Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC 3 SHITALNATH FLATE 1 NR KHANPUR JAIN TEMPLE OPP BANK OF INDIA SHAHPUR AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹40.7 L+₹2.6 L (6.94%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹42.5 L+₹4.4 L (11.6%)Rejected-Finance KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | L3 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
22 Feb 2022, 6:00 pmClosed
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
ADDITION / ALTERATION AND SPECIAL REPAIRS TO BUILDING NO. P_80 AT NAVAL BASE AND P_4 (BADMINTON COURT) AT NAVAL PARK INS DWARKA OKHA UNDER GE NAVY PORBANDAR
2022_MES_503668_1
8790/Okha/E8
Open Tender
Civil Works
Item Rate
180 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Navy
₹76,000
Yes
25 Mar 2022
25 Jan 2022
24 Feb 2022
25 Jan 2022
22 Feb 2022
9 Feb 2022
26 Jan 2022 - 8 Feb 2022
Amount
Taking down chowkat or frames exc 1.5 Sqm and n.exc 4 Sqm each with shutter (without taking off Shutter) complete all as specified and as directed.
Taking down chowkat or frames n.exc 1.5 Sqm each with shutter (without taking off Shutter) complete all as specified and as directed.
Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube made as per specification and drawing complete all as specified and as directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, as per specification & drawing complete all as specified and directed.
100mm Butt hinges(Size of hinges in mm), medium weight, cold rolled, stainless steel, and fixed in repairs complete all as specified.
150mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
150mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified.
Aluminium (Extruded Section Body) Door closer hydraulically regulated,designation No. 3,universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg fixed in repairs complete all as specified.
Taking down aluminium windows / doors frame including Shutters of any description n exc 1.5 sq. m each with shutter (without taking off Shutter) complete all as specified and as directed.
Powder coated aluminium anodised frame and shutter for doors, windows, Ventilators and partitions with one or more rebates including necessary joining cleats, glazing clips, rubber neoprene packing, handle, stoppage, locking arrangements etc complete with powder coating of approved colour minimum thickness 50 micron complete all as specified and directed.
Aluminium Alloy wire cloth. 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified.
5.5 mm thick Sheet glass,ordinary quality pin headed type and glazing with Aluminium snap beading with rubber Neoprene packing in square exc 0.5 sq. m in each pane complete all as specified and as directed.
4mm thick Figured glass pin head type ordinery quality, glazing with oil putty in squres n.exc 0.5 sqm each pane and glazing with neoprene gasket in aluminium windows / vent complete all as specified and directed.
5mm thick plain colour PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions/fixing in aluminium door inclusive of Solvent Cement and fixing at site complete all as specified and directed.
Solar control film 25 micron reflective type pasted to glass panes as per instructions of manufacturers complete all as specified and as directed.
Taking down aluminium anodised grill of any size and any type complete all as specified and as directed.
Aluminium anodized Deco grills 6.50 mm of Design No DG 104 with suitable size F & H sections as required to aluminium/wooden windows complete all as specified and directed.
25mm dia Stainless Steel curtain rod fixed in repair / replacement complete all as specified and directed.
Statinless steel bracket for curtain rod of 25mm dia for fixing in walls fixed in repair / replacement complete all as specified and directed.
Demolition of Plain cement concrete in ground floor and paving n.exc 15 cm thick below or above ground level complete all as specified and as directed.
Hard core of broken stone or boulders of guage n exc. 63 mm, deposited, spread and levelled in layeres n exc. 150 mm thick, watered and rammed to a true surface, before concerting or otherwise complete all as specified and directed.
20 to 25 mm thick Kota stone slab including white marble strip any design as in flooring laid over and including 20mm thick screed bed in cement mortar (1:4), set & jointed in grey cement slurry mixed with pigment to match shade of slab, including rubbing grinding and mirror polishing complete all as specified and directed.
20 to 25 mm thick kota stone slab as in skirting, riser of steps and pillars over and including 15mm thick rendering in cement mortar (1:4) including rubbing grinding and mirror polishing complete all as specified and directed.
Granite of Ist quality 20 mm thick machine cut, table rubbed and polished as in flooring, steps tread, jambs, pillar, window-cills in single piece including nosing and two nos friction groove, laid over and including 20 mm thick screed bed in cement mortar (1:4) bedded and jointed with grey cement slurry and pointed with white cement mixed with admixture of pigment to match the shade of granite stone complete all as specified and as directed.
Chequered cement concrete coloured tiles ( grey cement mixed with pigment) 20cmx20cmx25mm thick set over & including 20 mm thick bedding layer in cement mortar (1:4) with neat cement and pointed in grey cement mixed with pigment to match the shade of tiles, complete all as specified and as directed.
Factory made kerb stone of M-25 grade cement concrete of size not less than 20cm (Ht) x 10cm (thickness) in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not be more than 5 mm), including making drainage opening wherever directed complete all as specified.
Dismantling stone slabs, tiles in floor, hearth or wall tiling including cement mortar bedding (but not backing), removing, rubbish off the premises complete all as specified and directed.
Vitrified Ceramic tiles 10 mm thick, Light shade coloured (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including screed bed or bedding layer 20mm thick in cement mortar 1:6 complete all as specified and as directed.
Vitrified Ceramic tiles 10 mm thick (square / rectangular) area of each tiles not exceeding 0.36 sqm, as in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including rendering 10 mm thick in cement mortar 1:4 complete all as specified and as directed.
Non skid Ceramic coloured Joint free tiles of size 400 x 400 x 8mm thick (area of each tile exceeding 0.11 Sqm but n.exc. 0.18 Sqm) as in floor set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour of tiles over and including 15mm thick bedding layering cement mortar (1:6) complete as specified and directed.
Non skid Ceramic coloured Joint free tiles of size (area of each tile exceeding 0.6 Sqm but n.exc. 0.11 Sqm) as in floor set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour of tiles over and including 15mm thick bedding layering cement mortar (1:6) complete as specified and directed.
Glazed ceramic tiles, coloured (light colour as approved), of size 450 X 300 X 8mm thick on vertical surfaces such as in skirting/dado etc set and jointed in cement slurry over 15mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete as specified and directed.
Dismantling of wall and ceiling board (Fibre, Pulp, insulation etc.) or insulation board /slab/ blankets, any thickness including cover fillets complete as specified and directed.
Mineral fibre false ceiling made out of 600x600x15 mm thick ceiling board / tiles deep panel suspensor system made out of powder coated GI sheet main tee of size 23.50x40x0.63 mm and cross tee of size 23.50 x23.50x0.63 mm and angle size 19x19x0.63 mm including 3 mm GI wire for suspending, bolts, necessary washers, nut/clits/pin hook etc. for securing frame work to ceiling to the snap grid all as directed by Engr- in- Charge including provn of necessary holes / cuttings for providing light/fan as required including making necessary recesses / projected pattern (Make: Armstrong/Dalken/Chanakya or equivalent)
Taking down cement plaster of any description incl raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
Rendering 10 mm thick on fair faces of brick work or concrete surfaces as on fair face of brick work or concrete surfaces, in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
Rendering 15 mm thick on fair faces of stone masonry surfaces or concrete surfaces on wall in CM 1:4 finished even and smooth without using extra cement including mixing Integral Water proofing treatment (where ever required as directed by Engineer in charge) complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately).
Supply only integral water proofing compound complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying one coat of white putty 2mm thick and further applying two coats of oil emulsion distemper over a coat of wall primer complete all as specified and directed.
Preparation of newly plastered surfaces of walls, soffits & facias roof and applying two coats of weather proof Acrylic based exterior emulsion paint over a coat of self primer (100% Acraylic) complete all as specified and directed.
Preparation of old plastered or unplastered surfaces of walls, soffits & facias roof and applying one coat of anti fungal weather proof Acrylic based paint complete all as specified and directed.
Complete removal of existing treatment preparation of surfaces of walls and applying one coat of wall care putty and applying two coats of water based distemper over a coat of primer complete all as specified and directed.
Preparation of old plastered or unplastered surfaces of ceilings and applying two coats of white wash complete all as specified and directed.
Preparation of old wooden surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed.
Preparation of old steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
Vitreous china white squatting pan Orissa pattern of size 580mm x 440 mm with integral foot rests including necessary cement concrete and 100 mm bore ‘P’ trap SWR (PVC) with 550 to 600 mm long neck for connecting WC to branch piece with cement joints fixed in repair complete all as specified and as directed.
Vitreous China wash down water closet (European pattern) white with connected S-Trap / P-trap, 360mm wide, 390mm high and 415 to 445mm long at top including fixing bolt Plastic water closet seat cover white closed pattern with flat bottom and cover and mild steel chromium plated hinging device including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe fixed in repairs complete all as specified and directed.
PVC low level flushing cistern 10 litres capacity valve less symphonic action type, ISI Marked white with inlet, ball valve, float and handle including brackets fixed in repairs complete all as specified and directed.
Counter top WHB min size 450x 300mm including fixing accesorise, waste coupling, waste pipe & PVC connection pipe) fixed in repair / replacement complete all as specified and directed. Make: Jaquar/ Hindware/ Cera
Vitreous China wash hand basin white flat back, size 550mm x 400mm, cutting for and pinning in ends of brackets Including waste pipe, brass coupling, 32 mm bore chromium plated brackets, restoring all connections, fixed in repairs, complete all as specified.
Pillar tap brass 15mm bore, with capstan head chromium plated fancy type screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe fixed in repairs complete all as specified and directed.
Stop valve 15mm bore, chromium plated with long shank and cup (concelead type) both ends for iron pipe fixed in repairs complete all as specified and directed.
600 mm long PVC connection suitable of 15 mm nominal bore pipe complete with brass chromium plated unions and rubber washers. The weight of brass coupling nuts shall not be less than 40 grams complete all as specified and directed.
150mm grating round/square of PTMT (Minimum weight 100 gm) openable (two piece type) complete all as specified and directed.
32mm bore and 80cm long PVC waste pipe set for WHB/sink/Urinal fixed in repairs complete all as specified.
Bib tap two way chromium plated fancy type with crutch or butterfly handle screwed down for iron pipe 15mm bore of pipe complete all as specified and directed.
Health faucet fancy type with 1mtr long flexible tube and wall hook fixed in repair / replacement complete all as specified and directed.
Stainless steel Soap dish of size 160 x 160 x 90mm or over fixed to plugs with chromium plated brass screws, fixed in repairs, complete all as specified and as directed
75mm(outlet) PVC (SWR) floor trap, plain including jointing with solvent cement and white cement complete as specified and directed.
Toilet paper holder of brass, chromium plated fixed to walls with chromium plated (CP) brass screws complete all as specified.
Brass Chromium plated towel rail, 600mm long, min 20mm dia pf superior quality, fancy type fixed in repair complete all as specified.
Taking up or down 20/25mm bore CPVC water tubing pipe and connections including cleaning for re-fixing or removal to store, complete all as directed by Engr-in-Charge.
20mm (outer dia) CPVC pipes, UV stabilised, SDR 11 pressure bearing capacity 28.12 kg/sq.cm @ 23 C ,leak proof, tough, rigid and suitable, fixed to walls with clamps / ceiling / concealed in wall including cutting chases and making good, or laid in trenches / jointed with sealant solvent leak proof including all fittings elbow, Tee, Socket, Reducer, Bushing, Step over head bends, End cap, End pugs, union, tank nipple and special fittings (brass insert threaded) like male, female treads, adapters, brass tee & reducers, male brass threaded adaptor, female brass threaded adaptor, flange including making Suitable size of brass threaded terminal to match the CP/PTMT plumbing fittings and interconnections as required for internal and external water supply applications complete all as specified and as directed.
25mm (outer dia) CPVC pipes, UV stabilised, SDR 11 pressure bearing capacity 28.12 kg/sq.cm @ 23 C ,leak proof, tough, rigid and suitable, fixed to walls with clamps / ceiling / concealed in wall including cutting chases and making good, or laid in trenches / jointed with sealant solvent leak proof including all fittings elbow, Tee, Socket, Reducer, Bushing, Step over head bends, End cap, End pugs, union, tank nipple and special fittings (brass insert threaded) like male, female treads, adapters, brass tee & reducers, male brass threaded adaptor, female brass threaded adaptor, flange including making Suitable size of brass threaded terminal to match the CP/PTMT plumbing fittings and interconnections as required for internal and external water supply applications complete all as specified and as directed.
Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges, cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm but not exc 20 cm girth complete all as specified and directed.
75mm thick PCC 1:3:6 , type C-1 using (20mm graded stone aggregate) as in plinth protection finished even & smooth without using extra cement making 10mm wide joints at every 3m interval and at every corner, filled with mixture of bitumen and sand (1:1) complete all as specified and directed.
Forming construction (Dummy) joint for 65mm deep x 10mm wide, filled with sealing compound, Grade-'B', complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, pipe line, cable , etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / disintegrated rock complete all as specified and directed.
Demolition of brickwork or stone/boulders/block masonry, built in cement mortar including all quoins, arches, pillars, ashlar facing, dressed stonework, precast concrete articles and precast concrete block walling complete all as specified and directed.
Stone masonry walling or squred walling in cm 1:6, brought upto courses using dressed same size Porbandar stone of superior quality complete all as specified and directed.
Rendering 15 mm thick on fair faces of stone masonry surfaces or concrete surfaces on wall in CM 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete or as in sub base complete all as specified and directed.
Extra for forming fair finished drain or channel 60 cm inner girth in cement concrete using extra cement including forms, moulds mitred / stopped ends complete all as specified and directed.
PCC 1:2:4 type B-1 using (20mm graded crushed stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, Benching, kneelers, apex stones, bed plates, kerbs, saucer drain(including finishing top surface of drain even and smooth without using extra cement), water troughs and the like including weathering, slightly rounded or chamfered angles and throating, and similar work including use & waste of necessary form work complete all as specified and as directed.
Demolition and breaking up drain pipes 150mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
Reinforced concrete pipes 150mm bore of pipe, class NP2, laid in trenches and jointed complete with collars complete all as specified and directed.
PCC 1:3:6 type C-2 as in bed to drain pipes of 150mm bore including packing under and haunching against the sides of pipe after they are laid and tested, including filling complete all as specified and directed.
Pre-cast RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in cover slab of manholes, septic tanks, etc. and set in cement mortar 1:6 including dismantling of damaged RCC covers slab complete all as specified and as directed. NOTE : Reinforcement will be measured and paid for separately under relevant Item(s).
Reinforced cement concrete nominal mix type A1 1:1.5:3 in (12.5 mm graded aggrigate) slab supported on walls, beam and column in floors, roofs, landing, balconies, canopies, deck slabs and shelves and the like, complete all as specified and directed.
Reinforced cement concrete nominal mix type A1 1:1.5:3 in (12.5 mm graded aggrigate) in foundation incl rafts,footings,foundation beam plinth beams, bases for columns etc. basement slabs,under-reamed piles and mass concrete complete all as specified and directed.
Reinforced cement concrete nominal mix type A1 1:1.5:3 in (12.5 mm graded aggrigate) in columns, pillars piers, posts and struts complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, complete all as specified and directed.
Use and waste of Form work to sides and soffits of suspended slabs such as roof slabs, floor slabs and similar work n exc 200 mm thick (horizontal or sloping) complete all as specified and directed.
Use and waste of Form work to sides of concrete foundations, footings, bases of columns and plinth beams and similar work, complete all as specified and directed.
Use and waste of Form work to sides of pillars, posts, struts, piers, columns and stanchions finished rough on flat surfaces complete all as specified and directed.
S&F Mild steel CRS bars 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
S&F Mild steel CRS bars 5mm dia and over upto and including 10mm dia in stirrups and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Cutting opening in cement concrete walls (any descript-ion) for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, welding & belting complete all as specified and directed.
Mild steel work as in Roof trusses (framed) made of trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) distance pieces, cleats etc including balting, rivetting and welding complete all as specified and as directed.
High tensile galvalume sheets colour coated single skin high rib / multi rib TMP Profile Galvalume sheeting in roof having 1000-1020 mm width 28 mm high crest @ maximum 250 mm pitch (centre to centre) and minimum 190mm manufactured out of 0.50 mm TCT (total coated thickness) cold rolled steel, having yield strength 550MPa minimum and wall coated with 25 micron modified polyester paint system applied on Zincalume on top and with back coating on sheet shall be 7-10 micron epoxy paint. The sheet shall be supplied in length maximum upto 6-12 meters long to suit with structural dimensions and fixed with self tapping screws with built in gasket (with bitumen washer) of suitable size machine fixed as per manufacturer instructions and applying adhesive compound to joint overlap of sheets complete all as specified and directed by Engineer-in-Charge.
Preparation of new steel surfaces of any description and applying two coats of epoxy paint over a coat of red oxide primer complete all as specified and as directed.
4mm thick ACP panel cladding, fixing on vertical or horizontal MS frame work and filling silicon gel for grove including fixing of Screw gaskets, bolts washers complete all as specified and directed.
Stainless steel letters or figures/emblems (block,roman, italian, or indian) made of SS 304 grade height of letters not less than 250mm and width not less that 200 mm each letter complete all as specified and directed
Complete removal of existing treatment, preparation of ceiling surfaces and applying two coats of water based distemper complete all as specified and directed.
Preparation for painting of kerb stone surfaces by applying two coats of synthetic enamel paint of any description over 10cm girth and width not otherwise described complete all as specified and directed.
75mm extruded aluminium alloy handles, fabricated type anodised fixed in repair / replacement complete all as specified.
Hasp and staple of aluminium anodized, safety type, 100mm long, fixed with screws fixed in repair / replacement complete all as specified.
Dismantling wrought iron or mild steel work of any description not otherwise described for of any description complete all as specified.
Dismantling Plain or corrugated steel sheeting, any type / gauge, thickness and any patten of roof coverings, hanger door, hanger roof complete all as specified.
S&F 0.56mm thick Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) complete all as specified.
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts/scaffolding all complete as per direction of Engineer-in-charge.
Providing and applying two component epoxy resin based moisture intensive "Sikadur-53UF" /BASF /Fosroc for high pressure injection grout with drilling& fixing nozzle at 500 mm centre to centre and as per manufacturer'sspecification including labour, tools, machines etc. all complete. Approx nipple @ 500mm distance & Approx Epoxy injection grout @300g / nipple
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-in-charge complete in all respect. Epoxy bonding adhesive having coverage 2.20sqm/kg of approved make
M & L for providing and applying jacketing around columns,beams, including all necessary scaffolding, shuttering,drilling holes and fixing shear anchor as per specification all complete .Note: Reinforcement shall be measured and paid separately
Providing and fixing hard drawn steel wire fabric of size 25x25mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of "L" shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge.
Providing and plaing in position Micro - Concrete as per relevant ASTM / BS / IS having comp. strength of min 45 mpa at 2 days of make PIDILITE/ BASF/SIKA/FOSROC or equivalent in columns and beams, which shall be pre-packed single component, chloride free, non shrink, free flow, self compacting and mixed as per manufacturere spacification, including required leak proof shuttering, pre - soaking of substrate, manual application or pumping, manpower and tools & tackles all complete as per direction of the Engineer - In - Charge.
Taking down carefully copper/aluminium point wiring (light/fan, buzzer, socket or power point etc) complete including all fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc including making good the disturbed surface to match with the existing all as specified and directed by Engineer-in-charge.
Taking down sub main wiring and making good disturbed surfaces of wall / floor complete all as specified and as directed.
Point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for the following:- One light or fan point controlled by one one way switch
All as per above item No. 112 but One 5 Amps 3/5 pin socket outlet on same board with other switches.
All as per above item No. 112 but One 5 Amps 3/5 pin socket outlet on independent board.
All as per above item No. 112 but One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq.mm size complete all as specified and as directed.
Point wiring with 2.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for Description a for independent switch socket outlet 6 pin 5/15 Amps complete all as Specified and directed by Engr-in-Charge.
Sub main wiring concealed with two runs of single core 6 Sqmm (Nominal area) cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, ISI marked with copper conductor drawing into rigid non-metallic PVC concealed conduit complete with including one run of 6sqmm (nominal area) single core PVC insulated multistrand unsheathed FRLS copper conductor as earth wire and duly connected to all common earth point, complete all as Specified and directed by Engr-in-Charge. (PVC Conduit shall be measured and paid separately).
Sub main wiring concealed with two runs of single core 4 Sqmm (Nominal area) cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, ISI marked with copper conductor drawing into rigid non-metallic PVC concealed conduit complete with including one run of 4 sqmm (nominal area) single core PVC insulated multistrand unsheathed FRLS copper conductor as earth wire and duly connected to all common earth point, complete all as Specified and directed by Engr-in-Charge. (PVC Conduit shall be measured and paid separately).
20 mm rigid non-metallic PVC concealed conduit medium grade including all PVC conduit accessories, cutting / chases and making good disturbed surfaces complete all as specified and directed.
Ceiling rose surface bakelite 65x50mm 3 terminal fixed in repair / replacement complete all as specified and directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with 10 Watt LED Lamp fixed in repair / replacement complete all as specified and directed.
SPN sheet metal enclosures with plug and socket with plug top and MCB SP 20 Amps fixed in repairs complete all as specified and directed.
SKYLUX LED recess mounting 18 W false ceiling luminaire to enhance the delight of occupants with comfortable experience through its classic design & glare free soft illumination complete all as specified and directed by Engineer - in - Charge. Make:Bajaj Cat Part No. 111910/ BZRSQL 18W WH or equivalent cat part of makes specified here-in-before.
Taking down existing ceiling fan / exhaust fan any size, any make, refixing the same after replacing the rubber bushes, split pin, servicing, greasing and painting with two coats of synthetic enamel paint complete all as specified and directed.
Exhaust fan 300mm sweep AC, 240 volts connecting with and including 1.5 Sqmm copper conductor, PVC insulated and PVC sheathed three core cable complete all as specified & directed by Engr in charge.
Wall mounted 10W LED natural white Engineering plastic battern,with white acrylic cover duly prewired and connecting fixed in repair / replacement complete all as specified and directed. Make:-Bajaj Cat no:- 112408/BCLSP 10 NW or equivalent cat part of makes specified here-in-before.
LED luminaire, 20W integral, sleek extruded polycarbonate LED channel, with inbuilt electronic driver / control gear, bi-pin holders, connector blocks, etc. with all connected accessories internally pre-wired, including 20W LED bulb connecting lead of 3 core 1.5sqmm flexible copper wire 1.5sqmm from ceiling rose to fitting fixed in repair / replacement complete all as specified and directed. Make: Bajaj Cat Part No. BCLSB 20WH or equivalent cat part of makes specified here-in-before.
Building street light fitting Endura pearl 20W LED lamp new genaration energy saving & environmental friendly long life made up of pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening separate driver compartment with IP65 protection and impect resistance of IK07,with suitable of GI pipe (light grade) bracket and clamps,nut bolts are fixed on wall/post fixed in repair / replacement complete all as specified and directed. Make Havells cat no ENDURAPEARLSL20WLED757SASYTOPC or equivalent cat part of makes specified here-in-before.
Modular white cover plate suitable for 1 modules with frame fixed in repair / replacement complete all as specified and directed.
Modular white cover plate suitable for 3 modules with frame fixed in repair / replacement complete all as specified and directed.
Modular white cover plate suitable for 6 modules with frame fixed in repair / replacement complete all as specified and directed.
Modular white cover plate suitable for 8 modules with frame fixed in repair / replacement complete all as specified and directed.
Modular white cover plate suitable for 12 modules combined plate-Coral with frame fixed in repair / replacement complete all as specified and directed.
Modular switch 1 way 6 Amps, 1 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Modular switch 1 way 16 Amps, 1 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Modular socket 6A, 2/3 pin combined, 2 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Modular socket 16A, 2/3 pin combined, 2 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Bell push 6A, 1 module 230 volts fixed in repair / replacement complete all as specified and directed.
Cell bell multi musical type fixed in repair / replacement complete all as specified and directed.
Ceiling fan electronic regulator five step 02 module, hum free, AC, 230 volts, 100 watts, fixed in repair / replacement complete all as specified & directed.
MCB DB Single pole and neutral 4 way double door fixed in repair / replacement complete all as specified and directed.
MCB DB Single pole and neutral 8 way double door fixed in repair / replacement complete all as specified and directed.
TPN and vertical loadline 4 way double door suitable for G frame MCCB DBs are fitted with Bus Bars, Neutral Links, Blanking Plates with incomiing MCCB 100 Amp -01 N, (4 Pole, 35 KA breaking capacity Fixed Thermal & Fixed Magnetic setting Ics = 50% of Icu) and Outgoing MCB Tpn 63 Amp -3 Nos connected with duly wire fitting on wall and smooth finishing after fixed in repair / replacement complete all as specified and directed. Make :- Havells Cat No :- DHDLVDRWGOFO04 or equivalent cat part of makes specified here-in-before.
MCB SP 240 Volts AC 6 - 32 Amps of breaking capacity 10 KA C curve, fixed in repair / replacement complete all as specified and directed.
MCB SPN 240 Volts AC 40 Amps of breaking capacity 10 KA C curve, fixed in repair / replacement complete all as specified and directed.
RCCB 63 Amp FP 100 mA,Four pole,240V,50Hz,IP-20,protection against earth fault/leakge current conforming IS-12640-12000,IEC 61008-1 fixed in repair / replacement complete all as specified and directed. Make:- Anchor Cat No- 98207 or its equivalent of L&T / Havells / Legrand
MCB TPN 40 Amps, 10 KA breaking capacity , C Curve suitable for 230 V, 50 Hz AC Supply, fixed in repairs, complete all as specified and directed by Engineer - in - Charge or compatible model cat part of make as specified in Appx 'B' hereinbefore.
MCB TPN 63 Amps, 10 KA breaking capacity , C Curve suitable for 230 V, 50 Hz AC Supply, fixed in repairs, complete all as specified and directed by Engineer - in - Charge or compatible model cat part of make as specified in Appx 'B' hereinbefore.
Wall mounted fan white colour 400mm sweep complete all as specified and as directed. Make - Havells (Platina 400) / CG or equivalent model of make as specified in Appx 'B' hereinbefore.
Material and labour for taking out window type Air conditioner 1.0 Ton capacity of any make from its original position, removing the dust from body with blower, cleaning the condenser and cooling coil using water and caustic soda solution and checking all connections including functioning of metal clad socket/ DP switch function of relay capacitors overload protector thermostat fan motor blade fan blower drum oiling / greasing of fan motor, refixing to its original location including testing making it fully functional complete all as specified & directed by Engineer-in-Charge.
Material & labour for servicing the split AC's of various capacities i.e. 1.50/2.00 Tonne by removing dust with blower, cleaning the outer & inner unit using water and caustic soda solution, checking all connections and spares making the split AC fully functional complete all as specified & directed by Engineer-in-Charge. Note for item No. 150 & 151: The cost of Minor consumeables & refrigerent Gas for top up is deemed to be included in the quoted rate.
Supply and fixing Flood light of minimum 70W luminaire grey powder coated dire-cast aluminium housing, built in control gear faceted anodised aluminium reflector heat resistant toughened clear glass cover complete all as specified and directed.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level Glvanized earth plate connected with GI earth strip 32x6mm by means of lug, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 40 mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover, fixed in repairs, including testing on completion complete all as specified and directed.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level Galvanised earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 15mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover including testing on completion complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, pipe line, cable , etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm deep as in soil complete as specified.
Removing excavated material (soil/ rock) to distance not exc 50 m and depositing where directed at a level not exc 1.5m above the starting point,complete all as specified and directed.
Fine dry river sand cushion in trenches for cable protection with a layer of sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed. Note :- Only compacted thickness will be measured and paid.
Precast concrete cable cover unreinforced, ISI marked class LV types 2 flat size 250mm x 150mm x 40mm having minimum average breaking load 200KG, complying IS:5820-1970 made of concrete used of grade M-20, laid flat in trenches over the cable with the length of concrete cover perpendicular to the direction of the cable length, adjacent / abutting each other complete all as specified.
GI tubing light grade ISI marked for cable protection at road crossing/floor/wall/ on poles or at any indicated situation etc duly sealed at both end after drawing cable including necessary clamps, saddles all as directed and specified for 40 mm bore dia, complete all as specified and directed.
Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (Heavy duly) with stranded aluminium conductor cross sectional area 50 sqmm 3.5 core suitable for working on 1100 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe and protection clamps shall be measured and paid for separately.
Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (Heavy duly) with stranded aluminium conductor cross sectional area 35 sqmm 3.5 core suitable for working on 1100 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe and protection clamps shall be measured and paid for separately.
25mm bore galvanised steel water tubing medium grade ISI marked screwed socketed joints complete with all tube fitting (such as bends, elbow, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions) and fixing complete with clips, wall hooks, wooden plugs or laying in trenches also cutting, screwing and waste and for making forged bends on piping as required at site including taking down the existing pipe line with fitting complete all as specified and as directed.
Gun-metal, ball valve, disc type with iron wheel, screwed both ends for iron pipe, ISI marked of size 25mm bore ,complete all as specified and as directed.
Note for all the items of BOQ :- (a) Materials shall be procured from manufacturer / authorized dealer. Minimum 50% of total required quantity of material as per CA shall be brought at site after sample approval but before commencement of work. The materials will be kept in the store in joint custody as specified in PS-II and same will be issued as on requirement basis. (b) The work is to be carried out in Highrise buildings. The quoted rates deemed to include Multy story and height factor. Nothing extra shall be admissible on this account. (c) Contractor shall provide all safety equipments and shall be fully responsible for the safety measures to be provided while executing the wrok. (d) The shade of colour for all finishes shall be approved by GE. Colour of Borders / lines may be different from the colour of building and nothing extra is admissible on this account.
BABUBHAI BHIMABHAI PANDAVADRA
JAY BHARAT METAL SUPPLIERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .