Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L1 | Accepted-AOC AOC | |
| 2 | L2₹28.4 L+₹39,147.89 (1.40%)Rejected-Finance | L2 | Rejected-Finance Being higher Bid | |
| 3 | L3₹29.1 L+₹1.1 L (3.88%)Rejected-Finance | L3 | Rejected-Finance Being higher Bid | |
| 4 | L4₹29.4 L+₹1.4 L (4.92%)Rejected-Finance 113 SURESH SHARMA NAGAR NEAR S S V ENTER COLLEGE BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L4 | Rejected-Finance Being higher Bid | |
| 5 | L5₹29.4 L+₹1.4 L (5.00%)Rejected-Finance 160 PREM NAGAR BAREILLY | L5 | Rejected-Finance Being higher Bid |
Tender Value
₹45.2 L
EMD Value
₹90,480
Closing Date
22 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bareilly
HQ, CWE, MES, Station Road, Bareilly
CWE BLY/GE (W) /64 OF 2023- 2024 SPECIAL REPAIRS TO BLDG NO . T-07 OF UB AREA SIG REGT UNDER GE (WEST) BAREILLY
2023_MES_635085_1
8100/B/786/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Bareilly
As per tender documents
6 documents required · 6 mandatory
₹500
GE (West) Bareilly
₹90,480
Yes
28 Feb 2024
30 Dec 2023
24 Jan 2024
30 Dec 2023
22 Jan 2024
15 Jan 2024
Amount
Demolition of cement concrete (un reinforced) in ground floor and paving n. exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of brick work in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L Brick work with fly ash bricks (old size) as per IS 12894 -2002 straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and directed.
All as per serial item No. 3 above but except brick
M&L for 10mm thick rendering on internal surface in cement mortar 1:6 to on brick masonary wall surfaces on fair faces of brick masonary finished even and smooth without using extra cement including taking down old cement plaster complete all as specified and directed.
M & L for 15 mm thick rendering on external surface on other than fair faces of brick work or concrete surfaces with cement mortar 1:4 with mixing of water proofing compound as per manufacturer’s instructions including taking down old cement plaster complete all as specified and directed. (Note:- Water Proofing compound shall be measured and paid seprately)
Supply only liquid water proofing compounding complete all as specified and directed.
M & L for applying two coats of oil bound distemper white or tinted on newly decorated or undecorated wall surface with airless electric sprayers over a coat of primer applied using airless electric sprayer over a coat of wall care putty of 1mm thick including preparation of surfaces by washing rubbing down and stoping of distempered and painted surfaces complete all as specified and directed.
M & L for applying two coats of oil bound distemper white or tinted on old decorated or undecorated wall surface with airless electric sprayers over a coat of primer applied using airless electric sprayer over a coat of wall care putty of 1mm th. including preparation of surfacesby washing rubbing down and stoping of distempered and painted surfaces complete all as specified and directed.
M&L for preparation of new plastered walls surfaces and applying two coats of Cement based paint paint over a coat of primer over chalk whitening on plastered surface complete all as specified and directed.
M&L One coat of cement base paint on old plastered wall surfaces over a coat of primer of any description including preparation of surfaces, complete all as specified
M&L for 25 mm thick cement concrete type B0, 1:2:4 (using 12.5 mm graded stone aggregate) in floors, finished rough to receive floor tiles complete all as specified and directed
M&L Virified Ceramic tiles 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or colour cement to match, over and including 15 mm thick screed plaster in CM 1:6 and dismantling of existing floor including cement mortar bedding (but not backing), removing rubbish off the premisescomplete all as specfied and directed.
All as per serial item 13 as above but as in vertical surfaces including rendering 10 mm thick in cement mortar 1:4
M&L for 75 mm thick cement concrete 1:3:6, type C1,(using 20 mm graded stone aggregate) as in floor/plinth protection, finish the surface even and smooth without using extra cement including forming necessary joints 12 mm wide to the full depth of PCC at every 3 mtr and every change of direction and filling the same with bitumen filler 1:3 by weight complete all as specified and directed.
M&L preparation of old painted wooden surfaces and applying one coat of synthetic enamel paint over 10 cm width or girth complete all as specified and directed.
M& L for Preparation of new iron surface and two coat of synthetic enamel paint ovar a coat of red oxide primer complete all as specified and directed.
M& L for Preparation of old iron surface and applying one coat of synthetic enamel paint complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
Dismentling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
S & F 4mm thick E-Board tiles for insulation and acoustic purpose of size 600x 600mm fixed with and including anodised GI prepainted snap grid with 25x25x1.5 mm thick Tee section and 38x25x2 mm thick angle with hanging/supporting arrangements as in false ceiling at bottom at spacing 60 cm centre to centre including necessary GI cleats and 4mm dia GI wire as suspender fixed to ceiling not exceeding 1.20 mtr centre both ways with dash fastners complete and making good disturbed surfaces complete all as specified and directed.
S & F for anodised GI prepainted snap grid with 25x25x1.5 mm thick Tee section and 38x25x2 mm thick angle with hanging/supporting arrangements as in false ceiling at bottom at spacing 60 cm centre to centre including necessary GI cleats and 4mm dia GI wire as suspender fixed to ceiling not exceeding 1.20 mtr centre both ways with dash fastners complete and making good disturbed surfaces including old 4mm thick E-Board tiles for insulation and acoustic purpose of size 600x 600mm fixed obtained from item no 20 and applying two coat of oil bound distemper complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / clading to wall, fixed with self tapping screws as specified complete all as specified and directed.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
M&L for Cement concrete Type C2 1:3:6 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M & L for Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate) in bed block / hold fast , roof kerbs or mud stops, rounded or chamfered on edges complete all as specified as directed.
S & F 12mm dia of neck Mild steel bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, n exc 15cm long complete all as specified as directed.
S & F 20 mm dia Mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, exc 15cm long and n exc 30cm long complete all as specified as directed.
M&L for 400x400 mmx 10 -12mm thick out door vetrified designer anti skid including designer border coloured tiles (Square/ rectangular) in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick screed bed in cm-1:6 including dismantling existing tiles/paver block complete all as specified and directed.
S&F Steel work Fe 410-W (Gde- E- 250) quality- A in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, hollow circular section or flat sections ) including distance pieces, cleats, nut bolts etc complete all as specified and directed.
S&F Rolled sections Fe 410-W (Gde- E- 250) quality- A as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates including distance pieces, cleats, nut bolts etc complete all as specified and directed.
M & L for timber Second class hard-wood in scantlings etc complete all as specified and directed.
M& L for Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote oil etc complete all as specified and directed.
S&F 5 mm thick solid Prelam PVC sheet wall panelling of thickness 5mm consisting panels of desired size stuck on inner frame work of 35mm wide strips of 5mm thick PVC sheet. The PVC strips shall be fixed to the wall using 65mm long MS screws through the groove in the strip by using PVC fastners. The distance between two screws shall not be more thant 200 mm. The strips shall be fixed to wall vertically at an equal interval of 10" between two PVC strips. A strip of 5mm thick PVC sheet of width 75mm feathered at edges shall be stuck at the places where two panels are jointed, using solvent cement and including taking down existing PVC wall paneling complete all as specified and directed.
Taking down carefully, old unserviceable aluminium point wiring (light, fan, socket, bell, buzzer or power) complete including unserviceable fittings such as switch, socket, ceiling rose, lamp holder, light fittings, bakelite sheet, terminal box, etc. and making good to disturbed surfaces of wall/floor and ceiling etc. and removal, complete all as specified and as directed by Engineer – In – Charge Note:- Existing LED bulbs/fittings are not to be removed and rates are inclusive of taking down & refixing of existing LED fitting at any location as directed. Disturbed surfaces shall be made good by plastering and applying two coats of white wash or OBD to match the existing surface finishes complete all as specified and directed.
Taking down carefully by unscrewing from DB box MCB SP/SPN/TPN of sizes & any capacity complete all as specified and directed.
Taking down carefully by sub main wiring of any size including all accessories complete all as specified and directed.
Materal and labour for Point wiring in concealed PVC conduit using stranded copper conductor cable of size 1.5 Sqmm, PVC insulated unsheathed FRLSH cable complete with all fittings and accessories but using existing sunken cast iron or pressed steel terminal box for mounting of switches, sockets, fan regulators etc but providing new cover 3mm thick laminated,(Hylem) sheet top cover fastened with chromium plated screws and 1.5 Sqmm PVC insulated stranded copper conductor FRLSH cable as continues earth wire connected to common earth dolly all as directed and as specified for the following :- NOTE: for wiring in ceiling portion conduit shall be fixed with surface of ceiling/with trusses etc. (a). One light/fan point controlled by one switch
(b). One 5-pin socket outlet 5 Amp on independent board.
(c). One 5 pin socket outlet 5 Amp on same board.
All per Srl item No 39 here-in-before, but with 2.5 Sqmm copper conductor cable complete all as specified for One 3 pin socket outlet 15 Amp on independent board.
M & L for 15 mm thick rendering on external surface on other than fair faces of brick work or concrete surfaces with cement mortar 1:6 with mixing of water proofing compound as per manufacturer’s instructions complete all as specified and directed. (Note:- Water Proofing compound shall be measured and paid seprately)
S & F Switch piano flush type polycarbonate SP one way 5 Amps complete all as specified and directed.
S&F socket out let 2 in 1 5 pin 5 amp multipurpose flash type complete all as specified and as directed.
S &F switch piano flush type polycarbonate SP one way 15 Amps complete all as specified and directed.
S&F socket out let 6 pin 2 in 1, 5/15 Amp multipurpose, flush type 240 volt complete all as specified and directed.
S&F ceiling rose PVC/Poly carbonate , Isolated body three terminal AC 230 Voltscomplete all as specified and directed.
S&F in replacement of fan regulator 150 watts electronic flush socket type with five steeped range hum free complete all as specified and as directed.
S&F in replacement surface mounting LED light fitting aluminium extruded T-5 batten , 20 Watt, 4 feet including connection with 23/0.0076 three core PVC flexible cable etc complete all as specified and directed.
M & L for replacement of lamp holder, PVC / Poly carbonate, insulated body modular type with back plate batten/angle type for batten fittings complete all as specified and & directed
Taking down carefully ceiling fan and keeping in safe custody for reuse at site after bldg repair incl Painting of ceiling fans complete, with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. painting and minor repairs etc complete all as specified and directed.
S&F in replacement security light fitting, LED type, 30 Watt, 6000 K, pressure die cast housing with prismatic polycarbonate diffuser & indvl LEDs as light source with integrated electronic driver complete with M&L GI pipe mounting bracket of size 25/32 mm dia and 1.20 m long fixed to wall with and including nut, bolts and GI clamps of size 50 x 6 mm as required including two coats of synthetic enameled paint over a coat of primer and making connection with three core 23/.0076 rubber insulated copper cable from ceiling rose to connector of street light complete all as specified and directed.
M&L for sub main wiring with two single core 4.0 Sqmm (FRLSH) copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 4.0 Sqmm (FRLSH) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. ( Note :- Two runs of 4.0 sqmm (FRLSH) and one run of 4 sqmm (FRLSH) copper conductor shall be measured as one unit length.)
S&F in replacement MCB SPN 40 Amp 240 volt complete all as specified and directed.
S&F in replacement MCB single pole 6 to 32 Amp 240 Volt 'B' curve 10 KA complete all as specified and directed.
S&F in replacement MCCB TPN 100 Amp 415V 'C' curve 10KA complete all as specified and directed.
S&F in replacement flush sheet metal enclosure SPN DB 8 way with double door IP-42 protection detachable gland plates, flush mounting for MCB fitted with bus bar , earth bar and neutral links complete all as specified and directed.
S&F in replacement flush sheet metal enclosure TPN DB 4 way 415 V with double door IP-42 protection deachable gland plates, flush mounting for MCB fitted with bus bar, earth bar and netural links, complete all as specified and directed.
Material & Labour for earthing complete including taking out old unsv and replace with galvanised steel earth plate 600x600x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using 4 mm dia GI wire as earth wire electrode moulded and rivetted to earth plate at one end and connected to main switch/ control switches of buildings at another end, GI earth wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto main switch board of building including 20 dia bore GI pipe 'light grade' as water pipe from earth chamber and including excavation and earth work, PCC 1:3:6 type C1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced complete all as specified in electric plate No. 3 of SSR Part-I and directed .
JAI SRI RAM ASSOCIATE
REHAN CONSTRUCTIONS
M/S Harshri Nath Enterprises
Builders Harpal
hardeep singh enterprises
Shikhar ji Enterprises
M/S Gupta and Company
Jain construction co
SANJEEV ENTERPRISES
shivam builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .