| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | L1 | Accepted-AOC The lowest bidder | |
| 2 | L2₹13.6 L+₹12,697.10 (0.94%)Rejected-Finance GOALAPARA MONIRAMPUR PO BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700 120 WB | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L2 | Rejected-Finance Other than the lowest bidder | |
| 3 | L3₹13.6 L+₹14,707.10 (1.09%)Rejected-Finance 106 1 RAJA RAMMOHAN SARANI KOLKATA 700 009 | KOLKATA | WEST BENGAL | 700009 | L3 | Rejected-Finance Other than the lowest bidder | |
| 4 | L4₹14.6 L+₹1.1 L (8.38%)Rejected-Finance | L4 | Rejected-Finance Other than the lowest bidder | |
| 5 | L5₹14.9 L+₹1.5 L (10.8%)Rejected-Finance 20 NO TIKIA MAHAL ORDERLY BAZAR BARRACKPORE DIST 24 PARGANAS NORTH STATE WEST BENGAL PIN 700 120 | BARRACKPORE | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L5 | Rejected-Finance Other than the lowest bidder |
Tender Value
Refer Docs
EMD Value
₹37,000
Closing Date
3 Oct 2020, 6:00 pmClosed
CWE(S) BARRACKPORE
CWE(S) BARRACKPORE,PO-BARRACKPORE, DIST-24 PGNS(N) KOLKATA,PIN-700120(W.B)
SPECIAL REPAIR TO BATHROOM AND TOILETS FOR TILING, ELECTRIC WIRING, PLUMBING, FALSE CEILING AND FLOORING IN BLDG NO 20 AT BARRACKPORE UNDER GE BARRACKPORE
2020_MES_375133_1
CWE/BKP/20 OF 2020-2021
Open Tender
Miscellaneous Works
Item Rate
180 days
GE BARRACKPORE
Class E and Cat a (i)
5 documents required · 5 mandatory
₹500
GE BARRACKPORE
₹37,000
Yes
3 Nov 2020
5 Sept 2020
5 Oct 2020
5 Sept 2020
3 Oct 2020
19 Sept 2020
Amount
B/R PORTION Demolition of cement concrete (unreinforcement) as in ground floors or paving n. exc 15cm thick below or above ground level complete.
Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing) removing unserviceable tiles to the low lying areas of defence land stone and rubbish off the premises.
S&F for colour glzaed tiles in vertical surfaces (450x300x7)mm thick set jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick cement mortar (1:4) complete all as specified and as directed.
S&F for joint free non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20 mm thick screed bed in cement mortar (1:6) complete all as specified and as directed
M&L Chequered cement concrete tiles 30cm x 30cm x 25mm thick with grey cement and pigment set, jointed & pointed in neat cement slurry in floors with glossy finish over 20mm thick screed in CM(1:6) complete all as specified and directed.
Demolition of Brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework & precast concrete articles complete all as specified and directed.
M&L for Brick work with sub class ‘B’ bricks straight or curved on plan exc. 6 Mtr mean radius built in cement mortar (1:6) all as specified and directed.
M&L for Brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) all as specified and directed.
All as per Srl item No 7 here-in-before but except bricks. Note:- Serviceable old bricks shall be obtained from srl item No 6 hre-in-before for reusing.
Taking down of cement plaster incl hacking out of joints, hacking for key, scrubbing down with water etc
M&L for 15mm thick rendering in cement mortar 1:6 on fair faces of concrete surfaces finished fair and smooth without using extra cement.
M&L for 15mm thick rendering in cement mortar 1:4 mixed with water proofing compound when necessary @ 3% all as directed. Note : WPC will be measured and paid separately
Supply only Liquid water proofing compound.
M & L for preparation of old / new Distempered surfaces of walls by washing, rubbing down, stopping nail holes, filling cracks with putty etc and applying two coats of oil bound distemper including one coat of primer on plastered surfaces complete all as specified.
M&L for two coats of cement base paint over one coat of primer including preparation of newly plastered surfaces complete all as specified
Taking down Chowkhats with shutter or frame wooden / PVC or Aluminum exc 1.5 sqm but n.exc 4 sqm each and re-fixing in same opening or all as specified.
Taking down Chowkhats with shutter or frame wooden / PVC or Aluminum n.exc 1.5 sqm each and re-fixing in same opening or all as specified.
Taking down Chowkhats with shutters of or frame exc. 1.5 sqm but n.exc 4 sqm. any description (without taking off shutters from the frame) removing to or from store or all as specified.
Taking down chowkats or frames n.exc 1.5 Sqm each but (without taking off shutters from the frame ) removing to or from store.
S&F Solid PVC Door Frame of size 50 mm X 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing.
S&F Factory made solid PVC door shutter 30mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying and fixing in the frame at site as per specification & drawing including necessary Aluminum fitting all as specified.
S&F for Plain Aluminum sheeting Alloy 31000 H4 in stepped flashing 0.56 mm thick fixed with door/window or all as specified and directed by Engr-in-Charge.
Taking down shutter only. exc 1.00 Sqm and n.exc 2 sq.m each and removal to or from stores.
Cutting holes into or through brick walls built in cement mortar or stone walls built in lime or cement mortar to a depth of embedded portion exc one brick but n exc two brick for inserting hold fast etc and making good dismantled portioin with cement concerete 1:2:4 type B1 all as specified.
S&F MS hold fast or Fan hook of flat iron 25 mm X 6 mm or all as specified.
Preparing surfaces of steel, Treating small articles sutch as hold fast back of chowkats, etc are n.exc 0.1 sqm each
Dismantling wrought iron or mild steel work of any description not otherwise specifically provided for.
S&F framed work such as grills, gratings,etc.with end of bars shouldered and/ or riveted, or forged into spikes; framed guard bars ; barred iron doors; ladders; framed work of water tanks and similiar work confirming to FE.290.gde-E-165 Steel bar as in frame work sutch as grill gratings and guard bars and similar works.
M&L preparing surfaces of wood and wood based materials, steel and iron work, new or old of any description and grith not described , and treated with tar or coal tar black paint.
S&F for Aluminum anodised barrel tower bolts of extruded section and fixed. 150 mm long all as specified and directed.
S&F for Aluminum anodised barrel tower bolts of extruded section and fixed. 200 mm long all as specified and directed.
S&F For 100 mm butt hinges medium weight cold rolled mild steel, and fixed complete all as specified and directed.
S&F For 150mm long aluminum handles, fabricated type, anodised all as specified and directed.
S&F in repair for aluminium alloy anodised ,sliding door bolt 250 mm long with hasp staples (bolt type) and fixing clip of sheet , cast or extruded section and fixing bolt and sliding bolt of extruded sections or cast alluminium alloy and fixed.
M&L preparation of old surfaces of wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint all as specified.
M&L preparation of new surfaces of steel any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer all as specified.
M&L 75 mm thick cement concrete type C-2, 1:3:6 (40mm graded Aggregate) as in plinth potection or all as specified. Finished cement concrete surfaces even and smooth without using extra cement all as specified and directed.
M&L for Cement concrete in surfaces channels and drains type C2 1:3:6 ( 40 mm graded aggregate) or all as specified.
Forming construction joint 30 mm deep x 10 mm wide filled with 1:3 bitumen and sand
M&L Providing cement concrete type C1 1:3:6 (using 20mm graded stone aggregate) as in coping or specified.
M&L 100 mm thick cement concrete type D-2, 1:4:8 (40mm graded Aggregate) as in sub base or all as specified and directed by Engr-in-charge.
M&L for 25 mm thick Cement Concrete type B-1, 1:2:4 (using 20 mm graded aggregate) as in floor/pavings etc complete all as specified by Engr-in-Charge.
S&F in repair stainless steel wire cloth 0.36 mm nominal dia. of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or stainless stel wire staples including wooden fillet fixed with wire mesh and frame.
S& F in repair Vitreous china squatting pan , 'orissa' pattern, size (580 X 440) mm white, with integral foot rests (excluding flushing cistern and flush pipe ) including connection to trap, and to flushing pipe ,antisyphonage pipe, etc. complete with all fittings includig making good to floor all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) in 'P' trap.
S&F PVC (SWR) in 'S' trap.
S&F For Bib tap fancy type, chromium plated CP 15mm dia of bore.
S&F CP Grating 125 mm dia with waste hole fancy type all as specified.
S&F 2nd class hard wood for plain solid straight chowkat and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joint all as specified and directed.
Cutting into existing manholes for connecting new drain making good to pipe and rendering, cutting out existing concrete 1:2:4 type B1 smooth finished and reforming benching as required.
S&F in repair of PVC valveless, syphonic action type flushing cistern low level, white, with inlet, ball valve, float and handle incl brackets capacity 10 ltrs and connection to pipe complete fancy type all as directed.
Taking down cast iron pipes/ PVC pipe including fittings by burning out lead joints etc to facilitate dismantling old serviceable fittings/pipe laid in trenches floors or fixed to walls all as directed including earth work and demoltion of PCC/Brick work and making good to match with existing surfaces
All as per Srl item No 53 here-in-before but 80/75 mm bore of pipe
S&F PVC (SWR) 110 mm dia pipes single socketed in any length with rubber ring joints laid in trenches or in floors or fixed to walls or all as specified.
All as per Srl item No 55 here-in-before but 75 mm bore of pipe
M&L for GI Tubes 15mm medium grade, galvanised, with all fitting and fixed complete to walls and ceilings concealed type or laid in floors including taking up or down old tube allas directed.
All as per Srl item No 57 here-in-before but 20 mm bore GI tubing
All as per Srl item No 57 here-in-before but 25 mm bore GI tubing
S & F in repairs Stop valve chromium plated ,screwed down, high pressure fancy type chromium plated and fixed, all as specified.
S & F in repairs Angle Stop valve Chromium plated , screwed down, high pressure fancy type long shank and cup (concealed type) 15 mm bore and fixed, all as specified.
S&F for PVC connection 15mm dia 450mm long with 02 Nos brass check nuts with washer etc complete all as .
Disconnecting existing water tanks, setting aside (or lowering if required ) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. ( Cleaning repairing, etc. measured separately) 1000 Ltr or all as specified.
Dismantling water tanks, capacity exc 500 & nexc 1000 Ltr and all as directed.
S&F rotational moulded polythylene water storage tanks(1000 Ltr) (Cylindrical vertical with closed top) hoisted and fixed in position all as specified
S&F in repair gun metal, globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed (20mm)
S&F Ball brass valves high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule/ Pvc pipe and fixed (25mm dia).
S & F in repair PVC (SWR) Floor trap plain with grating including jointing with solvent cement and removing old trap and making good all as.
S&F in repairs viterous china wash basin, white or colour flat back Pedestal type including all fittings size 630 mm x 450 mm including brackets with waste pipe, including cutting for and pinning in ends of brackets or erecting stand with making good, fancy type complete all as specified.
S&F for Pillar Taps, cast copper alloy, Fancy type, chromium plated screwed, down high pressure with or without lettered Hot or cold with long screwed shanks and flynuts, screwed for iron pipe and fixed all as specified.
S&F in repair waste fittings brass chromium plated for glazed ware basins, etc with long screwed shanks and flynuts, flange end bedded in red lead cement and other end fixed 32 mm dia.
Forming jambs, etc. to openings (to foregoing items) including cutting, toothing and properly bonding into old work also facing, jointing and pointing to match existing work, complete cement mortar 1:6
S&F PVC (SWR) bends any radius 75mm bore with access door all as specified.
All as per item No-73 above but 110mm bore.
S&F For PVC bend 110mm dia
All as per item No-75 above but 75 mm bore.
S&F PVC (SWR) branch piece, single (Single Y) /(Double Y) equal or unequal 75mm bore with access door.
All as per item No-77 above but 110mm bore.
S&F PVC (SWR) junctioin single (Single T ) equal or unequal 75mm bore with access door.
All as per item No-79 above but 110mm bore.
S&F for PVC (SWR) Vent cowl 110mm bore
S&F for PVC (SWR) Vent cowl 75 mm bore
S&F Chromium plated towel ring screwed down fixing to walls with screws complete.
S& fixed Chromium plated Towel rail 20 mm dia, D type 60 cm long between flanges of all as specified.
Demolition of Reinforced cement concrete in ground floors and paving n.exc 15 cm thickness (below or above ground floors) (Reinforcement cut as required to facilitate demolition) cement concrete or all as specified and directed by Engr-in-Charge.
Form work to the soffits of suspended slabs such as roof slabs, floor slabs, landing and similar works : not exceeding 200 mm thick (Horizontal or slopping) and making flat rough finished surfaces of concrete.
M&L Providing Reinforced cement concrete 1:2:4 Type B-1,(using 20 mm graded aggregate), as in shelves and the like, all as specified and directed by Engr-in-Charge.
M&L TMT bars 10 mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9 mm dia or securing with clips.
All as per item No. 88, but 6 to 8 mm dia for stirrups.
M&L vitreous china urinals, (back or corner wall type) complete including providing and fixing Partition wall with plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets flush pipe, CP Grating and Union for discharge pipe (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe fancy type make approved by GE all as specified.
M&L for 10mm thick rendering in cement mortar 1:4 on fair faces of concrete/ brick surfaces finished fair and smooth without using extra cement.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nanital or similar pattern roof coverings.
M&L Pre-Painted Galvalume aluminum zinc coating aluminium corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering/ cladding to wall fixed with 'J' and washers or screws all as specified and directed.
M&L Pre-Painted Galvalume aluminum zinc coating aluminium plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering/ cladding to wall fixed with 'J' and washers or screws all as specified and directed.
Taking down of Roof trusses, coupled rafters or trussed beams, for renewal of any defective members (timber renewed to be measured separately) and reassembling upto 4 mtr all as specified and directed.
Housing and fixing trusses etc. after repairs including tightening up wedges, cotters bolts etc upto 4 mtr all as specified and directed by.
Dismantling timber scantling 40 sq cm and over in section unframed work, in any position complete all As specified.
M&L 2nd class hard wood clean sawn in timber scantlings timber framed and fixed to replace old and decayed timber (including piecing, scarfing, etc, of old and new timbers if required) and removing defective portions to store complete all as specified.
M&L for Providing, cement concrete Type B0 1:2:4 (12.5 mm graded aggregate) in hold fast block,lintels upto 1.5 m clear span, cills, steps: seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, kneelers, apex stones bed plates, kerbs not provided for water trough and the like including weathering, slightly rounded for chamfered angles and throating, as directed.
S&F Prelaminated particle board 18 /19 mm thick interior grade PVC laminated one side with decorative face lamination and other side balancing white lamination fixed with screws to timber frame work as in cup board or drawer all as specified.
S&F Mortice lock Mild steel, verticle type, size 75 mm with 4 leavers fixed with shutter and chowkats all as specified.
S&F Aluminum handles, cast type anodised for cup boards 75 mm length
S&F Continuous (Piano) hinges, mild steel bright finished or electrogalvanised, width of flaps( when open) 30 mm .
S&F Ball catches with 8mm dia steel ball, catches with 8mm dia steel ball and brass body and striking plate including in and fixed
S&F Hasp and staple, aluminum anodised, safety type with hinge pin including bolt of hinge plateand fixed with screws 100 mm long all as specified.
S & F in repairs Stainless steel Curtain Rod 25 mm dia with fixing brackets,stops, etc. or all as specified.
Dismantling Battens for tiles , shingles etc, of any size including tilting fillets exc 15 cm all as specified.
M&L 2nd class hard wood plain fillets square section secured with nails for frame work, sectional area exc 13 Sq cm and n.exc 25 Sqcm in cluding taking down all as specified
M&L 2nd class hard wood clean sawn battens sectional area 30 cm centre to centre in sectional area exceeding 15 and not exceeding 25 Sqcm complete all as specified and directed..
Dismantling of wall and ceiling boards or insulation boards any thickness including cover fillets etc all as specified.
S&F 4 mm thick Fibre cement Standard ceiling board of Everest or equivalent make with false ceiling (oceanic) with powder coated exposed G.I grid suspension system (E- Grid T 2430 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span withhanger spacing of 1200 long cross Tee 1200/600 mm long and wall Angle . The wall Angle shall be fixed on pvc Dash Fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c . The main Runners to be placed @1200 mm c/c . The Cross Tee 1200mm will be inserted in the pre cut slots of Main Runner at a Regular interval of 600 mm to form a modular grid of 1200mm x600 mm .Additional cross Tee 's of 600 mm shall be placed perpendicular to the cross Tee 1200 mm long to finally from a grid of 600 mm x 600 mm. Grid ofr module of size 600 mmx600mm shall be supported by 4 mm dia G.I. wire from purlins / soffits. 4 mm thick High pressure steam cured Non Asbestos Fibre cement standard ceiling Board ( Density > 1200 kg/ cum ) of size 595mm x 595 mm , conforming IS 14862 & Type B category III of ISO 8336 , tested as per AS 1530 part - 3 & B. S - 476 part 4,5,6,7&8, should be placed in Grid module to form complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden fame or ston,concrete, or brick surrounds, glazed with putty or fixed with beads, (upto four storey building) or all as specified.
M&L sheet glass ordinery quality 3 mm thick and glazing with oil putty or wooden beads n.exc 0.50 sqm in each pane(upto four storey building) or all as specified.
M&L figured glass, Pin head type and glazing with oil putty in squares n.exc 0.5 sq.m in each pane 3 mm thick all as specified.
S&F for glazed skelton shutters 35 mm thick of 2nd class hard wood open rebated and prepared to receive glass/guage etc and rebated sash bar any number divided into squares, with plain chamfered or rounded, mitred beads for securing glass etc; sizes of members of shutters in SSR part-I,section 8,clause 8.24 (a) supplied and fixed to chowakhats complete
S&F for glazed skelton shutters 30 mm thick of 2nd class hard wood open rebated and prepared to receive glass/guage etc and rebated sash bar any number divided into squares, with plain chamfered or rounded, mitred beads for securing glass etc; sizes of members of shutters in SSR part-I,section 8,clause 8.24 (b) supplied and fixed to chowakhats complete
S&F For 2nd class hardwood 35 mm thick plain framed pannelled shutters (three panels) both sides (feather edged) or of veneered particle board medium density wood particle board with commercial face veneers supply and fitted to chowkat all as specified.
S&F for Aluminum anodised barrel tower bolts of extruded section and fixed. 100 mm long.
S&F For 75 mm butt hinges medium weight cold rolled mild steel, and fixed complete.
M&L for steel windows factory made with side hung shutters including projecting type hinges with steel handel and steel peg stay, complete without glazing bars, dovetailed or welded all as per IS 1038 all as specified and as directed.
M&L for steel ventilators top hung shutter openable type including hinges, steel peg stay complete without glazing bars, dovetailed or welded and on coat of red oxide primer etc all as specified and as directed.
M& preparation of new surfaces of wooden/ plywood surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified.
S&F in repair vitreous china wash down water closet pan (pedestal pattern)(EWC) white including plastic water closet seat cover closed pattern with flat bottom, and cover and mild steel chromium plated hinging device etccomplete all as specified and as directed.
S & F in repair health faucet chrome plated with push bottom flexible steel pipe with PVC lining of 1 mtr long suitable for 15mm pipe fancy type. As per drawing specification approved all as specified.
S&F in repair Factory made solid PVC wire gauge door shutter 30mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying and fixing in the frame at site as per specification & drawing including necessary Aluminum fitting all as specified.
E/M PORTION Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement for smooth finishing of holes,small patches etc complete all as specified and as directed.
M&L point wiring complete with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly one light point controlled by one way switch and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular box,top cover plate, blank plate,MS box,screws,washers and all modular electrical fixtures are to be used same make/brand only and shall be deemed in to included in quoted rate only.)
All as per Srl item No 128 here-in-before one fan point controlled by one switch .
All as per Srl item No 128 here-in-before one 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
All as per Srl item No 128 here-in-before one 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
All as per Srl item No 128 here-in-before but point wiring with 4 sqmm and earth conductor of size 4 sqmm one 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on independent board.
All as per Srl item No 128 here-in-before one 6 pin 6/16 amps socket point controlled by one 16 amps switch on same board .
S&F modular type switch 10 amps, single pole, 1 way, 1/2 module, 240V, ISI marked complete all as spedified and directed.
S&F modular type switch 16 amps, single pole, 1 way, 1/2 module, 240V, ISI marked complete all as spedified and directed.
S&F modular type socket shuttered type 6 amps, 2/3 pin combined 2 module, 240V, AC, ISI marked complete all as specified and directed.
S&F modular type socket shuttered type 6/16 amps, 6 pin combined 2/3 module, 240V, AC, ISI marked complete all as specified and directed.
S&F red color lighting indication lamp 6 amps, single pole, 240V, AC, 50 HZ suitable for 1/2 module ISI marked complete all as specified and directed.
S&F fan regulator modular type electronic, stepped type (01 to 4/5), 100 to 120 watts, 240V, AC, ISI marked complete all as specified and directed.
S&F angle lamp holder, PVC/poly carbonate type with back palte for batten fittings including LED lamp 10 watts complete all as specified and directed.
S&F ceiling rose, 3 terminal, PVC/polycarbonate, isolated body ISI marked, complete all as specified and directed.
S&F decorative box type 20 watt light fitting, blue coloured end caps, pre-wired, and including providing PVC/Wooden round/square block-02 Nos and connected with LED fitting to ceiling rose and removing old unserviceable fitting complete all as specified and directed. Make of light fitting: Hallonix Cat No. HLCB118T8 / Crompton Model No. DMLN1LT8-16/ Havells Order code:- REGALBATTENT8UPTO1X22WSSBSWH/ JAQUAR Product code:-LUN101X120XC or equivalent in any approved make.
S&F decorative box type 9 watt light fitting, blue coloured end caps, pre-wired for single LED lamp 9 watt and including PVC/Wooden round/square block-02 Nos and connected with LED fitting to ceiling rose and including removing old unserviceable fitting complete all as specified and directed. Make:- Crompton Model No. DMLN1LT8-8 / Surya Cat Ref: SUB 118T8 or equivalent make in Philips
S&F wall mounted decorative type surface mounted 1x6 watt LED light fitting including fixing arrangements at any hight with nuts ,screws and washers and connected to ceiling rose and including removing old unserviceable item complete all as specified and directed. Make:-Crompton cat No.LCSR-06-CD / Surya cat No.:- SLE DLS 6W XX Stellar RD / HPL product code:-HLPLEDSO6WW as approved
S&F sheet metal enclosure,AD/DD 240 volts AC,SPN,DB, 8 way, flush mounting with 100amps copper busbar,neutral bar,earth bar and MCB incomer,MCB SPN/DP, and MCB SP as outgoing for IP 43& IP54 DBs protection and including making good the disturbed surfaces to match with existing surface and colour shade all as specified and as directed. Make:- Legrand cat No.5076 21 8 Way / Hager cat ref No.VYS08G (Acrylic door)/L&T Cat ref:-DBSPN008GD or equivalent in any approved make.
S&F in repair sheet metal enclosure 2 mm thick,AD/DD 240 volts AC,SPN,DB, 4 way, flush mounting with 100amps copper busbar,neutral bar,earth bar and MCB incomer,MCB SPN/DP, and MCB SP as outgoing for IP 43& IP54 DBs protection and including making good the disturbed surfaces to match with existing surface and colour shade all as specified and as directed. Make:- Legrand cat No.5076 20 4Way (AD) / Hager Cat ref No.VYS04G(AD) /L&T Cat ref:-DBSPN004GD or equivalent in any approved make.
S&F MCB SP 6 to 32 Amps 10 KA,"C" series,AC,240Volts,50Hz , ISI marked complete all as specified and directed.
S&F MCB SPN 40 to 63 Amps 10 KA,"C" series,AC,240Volts,50Hz, ISI marked complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit ISI marked medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unserviceable submain wiring and making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
S&F aluminium busbar chamber in sheet steel enclosure of current rating capacity 100 amps, 4way, 415 volts with necessary fixing arrangements such as hole fastners/screws, bolts, nuts and wasers etc and including removing old unserviceable item from existing location and making good the disturbed surface area and complete all as specified and as directed.
M&L for Earting complete with galvanised steel earth plate electode 600mm x 600mm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode upto test point or upto 7.5 mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Part-1 and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh, including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45 x 45 x 45 cm, RCC cover (1:2:4) type B1 of size 45 x 45cm and 50 mm thick including excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as slpecified and directed.
S&F in repair ceiling fan of size 1400 mm sweep,high speed, single phase, 240Volts,AC, 50Hz, White/Brown/Bianco/Sky colour and including all accessories such as blades, down rod,nuts, bolts,washers, split pins,'S' hook with necessary suitable MS clamps and connecting cable three core 0.75 sqmm round PVC sheathed from ceiling rose to fan connector and testing complete all as specified and directed. Notes:- (i) Old ceiling Fans will be deposited by the contractor in MES store yard of AGE(E/M). (ii) Make:- Standard -Model No .SAILOR /Usha model No :- Striker /Havells model No. ES-50 / Orient model No.DELUXE (DBB) as approved.
M&L for galvanized iron tubing 40 mm dia "medium grade" in any length including embedded in wall two ends duly welded MS holdfast at two ends of GI pipe and providing PCC in wall and making good distribed surfaces complete all as specified and directed.
M & L for under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 25 sqmm 4.00 core including disconnectiung and taking out of existing LT cable of any type and size complete all as specified and directed. Notes : (i) Earth work shall be measured and paid separately under relevant item. (ii) Sand cushioning, brick for cable protection, GI pipe, etc shall be measured and paid separately under relevant items.
Excavation in trenches for laying under ground cable, errection of poles and stays in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed by Engr–in–charge.
Supply and laying sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable ) and gently punned down to 18cm thickness complete all as specified and directed. (Note : Punned thickness will be measured for payment.)
Supply and laying sub class B bricks locally available of size 25 x 12.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr in charge.
Removing surplus excavated material to a distance not exceeding 50 meter above the starting point complete all as specified and directed by Engr in charge.
S&F GI bracket pipe of size 40 mm dia medium grade of 1.2 mtr long bent to shape hot or cold suitable for street light fitting and making one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixed on PCC & Steel poles/on wall surfaces and including suitable MS flat iron clamps of 30 x 6 mm thick -02 Nos suitable for fixing any place of poles with nuts, bolts & wahsers including grouting on wall etc and including removing of old unserviceable item complete all as specified and directed.
S&F LED security light fitting of capacity 70 to 75 watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protection with 4 KV inbuilt surge protector and cable connection from looping box to light fitting and testing and including removing of old unserviceable item complete all as specified and directed. Make:- Jaquar cat No. LSRTO1S072XW/HALONIX Cat No.HLSLD-10-72-CWL-I/ Crompton cat No. LSTP-72-CDL/ Bajaj cat No. BRTFG 75W LED I as approved
JADAV CONSTRUCTION
M/S H.P Singha
BHUPENDRA LAL CHAKRABORTY
BARRACKPORE ENTERPRISE
SAI ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .