| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹14.2 L+₹10,178.20 (0.72%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹15.6 L+₹1.5 L (10.7%)Rejected-Finance H NO 03 TULSI BAGH SRINAGAR J K 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹16.3 L+₹2.2 L (15.3%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹16.9 L+₹2.8 L (19.8%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹16.3 L
EMD Value
₹32,500
Closing Date
4 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE KARGIL
MES OFFICE KARGIL
SPL REPAIR TO BLDG NO T-42 SM OFFICE AND WT STORE AND PROVN OF 02 X SOAKAGE WELL OF CK HOUSE AND 01 X SEPTIC TANK AT DRAS STATION UNDER GE KARGIL
2023_MES_573777_1
GE/K-53/2022-23
Open Tender
Civil Works
Item Rate
180 days
DRAS
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE KARGIL
₹32,500
Yes
25 Mar 2023
7 Jan 2023
6 Feb 2023
7 Jan 2023
4 Feb 2023
21 Jan 2023
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level )and removing unserviceable material outside cantt area.
M&L PCC type B0 1:2:4(12.5mm graded aggregate) 25mm thick as in sub base floor to receive tile/ Kota stone all as specified.
M&L machine cut Kota stone slab flooring 20-25mm thick, over cement screed bed or bedding layer of cement mortar 20mm thick in CM 1:4 for laying floor finishes base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M&L for Non Skid ceramic tiles7 to 8 mm thick area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete over 15 mm screed bed in CM 1:6 all as specified and as directed by engr in charge.
Dismantling of plain or corrugated CGI/PGI steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed
S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F for Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F 0.63mm thick, galvanised, corrugated mild steel sheeting with two corrugations side lap, here-in-before but except sheet fixed with L-type or J-type or crancked hook bolts and washers as in roofs, walls etc,in lieu of screw complete all as specified and directed.
S & F 2mm thick fibre glass reinforced translucent corruggated sheeting with two corrugations side lap fixed with with self tapping screw or L-type or J-type or cranked hook bolts as in roof, wall etc complete all as specified and as directed
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/blankets, any thickness, including cover fillets all as specified and as directed by Engr-in-Charge.
S&F, 12 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame work complete, all as specified and directed
S&F, 9 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber rame work complete, all as specified and directed
M&L for Plain fillets of second class soft wood (KAIL), sectional area exceeding 13 Sqcm but not exceeding 25 Sqcm in square, rectangular or traingular in section, clean sawn secured with nails or brads incl dismantling of fillets complete all as specified and directed
M&L for fillets of second class soft wood (KAIL), sectional area not exceeding 3 Sqcm in section, bullnosed, splayed, chamfered or rounded on one edge or face secured with nails or brads complete all as specified and directed
M&L for side cornice fillets of second class soft wood (KAIL), sectional area exceeding 3 Sqcm but not exceeding 6 Sqcm in section, bullnosed, splayed, chamfered or rounded fixed with nails to timber frame work incl dismantling of fillets complete all as specified and directed
Taking down chowkats or frames exc 1.5 Sqm but n.exc 4 sqm each with shutter/without taking of shutters from the frames.
S&F 2nd class soft wood Plain, solid straight chowkhats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints all as specified &directed.
Taking down shutters but exc 2 Sqm each and removing to or from store as specified.
S&F 2nd class soft wood 35 mm thick Plain, framed panelled shutters (any No of panels), with panel of timber flat on both side or veenered particle board medium density, wood particle board with commercial face veneers fitted to chowkats all as specified.
S&F 100mm but hinges medium weight cold rolled mild steel fixed with screws or welded all as directed.
S&F 150mm long Aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and as directed
S&F Aluminium handles cast type anodised size 125mm complete all as specified.
S&F 250 mm Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed
Hacking out broken glass (any thickness from metal frame including punching or drilling out glazing) not exceeding 0.50 sqm
S&F 3mm thick glass pan ordinary quality and glazing with oil putty in square n exc 0.5 Sqm in each pane.
M&L for preparation of New surface of wood and wood based material surface of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed
M&L for prepration of old painted surface of wood and wood based material and one coat of synthetic enamel paint of any description, not otherwise described over 10cm width or girth complete all as specified and as directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified
S&F Rolled mild steel Gde Fe-410 W (Gde E-250) quality B as in Roof trusses (framed), trussed, purlins crane gantries, rails & fastenings & heavy brackets framimg (Beam, tee, angle, channel or flat section) including distance pieces, cleats etc complete all as specified
M&L for preparation of new steel and iron surfaces of any description , not otherwise described ,over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as speciified and as directed
M&L for preparation of old steel and iron surfaces of any description , not otherwise described ,over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as speciified and as directed
Demolition of Brickwork or stone/boulder masonry built in cement mortar or cement lime mortar all as speciified and as directed.
Surface dressing n-exc 15 cm deep and getting out in hard/dense soil.
Excavation in trenches n.exc 1.5M wide and n.exc 1.5M depth in foundation,shafts,wells cesspits,manholes etc n.exc 10sqm on plan and n.exc 1.50m in depth and getting out in hard/dense soil directed by Engr-in-Charge.
Excavating over areas, n exc 4.5 m deep and getting out in Hard and dence soil complete all as directed by Engr-in-Charge.
M&L PCC type D-2 1 :4 : 8 (40mm graded agg) in foundation, filling and mass concrete.
