Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹34.3 LAccepted-AOC 16 A KHADRI MOHALLA SAHARANPUR CHOWK DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | 1 | Accepted-AOC lowest bid rate | |
| 2 | 2₹37.8 L+₹3.5 L (10.1%)Rejected-Finance 916 9 AWAS VIKAS COLONY RISHIKESH | DEHRADUN | UTTARAKHAND | 248001 | 2 | Rejected-Finance highest bid rate | |
| 3 | 3₹40.6 L+₹6.3 L (18.3%)Rejected-Finance | 3 | Rejected-Finance highest bid rate |
Tender Value
₹35.3 L
EMD Value
₹71,000
Closing Date
12 Apr 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer, EDC (Urban),Dehradun
Office of the Superintending Engineer, EDC (Urban),Dehradun
Work for Shifting of 11/0.4 KV composit line from Survey Chawk to Sahastradhara Crossing Under EDC(U), Dehradun
2023_UPCL4_56585_1
Tender No. 43/EDC(U)/2022-23
Open Tender
Electrical Works
Item Rate
60 days
as per tender specification
As Per Tender Specification
5 documents required · 5 mandatory
₹2,360
Superintending Engineer, EDC (Urban),Dehradun
₹71,000
4 Nov 2023
22 Mar 2023
12 Apr 2023
23 Mar 2023
12 Apr 2023
23 Mar 2023
Amount
Material
PP & Clamp MS flat 75X10 mm for SP-55 Pole with Nut-bolts.
PP & Clamp MS flat 75X10 mm for SP-72 Pole with Nut-bolts.
Stay Clamp MS flat 65X6 mm for SP-55 Pole with Nut-bolts.
Earth Wire Clamp MS flat 50X6 mm for SP-55 Pole with Nut-bolts.
Earth Wire Clamp MS flat 50X6 mm for SP-72 Pole with Nut-bolts.
Bracing Clamp ms flat 75X8 mm for SP-55 pole bottom with nut-bolts.
Bracing Clamp ms flat 75X8 mm for SP-55 pole Top with nut-bolts.
E Clamp of ms flat 75X8 mm for 33 KV Pin insulator
PG Clamp for Dog to Dog Coductor.
Nut & Bolts Full Threads in size 200X16 MM.
Labour Part
Carriage of Line material from Araghar Store to work Site including loading/unloading.
(a) ST Pole 9.0 to 13.0 M.
(b) Line /Stock material
Manual shifting of following material from road site to pit site distance approximate. 0 to 5 Km.
(a) ST Pole 9.0 to 13.0 M.
(b) Line /Stock material
Excavation of foundation pit of size 0.9x0.6x1/5th of length of pole in mixed soil and Earth back filling erection of Single supports with all accessories complete as per UPCL construction manual.
(a) ST Pole SP-55
Excavation of foundation pit of size 0.9x0.6x1/5th of length of pole in mixed soil and Earth back filling erection of Double supports with all accessories complete as per UPCL construction manual.
(a) ST Pole SP-55
Grouting of above supports 1:4:8 CC cement concrete in size 0.45x.0.45x1/5 mtr length of supports as per RESPO with UPCL construction manuals and back filling of earth and proper ramming including cost of cement course etc.
Muffing/Plinthing of pole 300 mm above ground level size 0.45x0.45 mm in CC ratio 1:3:6.
Febrication of MS Channel/MS Angle 125X65 mm/100X50 mm/65X65X6 mm, for making Bracket,Channel etc.
Mounting & fixing of HT Bracket 'F' type for single circuit line as per UPCL Construction mannual.
Erection of stay Rod including digging of pit in size of 1.2 x 0.6 x 0.6 mtr and grouting of rod in Ratio 1:4:8 CC in block of size 0.6x 0.6x0.3 mtr including nuzzling fixing tensioning and tightening complete
Erection and digging of Earthing Rod 20X2500 MM including connecting Earth electrode with ST Support with Earth Wire as per UPCL const. Manual.
Dismentaling of 33 KV line as per UPCL norms.
ACSR Dog Conductor single Ckt.
33 KV XLPE can;e 3 x 400 sq.mm
Layying, sprading & sagging of HT 33 KV line including binding complete as per UPCL norms.
ACSR Dog Conductor.
Layying, stringing and sagging of GI/Earth wire 7/16 SWG.
Layying of 33 KV cable under ground with digging of trench and hume pipe (all sizes) as per UPCL Norms
Filling and fixing of H.S. Jointing Kit 33 KV 3 x 400 sq mm -O/D type
Filling and fixing of H.S. straight through 33 KV 3 x 400 sq mm.
Gaurding over road crossing/telephone/H.T. & L.T. lines crossing with GI wire 6 & 8 SWG including laching tilli must be properly binded on both side of gaurding wire.
Dismentaling of HT and LT Single Support including all accessories complete as per UPCL construction mannual.
ST Pole SP-55/72
Dismentaling of HT and LT Double Support including all accessories complete as per UPCL construction mannual.
ST Pole SP-55
Rail pole (At place of four pole-1no.)
Dismentaling of 33 KV bracket from support.
Painting of pole ST as per UPCL norms.
Single Pole.
Double Pole.
Dismentaling of damaged gaurding 33 KV with making roll of wire used for gaurding.
Back cariage of dismentaling stock material from work site to road side within distance 0.1 to 60.0 Km.
(a) Small Stock material
(b) ST Pole SP-55/72-bottom damaged.
(C) Rail pole
Description of Work / Item(s)
Amount
Material
PP & Clamp MS flat 50X6 mm for SP-55 Pole with Nut-bolts.
LT Clamps for SP-55 pole with nut-bolts.
Bracing Clamps MS flat 50X6 mm Top for SP-55 pole with nut-bolts.
Bracing Clamps MS flat 50X6 mm Bottom for SP-55 pole with nut-bolts.
Eye hook with N/B.
PRC Connectors 95 to 95 Sq. mm.
PRC Connectors 95 to 16 Sq. mm.
Connecting leads for LT Distribution box.(1.5 Mtr long each)
LT Distribution box 3-phase 4-way for LT AB Cable
Barbered Wire (1.5 Mtr. Approx.)
Danger Board.
Al Crimping Lug of size 70 Sq. mm
Al Crimping Lug of size 120 Sq. mm
Stay clamp for SP-55 pole with nut-bolts.
LT Shackle Insulator 100X115 MM with nut-bolts.
Nut & Bolts Full Threads in size 200X16 MM.
Labour Part
Carriage of Line material from Araghar Store to work Site including loading/unloading.
ST Pole 8.0 to 8.5 M.
ST Pole 9.0 to 13.0 M.
Line /Stock material
Manual shifting of following material from road site to pit site distance approximate. 0 to 5 Km.
ST Pole 8.0 to 8.5 M.
ST Pole 9.0 to 13.0 M.
T/F 11/0.4 KV 63/100 KVA
T/F 11/0.4 KV 630 KVA
Line /Stock material
Excavation of foundation pit of size 0.9x0.6x1/5th of length of pole in mixed soil and Earth back filling erection of Single supports with all accessories complete as per UPCL construction manual.
ST Pole SP-23
ST Pole SP-55
Excavation of foundation pit of size 0.9x0.6x1/5th of length of pole in mixed soil and Earth back filling erection of Double supports with all accessories complete as per UPCL construction manual.
ST Pole SP-55
Grouting of above supports 1:4:8 CC cement concrete in size 0.45x.0.45x1/5 mtr length of supports as per RESPO with UPCL construction manuals and back filling of earth and proper ramming including cost of cement course etc.
Muffing/Plinthing of pole 300 mm above ground level size 0.45x0.45 mm in CC ratio 1:3:6.
Febrication of MS Channel/MS Angle 125X65 mm/100X50 mm/65X65X6 mm, for making Bracket,Channel etc.
Mounting & fixing of HT Bracket 'F' type for single circuit line as per UPCL Construction mannual.
Mounting & fixing of LT bracket 'D' type on erected support as per UPCL construction manual.
Dismentaling of existing 11 KV extention Bracket complete.
Dismentaling of LT Bracket from existing pole.
Erection of stay Rod including digging of pit in size of 1.2 x 0.6 x 0.6 mtr and grouting of rod in Ratio 1:4:8 CC in block of size 0.6x 0.6x0.3 mtr including nuzzling fixing tensioning and tightening complete
Dismentaling of existing stay set as per UPCL Norm.
Fixing of T/F base Channel on the above erected Double pole structure complete work as per UPCL norms for 100 KVA T/F.
Installation of following capacity new/repaired T/F 11/0.4 KV, on the D/P Structure with the help of manpower/loading equipments, withmaking all connections as per UPCL construction manual.
LT ACB 800 Amp.
Special type Earthing of T/F's Neutral and Body Separate with GI Earthing Strip and electrode including digging of Pit in depth of 15" and providing Coal & Salt in ratio 1:4(20Kg.+80Kg.), including connect earthing electrode with GI Strip.(All material provided by the Contractor own his cost).
Construction of T/F Plinth size 2x2x1.1 mtr. Above Ground level and 2.45x2.45x0.6 mtr. Below Ground level and Toe wall size 1x2x0.15 mtr. Above Ground level for installation of Distribution box as per enclosed drawing works. All the material will be arranged by Contractor at his own cost as per instruction of site incharge at site conditions.
Erection and digging of Earthing Rod 20X2500 MM including connecting Earth electrode with ST Support with Earth Wire as per UPCL const. Manual.
Mounting and Fixing of L.A. on D/P Structure including making connections with GI Earthing strip to Earthing Rod properly as per UPCL construction manual.
Mounting and fixing of Gang operated G/O Switch on erected double pole structure of T/F including making all connections with Top Channel to HT fuse Set for smooth operation.
Fixing of 11 KV fuse set o erected D/P with all connections.
Mounting and fixing of LT Fuse Set on erected double pole structure including making all connections with T/F LT Leads..
Dismentaling of 11 KV line as per UPCL norms.
ACSR Dog Conductor single Ckt.
ACSR Weasel Conductor single Ckt.
Layying, sprading & sagging of HT 11 KV line including binding complete as per UPCL norms.
ACSR Dog Conductor.
ACSR Weasel Conductor.
Layying, stringing and sagging of GI/Earth wire 7/16 SWG.
Gaurding over road crossing/telephone/H.T. & L.T. lines crossing with GI wire 6 & 8 SWG including laching tilli must be properly binded on both side of gaurding wire.
Dismentaling of LT AB Cable of size-
(a) AB Cable 3X95+1X70+1X16 Sq. mm.
Dismentaling of existing LT line (1-phase & 3-phase).
(a) ACSR Weasel Conductor.
(b) ACSR Dog Conductor.
Layying sprading & sagging of LT line 3-Ph. 5-w. including Jointing & jumppering Conductor single circuit.
(a) ACSR Weasel/Rabbit conductor.
(b) ACSR Dog Conductor.
Layying sprading & sagging of LT line 3-Ph. 5-w. including Jointing & jumppering Conductor single circuit.
(a) AB Cable 3X95+1X70+1X16 Sq. mm.
Dismentaling of HT and LT Single Support including all accessories complete as per UPCL construction mannual.
(a) ST Pole SP-55
(b) ST Pole SP-23/21
(c) PCC pole.
(d) RS Joist/Rail(Telephonic).
Dismentaling of D/P Structure complte with hardware fitting channel, TPMO, LA, Fuse set Channel/Angle etc.
(a) ST Pole SP-55
Dismentaling of D/P Structure complte with hardware fitting channel, Angle etc. including all accessories complete as per UPCL construction mannual.
(a) ST Pole SP-55
Dismentaling of exist 11 KV Extention Bracket complete.
Dismantling of LT Bracket from existing pole
Dismentaling, Removing & LT fuse set on D/P from Existing Site, due to shifting at other site.
Dismentaling, of following capacity T/F 11/0.4 KV from Plint/DP with the help of manpower/loading equipments/crane etc. after disconnection of all connections.
(c) LT ACB 800 A with all connetions
Dismentaling of following LT PVC Cable including opening of Jumpering.
(a) 1X120 Sq. mm
(b) 1X240 Sq. mm
(c) 1X400 Sq. mm
Dismentaling of 0.4 KV LT PRMC including back carriage from existing site to J.E. Store/Store Centre(Re-used at site).
Dismentaling of Fencing of 630 KVA S/S due to shifting of S/S at Road side.
Mounting & fixing of 0.4 KV LT PRMC, with LT Distribution box.
Layying of LT PVC/XLPE Cable with Crimping of AL Lugs, jumpering and mounting on pole of following size.
(a) 1X120 Sq. mm.(Including 40-Mtr. New)
(b) 1X240 Sq. mm-Re-used (Including existing cable of ACB-01 nos.)
(c) 1X400 Sq. mm Re-used (Including existing cable of ACB-01 nos.)
Disconnection & Re-connection of LT service connections, 1-phase
Disconnection & Re-connection of LT service connections, 3-phase
Opening & Re-fixing of Energy Meter from existing pole to new pole.
(a) Single Phase Meter.
(b) Three Phase Meter.
Opening & Re-fixing of Street Light from existing pole to new pole.
Painting of pole ST as per UPCL norms.
(a) Single Pole.
(b) Double Pole.
Dismentaling of damaged gaurding 11 KV line with making roll of wire used for gaurding.
Back cariage of dismentaling stock material from work site to road side within distance 0.1 to 60.0 Km.
Small Stock material
ST Pole SP-72/55/33-bottom damaged.
ST Pole SP-23/21-bottom damaged.
RS Joist/Rail/Telephonic type pole.
M/S R. B. ELECTRICALS
KUMARS ASSOCIATES
KUMARS ASSOCIATES
M/S R. B. ELECTRICALS
M/S R. B. ELECTRICALS
RJ ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .