Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAdmitted-Finance | ₹9.5 L | L1 | Admitted-Finance |
| 2 | L2₹10.6 LAdmitted-Finance | ₹10.6 L | L2 | Admitted-Finance |
| 3 | L3₹11 LAdmitted-Finance | ₹11 L | L3 | Admitted-Finance |
| 4 | L4₹11.1 LAdmitted-Finance SANAT NAGAR SRINAGAR PIN 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | ₹11.1 L | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | NIGHTINGALE TRADING ENTERPRISES L3 | ECO HVAC SOLUTIONS L1 | BHAT ENGINEERING WORKS L4 | M/S LADAKH TRADERS L2 |
|---|---|---|---|---|---|---|---|
| 1.00Providing and installation of standby boiler for PHC Panikhar and allied equipments | |||||||
| 2.00 | HSD Fired, Horizontal Fire Tube , Hot Water Generator fitted with combustion equipment’s-burner assembly, all boiler mountings- control panel, control valves, accessories including primary circulation pumps of suitable capacity, including chimney of required dia, externally mounted at 8mtr above ground level or as recommended by OEM.
Job includes control valves/strainers/NRVs and pressure and temperature gauges of required capacities.
Boiler Capacity =3.00 Lac- Kcal/ Hr | 1 | Job | 5,40,000 ₹5.4 L | 5,00,000 ₹5 L | 7,50,000 ₹7.5 L | 7,18,020 ₹7.2 L |
| 3.00 | Replacement of Common header;
MS C-class pipe as per IS-1239 & IS 3589 pipe of following nominal size with necessary clamps, vibration isolators and fitting (but excluding valves, stationers, gauges etc). duly insulated with 80kg/cum design resin bonded fibre glass or 144 kg/cum mineral wool (non-combustible) pipe section insulation covered with alyer of 120gm/sqm polythene sheet (vapor barrier) and finally applying 0.63 aluminum sheet cladding complete with type3, grade 1 roofing feltstrip at joints and repair to the damage to building etc as per specifications as required. Including valves, strainers as per requirement.
150 mm DIA (50mm insulation) | 30 | RM | 2,000 ₹60,000 | 3,500 ₹1.1 L | 2,650 ₹79,500 | 2,725 ₹81,750 |
| 4.00 | Hot Water Circulation Mono-block Pump (secondary) complete with electric motor mounted common base frame duly grouted in cement concrete foundation along with control valves (Sluice valve NRVs of minimum PN 10 rating) of desired size and capacities, Discharge: 10-12 LPS at 25m Head RPM= 1480 | 2 | job | 50,000 ₹1 L | 35,000 ₹70,000 | 35,000 ₹70,000 | 46,790 ₹93,580 |
| 5.00 | Hot Water Radiators Steel panel heating radiators conforming to EN442 with working pressure ranging from 10-13 bar having working temperature at 110°C , complete with Top grilles and side covers as standard along-with inlet valve, outlet valve, air purge valve and threaded plug as per OEM. Inlet Water Temp: 75oC Outlet Water Temp: 65oC Room Temp: 22oC
4000 Kcal/Hr (Type 33) | 6 | No | 25,000 ₹1.5 L | 25,000 ₹1.5 L | 26,500 ₹1.6 L | 20,025 ₹1.2 L |
| 6.00 | Coolant
Providing and filling of Nontoxic antifreeze Coolant IOCL Servo Kool Plus or equivalent. | 500 | Litre | 500 ₹2.5 L | 250 ₹1.3 L | 110 ₹55,000 | 83 ₹41,500 |
Tender Value
Refer Docs
EMD Value
₹22,000
Closing Date
12 Dec 2025, 2:00 pmClosed
Executive Engineer Mechanical Division Kargil.
Office of the Executive Engineer Mechanical Division Kargil.
Supply, installation, testing, and commissioning of a standby hot water generator along with all allied works for the Central Heating System at PHC Panikhar
2025_PWD_18115_1
MDK/E-NIT/53 OF 2025-26
Open Tender
Machineries/ Mechanical Engg Items
Kargil
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,200
Executive Engineer Mechanical Division Kargil
₹22,000
23 Dec 2025
5 Dec 2025
13 Dec 2025
6 Dec 2025
12 Dec 2025
6 Dec 2025
Amount
Providing and installation of standby boiler for PHC Panikhar and allied equipments
HSD Fired, Horizontal Fire Tube , Hot Water Generator fitted with combustion equipment’s-burner assembly, all boiler mountings- control panel, control valves, accessories including primary circulation pumps of suitable capacity, including chimney of required dia, externally mounted at 8mtr above ground level or as recommended by OEM. Job includes control valves/strainers/NRVs and pressure and temperature gauges of required capacities. Boiler Capacity =3.00 Lac- Kcal/ Hr
Replacement of Common header; MS C-class pipe as per IS-1239 & IS 3589 pipe of following nominal size with necessary clamps, vibration isolators and fitting (but excluding valves, stationers, gauges etc). duly insulated with 80kg/cum design resin bonded fibre glass or 144 kg/cum mineral wool (non-combustible) pipe section insulation covered with alyer of 120gm/sqm polythene sheet (vapor barrier) and finally applying 0.63 aluminum sheet cladding complete with type3, grade 1 roofing feltstrip at joints and repair to the damage to building etc as per specifications as required. Including valves, strainers as per requirement. 150 mm DIA (50mm insulation)
Hot Water Circulation Mono-block Pump (secondary) complete with electric motor mounted common base frame duly grouted in cement concrete foundation along with control valves (Sluice valve NRVs of minimum PN 10 rating) of desired size and capacities, Discharge: 10-12 LPS at 25m Head RPM= 1480
Hot Water Radiators Steel panel heating radiators conforming to EN442 with working pressure ranging from 10-13 bar having working temperature at 110°C , complete with Top grilles and side covers as standard along-with inlet valve, outlet valve, air purge valve and threaded plug as per OEM. Inlet Water Temp: 75oC Outlet Water Temp: 65oC Room Temp: 22oC 4000 Kcal/Hr (Type 33)
Coolant Providing and filling of Nontoxic antifreeze Coolant IOCL Servo Kool Plus or equivalent.
M/S LADAKH TRADERS (BID ID -175719)
NIGHTINGALE TRADING ENTERPRISES (BID ID -175821)
BHAT ENGINEERING WORKS (BID ID -175924)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.06 MB
BOQ_43789.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid