Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L1 | Accepted-AOC Lowest Bidder, Hence accepted | |
| 2 | L2₹10.5 L+₹9,973 (0.96%)Rejected-Finance 00 BEHIND COURT PHALODI NAI SARAK PHALODI JODHPUR RAJASTHAN 342301 UDYAM RJ 22 0048153 | JODHPUR | RAJASTHAN | 342301 | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹11.9 L+₹1.5 L (14.0%)Rejected-Finance 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLEGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 4 | L4₹12.0 L+₹1.5 L (14.7%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 5 | L5₹12.5 L+₹2.1 L (19.9%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
Tender Value
Refer Docs
EMD Value
₹39,960
Closing Date
22 Jan 2021, 6:00 pmClosed
GE (AF) PHALODI
Military Engineer Services Garrison Engineer (AF) Near Kundal Village, Phalodi (Rajasthan)-342 301
REPAIR/MAINT OF LT CABLE AND LT PANEL BOARDS IN TECH AREA AT AF STN PHALODI
2020_MES_407067_1
8297/A/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
PHALODI
All contractors enlisted with MES in Class E and above and category b (i) subject to the remarks wrt performance in respect of Wks in hand reflected in Workload return (WLR) Circulated by competent engineer authority
7 documents required · 7 mandatory
₹500
GE (AF) PHALODI
₹39,960
Yes
4 Feb 2021
26 Dec 2020
25 Jan 2021
26 Dec 2020
22 Jan 2021
9 Jan 2021
26 Dec 2020 - 5 Jan 2021
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth (or n exc 10 Sqm on plan and n exc 1.5 m in depth) & getting out, for pole foundation, etc. or for laying underground cable, pipe lines etc. in soft/ loose soil, complete all as specified & directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth (or n exc 10 Sqm on plan and n exc 1.5 m in depth) & getting out, for pole foundation, etc. or for laying underground cable, pipe lines etc. in hard/dense soil, complete all as specified & directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in soft / loose or hard dense soil complete all as specified and directed.
Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cutting of road / hardstanding upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable protection pipe line, making good the disturbed portion so as to match existing finishing or with PCC 1:2:4 type B1 complete all as specified and directed.
Balnk
Supplying, laying, jointing, testing and commisioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 1100 Volt grade, laid in trenches / ducts / encased in GI pipe / fixed to pole/wall with necessary angle iron support, clamp, nut , bolts etc and including taking down old unserviceable cables complete all as specified and directed for following cross sectional areas of cables :- Notes for Srl item Nos. 7.10 to 7.60 :- Excavation, earth work, sand cushioning, cable protection cover & GI pipes shall be measured and paid for separately under respective items of BOQ.
Cross Sectional area of cable 16 Sqmm, 4 core
Cross Sectional area of cable 25 Sqmm, 3.5 core
Cross Sectional area of cable 35 Sqmm, 3.5 core
Cross Sectional area of cable 50 Sqmm, 3.5 core
Cross Sectional area of cable 95 Sqmm, 3.5 core
Cross Sectional area of cable 300 Sqmm, 3.5 core
M & L for dry tibba sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover to cable all as per standard schedule rates Part-I (2009) complete all as specified and directed. Note:- Thickness after punning shall be considered for payment.
Supplying and laying in renewal of un-reinforced precast cement concrete cable cover, Class LV, Type-2, flat, size 300 mm x 180mm x 40mm laid dry and abuting each other with gap between adjecent cover not exceeding 10mm over UG cable for protection complete all as specified and directed.
Supply and lying in renewal of un-reinforced precast cement concrete cable cover LV type 1, flat, size 250mm x 150mm x 40mm laid dry and abuting each other with gap between adjecent cover not exceeding 10mm over UG cable for protection complete all as specified and directed.
M & L for cement concrete PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in pole foundation and like & including demolition of old unserviceable PCC of any description complete all as specified and directed.
S & F in renewal of aluminium cable lugs complete all as specified and directed of the following sizes :-
25 Sqmm Size
35 Sqmm Size
50 Sqmm Size
70 Sqmm Size
95 Sqmm Size
120 Sqmm Size
150 Sqmm Size
185 Sqmm Size
240 Sqmm Size
300 Sqmm Size
S & F in renewal of aluminium crimping connectors complete all as specified and directed of the following sizes :-
25 Sqmm Size
35 Sqmm Size
50 Sqmm Size
70 Sqmm Size
95 Sqmm Size
120 Sqmm Size
150 Sqmm Size
185 Sqmm Size
240 Sqmm Size
300 Sqmm Size
M & L for repair to outdoor / Indoor type LT Panel Board of any capacity / size by renewal pitted portion not exc. 1.00Sqm with existing thickness of sheet, welding work and renewal of damaged of hinges and locking arrangement and including preparation of old / new painted steel surfaces of any description over 10 cm width or girth by scrubbing the existing painted surfaces and applying two coats of synthetic enamel paint over and including a coat of red oxide primer for LT panel board/feeder pillar box of any size and shape complete all as specified and directed. Note :- LT Panel Nos. 326, 328, 448, 449, 450, 451, 452 and Parameter LT Panel-03 Nos.
S & F in renewal of MCCB, four pole, 415 Volts, 63 Amp, ultimate breaking capacity 16 KA, Ics = 75% lcu (Icu = 16 kA), 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 125 Amp, ultimate breaking capacity 16 KA, Ics = 75% lcu (Icu = 16 kA), 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 160 Amp, ultimate breaking capacity 36 KA, Ics = 75% lcu (Icu = 36 kA), 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 200 Amp, ultimate breaking capacity 36 KA, Ics = 75% lcu (Icu = 36 kA), 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 250 Amp, ultimate breaking capacity 36 KA, Ics = 75% lcu (Icu = 36 kA), 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 315 Amp, ultimate breaking capacity 36 KA, Ics = 75% lcu (Icu = 36 kA), 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 630 Amp, ultimate breaking capacity 50 KA, Ics = 75% lcu (Icu = 50 kA), 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
S & F in renewal of Volt meter 0-500 Volt, digital type of size 96mm x 96 mm square, flush mounted type having lamp accuracy glass (-1) complete all as specified and directed.
S & F in renewal of Ammeter 0-200 Amp, digital type of size 96mm x 96mm square, flush mounted type having lamp accuracy glass (-1) complete all as specified and directed.
S & F in renewal of current transformer (CT) coil suitable for Ampere meter 100/5 Amp complete all as specified and directed.
S & F in renewal of indicating lamp set RYB for phase indication operating on 240 Volt, 50 HZ, AC with new one LED panel, mounting type to match existing one complete all as specified and directed.
Mahaveer Traders
M/S HARIOM CONSTRUCTION COMPANY
M/s P K Constructions
LOKESH ELECTRICAL WORKS CONTRACTOR
M/S SOLANKI GENERAL SUPPLIERS
Aggarwal brothers and company
M/S SIDHU CONSTRUCTION COMPANY
M/S SUMAN ENTERPRISES
L C ASSOCIATES
BHARAT NIRMAN INFRASTRUCTURE COMPANY
M/S JAGDAMBA ENTERPRISES
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .