Upgradation of VRF System in Shri Krishna Museum in Distt. Kurukshetra.
2024_HRY_399351_1
2024E44280E1 D431 45AE A5B4 42F04E0CBC55663BAR
Open Tender
Civil Works
Works
240 days
Ambala Cantt
Upgradation of VRF System in Shri Krishna Museum in Distt. Kurukshetra.
2 documents required · 2 mandatory
₹5,000
₹1.9 L
Yes
11 Nov 2024
12 Aug 2024
23 Aug 2024
13 Aug 2024
22 Aug 2024
13 Aug 2024
Amount
[23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA
[23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA
[23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA
[23.22.4.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.10. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 6 way ( 8 incoming 3phase*6 outgoing)
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole
Inverter based VRF System - `Supply, installation testing and commissioning of Air Cooled VRV/VRF units with Rotary /scroll Compressor capable of modulating capacity ,i,e it should be able to vary speed of the compressor as per the varying load conditions and works on R410A with heating and cooling both.The outdoor unit shall be a factory assembled unit housed in a sturdy weather proof casing constructed form rust-proofed mild steel panels coated with powder coated finish. Each ODU should have variable compressors. Each unit shall be equipped, with an oil separator to ensure stable operation with long refrigerant piping.Note:- Variable refrigerant flow modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor Outdoor unit having minimum COP at 100% Load to be )4.0 as per ARI Conditions complete in all respect upto entire satisfaction Engineer in charge of work. The manufacturer of ODU and compressor shall be same. i.e the make of compressor shall be identical of the ODU. Makes: Mitsubishi Electric, Daikin, Toshiba, Samsung, O General, LG ` Outdoor units. 24HP
Inverter based VRF System - `Supply, installation testing and commissioning of Air Cooled VRV/VRF units with Rotary /scroll Compressor capable of modulating capacity ,i,e it should be able to vary speed of the compressor as per the varying load conditions and works on R410A with heating and cooling both.The outdoor unit shall be a factory assembled unit housed in a sturdy weather proof casing constructed form rust-proofed mild steel panels coated with powder coated finish. Each ODU should have variable compressors. Each unit shall be equipped, with an oil separator to ensure stable operation with long refrigerant piping.Note:- Variable refrigerant flow modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor Outdoor unit having minimum COP at 100% Load to be )4.0 as per ARI Conditions complete in all respect upto entire satisfaction Engineer in charge of work. The manufacturer of ODU and compressor shall be same. i.e the make of compressor shall be identical of the ODU. Makes: Mitsubishi Electric, Daikin, Toshiba, Samsung, O General, LG ` Outdoor units. 48 HP
`Supply, installation testing and commissioning of Air Cooled VRV/VRF units with Rotary /scroll Compressor capable of modulating capacity ,i,e it should be able to vary speed of the compressor as per the varying load conditions and works on R410A with heating and cooling both.The outdoor unit shall be a factory assembled unit housed in a sturdy weather proof casing constructed form rust-proofed mild steel panels coated with powder coated finish. Each ODU should have variable compressors. Each unit shall be equipped, with an oil separator to ensure stable operation with long refrigerant piping.Note:- Variable refrigerant flow modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor Outdoor unit having minimum COP at 100% Load to be )3.6 as per ARI Conditions complete in all respect upto entire satisfaction Engineer in charge of work. The manufacturer of ODU and compressor shall be same. i.e the make of compressor shall be identical of the ODU. Makes: Mitsubishi Electric, Daikin, Toshiba, Samsung, O General, LG ` 6 HP
4 WAY CASSETTE INDOOR - `Supply, installation testing and commissioning of indoor units with evaporator coil, fan and fan motor drain pump drain pan and Grille pannel. The units shall be of following capacities :Makes: Mitsubishi Electric, Daikin, Toshiba, Samsung, O General,LG ` 4.5 TR `
AHU 8.0 TR-3400 CFM - `Supply, installation testing and commissioning of indoor units with 6 Row Deep evaporator coil, fan and fan motor drain pump drain pan and Grille pannel. The units shall be of following capacities :Makes: EDGETECH/ZECO ` 8 TR `
SITC of Remotes (Corded) `
SITC of REFNETS `
SITC of Refrigerant Piping of `Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline. ` 41.3 mm OD (19mm insulation) `
SITC of Refrigerant Piping of `Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline. ` 34.9 mm OD (19mm insulation) `
SITC of Refrigerant Piping of `Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline. ` 28.58 mm OD (19mm insulation) `
SITC of Refrigerant Piping of `Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline. ` 22.2mmOD (19mm insulation) `
SITC of Refrigerant Piping of `Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline. ` 19.05 mm OD (19mm insulation) `
SITC of Refrigerant Piping of `Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline. ` 15.88 mm OD (19mm insulation) `
SITC of Refrigerant Piping of `Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline. ` 12.7 mm OD (13mm insulation) `
SITC of Refrigerant Piping of `Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline. ` 9.52 mm OD (13mm insulation) `
SITC of Refrigerant Piping of `Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline. ` 6.35 mm OD (13mm insulation) `
SITC of Drain Piping - `Supply, installation testing and commissioning of Rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation complete in all respect upto entire satisfaction Engineer in charge of work. Make: Supreme, Prince, Kissan. ` 32 mm dia `
SITC of Control cabling ( As per approved makes list ) 2 Core 1.0 Sqmm `
`SITC of Providing, Fixing and Running of Centralized Controller (capable of at least to control 128 indoor units) for all VRV/VRF /AHU Indoor /Outdoor Units BMS Campatible. ` `
Civil Work (Including Holes, Chisseling, Repair and Foundations, False Ceiling Repair `
Supply and Erection of Cable Tray - 450 mm Painted
Pdg. Grille of old ducting `
SITC of Copper wire of size 2.5 Sqmm 4Core model no. WHMFDSKG42X5, Multicore Round Cables, PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010 complete in all respect upto the entire satisfaction of Engineer-in- charge (As per approved makes list ).
Supply, Erection, Testing and Commissioning of AHU Stater Box with DOL Stater having rating upto 10HP motor with ON/OFF/ Trip indication including cost of all labour and material complete in all respect up to the entire satisfaction of the Engineer in charge of the work. Make:- LandT / Havells / CandS.
`SITC of 16sqmm 4 core Copper Armd. Power Cable, loose/ in existing pipe complete in all respect with petty material and necessary connections upto the entire satisfaction of engineer in charge of work. ( As per approved makes list ). `
Less buy back of old AC System
Pacific Engineers (BID ID -1145965)
Mayur Electronics and Electricals (BID ID -1145915)
SMD SOLUTIONS (BID ID -1145980)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .