGEN MANIFOLD 5+5 - SITC of 5+5 Oxygen Manifold , High Pressure Tail Pipe with NRV Cylinder Oxygen Manifold would be suitable to withstand a pressure of 140 Kg/Cm2 and above along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 12mm I.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7 mm I.D x 1.5 mm wall thick. The design of middle and bottom frames would be provided to fit both round and flat bottom cylinders safely. The manifold would be tested (hydraulically) at 3500 pig.
AUTOMATIC OXYGEN CONTROL PANEL - SITC of automatic control panel having following features -Would be enclosed in a metal cabinet with a hinged cover. The side covers of the panel would be made of fiber glass. Panel cover would be fitted with a lock to prevent unauthorized access can be swung open for maintenance. It would be Fully Automatic Changeover operation and no manual action. The service gas would pneumatically operate gas change over system. Delivery of gas throughcontrol panel would not be dependent on electricity. Would be capable of delivering very high flow rate not less than 1300 litres per minute at delivery pressure. Would have Visual indication of the state of the manifold by 3 gauges within the control panel, which would be clearly visible through the transparent cover. Would have Audio ? visual alarm indication for changeover of empty cylinder bank to filled cylinder bank. Built in transformer to ensure safe operation by low voltage.Microprocessor based alarm signal control with high db Siren system and can be operated with single/Three phase AC system at 50 Hz.
MEDICAL AIR SYSTEM WITH AIR RECEIVER AND CONTROL PANEL - The simplex compressed Air System to be installed 01 Nos Air - cooled, Splash lubricated and tank mounted Reciprocating type compressor. Capacity to produce 1000 liters approximately free air delivery at maximum pressure of 90 PSI. It would be fitted with 5HP capacity induction electric motor of class F insulation It will be pre fitted with slide rails. The compressor would be installed duly fitted with suction filters, after coolers with moisture separator. The moisture separator and after coolers duly fitted with electrically operated auto drain traps will also be provided before air receiver. This system would also have one number vertical MS air receiver as per IS 226 with construction code IS 2825 of 250 ltr WC duly fitted with safety valves, drain valves, pressure gauges etc. An automatic twin chamber heat less air drier would also be installed to dry 20 CFM compressed air at 90-psi pressure at a temperature of 0-40 degree centigrade. Outlet dew point temperature would be ?40 degree centigrade. The dryer would be automatic duly fitted with pneumatic operated valve, set of filters, pre-filter, oil filter and duly fitted with pressure gauges for test the filter?s condition. This system would also be fitted with bypass airline, safety valve for pressure release and pressure indicators. TECHNICAL SPECIFICATION - 5HP AIR COMPRESSOR:(1nos) 1.TYPE Reciprocating, 2.Lubrication Splash Lubricated 3.Air delivery 500 lpm., 4.Working Pressure 60 psi, 5.Higher discharge 90-psi, 6.Driver Coupling, 7.Performance test As per IS 5456 8.Stages, 9.Mounting Skid (In case skid mounted) 10.Cooling Air, 11.Compressor speed650 RPM. ELECTRIC MOTOR: 1.Capacity, 415V 3 Phase, 5.Electric supply 50 Hz. 6.Performance test as per IS 325 7.Starter direct on line 8.Insulation Class F Air Receiver: 1.ConstructionIS2825 2. Capacity 1000 ltrs, 3.Foundation skid, 4.Blast cap.300psi, 5.Fittings, Pressure gauge Safety valve, Drain trap, Inspection window. Air Drier: INLET CONDITIONS 1. Flow Rate 20 cfm 2. Pressure 60psi 3. Temperature 40c Max and Moisture Contents 100%.
SITC of 8bar to 4 Bar pressure control in the pipeline system with necessary accessories and all mounting requirements. The control must be easy to operate and have provision for displaying line pressure with necessary cut of valve
AIR DRYER - SITC of Medical Breathing air dryer consists of Air dryer with 40 CFM and 6 nos of 15mm Valve , Bacterial filter with Voltage : 100 - 240 VAC, 50/60Hz, 1ph Power Consumption : 40 Watt Max, Maximum working pressure : 16bar (g), Minimum working pressure : 4 bar (g), Rated inlet Temperature : 38&deg;C, Rated inlet pressure : 7 bar(g), CO Level : 10 PPM, (Alarm set point) as per NFPA 99, Air Quality : 20C PDP (Alarm set point), as per NFPA 99, 0.01 micron particle level, Cycle Time : 4 min, Dewpoint dependent change over as per the direction of Electrical Engineer in charge. The air dryer should have large condenser for high ambient temperatures, The dryers have been designed for nominal standard inlet conditions as per ISO 7183 - 2007, Dryer quality class - ISO 8573 - 1 :2010 (E) class, Working Pressure 15kg/cm2 , Dew Point : 40 Degree.
VACUUM PLANT 5HP with 1000 litre Air receiver and Control panel - The simplex vacuum system is installed by providing 1 nos. vacuum pumps of reputed make of single stage , 1 cylinders. This pump is stationary, air cooled, splash lubricated, base plate mounted reciprocating type. This pump would fitted on base plate and belts would be guarded. The company should provide 1000 litre vacuum tank of suitable water capacity as per IS 225 and construction code as per IS 2825 with all its accessories like vacuum gauge, drain valve, inspection window etc. The company will provide interconnection copper piping of size 12mm 0.0 to 28mm OD with BSP vertical non return valve of required size with vacuum gauge of required size of bottom connection with silencer and vacuums filters and all other work to complete the vacuum system and as per the entire satisfaction of Hospitals authority. The capacity of the pump would be about 45 cfm per minute vacuum at 684mm (HB). TECHNICAL SPECIFICATION :VACCUM PUMP : 5HP (1 NOS), Lubrication Splash, Vacuum/ Suction 45cfm, Vacuum 684mm (HB)(MAX.), Driver Electric Motor, Performance test International Standard, Stages 2, Mounting Skid mounted Vertical, Cooling Air cooled 10. Vacuum speed 600 RPM, ELECTRIC MOTOR : Capacity 5H.P, Insulation Class F, VACCUM RECEIVER : Construction IS2825, Capacity 1000ltr (appox.), Foundation Skid 4. Blast Cap.300psi, Fittings, Pressure Gauge ,Safety Valve ,Drain trap Inspection Window.
NITROUS OXIDE MANIFOLD - 2X2 - SITC of 2+2 Size Nitrous Oxide Manifold would be suitable to withstand a pressure of 140 kg/cm2 and above along with high pressure copper annealed tail pipe with end Brass adapter suitable for Nitrous/oxygen Cylinder and Manifold. Top frame comprising of high pressure copper pipes of size 12mm O.Dx1.5mm wall thick, with high pressure brass fitting made of high tensile brass and connections through non –return values; high pressure copper tail pipes ,made of high pressure copper pipe of size 7mm I.d×1.5mm wall thick .The design of middle and bottom frames would be provide to fit both round and flat bottom cylinder safely.The manifold would be tested (hydraulically)at 3500 pig. Nitrous oxide 2+2 mainfold with MOX type regulator for control & 1 (outlets
CARBON DIOXIDE MANIFOLD 1X1 - SITC of 1+1 Size carbon dioxide Manifold should be configured with 1 x 1 nos. should be suitable to withstand working pressure of 145 Kg/cm2, along with 2 nos. of high-pressure copper annealed tail pipes withend brass adapter suitable for Carbon dioxide cylinders and manifold.The manifold should be so designed that it should suit easy cylinder changing and positioning. The system should have non-return valves for easy changing of cylinders without closing the bank. The cylinder should be placed with the help of cylinder brackets and fixing chains which shall be zinc plated.
OT EQUIPMENTS
Single Arm ceiling pendant - Providing, Fixing, Supply, Installation, Testing and commissioning Single Arm ceiling pendant with 1000mm long arm having weight carrying capacity of the arm will not be less than 100 Kgs, one monitor shelf and provision for six electrical sockets 6/16 Amp one number data and telephone socket and 8 nos of gas outlets.
Double dorm OT light - Supply, Installation, testing and commissioning of double dome OT light with 2,00,000 + 2,00,000 LUX, Field diameter 15-20cm, depth of field 110mm, colour temperature 4300K, colour rendering index 90Ra, intensity control 25-100, type of intensity control by control panel, LED average life>50,000 hrs, 56 Nos of LED. Optional function: Shadow Compensation, handheld wireless remote controller; smooth light focus adjustment, mutual control for both lamp head, and other functions for your options. Make: MEDILUX ALPHA B.
Surgeon Control Panel with Electrical Distribution Board - Providing, Fixing, Supply, Installation, testing and commissioning of Fully Touch Surgeon Control Panel( 6 services ) ,mounted flush in the theatre wall along Distribution Board comprising of the following -1 No Day time Clock (Digital) -1 No Lapse Time Clock (Digital) Hands free telephone -1 No Medical Gas Alarm -1 Set indicator for temperature & humdity display - Peripheral Lighting On/Off with dimming Control.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 9.95 MB
TEDOKANJIRAPALLY.pdf
Tender Documents • 9.94 MB
BOQ_1404825.xls
BOQ • 0.57 MB