M&L Cement concrete 1:2:4 type B 2 in surface channels and Drain.
M&L for stone walling of random rubble,uncoursed,well bonded,laid dry in retaining walls,abutments and similar work complete all as specified and directed by Engr-in-charge.
M&L for Precast cement concrete Type C1 ,(1:3:6) (using 20mm graded crushed stone agg) block masonary with solid blocks exc 10cm in width and setting in CM 1:6, complete all as specified and directed by Engr-in charge.
M & L for taking down cement plaster on brick or stone wall etc indliding raking out joints, hackiong for key, and scrubing down with water and all as specified by engr in charge.
M&L 15 mm thick cement plaster on concrete surface in cement mortar (1:4) finished even and smooth without using extra cement complete all.
M&L for reinforcement cement concrete (nominal mix) type A1 (1:1.5:3) (using 20mm graded crushed stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and like etc .complete all as specified and directed by Engr-in-Charge.
M&L for precast cement concrete Type B-1 1:2:4 (20 mm graded aggregate) as in cover slabs (for man holes etc.) water troughs, shelves and similar articles with plain frames set in CM1:4 ,all as specified and directed.
S&F mild steel TMT bars 10mm dia and over cut to length bent to shape required incl cranking bending spirally for hooping etc and binding with mild steel rie (annealed) not less than 0.9 mm dia or secjring with clips.
M&L Loose filling of broken brick with aggregates of gauge 40 to 80 mm in soakage pits, soakage wells
S&F 150mm bore reinforced concrete pipes, class NP2, laid and jointed complete with collars as speciied.
PCC 1:3:6 type C2 concrete bed to drain pipe 150mm bore including packing under and hunching against the sides of pipes after they are laid and tested all as specified.
M&L PCC (1:2:4) type B-1 (20 mm graded aggregate) as in coping and the like including weathring, slightly rounded or chamfered angles and throating as directed including fromwork etc, complete all as specified and as directed.
M&L for forming fair finishes drain or channel 30 cm inner girth in cement concrete using extra cement all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
Returning, filling incl spreading, levlling, watering and well ramming in each layer n.exc 25 cm in soft/loose soil
Removing excavated material not exc 50 m and deposited where directed
Cutting of 150mm internal dia into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel(1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required,
S&F LLDPE Septic tank of minimum capacity 10000 ltr designed to carry sewage and sullage water including excavation in hard/dense etc, complete with upflow filter including media all as per manufacture instruction complete all as specified and directed. Make : Sintex or equivalent.
M&L for preparation of newly plastred surfaces of walls and applying two coats of cement base paint over a coat of primer.
M&L for preparation of newly plastred surfaces of walls and applying three coats of white wash.
M&L for PCC Type C-2 1:3:6( 40 mm graded aggregate) 75mm thick as in plinth protection/sub base/paving complete, fair and even and smooth without using extra cement all as specified and as directed.
Taking down carefully copper or aluminium point wiring (light, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc.
M&L for Point wiring with multi-stranded copper conductor PVC insulated and unsheathed cable in PVC casing and capping, 1.5 Sqmm with all fittings/accessories and including 1.5 Sqmm PVC insulated copper earth wire connected to common earth including closed recessed wooden terminal Boxes of suitable size made of 2nd class hard wood for mounting switches, sockets etc with 3mm thick laminated sheet cover for one light point or bell/buzzer point controlled by one switch, complete.
All as per Srl item No 60.00 here in before but for one 3 pin socket outlet 5 Amps on independent board.
All as per Srl item No 60.00 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 15 Amps independent board.
S & F Switch piano flush type 5 Amps, single pole one way.
S & F Switch socket combination 2 in 1, and 3 and 2 pin, 5 Amps flush type.
S & F Switch socket combination 2 in 1, 5 and 15 Amps flush type.
Supply and fixing in LED 1x18 Watt, 220 V, AC decorative box type with driver, holder including LED tubelight connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S & F in Ceiling rose surface bakelite 65x50mm, two to three terminals.
S & F in replacement Sheet metal enclosure for DB's Single door, single pole and neutral, 240V, 8 way with 200 Amp rated bus bar including blanking plates where required. Complete all as specified and directed.
Supply and fixing in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SPN 40 to 63 Amp in the MCB DB complete with connection testing and commissioning.
Supply and fixing in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SP 5 to 32 Amp in the MCB DB complete with connection testing and commissioning.
PVC rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 200x150x50 mm deep
S & F Sub main wiring with two single core 6 sqmm multistranded copper conductor cable, PVC insulated cable 1100 volts grade and 6 Sqmm as continous earthing drawing and including PVC casing and caping of suitable size with all acessories, complete all as specified.
S&F in replacement 1100 volts grade heavy duty 10 sqmm 2 core flat cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 01 metre apart including 4 mm suspension complete all as specified.
S&F in LED light fitting 1x10W bulkhead luminaries including LED light driver holder connecting up three core flexible copper conductor cable of suitable size.
Replacemet of Earthing complete with galvanised steel earth plate electrode 600mm x 600mm and 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connected to the Galvanized iron earth wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel as shown in electrical plate No. 3 conected to earth test point as specified or indicated including testing on completion.
Note : Deduction for amount of Rs 46623.00 as listed in Schedule A Part - II ( Schedule of Credit) shall be made while awarding of contract.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .