Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-AOC KR ASSISTANT CHATHUPPARA P O KANNUR | KANNUR | KANNUR | KERALA | L1 | Accepted-AOC L1 |
Tender Value
Refer Docs
EMD Value
₹15,366
Closing Date
26 Jul 2024, 3:00 pmClosed
Assisstant Executive Engineer
Office of the Assisstant Executive Engineer PWD Electrical Subdivision Thalassery
DEPOSIT-Solar at Kannur Court ComplexSITC of Solar Power Plant-General Electrical Work
2024_PWD_677797_2
PWD/BLDG/TR/22467/2023_6_1_1/1
Open Tender
Electrical Works
Item Rate
30 days
Kannur
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,355
₹15,366
19 Jan 2025
20 Jul 2024
29 Jul 2024
20 Jul 2024
26 Jul 2024
20 Jul 2024
Amount
SITC OF On grid Solar Power Plant
OD205072/2023-2024:Supply, Installation, Testing, and Commissioning of 9.8 kW on-grid Solar PV Modules of the crystalline silicon type- mono perc Half cut,Conforming to MNRE specification mounted on Aluminium frame(minimum thickness 35 mm) With minimum module efficiency of 20%, manufactured in India.As per latest edition of IEC PV module qualification test or equivalent BIS standards Crystalline Silicon, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:a) Solar Photovoltaic Module of capacity 545 Wp or above, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. ,Interconnecting between panels using solar dc cable of min 4 sqmm . PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency,The PCU/ inverters should be tested from the MNRE approved test centres / NABL /BIS /IEC accredited testing calibration laboratories ,Manufacturing warranty10years.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories, etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, a main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.g) Statutory fees such as KSEB Fees (Application Fee, Registration fee & Liasioning Fee),Electrical Inspectorate Liasioning Fee, Net meter - HT(Including Testing/Calibration Liasioning Fee) etc is included in this proposal. MAKE - Adani,Havells, Panasonic, Bosch,TATA.
OD205074/2023-2024:Providing structure work required for installation of Solar plant with purlin / single section with GI round / rectangular pipes including cutting , hoisting , fixing in position and two coat painting with suitable paint over a coat of approved steel primer , including welding and bolted with special shaped washers etc complete as required .
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
14.8:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
Bidder Name
RIJU KP
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1060043.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .