| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹30.3 L+₹41,660 (1.39%)Rejected-Finance 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹30.7 L+₹84,910 (2.84%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹34.6 L+₹4.7 L (15.8%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹39.1 L+₹9.2 L (30.8%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
| Sl No | Description | Qty | Unit | M/S VENUS BUILDER L4 | M/s Shiv Builder and Suppliers L2 | Rajesh Enterprises L5 | M/s R K Enterprises L3 | SNEH CORPORATION L1 | Narendra General Suppliers L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | S&F in replacement sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-43 DB's suitable for one MCB SPN as incoming and 6 MCB SP as out going SPN 8 way complete incl dismentaling of unservceable DB complete all as specified and directed. | 80 | Each | 1,600 ₹1,28,000 | 1,250 ₹1,00,000 Lowest | 1,300 ₹1,04,000 | 1,300 ₹1,04,000 | 1,445 ₹1,15,600 | 1,260 ₹1,00,800 |
| 2.00 | S&F in replacement sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-43 DB's suitable for one MCB SPN as incoming and 10 MCB SP as out going SPN 12 way complete incl dismentaling of unservceable DB complete all as specified and directed. | 60 | Each | 1,800 ₹1,08,000 | 1,450 ₹87,000 Lowest | 1,800 ₹1,08,000 | 1,500 ₹90,000 | 1,795 ₹1,07,700 | 1,510 ₹90,600 |
| 3.00 | S&F replacement sheet metal enclosures 415 volt TPN 4 way with 200 Amp rated bus bar, double door IP-43 DB's suitable for one No 63 to 100 Amp 10 KA TPN MCCB as incoming complete incl dismentaling of unservceable DB complete all as specified and directed. | 100 | Each | 3,000 ₹3,00,000 | 3,000 ₹3,00,000 | 2,950 ₹2,95,000 | 2,900 ₹2,90,000 | 2,685 ₹2,68,500 | 2,500 ₹2,50,000 Lowest |
| 4.00 | S&F in replacement 240V,10KA , MCB Single pole"B" series and current carrying capacity 6-32 Amps ISI marked incl dismantaling old unserviceable MCB SP complete all as specified and directed. | 910 | Each | 150 ₹1,36,500 | 100 ₹91,000 Lowest | 135 ₹1,22,850 | 130 ₹1,18,300 | 140 ₹1,27,400 | 160 ₹1,45,600 |
| 5.00 | S&F in replacement MCB Single pole & neutral "C" series upto 63. Amps ISI marked incl dismantaling old unserviceable MCB SPN complete all as specified and directed. | 250 | Each | 700 ₹1,75,000 | 750 ₹1,87,500 | 1,100 ₹2,75,000 | 800 ₹2,00,000 | 528 ₹1,32,000 Lowest | 750 ₹1,87,500 |
| 6.00 | S&F in replacement MCB TPN C Curve 100 Amp,415 V Make incl disntaling of old unserviceable TPN MCB complete all as specified and directed. | 180 | Each | 3,000 ₹5,40,000 | 1,800 ₹3,24,000 | 1,300 ₹2,34,000 | 1,500 ₹2,70,000 | 1,050 ₹1,89,000 Lowest | 6,450 ₹11,61,000 |
| 7.00 | S&F in replacement MCB TPN C Curve 63 Amps 415V Make incl disntaling of old unserviceable TPN MCB complete all as specified and directed. | 120 | Each | 850 ₹1,02,000 Lowest | 1,500 ₹1,80,000 | 2,200 ₹2,64,000 | 1,300 ₹1,56,000 | 995 ₹1,19,400 | 1,565 ₹1,87,800 |
| 8.00 | S&F in replacement MCB TP C Curve 63 Amps 415 V Make incl dismantaling of old unserviceable TP MCB complete all as specified and directed. | 240 | Each | 850 ₹2,04,000 | 1,500 ₹3,60,000 | 800 ₹1,92,000 Lowest | 900 ₹2,16,000 | 910 ₹2,18,400 | 1,265 ₹3,03,600 |
| 9.00 | M&L in repairs sub main wiring with PVC insulated and unsheathed 4x 6.0 Sq mm single core multistrandred copper conductor cable(FRLS) passing through in and including PVC conduit (25MM) surface on walls with all required accesries of conduit ISI marked and conduit accessaries fixed on surface of wall, ceiling etc, making good the distrurbed surface, incl 6 Sq mm single core copper conductor cable PVC insulated and unsheathed as earth wire. Note :- four runs of cable 6 Sqmm (FRLS) and One run of 6 Sqmm copper conductor(FRLS) along with conduit shall be measured as one unit length including taking down old UNSV submain wiring complete all as directed | 650 | RM | 400 ₹2,60,000 | 320 ₹2,08,000 Lowest | 680 ₹4,42,000 | 410 ₹2,66,500 | 395 ₹2,56,750 | 580 ₹3,77,000 |
| 10.00 | M & L in replacement Earthing complete with galvanised steel earth plate electrode 60 x x60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) wih top edge of the plate not less than 1.5 metres below normal/hard/dense ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in elevtrical plate No. 3 connected to earthing test point complete all as specified or indicated including testing on completion .
Note : Rates are deemed to be included for necessary earth work , earth pit with RCC cover of size 300X300 x25 mm etc complete all as specified and directed. | 16 | Each | 3,500 ₹56,000 | 3,500 ₹56,000 | 2,500 ₹40,000 Lowest | 3,000 ₹48,000 | 3,300 ₹52,800 | 5,000 ₹80,000 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
13 Feb 2026, 6:00 pmClosed
GE ARMY NO. 1 JODHPUR
GE ARMY NO. 1 MULTAN LINES ARMY AREA JODHPUR
REPAIR AND MAINTENANCE TO DISTRIBUTION BOARDS/ TPNS WITH ACCESSORIES AND THE BALANCING THE LOAD FOR EACH PHASE IN MD AND OTM ACCN UNDER AGE E/M-I OF GE (ARMY) No.1 JODHPUR
2026_MES_749779_1
GE/JODH (A) No 1 OF 2025-26 (9378/8)
Open Tender
Civil Works
Item Rate
270 days
Jodhpur
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE (A) No 1
₹80,000
Yes
14 Mar 2026
23 Jan 2026
20 Feb 2026
23 Jan 2026
13 Feb 2026
6 Feb 2026
S&F in replacement sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-43 DB's suitable for one MCB SPN as incoming and 6 MCB SP as out going SPN 8 way complete incl dismentaling of unservceable DB complete all as specified and directed.
S&F in replacement sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-43 DB's suitable for one MCB SPN as incoming and 10 MCB SP as out going SPN 12 way complete incl dismentaling of unservceable DB complete all as specified and directed.
S&F replacement sheet metal enclosures 415 volt TPN 4 way with 200 Amp rated bus bar, double door IP-43 DB's suitable for one No 63 to 100 Amp 10 KA TPN MCCB as incoming complete incl dismentaling of unservceable DB complete all as specified and directed.
S&F in replacement 240V,10KA , MCB Single pole"B" series and current carrying capacity 6-32 Amps ISI marked incl dismantaling old unserviceable MCB SP complete all as specified and directed.
S&F in replacement MCB Single pole & neutral "C" series upto 63. Amps ISI marked incl dismantaling old unserviceable MCB SPN complete all as specified and directed.
S&F in replacement MCB TPN C Curve 100 Amp,415 V Make incl disntaling of old unserviceable TPN MCB complete all as specified and directed.
S&F in replacement MCB TPN C Curve 63 Amps 415V Make incl disntaling of old unserviceable TPN MCB complete all as specified and directed.
S&F in replacement MCB TP C Curve 63 Amps 415 V Make incl dismantaling of old unserviceable TP MCB complete all as specified and directed.
M&L in repairs sub main wiring with PVC insulated and unsheathed 4x 6.0 Sq mm single core multistrandred copper conductor cable(FRLS) passing through in and including PVC conduit (25MM) surface on walls with all required accesries of conduit ISI marked and conduit accessaries fixed on surface of wall, ceiling etc, making good the distrurbed surface, incl 6 Sq mm single core copper conductor cable PVC insulated and unsheathed as earth wire. Note :- four runs of cable 6 Sqmm (FRLS) and One run of 6 Sqmm copper conductor(FRLS) along with conduit shall be measured as one unit length including taking down old UNSV submain wiring complete all as directed
M & L in replacement Earthing complete with galvanised steel earth plate electrode 60 x x60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) wih top edge of the plate not less than 1.5 metres below normal/hard/dense ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in elevtrical plate No. 3 connected to earthing test point complete all as specified or indicated including testing on completion . Note : Rates are deemed to be included for necessary earth work , earth pit with RCC cover of size 300X300 x25 mm etc complete all as specified and directed.
M&L in repairs sub main wiring with PVC insulated and unsheathed 2x 4 Sq mm single core multistrandred copper conductor cable(FRLS) passing through in and including PVC conduit (25 MM) surface on walls with all required accesries of conduit ISI marked and conduit accessaries fixed on surface of wall, ceiling etc, making good the distrurbed surface, incl 4 Sq mm single core copper conductor cable PVC insulated and unsheathed as earth wire. Note :- Two runs of cable 4 Sqmm (FRLS) and One run of 4 Sqmm copper conductor(FRLS) along with conduit shall be measured as one unit length including taking down old UNSV submain wiring complete all as specified and directed
M&L in repairs sub main wiring with PVC insulated and unsheathed 2x 6 Sq mm single core multistrandred copper conductor cable(FRLS) passing through in and including PVC conduit (25 MM) surface on walls with all required accesries of conduit ISI marked and conduit accessaries fixed on surface of wall, ceiling etc, making good the distrurbed surface, incl 6 Sq mm single core copper conductor cable PVC insulated and unsheathed as earth wire. Note :- Two runs of cable 6 Sqmm (FRLS) and One run of 6 Sqmm copper conductor(FRLS) along with conduit shall be measured as one unit length including taking down old UNSV submain wiring complete all as specified and directed
M&L in repairs sub main wiring with PVC insulated and unsheathed 4x 10 Sq mm single core multistrandred copper conductor cable(FRLS) passing through in and including PVC conduit (25 MM) surface on walls with all required accesries of conduit ISI marked and conduit accessaries fixed on surface of wall, ceiling etc, making good the distrurbed surface, incl 4 Sq mm single core copper conductor cable PVC insulated and unsheathed as earth wire. Note :- four runs of cable 10 Sqmm (FRLS) and One run of 10 Sqmm copper conductor(FRLS) along with conduit shall be measured as one unit length including taking down old UNSV submain wiring complete all as specified and directed
S&F Vertical Distribution Board, double Door, suitable for and including 'A' Frame FP MCCB 100A made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, TPN 4 way, 415 volts with bus bar rating 300 Amps, dust and vermin proof, suitable for incorporation of MCB’s and MCCB etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed. Note: Rate are deemed to be included for 100 Amps MCCB in the quoted rate
M&L for sub main wiring with 2 run of 4 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 25 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as specified and directed. Note:- Two run of 4 Sq.mm. and one run of 4 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces.
S&F in replacement Single pole and neutral enclosure 240 V with a two pin and earth plug and socket complete With One single Pole MCB of 20 Amp complete all as specified and directed.
M&L for Carrying out Load Balancing in Certain Buildings(Under AOR of GE(A) No.1) Including Minor Items Such as Insulation Tape, Copper/Aluminium Lux, Copper cable (1.5 to 6.0 sqmm) upto 1 mtr. , and Required T&P at sites Such as Clamp meter, hammer Drill, Screw,Nut, Bolts, Screw Gitti ,Screw Driver, plier etc complete all as specified and directed.
S&F in replacement PVC insulated armoured,heavy duty electric cable with Aluminium Conductor, 1100 Volts Grade, Cross Sectional Area 10 Sqmm 2 Core complete all as specified and directed..
NOTE:-(i)- The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
TENDERDOCUMENTS.pdf
Tender Documents • 2.14 MB
BOQ_839707.xls
BOQ • 1.99 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .