| Sl No | Description | Qty | Unit | supper electricals H1 | M/S SAKINA TRADERS H2 |
|---|---|---|---|---|---|
| 1.00Repair/Re-building of Partially/fully damaged Distribution transformers for the Year 2024-25. | |||||
| 1.01 | Replacement of HT Coils made out of super enamelled Aluminium winding wires of same guage and same no of turns as requuired as per transformer of any capacity including replacement of paper insulation ,insulating meterial and proper end connection .The rewinding coil shall be heat treated in an electric oven completely . Aluminium/Copper wire shall be as per ISI Standrad. | 1 | Kg | 890 ₹890 | 830 ₹830 Lowest |
| 1.02 | Replacement of LT Coils made out of super enamelled Aluminium winding wires of same guage and same no of turns as required as per transformer of any capacity including replacement of paper insulation ,insulating meterial and proper end connection .The rewinding coil shall be heat treated in an electric oven completely . Aluminium/Copper wire shall be as per ISI Standrad. | 1 | Kg | 600 ₹600 Lowest | 800 ₹800 |
| 1.03 | Painting of Transformer of any capacity indoor/outdor type after cleaning the outer surface of the transformer by rubbing with emery paper ,remove oil particles, dust etc and applying one coat of synthetic enamel paint of smoke gray colour as directed. | 1 | Each | 790 ₹790 Lowest | 900 ₹900 |
| 1.04 | Replacement of HT Bushing complete with brass spindle with nut bolt,washer ,ceramic bushing and rubber washer for Transformer capacity of 25 to 63KVA. | 1 | Each | 890 ₹890 Lowest | 950 ₹950 |
| 1.05 | Replacement of HT Bushing complete with brass spindle with nut bolt,washer ,ceramic bushing and rubber washer for Transformer capacity from100 KVA. To 250 KVA | 1 | Each | 890 ₹890 Lowest | 950 ₹950 |
| 1.06 | Replacement of HT Bushing complete with brass spindle with nut bolt,washer ,ceramic bushing and rubber washer for Transformer capacity above 250 KVA. To 400 KVA | 1 | Each | 690 ₹690 Lowest | 1,050 ₹1,050 |
| 1.07 | Replacement of HT Bushing complete with brass spindle with nut bolt,washer ,ceramic bushing and rubber washer for Transformer capacity above 400 KVA. To 630 KVA | 1 | Each | 690 ₹690 Lowest | 1,050 ₹1,050 |
| 1.08 | Replacement of LT Bushing complete with brass spindle with nut bolt,washer ,ceramic bushing and rubber washer for Transformer capacity of 25 to 63KVA. | 1 | Each | 590 ₹590 Lowest | 950 ₹950 |
| 1.09 | Replacement of LT Bushing complete with brass spindle with nut bolt,washer ,ceramic bushing and rubber washer for Transformer capacity from 100 KVA. To 250 KVA | 1 | Each | 1,190 ₹1,190 | 990 ₹990 Lowest |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
8 Jul 2024, 4:00 pmClosed
Executive Engineer, Electric Distribution Division
BAROO KARGIL
Repair/re-building of partially/fully damaged distribution transformers on contract basis for the financial year 2024-25.
2024_PDNRE_13111_1
E-NIT NO 23 of 2024-25
Open Tender
Electrical Works
Works
10 days
Kargil
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,023
Rs 1023 /- to be paid online( Account No 0096010
₹1 L
19 Jul 2024
20 Jun 2024
9 Jul 2024
21 Jun 2024
8 Jul 2024
29 Jun 2024
Repair/Re-building of Partially/fully damaged Distribution transformers for the Year 2024-25.
Replacement of HT Coils made out of super enamelled Aluminium winding wires of same guage and same no of turns as requuired as per transformer of any capacity including replacement of paper insulation ,insulating meterial and proper end connection .The rewinding coil shall be heat treated in an electric oven completely . Aluminium/Copper wire shall be as per ISI Standrad.
Replacement of LT Coils made out of super enamelled Aluminium winding wires of same guage and same no of turns as required as per transformer of any capacity including replacement of paper insulation ,insulating meterial and proper end connection .The rewinding coil shall be heat treated in an electric oven completely . Aluminium/Copper wire shall be as per ISI Standrad.
Painting of Transformer of any capacity indoor/outdor type after cleaning the outer surface of the transformer by rubbing with emery paper ,remove oil particles, dust etc and applying one coat of synthetic enamel paint of smoke gray colour as directed.
Replacement of HT Bushing complete with brass spindle with nut bolt,washer ,ceramic bushing and rubber washer for Transformer capacity of 25 to 63KVA.
Replacement of HT Bushing complete with brass spindle with nut bolt,washer ,ceramic bushing and rubber washer for Transformer capacity from100 KVA. To 250 KVA
Replacement of HT Bushing complete with brass spindle with nut bolt,washer ,ceramic bushing and rubber washer for Transformer capacity above 250 KVA. To 400 KVA
Replacement of HT Bushing complete with brass spindle with nut bolt,washer ,ceramic bushing and rubber washer for Transformer capacity above 400 KVA. To 630 KVA
Replacement of LT Bushing complete with brass spindle with nut bolt,washer ,ceramic bushing and rubber washer for Transformer capacity of 25 to 63KVA.
Replacement of LT Bushing complete with brass spindle with nut bolt,washer ,ceramic bushing and rubber washer for Transformer capacity from 100 KVA. To 250 KVA
Replacement of LT Bushing complete with brass spindle with nut bolt,washer ,ceramic bushing and rubber washer for Transformer capacity of above 250 KVA. To 400 KVA
Replacement of LT Bushing complete with brass spindle with nut bolt,washer ,ceramic bushing and rubber washer for Transformer capacity of above 400 KVA. To 630 KVA
Replacement of Breather assembly of approved make filled with silica gel suitable for Transformer of capacity 25 to 100 KVA.
Replacement of Breather assembly of approved make filled with silica gel suitable for transformer of capacity 200 to 400 KVA.
Replacement of Breather assembly of approved make filled with silica gel suitable for transformer of capacity 630 KVA
Replacement of High quality core gasket for transformer top lid cover for Transformer capacity of 25 to 100 KVA.
Replacement of High quality core gasket for transformer top lid cover for Transformer capacity of 200 to 400 KVA.
Replacement of High quality core gasket for transformer top lid cover for Transformer capacity of above 400 KVA to 630 KVA.
Repairing of Tap Changers of Distribution Transformer.
Providing and filling of fresh Transformer oil
Loading of Transformer at Divisional store Workshop 25 KVA to 100 KVA
Loading of Transformer at Divisional store Workshop 200 KVA to 630 KVA
Un-Loading of Transformer at Divisional store Workshop 25 KVA to 100 KVA
Un- Loading of Transformer at Divisional store Workshop 200 KVA to 630 KVA
Transportation of Transformer from Divisional Workshop to outside repairing agency (one Truck Load) and back to workshop
Supply of Technician/Electrician at Site as and when required.(Rate/Day)
Filteration and Dehydration of transformer oil to improve dielectric strength shall not be less than 50 KV (at 2.5 mm gap of dielectric strength test machine) and refilling oil in transformer as required complete all as specified. Note : Filteration of oil shall be carried out with centrifugal machine)
M/S SAKINA TRADERS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .