GE (AF) Chiloda
GE (AF) Chiloda, LekawadaPatia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
REPAIR/REPLACEMENT AND MAINTENANCE OF GEYSER, FANS, SOLAR WATER HEATER AND CONNECTED ITEMS AT VSN CHILODA
2026_MES_794822_1
8515/26-27/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CHILODA
As per tender documents
7 documents required · 7 mandatory
₹500
GE (AF) CHILODA
₹96,000
Yes
16 Nov 2026
19 Oct 2026
18 Nov 2026
19 Oct 2026
16 Nov 2026
3 Nov 2026
19 Oct 2026 - 2 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S&F in replacement PUF insulated, seven tank processed and pure polyster powder coated, FPC based non pressurized and non heat exchanger solar water heater storage tank of capacity 100 LPD, Max working pressure 0.5 Kg/cm2, anti corrosive and heat resistant inner coating, 50 mm thick machine injected PUF insulation of 38 kg/m3 density, 0.45 mm thick precoated GI sheet outer cladding complete all as specified and directed by Engineer-in-charge. Note:- Servicing / De-scaling will be carried by OEM as approved by GE. | 2 | Each | - | - |
| 2 | S&F in replacement PUF insulated, sevemn tank processed and pure polyster powder coated, FPC based non pressurized and non heat exchanger solar water heater storage tank of capacity 1000 LPD Max working pressure 0.5 Kg/cm2, anti corrosive and heat resistant inner coating, 50 mm thick machine injected PUF insulation of 38 kg/m3 density, 0.45 mm thick precoated GI sheet outer cladding complete all as specified and directed by Engineer-in-charge. Note:- Servicing / De-scaling will be carried by OEM as approved by GE. | 2 | Each | - | - |
| 3 | S&F in replacement Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290. Gde-E-165 complete all as specified and directed by Engineer-in-charge. | 400 | Kg | - | - |
| 4 | S&F in replacement flat plate collector of size 1033mm x2033mm x95mm, as per BIS 12933 part I, copper fin aboserber plates, 9 nos of 0.56 mm rthick copper tube riser having 12.7 mm outer diameter, rockwool insulation, brass flanges complete all as specified and directed by Engineer-in-charge. Note:- Servicing / De-scaling will be carried by OEM as approved by GE. | 25 | Each | - | - |
| 5 | S&F in replacement solar water heater heating element for solar 3 Kw/3000 Watt, 1.5 inch flange Hex head nut type thread with tharmostat pocket solar heating coil as per existing sample, 230 Volt, 50 Hz, AC complete all as specified and directed by Engineer-in-charge. Note:- Servicing / De-scaling will be carried by OEM as approved by GE. | 7 | Each | - | - |
| 6 | M&L for repair/servicing and descaling of flat plate collector/ tube collector solar water heater of capacity 1000 LPD by opening of panel, servicing, cleaning, drilling, removing the scaling, breezing, closing the panel, changing flange rubber, nut and bolts complete all as specified and directed by Engineer-in-charge .Note:- Servicing / De-scaling will be carried by OEM as approved by GE. | 45 | Each | - | - |
| 7 | M&L for repair/servicing and descaling of flat plate collector/ tube collector solar water heater of capacity 100 LPD by opening of panel, servicing, cleaning, drilling, removing the scaling, breezing, closing the panel, changing flange rubber, nut and bolts complete all as specified and directed by Engineer-in-charge. Note:- Servicing / De-scaling will be carried by OEM as approved by GE. | 5 | Each | - | - |
| 8 | S&F in replacement PUF insulated makeup tank of capacity 5 ltr (as per existing sample) to be fixed on any capacity solar water heater complete all as specified and directed by Engineer-in-charge. Note:- Servicing / De-scaling will be carried by OEM as approved by GE. | 8 | Each | - | - |
| 9 | S&F in replacement Evacuated tubes double wall Glass-Glass type evacuated, 3.3 Borosilicte glass of thickness 1.6mm, selective coating with latest double walled magnetron sputtering technology, tube diameter 58 mm and length 1800 mm complete all as specified and directed by Engineer-in-charge. Note:- Servicing / De-scaling will be carried by OEM as approved by GE. | 30 | Each | - | - |
| 10 | Supply and fix in repair stainless steel Geyser Assembly 6 hole/9 hole Rectangular/ Trinagular/ round of water heater for 25/50 Ltrs capacity AC 230V as per sample complete all as specified and directed by Eng-In-Charge. | 190 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.28 MB
Tenderdocuments8515.pdf
Tender Documents • 0.78 MB
BOQ_891431.xls
BOQ • 3.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .