Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC 63 TALLA GAON POST UNCHAKOT DISTT NAINITAL 263134 UK | NAINITAL | NAINITAL | UTTARAKHAND | 263134 | ₹10.0 L Quoted ₹10.2 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹10.2 L+₹1,570 (0.15%)Rejected-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹10.2 L+₹1,570 (0.15%) | L2 | Rejected-AOC Not lowest |
| 3 | L3₹11.4 L+₹1.2 L (11.8%)Rejected-AOC | ₹11.4 L+₹1.2 L (11.8%) | L3 | Rejected-AOC Not lowest |
| 4 | L4₹12.0 L+₹1.8 L (17.7%)Rejected-AOC TARIN JALAL NAGAR SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | ₹12.0 L+₹1.8 L (17.7%) | L4 | Rejected-AOC Not lowest |
| 5 | L5₹12.2 L+₹2.1 L (20.2%)Rejected-AOC | ₹12.2 L+₹2.1 L (20.2%) | L5 | Rejected-AOC Not lowest |
Tender Value
₹12.5 L
EMD Value
₹25,000
Closing Date
10 Dec 2021, 6:00 pmClosed
GARRISON ENGINEER 871 EWS
Office of GE 871 EWS Joshimath
REPAIR/REPLACEMENT OF UNSERVICEABLE INTERNAL WIRING, LIGHT FITTINGS INCLUDING OTHER E/M ALLIED WORKS AGAINST MAINT PROGRAMM OF ZONE-II AT JOSHIMATH UNDER GE 871 EWS.
2021_MES_487831_1
8634/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 871 EWS JOSHIMATH
Class E Category b i and other criteria as per NIT
8 documents required · 8 mandatory
₹500
GE 871 EWS
₹25,000
Yes
17 Jan 2022
13 Nov 2021
13 Dec 2021
13 Nov 2021
10 Dec 2021
27 Nov 2021
13 Nov 2021 - 22 Nov 2021
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engg-in-Charge.
M&L for point wiring in PVC casing & caping of 25 mm size all as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Marked) and screws and rawal plug including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbels for One light/bell point controlled by one way switch complete all as specified and directed by Engg-in-Charge. Make of Casing and Caping is Kalinga/Polycab/Plaza and Make of PVC Copper wire : Finolex/Havells/RR Kabeel for the wiring
All as per item No 2 above but for one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 2 above but one socket outlet 5 pin 5/6 Amps on same board with other one, one way switch.
All as per item No 2 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 2.5 Sqmm for continuty earth wire connected to common earth dolly all as specified and directed by Engg-in-Charge.
M&L for Point wiring in concealed conduit with 1.5 Sqmm PVC insulated flame retardent low smoke(FRLS) single core stranded copper conductor for one light/fan/bell point in and including PVC conduit 19/20 mm dia to be terminated in pressed steel terminal boxes with 3 mm thick bakelite sheet top cover including 1.5 sqmm PVC insulated "Flame Retardent Low Smoke"( FRLS)" single core stranded copper earth continuity conductor for controlled by one switch and/or one regulator and making good the disturbed surface complete all as specified and directed by Engg-in-Charge. Note : (Wiring shall be made as per colour code in IS for Phase, neutral and earth) Make of PVC Conduit is Kalinga/Polypac/Plaza and Make of PVC Copper wire : Finolex/Havells/RR Kabeel for the wiring
All as per item No 6 above but for one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 6 above but for one socket outlet 5 pin 5/6 Amps on same board with other one, one way switch.
All as per item No 6 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 2.5 Sqmm for continuty earth wire connected to common earth dolly all as specified and directed.
S&F switch piano flush type 5/6 Amps single pole one way ISI marked complete all as specified & directed. Make : Cona/Anchor/SSK
S&F switch piano flush type 15/16 Amps single pole one way ISI marked complete all as specified & directed. Make : Cona/Anchor/SSK
S&F socket out let 5 pin 5/6 Amps ISI marked complete all as specified & directed. Make : Anchor/legrand/HPL/Cona
S&F socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps ISI marked complete all as specified & directed. Make : Cona/Anchor/SSK
S&F bell push, flush type 5 Amps white or ivory, ISI marked all as specified and directed.Make : Cona/Anchor/SSK
S&F call bell Ding Dong 230V, AC, single phase ISI marked all as specified and directed. Make : Anchor/legrand/HPL/Cona
S&F ceiling rose 2/3 terminals 65x25 mm dia poly carbonate isolated all as specified and directed. Make Cona/Anchor/plaza
S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engg-in-Charge. Make : Cona/Anchor/SSK
S&F LED light fitting two feet 1x10 watt, slim design, 230volts, indoor recess mounting down light circular type with reflector and detachable ballast tray, with lamp holder, connector block and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connectorcomplete all as specified and directed by Engg-in-Charge. Make : Philips/CG/Havells
S&F LED tube light fitting bright 18 watt slim elegant design. and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector complete all as specified and directed by Engg-in-Charge. Make : Philips/CG/Havells
S&F in replacement of building security light fitting complete with 25 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed bracket made out by GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector complete all as specified and directed by Engg-in-Charge. Make:- CG/ Bajaj/Philips/Polycab
M&L in replacement earthing complete with galvanished steel earth plate electrode size 600X600X6mm thick burried directly in ground vertically to a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level connected to and including GI earth lead wire 4mm dia by means of bolts ,nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and all as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade ,wire mesh and lugs ,GI protection pipe of 15 mm bore light grade up to 7.5 mtr long ,etc complete all as specified and directed by Engg-in-Charge. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately.
Supply and fix in replacement of DB, SPN 4 way double door for MCB, 240 volt with 200 amps rated bus barcomplete all as specified and directed by Engg-in-Charge. Make:-Legrand/Schneider/Havells
Supply and fix in replacement of DB, SPN 8 way double door for MCB, 240 volt with 200 amps rated bus bar complete all as specified and directed by Engg-in-Charge. Make:-Legrand/Schneider/Havells
Supply and fix in replacement of DB, SPN 12 way double door for MCB, 240 volt with 200 amps rated bus bar complete all as specified and directed by Engg-in-Charge. Make:-Legrand/Schneider/Havells
Supply and fix in replacement of DB, TPN 4 way vertical type with single/three phase outgoing with provision for MCCB as incomer 415 volt with 200 amps rated bus bar complete all as specified and directed by Engg-in-Charge. Make:-Legrand/Schneider/Havells
Supply and fix in replcement MCB 6-40 amps, 10 KA, SP 240 volt, 'C' series complete all as specified and directed by Engg-in-Charge. Make:-Legrand/Schneider/Havells
Supply and fix in replcement MCB 32-40 amps, 10 KA, DP 240 volt, 'C' series complete all as specified and directed by Engg-in-Charge. Make:-Legrand/Schneider/Havells
Supply and fix in replcement MCB DP 63 amps, 10 KA, DP 240 volt, 'C' series complete all as specified and directed by Engg-in-Charge. Make:-Legrand/Schneider/Havells
Supply and fix in replcement MCB TPN 63 amps, 10 KA, DP 240 volt, 'C' series complete all as specified and directed by Engg-in-Charge. Make:-Legrand/Schneider/Havells
Supply and fix in replcement MCB TPN 100 amps, 10 KA, DP 240 volt, 'C' series complete all as specified and directed by Engg-in-Charge. Make:-Legrand/Schneider/Havells
Taking down/dismantling of defective/rusted storage type hot water Geyser of 50/35/25 litre capacity from different locations by disconnecting inlet/outlet connections and , descaling/cleaning inner shell, servicing etc. checking defects, re-assembling all connected part with replacement of some defective parts and re-installing the Geyser in position, connection and testing all as specified & directed. Note :-Defective parts like PVC flexible pipe, inner tank, circular ring gasket, bottom plate and geyser assembly etc supply only will be measured and paid separately under relevent item of Schedule.
Supply only in replacement PVC flexible pipes 15mm dia (heavy duty) both end socketed set of 02 Nos with washer 450 mm long (ISI marked) for item No. 31 complete all as specified & directed. Make Prayag/Polytuff
Supply only in replacement of PVC flexible pipes 15 mm dia (heavy duty) both end socketed with washer 600 mm long set of 02 Nos for item No. 31 complete all as specified & directed. Make-Prayag/Polytuff
Supply only in replacement of stop valve fancy type cast copper alloy screwed down high pressure with crutch or butter fly handle, chromium plated screwed both ends of size 15 mm bore, for geyser connection under item No. 31 complete all as specified & directed. Make : Prayag/Essco or as per list of PS.
Supply only in replacement of inner tank 9/6 holes suitable for Geyser 25 liters any make any type(Apparatus assembly) made copper duly prewired for item No. 31 complete all as specified & directed.
Supply only in replacement of inner tank 9/6 holes suitable for Geyser 35 litres capacity any type any make (Apparatus assembly) made copper duly prewired for item No. 31 complete all as specified & directed.
Supply only in replacement of Inner tank 9/6 holes suitable for Geyser 50 litres capacity any make any type (Apparatus assembly) made copper duly prewired for item No. 31 complete all as specified & directed.
Supply only in replacement of circular ring gasket for geyser assembly 6/9 holes as per site requirement (ISI Marked)for item No. 31 complete all as specified & directed.
Supply only in replacement of bottom plate as per existing size (ISI Marked) for item No. 31 complete all as specified & directed.
Supply only in replacement of Geyser assembly (nine holes) (ISI Marked) for item No. 31 complete all as specified & directed.
Supply only in replacement of Geyser assembly (six holes) (ISI Marked) for item No. 31 complete all as specified & directed.
S & F in replacement of thermal Auto cut of range 0-90 degree centigrade (ISI marked)for Geyser any type and capacity complete all as specified & directed. Make-Dasspass/theeta.
S & F in replacement of indication lamp (Green/Red) as per required at site for Geyser any type and capacity complete all as specified & directed.
S & F in replacement of geyser heating element 1.5 KW (ISI marked) round type/thread/triangle base type with the provision of thermal cut out for Geyser any type complete all as specified & directed. Make-Dasspass/theeta
S & F in replacement of geyser heating element 2 KW (ISI marked) round/thread/triangle base type with the provision of thermal cut out Geyser any type complete all as specified & directed. Make-Dasspass/theeta
S&F in replacement of electric storage water heater of capacity 25 litres of five star rating, AC 230 volts with four numbers nut bolts duly grouted in walls including all standard accessories with flexi connection pipe of 450 mm size, glass line tank , NRV complete all as specified and directed by Engg-in-Charge. Make: Havells/CG/usha/Bajaj
Taking down carefully unserviceable exhaust fans of any size from its position, dismantling blades, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing,reassembling after replacement of defective parts including replacements of 3 core, 0.75sqmm (24/0.2mm) flexible copper cable from ceiling rose to connector, hanging on its position properly complete all as specified and directed by Engg-in-Charge. Note :- Defective parts like ball bearing, bush bearing will be measured and paid separately.
Supply only replacement of ball /bush bearing suitable for exhaust fan of same size as that of existing defective one (ISI Marked) all as specified and directed. Make : SKF/TATA//polar
S&F in replacement of condenser capacity 4/3.15/2 MFD oil filled all as specified and directed. Make : Usha/Epcos/Universal.
Cleaning and preparing the surfaces of exhaust fan any size, removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and directed by Engg-in-Charge.
M&L for burnt out rewinding exhaust fan with super enamelled bare copper conductor with the same size and number of turns as that of the old one, insulating, varnishing and pre heating for the 280 to 450 mm sweep complete all as specified and directed by Engg-in-Charge.
S&F in replecement of blade suitable for exhaust fan 300 mm size (ISI Marked) as that of existing defective one set complete all as specified and directed by Engg-in-Charge.
S&F in replecement of blade suitable for exhaust fan 450 mm size (ISI Marked) as that of existing defective one set complete all as specified and directed by Engg-in-Charge.
M&L in replacement of sub main wiring in PVC casing and caping of required size 2x4sqmm PVC insulated multistrand copper conductor FRLS with 01x2.5 Sqmm PVC insulated multistrand copper conductor as earth continuity wire complete all as specified and directed by Engg-in-Charge. Make : Havells/ Plaza/ Polycab/Finolex Note:- For the purpose of payment two runs of 4.0 sqmm conductors and one run of 2.5 sqmm conductor with casing caping will be measured as one length.
M&L in replacement of sub main wiring in PVC casing and caping of required size 2x6 sqmm PVC insulated multistrand copper conductor with 01x4 sqmm PVC insulated multistrand copper conductor FRLS as earth continuity wirecomplete all as specified and directed by Engg-in-Charge. Make : Havells/ Plaza/ Polycab/Finolex Note:- For the purpose of payment two runs of 6 sqmm conductors and one run of 4sqmm conductor with casing caping will be measured as one length.
M&L in replacement of sub main wiring in PVC conduit/conceled of required size 2 x 4 sqmm PVC insulated multistrand copper conductor FRLS with 01x2.5 sqmm PVC insulated multistrand copper conductor as earth continuity wire complete all as specified and directed by Engg-in-Charge. Make : Havells/Plaza/ Polycab Note:- For the purpose of payment two runs of 4sqmm conductors and one run of 2.5 sqmm conductor with conduit will be measured as one length.
M&L in replacement of sub main wiring in PVC concealed conduit of required size 2x6 sqmm PVC insulated multistranded copper conductor with 01x4 Sqmm PVC insulated multistrand copper conductor as earth continuity wire complete all as specified and directed by Engg-in-Charge. Make : Havells/ Plaza/Polycab Note:- For the purpose of payment two runs of 6 sqmm conductors and one run of 4sqmm conductor with conduit will be measured as one length.
Supply and fix in replacement of cable PVC insulated multi stranded aluminium conductor 1100 volt grade heavy duty served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire of size 10 sqmm 2 core flat complete all as specified and directed by Engg-in-Charge. Make : Havells/Plaza/Polycab
Taking down and dismantling of 1.5/2 Ton capacity air conditioner after disconnecting of electric connection for servicing, overhauling washing cleaning with blower and gas charging and refixing the same to its original position commissioning and testing after replacement of unserviceable parts like capacitor, compressor, condensing coil , fan motor, blower motor, fan blade, and gas charging complete all as specified and directed by Engg-in-Charge. Note :- Defective parts like capacitor, compressor, condensing coil , fan motor, blower motor, fan blade, and gas charging will be measured and paid separately under relevent item of schedule.
Supply only in replacement hermetically sealed rotary compressor complete suitable for 1.5 Ton Capacity Air conditioner complete all as specified and directed. Make : kirloskar/tecumesh
Supply only in replacement hermeticaly sealed rotary compressor complete suitable for 2 Ton Capacity Air conditioner complete all as specified and directed. Make : kirloskar/tecumesh
Supply only in replacement capacitor (Starting/running) complete suitable for 1.5//2 Ton Capacity Air conditioner (ISI Marked) complete all as specified and directed. Make –Epcos/Tipcon/Tesla
Supply only in replacement of condensing coil assembly complete suitable for 1.5//2 Ton Capacity Air conditioner complete all as specified and directed.
Supply only in replacement GAS Charging (R-22/134A) complete suitable for 1.5//2 Ton Capacity Air conditioner complete all as specified and directed.
Supply only in replacement PVC Fan blade complete suitable for 1.5//2 Ton Capacity Air conditioner (ISI Marked) complete all as specified and directed.
Supply only in replacement Fan Motor/Blower motor complete suitable for 1.5//2 Ton Capacity Air conditioner complete all as specified and directed.
Taking down and dismantling of refrigerator/deep freezer of capacity 160-320 litres of capacity after disconnecting of electric connection for servicing, overhauling washing Cleaning with new gasket of door,unserviceable tray change with new tray as per site refiregator and and gas charging and refixing the same to its original position commissioning and testing after replacement of unserviceable parts complete all as specified and directed by Engg-in-Charge. Note:- Defective parts like capacitor, compressor, condesing coil, fan motor, blower motor, fan blade and gas charging will be measured and paid separately under relevent item of schedule.
Supply only in replacement compressor suitable for 160-320 litres capacity refrigeratror. Make : KIRLOSKAR/TECUMESH/GODREJ
Supply only in replacement capacitor (starting/running) suitable for 160-320 litres capacity refrigerator (ISI Marked) all as specified and directed. Make : Epcos/Tipcon/Tesla
Supply only in replacement condesing coil assesmbly suitable for 160-320 litres capacity refrigerator all as specified and directed.
Supply only in replacement GAS charging (R-24/134A) suitable for 160-320 litres capacity refrigerator all as specified and directed.
Supply only in replacement PVC/Iron fan blade suitable for 160-320 litres capacity of refrigerator. (ISI Marked) all as specified and directed.
Supply only in replacement fan motor/blower motor suitable for 160-320 litres capacity of refrigerator all as specified and directed.
Supply and fix in replacement of LED slim square panel light fitting for surface ceiling light, 10 watt, colour white/warm white and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connectorcomplete all as specified and directed by Engg-in-Charge. Make : Havells cat part No EDGEPROSQDLR10WLED840S or equivalent wipro/Philips/crompton
Supply and fix in replacement of LED slim square panel light fitting, 36 Watt, 2x2 feet edge-lit luminaire suitable for arm strong/grid ceiling for low ceiling and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector complete all as specified and directed by Engg-in-Charge. Make: Havells cat part No STRATO2X2PLR36WLED840MOD or equivalent Philips/crompton/wipro
Supply and fix in replacement of Decorative LED 15 watt new generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector complete all as specified and directed by Engg-in-Charge. Make Havells Cat part No: CORALMINIPT15WLED757PSYMTOPC or equivalent Philips/ crompton/wipro
S & F in replacement of SSC 15 Amp including PVC gang box fixing screw ISI marked complete all as specified and directed by Engg-in-Charge.. Make : Anchor/ssk/Cona
S&F in replacement of SSC 5 Amp including PVC gang box and fixing screw ISI marked complete all as specified and directed by Engg-in-Charge. Make : Anchor/ssk/Cona
Repair/maintenance of defective/rusted storage type solar water heater of capacity 200/500/1000 litre from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts by unscrewing bolts and nuts, de-scaling/cleaning inner shell, servicing etc. checking defects, re-assembling and re-installing the solar water heater in position, insulation of pipe lines complete with building, painting of solar water stand and water tank stand with black paint weather proof, repair of leakage including soldring/gas welding and repair of foundation, replacement of electric cable as per site requiement testing complete all as specified and directed by Engg-in-Charge.
S&F in replacement of solar heating element 3 KW (ISI marked) round/thread/triangle base type with the provision of thermal cut out complete all as specified and directed by Engg-in-Charge. Make : Dasspass/Theeta
M&L in replacement of 1.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked complete all as specified and directed by Engg-in-Charge. Make : Havells/Polycab/Finolex.
M&L in replacement of 2.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked complete all as specified and directed by Engg-in-Charge. Make : Havells/RR Kabel/Finolex.
M&L in replacement modular socket 6A/16A-2/3 pin cobined 2 module complete as per site requirement 240Volts grade ISI Marked complete all as specified and directed by Engg-in-Charge. Make : Havells/Anchor /Legrand.
M&L in replacement modular socket 6A - 2/3 pin combined 2 module complete as per site requirement 240Volts grade ISI Marked complete all as specified and directed by Engg-in-Charge. Make : Havells/Anchor /Legrand.
M&L in replacement modular switch 1 way 16A, 1 module complete as per site requirement 240Volts grade ISI Marked complete all as specified and directed by Engg-in-Charge. Make : Havells/Anchor /Legrand.
M&L in replacement modular switch 1 way 6A, 1 module complete as per site requirement 240Volts grade ISI Marked complete all as specified and directed by Engg-in-Charge. Make : Havells/Anchor /Legrand.
Supply and fix in replacement PVC insulated multistrand copper conductor4.0 sqmm wire complete all as specified and directed by Engg-in-Charge. Make : Havells/ RR kabel/Finolex
Supply and fix in replacement PVC insulated multistrand copper conductor 6.0 sqmm wire complete all as specified and directed by Engg-in-Charge. Make : Havells/RR Kabel/Finolex
Supply and fix in replacement LED light fitting 4 feet 1x18 watt, slim design, 230volts, indoor recess mounting down light circular type with reflector and detachable ballast tray, with lamp holder, connector block complete all as specified and directed by Engg-in-Charge. Make : Philips/Havells/CG
Supply and fix in replacement switch piano flush type 5/6 Amps single pole one way complete all as specified and directed by Engg-in-Charge. Make : Anchor/SSK/Cona
Supply and fix in replacement switch piano flush type 15/16 Amps single pole one way complete all as specified and directed by Engg-in-Charge. Make : Anchor/SSK/Cona
Supply and fix in replacement socket out let 5 pin 5/6 Amps complete all as specified and directed by Engg-in-Charge. Make : Anchor/SSK/Cona
Supply and fix in replacement socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps complete all as specified and directed by Engg-in-Charge. Make : Anchor/SSK/Cona
Supply and fix in replacement bell push, flush type 5 Amps white or ivory, ISI marked complete all as specified and directed by Engg-in-Charge. Make : Anchor/SSK/Cona
Supply and fix in replacement call bell Ding Dong 230V, AC, single phase ISI marked complete all as specified and directed by Engg-in-Charge. Make : Anchor/SSK/Cona
Supply and fix in replacement plug top 15 Amp white or ivory, ISI marked complete all as specified and directed by Engg-in-Charge. Make : Anchor/SSK/Cona
Supply and fix in replacement plug top 5 Amp white or ivory, ISI marked complete all as specified and directed by Engg-in-Charge. Make : Anchor/SSK/Cona
Supply and fix in replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engg-in-Charge. Make : Anchor/SSK/Cona
Supply and fix in replacement 5 watt LED bulb cool day light, 230/240V AC supply complete all as specified and directed by Engg-in-Charge. Make :Havells/crompton/Bajaj
Supply and fix in replacement 9 watt LED bulb cool day light, 230/240V AC supply complete all as specified and directed by Engg-in-Charge. Make : Havells/crompton/Bajaj
Supply and fix in replacement PVC conduit 20 mm dia suitable for 1100 volt , 230/240V AC supply complete all as specified and directed by Engg-in-Charge. Make : Kalinga/Polypac/Plaza
Supply and fix in replacement PVC conduit 25 mm dia suitable for 1100 volt , 230/240V AC supply complete all as specified and directed by Engg-in-Charge. Make : Plaza/Kalinga/Polypac
Supply only insulation tape 20 mtr long each 25 Nos each packets with colour code red,blue,yellow and green 230/240V AC supply complete all as specified and directed by Engg-in-Charge. Make: Steelgrip/Standard/Anchor/Deer brand
Supply and fix in replacement Heat piller rod 750 watt 02 Nos for each set 230/240V AC supply complete all as specified and directed by Engg-in-Charge. Make: Gopi/Anchor/Belco
Bedi Refrigeration Works
Mani Control System
M/S SHAHABUDDIN AND SONS
M/S HILTRON SYTEM
Ansh Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .