| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC BUDOOBAGH NOWPORA 0 KHANYAR SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹16.4 L+₹2.7 L (19.7%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest | |
| 3 | L3₹16.5 L+₹2.8 L (20.7%)Rejected-AOC | L3 | Rejected-AOC Other than Lowest |
Tender Value
₹18.8 L
EMD Value
₹37,520
Closing Date
15 Jan 2024, 6:00 pmClosed
GE 969 EWS
GE 969 EWS C/O 56 APO
REPAIR REPLACEMENT OF SPLIT WINDOW AC REFRIGERATOR DEEP FREEZER AND ALLIED WKS AND REPAIR REPLACEMENT OF SOLAR WATER HEATING SYSTEM AND HAMAM GEYSER AT BARAMULA PATTAN URI RAMPUR GULMARG AND NAUGAM UNDER GE 969 EWS
2023_MES_633633_1
CA NO 969 WS - /2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 969 EWS
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 969 EWS
₹37,520
Yes
27 Feb 2024
20 Dec 2023
17 Jan 2024
20 Dec 2023
15 Jan 2024
2 Jan 2024
Amount
S&F in repair Flat Plate collector/tubular pipe suitable for Solar Hot Water System based on indirect transfer of heat of capacity 100 LPD complete all as specified and as directed.
S&F in repair Flat Plate collector/tubular pipe suitable for Solar Hot Water System based on indirect transfer of heat of capacity 200 LPD complete all as specified and as directed.
S&F in repair Flat Plate collector/tubular pipe suitable for Solar Hot Water System based on indirect transfer of heat of capacity 300 LPD complete all as specified and as directed.
Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site, complete all as specified and as directed.
M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS Copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 2.5 Sqmm as earth continuity conductor, complete all as specified and as directed.
S&F switch piano Flush type, single pole16 amp 240 volts, complete all as specified and as directed.
S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type complete all as specified and as directed.
S&F in repair backup stainless steel hot water tank duly insultated suitable for Solar Hot Water System of capacity 100 LPD complete all as specified and as directed.
S&F in repair backup stainless steel hot water tank duly insultated suitable for Solar Hot Water System of capacity 200 LPD complete all as specified and as directed.
S&F in repair backup stainless steel hot water tank duly insultated suitable for Solar Hot Water System of capacity 300 LPD complete all as specified and as directed.
S&F in repair copper pipe/tube suitable for use in Solar Hot Water System of size 1/4" complete all as specified and as directed.
S&F Hot water pipe duly insulated with glass wool and aluminium cladding 20mm bore complete all as specified and as directed.
S&F GI tubing 20mm medium grade, ISI Marked complete with all fittings and fixtures laid in trenches or laid under floors, fixed on walls with and providing clamps etc complete all as specified and as directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m depth for foundation, laying of cables, etc. and getting out in Hard/dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm depth in soil, complete all as specified and as directed.
Removing excavated material (soil ) n.exc 50m and depositing where directed at a level n.exc. where directed at a level n.exc. complete all as specified and as directed.
S&F in repair 20mm bore Bib taps, cast copper alloy with crutch or buterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S&F in repair 20mm bore stop valves, cast copper alloy screwd down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repair heating element of capcity 1.5KW (Round/Triangle/Spiral) complete all as specified and as directed.
S&F in repair heating element of directed capcity 2KW (Round/Triangle/Spiral) complete all as specified and as directed.
S&F in repair heating element of capacity 3KW (Round/triangle) suitable for Geysers as well as Solar water heater, complete all as specified and as directed.
S&F in repair thermostate suitable for 25/50 Ltr suitable for Geysers as well as Solar water heater, complete all as specified and as directed.
M&L for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete. Note :- 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.
M&L for sub main wiring with 2 run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not Iess than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete. Note :- 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.
M&L for sub main wiring with 2 run single core multistranded copper conductor cable, of size 10 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 10 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete. Note :- 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.
Servicing of geysers of any capacity by opening of entire geyser and cleaning all the sludges, blockages, dust, etc. Complete all as specified and as directed.
S&F in repairs PVC connecting pipe 18" long with brass adopters for Hot/Cold water and connecting up with complete for 25 /35/50 Itrs capacity Geysers including taking down existing unserviceable PVC connecting pipe. Complete all as specified and as directed.
S&F fusible plug melting at 90 - 100 degrees Centigrade inluding taking down existing uncerviceable fusible plug complete all as specified and as directed.
S&F high pressure valve with dead weight suitable for 25 / 50 Itrs capacity Geysers including taking down existing unserviceable high pressure valve Complete all as specified and as directed.
S&F bottom covers (set of two halves) duly painted made out of Aluminium / MS sheet of 18 SWG suitable for 25/35 / 50 Itrs capacity Geysers including taking down existing unserviceable bottom covers complete all as specified and as directed.
S&F base assembly complete with inlet, out let, thermostat pipes, drain plug and screws for fixing the element suitable for any make and capacity Geysers complete with nuts, bolts and rubber gasket including taking down existing unserviceable base assembly Complete all as specified and as directed.
M&L for repairs to water heater inner vessel including brazing. welding, testing for a pressure of 3kg / Sq.cm., re-assembling of any capacity Geysers Complete all as specified and directed by Engineer-In-Charge.
S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc
S&F Plug top 15A 240 V complete all as specified and as directed.
M&L for servicing and repairing Kero-Cum Electric based Hot water plant of any capacity and make all as specified and directed by Engr-in-Charge
S&F Photo-Cell suitable for 500 Ltr Hamam, complete all as specified and as directed.
S&F 6 Controller suitable for 500 Ltr Hamam, complete all as specified and as directed.
S&F Fuel Pump suitable for 500 Ltr Hamam, complete all as specified and as directed.
S&F in repair Nozzle suitable for 500 Ltr Hamam, complete all as specified and as directed.
S&F in repair lgnition Coil suitable for 500 Ltr Hamam, complete all as specified and as directed.
Material and labour for servicing/cleaning of complete indoor and outdoor unit of Split Type and Window type Air conditioner of 2.0 TR capacity by means of adding cleaning solution with water, cleaning of the condensor and chiller tubes shall be clean with use of nylon brushes till the scaling is removed and ensuring its serviceability of rectification/ replacement of unserviceable parts and keeping AC in good working condition complete all as specified and as directed. Note :- Supply of spares for replacement will be measured and paid separately under relevant item of Sch.
All as per serial item No. 41 above but split/ Window type AC 1.5 TR
M&L for taking out unserviceable compressor any type of Split Type AC 1.5 Ton capacity from site and replacement of compressor of existing make and sealed unit in position including charging of refrigerant gas R-22/410 of required quantity, bracing of discharge and suction line and leak testing complete all as specified and as directed.
All as per Serial item No. 43 above but for Split Type AC 2 Ton Capacity.
S&F in replacement PCB card for indoor unit of same model and make suitable for 1.5 TR Capacity split/Inverter type AC, complete all as specified and as directed.
All as per Serial item No. 45 above but for Split/Inverter Type AC 2 Ton Capacity.
S&F in replacement PCB card for outdoor unit of same model and make suitable for 1.5/2 TR Capacity split AC/Invertor type units. Complete all as specified and as directed.
S&F in replacement swing motor for indoor unit of same model and make suitable for 1.5 TR capacity split type AC units complete all as specified and directed.
All as per Serial item No. 48 above but Split Type AC 2 Ton capacity.
S&F in repair replacement a new condensing fan motor AC/DC of same model and make suitable for 1.5/2 TR capacity complete all as specified and as directed.
S&F in replacement Fan Blower of indoor unit of split AC 1.5/2 TR.
M&L for Dismantling old and unsv reverse valve and replacing with new one suitable for 1.5/2 ton capacity split AC complete all as specified and as directed.
M&L for Dismantling old and unsv sensors and replacing with new one suitable for 1.5/2 ton capacity split AC complete all as specified and as directed.
S&F in replacement of hard drawn copper pipe size suitable for existing one and connection with indoor to outdoor unit of AC plant along insulating rubber sleeves and including brazing complete all as specified and as directed.
M&L for gas charging with R-22/410 for split type AC in position including leak testing to achieve desired suction pressure and temperature (or any other cooling appliances also). Complete all as specified and as directed. Note:- Gas leakage due to unserviceable of reverse valve and copper tube will be refilled by the contractor at his own cost.
S&F in replacement of Thermostate for Deep freezer/Refrigerator of size suitable for existing one complete all as specified and as directed.
S&F in replacement of compressor for Deep Freezer of capacity 500 Ltrs with gas filling, complete all as specified and as directed.
All as per Serial item No. 57 above but Deep freezer of capacity 400/300 Ltrs.
S&F in replacement of compressor for Refrigerator with gas filling of any capacity complete all as specified and as directed.
S&F in replacement of relay of suitable amp for Refrigerator/ deep freezer complete all as specified and as directed.
Supply only remote control system of split/ window type AC of capacity 2/1.5 TR.
S&F Running capacitor 45/60 mfd for Split type Air conditioner 1.5 Ton Capacity.
M&L Puff insulation to suction pipe of split AC.
S&F in replacement copper wound Automatic voltage stabilizer, single phase naturally air-cooled indoor type & designed for input variation between 90V to 220V with output voltage stabilized upto 240V with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and as directed.
S&F in replacement voltage stabilizer for Automatic operation, single phase naturally air-cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized upto 230V with accuracy of ± 2.5% and of capacity 5 KVA.Complete all as specified and as directed.
S&F in replacement plug top 15 Amp.
S&F in replacement plug top 5 Amp.
S&F connecting cord 1.5 mtr length with plug top suitable for 1.5 Ton split/Window AC all as specified and as directed.
All as per Serial item No. 68 above but split/Window type AC 2 TR.
M&L wiring kit suitable for windows type Acs of any capacity and make.
M&L OLP for any type of AC/deep freezer/refrigerator of any capacity & make.
S&F starting capacitor 45/120 mfd for Split/window type Air conditioner 1.5/2 Ton Capacity complete all as specified and as directed.
S&F in repair, Freezer of Refrigerator as per existing make and model of any Capacity complete all as specified and directed. Note: Gas charging amt to be paid seperately in relevant item of schedule.
M&L for sub main wiring with 2 run single core multistranded copper conductor cable, of size 6 Samm. PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete. Note :- 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.
S&F in replacement of new cooling coils with fins complete, suitable for existing make and model and connection with indoor unit of split AC along with all connecting wks as brazing, Gas charging complete all as specified and as directed. NOTE: The cost of Gas is not included in the item, it should be paid seperately under relevant item
S&F in replacement of new condensing coils with fins complete, suitable for existing make and model and connection with outdoor unit of split AC along with all connecting wks as brazing wks, Gas charging complete all as specified and as directed. NOTE: The cost of Gas is not included in the item, it should be paid seperately under relevant item.
S&F in replacement of new cooling coils with fins complete, suitable for existing make and model and connection with window AC along with all connecting wks as brazing, Gas charging, complete all as specified and as directed. NOTE: The cost of Gas is not included in the item, it should be paid seperately under relevant item
S&F in replacement of new cooling coils complete with fins, suitable for existing make and model and connection with window AC along with all connecting wks as brazing, Gas charging, complete all as specified and as directed. NOTE: The cost of Gas is not included in the item, it should be paid seperately under relevant item.
M&L OLP for any type of AC/deep freezer/refrigerator of any capacity & make.
M&L for sub main wiing with 2 run single core multistranded copper conductor cable, of size 4 Sgmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete. Note :- 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.
M&L for sub main wiring with 2 run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6.0 Sgmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete. Note:- 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.
S&F 1100 V grade heavy duty cable with pvc insulated aluminium conductor served with an inner sheathing of pvc tape and overall pvc sheathed in service connection suspended by insulating hangers not more than 1mtr apart including 4mm suspension wire one twin core cable flat or circular of size 16 sqmm all as specified and directed.
Note:- Schedule of credit Rs 59,042.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
M/s SONA ULLAH LONE AND SONS
M/S KULBIR SINGH SODHI AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .