Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.9 LAccepted-AOC | ₹48.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹50.4 LRejected-AOC | ₹50.4 L | L2 | Rejected-AOC L2 |
| 3 | L3₹52.4 LRejected-AOC | ₹52.4 L | L3 | Rejected-AOC L3 |
| 4 | Rejected-Technical VAYOLIPRAMBA HOUSE CHEKKODE 673645 | CHEKKODE | KOZHIKODE | KERALA | 673645 | - | - | Rejected-Technical L4 |
| Sl No | Description | Qty | Unit | RIYAS MON P. L3 | NISHAD VP L4 | MOHAMMED SHAHEER KURIKKAL M.P L1 | Sasikumaran T L2 |
|---|---|---|---|---|---|---|---|
| 1.00DETAILED ESTIMATE | |||||||
| 1.00 | 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) | 2.88 | cum | 2,237.86 ₹6,433.85 | 900 ₹2,587.50 | 3,500 ₹10,062.50 | 2,242 ₹6,445.75 |
| 1.00 | 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar | 13.34 | cum | 1,893.7 ₹25,269.53 | 900 ₹12,009.60 | 3,000 ₹40,032 | 1,898 ₹25,326.91 |
| 1.00 | OD289532/2025-2026:Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Excess cement used as per design mix is not payable (based on 5.33.2.2) All work above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 350 kg /cum | 76.49 | cum | 11,640 ₹8.9 L | 11,600 ₹8.9 L | 9,750 ₹7.5 L | 11,673 ₹8.9 L |
| 1.00 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | 345.54 | sqm | 850 ₹2.9 L | 820 ₹2.8 L | 700 ₹2.4 L | 800 ₹2.8 L |
| 1.00 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers | 389.77 | sqm | 670 ₹2.6 L | 653 ₹2.5 L | 750 ₹2.9 L | 650 ₹2.5 L |
| 1.01 | 5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts | 136.8 | sqm | 890 ₹1.2 L | 869 ₹1.2 L | 800 ₹1.1 L | 899 ₹1.2 L |
| 1.01 | 5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) | 23.84 | sqm | 733.36 ₹17,483.30 | 850 ₹20,264 | 900 ₹21,456 | 735 ₹17,522.40 |
| 1.01 | 5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges | 44.76 | sqm | 908.63 ₹40,670.28 | 908 ₹40,642.08 | 800 ₹35,808 | 911 ₹40,776.36 |
| 1.01 | 5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for:
Edges of slabs and breaks in floors and wallsUnder 20 cm wide | 81.48 | metre | 202.83 ₹16,526.59 | 920 ₹74,961.60 | 250 ₹20,370 | 203 ₹16,540.44 |
Tender Value
₹54.2 L
EMD Value
₹50,000
Closing Date
16 Feb 2026, 2:00 pmClosed
Executive Engineer
PWD Buildings division Malappuram
GENERAL GUP School Vettekkode Construction of class room building in second floor General Civil Work
2026_PWD_834510_1
BL/DN/MPM/38/2025-26
Open Tender
Civil Works - Buildings
545 days
Malappuram
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,760
Yes
₹50,000
Yes
25 Mar 2026
7 Feb 2026
18 Feb 2026
7 Feb 2026
16 Feb 2026
7 Feb 2026
DETAILED ESTIMATE
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
OD289532/2025-2026:Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Excess cement used as per design mix is not payable (based on 5.33.2.2) All work above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 350 kg /cum
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.3:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure above floor two level up to floor V level thickness 20cm and above in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
OD204562/2025-2026:Providing and fixing Pressed Steel Door frames of profile A/B/C/E of size 90 x 60mm/105 x 60mm/125 x 60mm/165 x 60 mm conforming to IS: 4351 manufactured from prime quality bright Steel sheets of 18SWG (1.25mm) thickness including Hinges jamb, lock jamb, head and if required base tie and then mitred the corners, welded to the size as per specifications and then applied with suitable primer with Pressed Steel Door Shutter made out of 20 SWG prime quality steel sheets pressed to profiles of 75 x 30mm for shutter outer frame and louvered and stiffened sheet for inner panel assembled together by welding/riveting and then pretreated,phosphated including fixing all hardware fittings such as Aldrops,Tower bolts,Hinges, and Handles etc including all cost of conveyance charges fixing charge at the site etc complete
10.31:Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer In charge.
9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
21.1.2.3:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micorn)
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
OD289533/2025-2026:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), etc., complete.Size of Tile 600 x 600 mm. as per direction of Engineer in charge.
OD289535/2025-2026:Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), etc. complete.Size of Tile 600x600 mm as per direction of Engineer in charge.
11.48.2:Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.45.1:Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
16.91.1:Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1403739.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
SBD15784.pdf
Tender Documents • 4.43 MB
BOQ_1403739.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid