Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC | ₹1.0 Cr Quoted ₹1.1 Cr | L1 | Accepted-AOC Lowest Bid Accepted |
| 2 | L2₹1.1 Cr+₹1.5 L (1.38%)Rejected-Finance 50 1 56 13 SURYA TOWERS ASR NAGAR SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | ₹1.1 Cr+₹1.5 L (1.38%) | L2 | Rejected-Finance Not Being Lowest Bidder |
| 3 | L3₹1.1 Cr+₹5.4 L (5.09%)Rejected-Finance MIG 1 12 GULLALAPALEM VUDA COLONY SRIHARIPURAM MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | ₹1.1 Cr+₹5.4 L (5.09%) | L3 | Rejected-Finance Not Being Lowest Bidder |
| 4 | L4₹1.2 Cr+₹11.4 L (10.8%)Rejected-Finance | ₹1.2 Cr+₹11.4 L (10.8%) | L4 | Rejected-Finance Not Being Lowest Bidder |
| 5 | L5₹1.3 Cr+₹20.0 L (19.0%)Rejected-Finance | ₹1.3 Cr+₹20.0 L (19.0%) | L5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
21 Mar 2022, 6:00 pmClosed
Shri VK Tiwari, IDSE, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
Special Repairs to Building No. P 171 at NAD, Visakhapatnam
2022_MES_508008_1
82238/E8
Open Tender
Civil Works
Item Rate
270 days
Visakhapatnam
Class B
Category a i
9 documents required · 9 mandatory
₹1,000
Garrison Engineer Naval Depot
₹2.0 L
Yes
31 Mar 2022
14 Feb 2022
26 Mar 2022
14 Feb 2022
21 Mar 2022
7 Mar 2022
14 Feb 2022 - 21 Feb 2022
Amount
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] not exceeding 1.5 Sq.m each and removing to store complete all as specified and as directed.
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] exceeding 1.5 Sq.m but not exceeding 4.00 Sq.m each and removing to store complete all as specified and as directed.
S & F Second Class Hard Wood, plain, solid, straight Chowkats and Frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
S & F 40 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S & F PVC Solid Ventilator frame size 55 X 47mm with wall thickness of 5mm made out of extruded 5mm PVC sheet, mitre cut at two comers and jointed with 2 Nos of 150mm long brackets of 15 x 15mm MS square tube, the two vatted profiles are to be reinforced with 19 x 19mm MS square tube, 50% of bottom portion is fixed with 4mm thick pin headed glass and balance 50% of top portion is fixed with 4mm thick pin headed glass louvers and covered with 0.36mm dia stainless steel wire mesh at top portion including necessary PVC beading with screws and 3 Nos 12mm dia MS guard, bars fixed in ventilator frame including two coats of synthetic enamel paint over a coat of red oxide primer to MS guard bars etc all as per specified and directed.
S & F 30mm thick, Factory made, Second Class Hard Wood, Glazed and Skeleton Shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares, with plain, chamfered or rounded, mitred and rebated Sash Bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part – I, Section 8, Clause 8.24 [b] and fitted to Chowkats complete all as specified and as directed.
S & F 3mm thick sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed.
S & F Sheet Glass, ordinary quality, 5 mm thick and glazing with rubber gasket in squares not exceeding 0.50 Sq.m in each pane complete all as specified and as directed.
S & F 50 micron thick sun control film Reflective type and fixing on glass panel as required complete all as specified and as directed.
S & F Powder Coated Aluminium Deco Grill of Model / Design No. DG 104 (7mmx4.2mm), including Powder Coated Aluminium Channel of size 20 X 10 X 1.5mm for fixing Deco Grill complete all as specified and as directed.
S & F Solid PVC door frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening of Sintex or its equivalent make as approved by Accepting Officer complete all as specified and as directed.
S & F Factory made solid panel PVC door shutter 30 mm thick [Style] consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC "C" Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement fixing in frame at site as per specification complete all as specified and as directed.
S & F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed
S & F Rolled Mild Steel work confirming to Fe 410-W, Grade-E- 250, Quality-A as in Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering, Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings [exclusive of steel sheeting or other covering, running rails and guides] and hanging, also fastening and fixing complete all as specified and as directed.
S & F Aluminium anodised Handle, Cast Type, of size 150 mm complete all as specified and as directed.
S & F Aluminium anodised Handle, Cast Type, of size 100 mm complete all as specified and as directed.
S & F 100 mm size, Butt hinges, Extruded Aluminium alloy with stainless steel hinge pin, anodised, Type B-21, including fixtures complete all as specified and as directed.
S & F 75 mm size, Butt hinges, Extruded Aluminium alloy with stainless steel hinge pin, anodised, Type B-21, including fixtures complete all as specified and as directed.
S & F Aluminium anodised barrel Tower Bolt of size 125 mm size of extruded section complete all as specified and as directed.
S & F Aluminium anodised barrel Tower Bolt of size 100 mm size of extruded section complete all as specified and as directed.
S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 250 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S & F 300mm size mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
S & F Mild Steel work confirming to Fe - 290, Grade E-165 as in Bands, Straps, Supports or Stays for Rainwater/ Ventilating Pipes, including Bolts, if required, Hooks [Stay] heavy for Large Gates, Hook and Pintle Hinges, large Hasps and Staples, Chains, hand made Sliding Bolts, Clamps, Hold Fasts, Wall Ties, Hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles complete all as specified and as directed.
M & L for PCC 1:3:6, Type C-1, using 20 mm graded stone aggregate as in Coping, Bed block, cills, bands and the like including weathering, slightly rounded or chamfered angles and throating including formwork [straight or curved] complete all as specified and directed.
M & L for two coats of synthetic enamel paint over one coat of pink primer to newly untreated wooden surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
M & L for two coats of Synthetic Enamel paint over one coat of Red Oxide / Zinc Chrome Primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
M & L for one coat of synthetic enamel paint on old painted steel surfaces of any description not other wise described over 10 cm width or girth including necessary preparation of surfaces complete all as specified and directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment at points of contact of wood work by chemical emulsion [in oil or kerosene based solution] @ 0.5 litre per hole by drilling 6 mm dia holes at a downward angle of 45 degrees at 150 mm centre to centre and sealing the same complete all as specified and as directed.
S & F in repairs Steel rolling shutters, thickness of laths of 1.25 mm, with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, Gear Operated type gear operated type with bevel gear box and crank handle complete all as specified and as directed.
M & L for two coats of Aluminium paint over one coat of metal Primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris to a distance not exceeding 1.50 KM complete all as specified and as directed.
Demolition of Unreinforced Cement Concrete in ground floors and Pavings not exceeding 15cm thick [below or above ground level] and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for 25 mm thick PCC 1:2:4, Type B-1 using 20 mm graded aggregate as in sub base/ levelling course for flooring, surface finished fair and even complete all as specified and as directed.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, of size exceeding 0.18 Sq.m and not exceeding 0.38 Sq.m, 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
M & L for Glazed Ceramic Tiles, Coloured, of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 8 mm thick [Square or Rectangular] as in Vertical Surfaces such as Skirting, Dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat of 10mm thick in cement mortar 1:3 complete all as specified and as directed.
M & L for 2mm thick Antistatic flooring mat as per BS: 2050/ 1978 specifications ocean blue shade laid on floor using approved quality adhesive and provision of copper grid of size 1.0mx1.0m using fine quality copper strip of size 25x3mm duly connecting the strip to earthing of the building for proper electrostatic discharge complete all as specified and as directed by Engineer-in-Charge.
M & L for 20 to 25mm thick machine cut Kota stone slab flooring, cut to required sizes/ design / pattern as directed including forming of diagonals, inlays, borders, margins in two or more shades of slabs, set and jointed with grey cement slurry mixed with a admixture of pigment to match shade of slab, laid over and including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 including rubbing and polishing to smooth mirror finish complete all as specified and as directed.
M & L for 75mm thick, PCC 1:3:6, Type C-1, using 20mm graded aggregate as in Plinth protection etc surface finished even and smooth with out using extra cement and providing 12mm thick joints for full depth of PCC at every 3.00 m and every change of direction duly filled with mastic filling comprising of 01 Part of heated bitumen blown grade of any penetration and 3 parts of sand [all by weight] complete all as specified and as directed.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces, etc., including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for providing Precast Cement Concrete Louvers and Jallies, Type, B0, 1:2:4, using 12.5mm Graded Aggregate, 50mm thick [measured solid], including all mouldings but excluding frame, set in Cement Mortar 1:4 including demolition of existing Jallies of any description and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
Dismantling of Mild Steel or Wrought Iron Work of any description not otherwise provided for complete all as specified and as directed.
S & F Mild Steel work confirming to Fe - 290, Grade E-165, as in framed work such as Grills, Gratings, Ladders etc with ends of bars shouldered and/or riveted, or forged into spikes, framed Guard Bars, Barred Iron Doors, Ladders, framed Balusters, Walk Ways, Railings, framework of Water Tanks and similar work complete all as specified and as directed.
Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
M & L for 15mm thick rendering in Cement Mortar 1:6 on stone masonry surfaces or surfaces other than fair faces of brick work or on one side of lathing, finished even and smooth without using extra cement complete all as specified and as directed.
M & L for 15mm thick rendering in Cement Mortar 1:4 mixed with integral water proofing compound as per manufaturer's specifications on stone masonry surfaces or surfaces other than fair faces of brick work or on concrete, finished even and fair complete all as specified and as directed. Note: Water proofing compound shall be measured and paid seperately.
M & L for two coats of Acrylic Washable Distemper over one coat of alkali resistant primer over two or more coats of Cement based Wall Care Putty duly rubbed with sand paper to obtain a smooth and undulation free surface on newly plastered wall surfaces including necessary preparation of surfaces complete all as specified and as directed.
M & L for two coats of Acrylic Washable Distemper on ceiling surfaces over one coat of alkali resistant primer over two or more coats of Cement based Wall Care Putty duly rubbed with sand paper to obtain a smooth and undulation free surface including complete removal of existing treatment of any description and necessary preparation of surfaces complete all as specified and as directed.
M & L for Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on newly plastered wall / Ceiling surfaces including necessary preparation of surfaces complete all as specified and as directed.
M & L for Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on wall/ ceiling surfaces including complete removal of existing treatment of any description and necessary preparation of surfaces complete all as specified and as directed.
M & L for Post Construction Anti-termite Treatment for soil under existing floors using emulsion @ one Litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed.
M & L for Post Construction Anti-termite Treatment by providing and injecting chemical emulsion Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 Litres per linear metre including drilling and plugging holes etc. complete all as specified and as directed.
M & L for providing Seamless Gypsum Board False Ceiling with GI frame work comprising of GI perimeter channels of 0.55 mm thick having one flange of 20 mm and another flange of 30 mm and web of 27 mm along the perimeter of the ceiling, fixed to wall with nylon sleeves and screws at 610 mm intervals, GI intermediate channels of size 45 mm X 15 mm X 0.90 mm supported with GI ceiling angles of size 25 mm X 10 mm X 0.55 mm fixed to soffits with steel expansion fasteners / GI cleats at 1220 mm intervals, ceiling section of 0.55 mm thick having knurled web of 51.5 mm and two flanges of 26 mm each with lips of 10.5 mm fixed to intermediate channel with connecting clips and in direction perpendicular to the intermediate channels at 457 mm centre to centre including fixing Gypsum Board of 12 mm thick conforming to IS – 2095 for false ceiling, fixed to ceiling section with 25 mm dry wall screws at 230 mm centers and including applying Two Coats of Plastic Emulsion Paint over a coat of Alkali Resistant Primer and also including Dismantling of Wall & Ceiling Boards [Fibre / Pulp / Insulation etc] of any description or Insulation Boards / Slabs / Blankets including cover fillets complete all as specified and as directed.
Dismantling of GI Sheets [plain or Corrugated] as in roof covering including ridges, hips, valleys and flashings complete all as specified and as directed.
S & F pre-painted Galvalume steel sheets of Trapezoidal profile having pitch 190mm, depth 29mm or Tiled Profile and thickness 0.50mm [Galvalume base-PPGL trapezoidal profile sheets], having tensile strength of 550 Mpa, fixed with aluminium self tapping screws, neoprene and EPDM washers of suitable size in roof covering complete all as specified and as directed. Note: Overlap shall be provided as specified by the manufacturer.
S & F pre-painted Galvalume steel Plain Sheets and thickness 0.50mm [Galvalume base-PPGL Sheets], having tensile strength of 550 Mpa, in ridges, hips, valley gutters, drip and straight flashing cut to length & bent to shape, girth sheets fixed with aluminium self tapping screws and neoprene and EPDM washers of suitable size in roof covering / cladding / eves trim / rake trim and closure trim / valley rain water gutter/ down spouts and top rafters etc. complete all as specified.
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 KG per Sq.m, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m and finished with a coat of bituminous aluminium paint @ 100 grams per Sq.m on top for water proofing treatment complete including taking down existing Roof Treatment of any description and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
Supply only integral water proofing compound [ISI marked] of approved make.
S & F 16 mm outer diameter CPVC Pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, including taking down of existing unserviceable pipes of any description complete all as specified and as directed.
S & F 20 mm outer diameter CPVC Pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, including taking down of existing unserviceable pipes of any description complete all as specified and as directed.
S & F CPVC Pipes 25 mm outer diameter SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing including taking down of existing unserviceable pipes of any description complete all as specified and as directed.
Taking down CI / PVC SWR pipes/ eaves gutters of any dia/ size/ pattern including all fittings, heads, shoes, bends, swan-necks, etc., (measured overall as fixed along the centre line over fittings and accessories) all as specified and as directed .
S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls or laid in floors including necessary brackets, clamps complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Branch Piece, Single [Single "Y" ] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed.
S & F Rotational Moulded Polythene [HDPE] Water Tanks, Triple Layered, ISI Marked, Cylindrical & Vertical Type 1000 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete including taking down old tanks and removing to store complete all as specified and as directed.
S & F Rotational Moulded Polythene [HDPE] Water Tanks, Triple Layered, ISI Marked, Cylindrical & Vertical Type 500 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete including taking down old tanks and removing to store complete all as specified and as directed.
S & F in repairs Ball Brass Valve, 20 mm dia, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed.
S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 Mpa, 20 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.
S & F in repairs white Vitreous China Squatting Pan "Orissa Pattern" of size 580 mm X 440 mm with integral foot rests and 'P' or 'S' Trap including provision of lime concrete bedding and 10 Litres capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. including brackets and connections to pipe complete all as specified and as directed.
S & F in repairs Vitreous China Ware Wash Hand Basin, White, Flat Back of size 550 mm X 400 mm including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible Waste Pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. complete all as specified and as directed.
S & F in repairs Angle Cock, 15 mm dia, brass, Chromium Plated, fancy type, screwed down high pressure with crutch or butterfly handle for iron pipe etc. complete all as specified and as directed.
S & F in repairs Bib Taps, 15 mm dia, brass, Chromium Plated, Fancy Type, long Body with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as specified and as directed.
S & F in repairs Brass Chromium Plated Tubular Towel Rail, 20mm dia, D Type, 600 mm long between flanges complete all as specified and as directed.
S & F in repairs 125mm size Stainless Steel grating for Floor Traps complete all as specified and as directed.
M & L for PCC 1:3:6, Type C-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.
M & L for PCC 1:2:4, Type B-1 [using 20 mm graded granite stone aggregate] in surface channels and drains including forming fair finished drain or channel of any inner girth using extra cement including forms, moulds, mitred / stooped ends complete all as specified and as directed.
M & L for 150 mm thick, PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in sub base for Floors/ hard standings, finished even and fair complete all as specified and as directed.
M & L for Sand Filling under floors/ pvaer blocks including watering and consolidation complete all as specified and as directed.
M & L for Inter Locking Paving Blocks of 80mm thick, made with M40 Grade cement concrete using 20 mm graded stone aggregate, Hydraulically pressed of approved colour and pattern, shape and size conforming to IS - 15658 complete all as specified and as directed.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch including taking down carefully existing point wiring of any description and cutting chasing for concealed wiring as required and making good the disturbed surfaces all as per existing complete all as specified and as directed.
All as per Serial Item No. 84 above but One flood light / Air circulator fan point controlled by one switch with 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
All as per Serial Item No. 84 above but One light point controlled by 2 Nos. of 2 way switches complete all as specified and as directed.
All as per Serial Item No. 84 above but One 3 Pin Socket Outlet 5 Amps on Independent Board complete all as specified and as directed.
All as per Serial Item No. 84 above but for One 3 pin Socket Outlet 5 Amps on the Same Board with other switches complete all as specified and as directed.
All as per Serial Item No. 84 above but one 15 Amps power point on independent board, with 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
S & F Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, Two Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Socket Outlet, 3 Pin, 6 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed.
S & F Socket Outlet, 3 pin, 16 Amps and 3 pin, 5 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
S & F Switch Modular type, one module, Single pole, one way, 16 Amps, 230 Volts complete all as specified and as directed.
S & F Electronic Fan Regulator, Stepped Type, Modular Type, Two Module, 120 W, AC, 230 Volts, Single Pole complete all as specified and as directed.
S & F Ceiling Rose, PVC body, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed.
M & L for Sub main wiring with 4 runs of single core 10 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLSH Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 10 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLSH Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 5 runs of 10 Sq.mm PVC insulated coper conductor cable & one run of 32 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLSH Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLSH Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 6 Sq.mm PVC insulated coper conductor cable & one run of 20 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 2 runs of single core 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLSH Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLSH Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 4 Sq.mm PVC insulated coper conductor cable & one run of 20 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 4 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLSH Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLSH Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 5 runs of 2.5 Sq.mm PVC insulated coper conductor cable & one run of 25 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLSH Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLSH Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 2.5 Sq.mm PVC insulated coper conductor cable & one run of 20 mm dia PVC Conduit will be measured as one unit
S & F in repairs TP&N Enclosure with 3 Pole and Earth Metal Plug & Socket, with and including One MCB, TP, 32 Amps, 415 Volts complete all as specified and as directed.
S & F in repairs SP&N Enclosure with 2 Pole and Earth Metal Plug & Socket, with and including One MCB, SP&N/ DP, 20 Amps, 240 Volts complete all as specified and as directed.
S & F in repairs MCB DB, SPN, 12 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall including making good disturbed surfaces complete all as specified and as directed.
S & F in repairs MCB DB, TPN, 4 Way, 415 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall including making good disturbed surfaces complete all as specified and as directed.
S & F in repairs MCCB DB, VTPN, 8 Way, 415 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCCBs /MCBs flush mounted with wall including making good disturbed surfaces complete all as specified and as directed.
S & F in repairs MCB, SPN, 40 to 63 Amps, 10 KA, 'C' Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F in repairs MCB, SP, 6 to 32 Amps, 10 KA, 'C' Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F in repairs MCB, FP, 40 to 63 Amps, 10 KA, 'C' Curve, AC, 415 Volts, 50 Hz complete all as specified and as directed.
S & F MCCB, FP, 125 Amps, 16 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
S & F Energy efficient Sleek LED Mirror Light Fitting of not less than 700 Lumens, Surface / Recess mounted with Acrylic / PMMA diffuser for soft glare free light with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down of existing light fittings complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Recess mounted Energy efficient LED Ceiling Light fitting, 36/40 W capacity, 230 Volts, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser, of size 600mm X 600mm, suitable for fixing in 2 X 2 Grid False Ceiling including necessary cutting to existing false ceiling and making good disturbed surfaces and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down of existing light fittings complete all as specified and as directed. Note: Light fitting shall be of PF>0.90
S & F Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 1800 Lumens output, 5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down of existing light fittings complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Energy efficient Sleek LED Mirror Light Fitting of not less than 900 Lumens, Surface / Recess mounted with Acrylic / PMMA diffuser for soft glare free light with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down of existing light fittings complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Energy efficient LED Flood Light fitting, of not less than 6000 Lumens output, 5700 K, with Pressure Die Cast Aluminium Housing, IP65 Protection, Heat resistant Toughened Glass Cover, high power LEDs as light source, electronic driver and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down of existing light fittings complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
Taking down existing flood light fittings of any description and in any position including refxing the same in old or new loacation with new bracket, bolts, nuts, washers, etc. and provision of three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
M & L for Taking down Ceiling Fan/ Exaust fan/ Air circulator fan/ pedestal fan of any description from its position and refixing the same after repairs to buildings, at same place or at new place including overhauling/ servicing, cleaning, greasing and replacement of Spares such as Bearings, Shaft Bushes, Capacitor, Cotter Pin, Clamps, Rubber Bushes, Nuts & Bolts etc. as required and spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler, connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and directed.
S & F Energy efficient & Long life Building Security Light Luminaire, of not less than 4500 Lumens output, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down of existing light fittings complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
M & L for Point Wiring for Flame Proof Fixtures / Fittings complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including ERW Steel Conduit 20 mm dia, Medium Grade, ISI Marked including all accessories on Walls / Roofs / Floors / Ceiling etc. including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / 3 Pin Socket controlled by One Flame Proof Rotary Type Switch complete all as specified.
S & F Switch Flame Proof rotary type with Termination Box in LM6, upto 16A, Single Pole, 240 Volts complete all as specified and as directed.
S & F CMRI certified Flame proof LED Tube Light Fitting of not less than 2000 Lumens output, 5700 K, with Pressure Die Cast Aluminium Housing, IP65 Protection, Heat resistant Toughened Glass Cover, electronic driver, all accessories internally prewired and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 4 Core, 16 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down of existing cables complete all as specified and as directed.
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 35 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down of existing cables complete all as specified and as directed.
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 50 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down of existing cables complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and depth not exceeding 1.5m and getting out in hard / dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Removal of excavated material [Soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M & L for Dry River Sand cushioning over and around the cable for cable protection in trenches, levelled and punned down complete all as specified and as directed. Note: The punned down thickness shall be measured for payment.
Supplying and laying un–reinforced Precast Concrete Cable Cover, Class LV, Type 1, Flat, of size 250mm x 150mm x 40mm complete all as specified and as directed.
Supplying and laying GI pipe, 50mm dia, Light grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps including taking down of existing unserviceable GI pipe complete all as specified and as directed.
M & L for Cutting Bituminous Road / Hardstanding etc. as required for Jointing / Laying Cables and Pipeline of width not exceeding 300mm and depth not exceeding 600mm and refilling after laying and making good with PCC 1:2:4, Type B1 using 20mm graded stone aggregate, 100mm thick complete all as specified and as directed.
Taking down/ up existing 20mm x 3mm size earth continuity condutor of any description and from any position and relaying the same in trenches or refixing on walls with new batten or recess fixed, including provision of necessary insulators as required at site, connecting up and testing complete as in loop earthing all as specified and as directed.
Supply and fixing Rigid non-metallic PVC conduit of 20mm dia including junction boxes, all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. including taking down of existing unserviceable PVC pipe complete all as specified and as directed.
S & F Telephone Socket / Jack with Shutter, RJ-11, Modular Type, One Module including suitable Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet, Modular type Base / Grid Frame & Cover Frame complete all as specified and as directed.
Supplying and laying GI pipe, 40mm dia, light grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps including taking down of existing unserviceable GI pipe complete all as specified and as directed.
M & L for Earthing complete with Copper Earth Plate Electrode 600 X 600 X 3.15 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to Copper Strip of size 20 X 3mm [Earth Lead] and GI pipe 40 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
S & F in repairs Single Pointed Air Termination Aluminium Rod, 12 mm dia and 300 mm long including necessary fasteners fixed for Lighting Protection with necessary connections to earthing etc complete all as specified and as directed.
S & F in repairs Aluminium Strip of size 25 X 3.15 mm, fixed to walls / columns / beams etc with Saddles or porcelain blocks of 10mm thick spaced at 1.00m centre to centre including making grooves and fixing with brass screws etc. for roof conductors and down conductors above ground complete all as specified and as directed. Note: Hylam sheet block shall be in two pieces each 10mm thick, one fixed to base with brass screws and the other fixed over it with brass screws after fixing aluminium strip in the groove provided.
S & F in repairs Earth continuity Conductor or main earthing lead made of GI Strip of size 32 X 6mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
S & F in repairs Test Point Terminal Box of size 200 X 100 X 100mm made out of 2mm thick hot dip galvanised sheet, drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with Test Point Terminal Block made of Gun Metal or Phosphorus Bronze of size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and as directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
SAI KRISHNA ASSOCIATES
S A R CONSTRUCTIONS
M/s SIRI CONSTRUCTIONS
Pavan Commercial Company
Ruchira Associates
SUVEDAM CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .